MGC ALCN-4792MISO Isolated Quad Loop Adder Module User Manual

June 9, 2024
MGC

ISOLATED QUAD LOOP ADDER MODULE
ALCN-4792MISO

Features

  • Isolated
  • Dedicated Central Processor Unit (CPU) per module
  • Expands system capacity to 636 addressable devices on 2 loops, 159 Analog Sensors and 159 Addressable Modules per loop
  • With the addition of the ALCN-792D this expands module an additional 2 loops bringing module capacity to 1272 addressable devices.
  • Compatible with the Flex-NetTM FX-4000N Series

Description

The ALCN-4792MISO Isolated Quad Loop Adder Module provides two addressable loops plus an additional two loops as part of the daughter board ALCN-792D which is mounted over the ALCN-4792MISO. The quad loop adder module provides Signaling Line Circuits (SLC) to the Flex-Net ™ FX-4000N Series Fire Alarm Systems, consisting of 159 Sensors and 159 Addressable Modules per loop.
Each ALCN-4792MISO Loop Controller Module has a dedicated Central Processor Unit (CPU) and will support two fully loaded SLC lines which will provide up to 318 addressable devices per SLC line, for a total of up to 636 addressable devices per ALCN-4792MISO Quad Loop Controller module.
The ALCN-4792MISO occupies one module space on any Flex-Net ™ FX-4000N Series control panel chassis
The ALCN-792D daughter board provides two additional SLC lines for up to 318 addressable devices per SLC line, for a total of up to 1,272 addressable devices per combination ALCN4792MISO with ALCN-792D.

Power Consumption

Normal Operation Voltage Amperes
Standby 0.255
Alarm 0.265

Ordering Information

Model Description
ALCN-4792MISO Isolated Quad Loop Adder Module

Canada
25 Interchange Way Vaughan, ON L4K 5W3
Telephone: 905-660-4655 | Fax: 905-660-4113

U.S.A.
4575 Witmer Industrial Estates Niagara Falls, NY 14305
Toll Free: 888-660-4655 | Fax Toll Free: 888-660-4113
www.mircom.com

THIS INFORMATION IS FOR MARKETING PURPOSES ONLY AND NOT INTENDED TO DESCRIBE THE PRODUCTS TECHNICALLY.
For complete and accurate technical information relating to performance, installation, testing and certification, refer to technical literature. This document contains intellectual property of Mircom. The information is subject to change by Mircom without notice. Mircom does not represent or warrant correctness or completeness.

CATALOG NUMBER
9526 Rev. 0
firealarmresources.com

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals