NETWORK FIRE ALARM CONTROL PANEL
FX-2009-12NDS
FX-2009-12NDS in a BB-5008R enclosure.
Description
Mircom’s FleX-Net Series is a powerful intelligent networkable fire alarm
solution designed with many levels of flexibility to to meet virtually any
application of detection, control, notification and emergency communications.
Features such as fire detection & alarm, audio/voice evacuation, BACnet,
Boolean logic, networking and graphical work stations allow this modular
solution to accommodate the simplest systems up to the most complex solutions
With the addition of the Advance Protocol (AP), Fire/CO detection and 520 Hz
support on both the addressable loop and through the audio/voice evacuation,
Mircom’s FleX-Net is poised to take you even farther into the future with
expanded capabilities.. Designed for peer-to-peer network communications, the
FX2009-12NDS allows
for a maximum of 63 nodes, while providing reliability, flexibility and
expandability.
Each base panel consists of one intelligent signaling line circuit (SLC)
capable of supporting 159 analog Sensors and 159 addressable modules. In
addition the base panel includes Four Style Z/Y (Class A/B) Notification
Appliance Circuits and an easy to read and use, large 4 x 20 back-lit
alphanumeric LCD display.
The network configuration allows the FX-2009-12NDS control panel to be
connected to a Mircom network to provide additional input circuits, visual
zones, programmable notification appliance circuits, and relays. The network
interface module allows the panels to communicate on a peer-to-peer network
via a Proprietary Arcnet Network Communications protocol.
Features
Fire Alarm Control
- 1 SLC loop expandable up to 29
- Each SLC Loop is capable of supporting 159 Analog Sensors and 159 Addressable Modules which can be wired in Style 6 or 7 (Class A) or Style 4 (Class B)
- Four Style Z/Y (Class A/B) Notification Appliance Circuits rated at 1.7 Amps each
- System has the ability to mix CLIP and AP devices on the same loop
- Large easy to use and readable 4 by 20 character Back-lit LCD Display
- English, French, Arabic and Hebrew language support (*supported by RAXN-LCDG Annunciator in place of main display)
- Correlatable Switch Inputs which allow for multi-functional outputs
- Four Status Queues for Alarm, Supervisory, Trouble and Monitor
- Auxiliary relay contacts for Common Alarm, Supervisory and Trouble
- Group bypass with built-in false alarm prevention technology
- RS-232 output for remote system printer or CRT
- Two event History Logs; one for Alarm-related events and one for all events.Supports 3 configuration files with “hot swap” support
- Conventional Hardwire Adder Module expandability
- Built-in Walk Test operation
- Canadian Two Stage operation
- Provision for two programmable modules
- Configurable for Coded Operation
- Intelligent Smoke Detector sensitivity levels
- 3D graphical monitoring and control using Mircom’s Open Graphic Navigator™
- BACnet support
- Advanced (Boolean) logic functions
- Built-in Ethernet port
- Remote diagnostics via a built-in web server
- Audio/Voice Evacuation with 520Hz capability
- UL listed for Smoke Control
- HVAC Fan and Damper Control
Network Features
- Up to 63 nodes
- Peer-to-peer network communications
- Style 4 (Class B) or Style 6 or 7 (Class A) wiring configuration
- Proprietary Arcnet Network Communications protocol
- Supports copper and/or fiber optic network cable
CATALOG NUMBER
5943
NOT TO BE USED FOR INSTALLATION PURPOSES.
THIS INFORMATION IS FOR MARKETING PURPOSES ONLY AND NOT INTENDED TO DESCRIBE
THE PRODUCTS TECHNICALLY.
FleX-NetTM FX-2009-12NDS Network Series Fire Alarm Control Panels
FX-2009-12NDS Large Size Network Main Control Unit
The FX-2009-12NDS Large Size Network Main Control Unit comes complete with one
Intelligent Signaling Line Circuit (SLC) Style 4, 6 or 7, Four Style Z/Y
(Class A/B) Notification Appliances Circuits (1.7 Amps each), a 4 line by 20
character back-lit LCD display and a 12 Amp Power Supply. The FX-200912NDS
provides space for the FNC-2000 Network Controller Module, up to 8 adder
modules and 2 internal display adder modules. The FX-2009-12NDS mounts in a
BB-5000 Series enclosures.
Power Supply Expansion
INX-10AC Internal Booster Power Supply Module
Mircom’s INX-10AC is an Intelligent Booster Power Supply that extends the
power capabilities of existing notification appliance circuits as well as
provide power for other ancillary devices. The INX-10AC has 10 amps of power
and mounts inside the BB-5014 enclosure.
Mounting Brackets
M500-BK9 Module Mounting Bracket
The M500-BK9 Module Mounting Bracket mounts inside the BB-5000 Series
enclosures and provides space to mount up to nine M500 style intelligent
modules.
Electrical Specifications
Primary Input Power | 120V 60Hz / 240V, 50Hz 4 Amps / 2 Amp (primary) |
---|---|
Power Supply Ratings | 12 Amps. max. (secondary) |
For NAC Circuits | 24VDC unfiltered, 10 Amps. max. Max. Voltage Drop Permitted |
(Class A = 3.3V, and Class B = 3.7V)
Battery Type| 24VDC, Gel-Cell/Sealed Lead-Acid
Battery Charging Capability| 17-65 AH batteries
ECX-0012 Expander Chassis
The ECX-0012 Expander Chassis for the FX-2009-12NDS supports up to 12 adder
modules and has space for 2 internal display modules. The ECX-0012 mounts in
the BB-5000 series enclosures.
BB-5008/BB-5014 Lobby Enclosures
The BB-5008 and BB-5014 lobby enclosures support the FX-2009-12NDS and provide
space for internal lobby control modules. The cabinets hold up to 24 AH
batteries. The door and chassis hardware are ordered separately.
BB-5008 Dimensions: 36”H x 30”W x 7”D
BB-5014 Dimensions: 60”H x 30”W x 7”D
Graphics Software
Open Graphic Navigator (OpenGN)
Open Graphic Navigator (OpenGN) is a centralized fire alarm management system
that provides building or campus monitoring. As a powerful integration tool,
OpenGN allows operators to monitor remote sites from multiple workstations or
smart phones located anywhere in the world. OpenGN displays monitored
buildings and campuses in both 2D and 3D representations, and is highly
customizable.
NOT TO BE USED FOR INSTALLATION PURPOSES.
THIS INFORMATION IS FOR MARKETING PURPOSES ONLY AND NOT INTENDED TO DESCRIBE
THE PRODUCTS TECHNICALLY.
Fire Network Controller Modules
FNC-2000 Fire Network Controller Module
The FNC-2000 provides network capability to the FX-200912NDS. One Fire Network
Controller Module is required per network node panel. In addition the FNC-2000
provides an interface for adding an optional FOM-2000-SP Fiber Optic Network
Adder Module. The FNC-2000 mounts in the FX2009-12NDS.
FOM-2000-SP Fiber Optic Network Adder Module
The FOM-2000-SP Fiber Optic Network Adder Module allows for the use of fiber
optic cabling on the FX-2009-12NDS. It seamlessly connects to the interface on
the FNC-2000 Fire Alarm Network Controller Module.
Adder Loop Controller Modules
ALCN-792MISO Isolated Quad Loop Controller Module
The ALCN-792MISO Isolated Quad Loop Controller Module provides two Signaling
Line Circuits (SLC) to the FleXNet system consisting of 159 Analog Sensors and
159
Addressable Modules per loop. The ALCN-792MISO can be expanded with the use of
the ALCN-792D Daughter Board Module. The ALCN-792MISO occupies one module
slot.
ALCN-792D Daughter board for Isolated Quad Loop Controller Module
The ALCN-792D Daughter Board provides an additional two SLC loops when
connected to the ALCN-792MISO Isolated Quad Loop Controller Module. The
daughter board mounts on top of the ALCN-792MISO.
Dimensions for Annunciator Module Enclosures
Model | Dimensions |
---|---|
BB-1001D/DR/DB/DS | 9″H x 12.75.W x 1.85-D |
BB-1002D/DR/DB/DS | 18″H x 12.75″W x 1.85″D |
BB-1003D/DR/DB/DS | 26.4″H x 12.75″W x 1.85″D |
BB-1008D/DR/DB | 33″H x 22.5″W x 1.85-D |
BB-1012D/DR/DB | 45″H x 22.5″W x 1.85-D |
Adder Hardwire Modules
DM-1008A Eight Initiating Circuit Module
The DM-1008A provides 8 Style B (Class B) or 4 Style D (Class A) Initiating
Circuits configurable for Alarm, Supervisory or Trouble zones. The DM-1008A
occupies one module slot in the FX-2009-12NDS.
SGM-1004A Four Notification Appliances Circuit Module
The SGM-1004A provides 4 Style Z/Y(Class A/B) Notification Appliance Circuits.
Each NAC circuit is rated at 1.7 Amps and has individual signal silence inputs
which are jumper selectable. The SGM-1004A occupies one module slot in the
FX-2009-12NDS.
RM-1008A Eight Relay Circuit Module
The RM-1008A provides the FleX-Net system with eight individual configurable
relays per module. Each relay provides one Form C contact rated at 28 VDC @1
Amp (resistive load) as well as a Green LED to indicate that the relay is
active. The RM-1008A occupies one module slot in the FX-2009-12NDS.
Adder Auxiliary Modules
UDACT-300A Digital Alarm Communicator Module
The UDACT-300A Digital Alarm Communicator Module allows the FleX-Net system to
transmit addressable point information to a central station. The UDACT-300A
occupies one module slot in the FX-2009-12NDS.
PR-300 Polarity Reversal/City Tie Module
The PR-300 Polarity Reversal/City Tie Module provides the system with a
supervised City Tie (24 VDC/200 mA max.) and Polarity Reversal connection (24
VDC (open circuit), 8 mA max. (shorted)). The PR-300 occupies one module slot
in the FX-2009-12NDS.
Remote LCD Annunciators
RAXN-LCD Remote LCD Annunciator
The RAXN-LCD Remote LCD Annunciator provides the same functions as the main
display on the fire alarm control panel. The RAXN-LCD occupies one display
position in the BB-1000 or BB-5000 Series enclosures.
RAXN-LCDG Remote Graphic LCD Annunciator
The RAXN-LCDG Remote Graphic LCD Annunciator equipped with a 24 line x 40
character back-lit graphical LCD display that is used to display 9 events per
page. Each
event is displayed over 2 lines with 40 characters per line allowing emergency
information to be displayed in an easy to read format. The RAXN-LCDG occupies
one display
position in the BB-1000 or BB-5000 Series enclosures.
Graphic Annunciator Driver Modules
MGD-32 Master Graphic Driver Module
The MGD-32 Master Graphic Driver Module provides common control inputs for the
common control switches such as System Reset, Signal Silence, Auxiliary
Disconnect, Fire Drill, Lamp Test, Acknowledge and General Alarm. The MGD-32
can also drive up to 32 supervised outputs. These output points are capable of
driving LEDs or incandescent lamps. The MGD-32 mounts in a graphic annunciator
wallbox or in the BB-5000 enclosures. An external power supply is required for
incandescent lamps and lamp test.
AGD-048 Adder Graphic Driver Module
The AGD-048 Adder Graphic Driver Module can be used with the MGD-32 to support
an additional 48 supervised outputs. The AGD-048 mounts in a graphic
annunciator wallbox or in the BB-5000 enclosures.
Remote LED Annunciators
RAM-1032TZDS Main Remote LED Annunciator
The RAM-1032TZDS Main Remote LED Annunciator provides common annunciator
functions and 32 points of LED annunciation. The RAM-1032TZDS has indicators
for A.C. On, Common Trouble and Signal Silence and controls for System Reset,
Lamp Test, Fire Drill, Buzzer Silence and Signal Silence. The RAM-1032TZDS
occupies one display position in the BB-1000 or BB-5000 enclosures.
RAX-1048TZDS Programmable LED Annunciator Module
The RAX-1048TZDS Programmable LED Annunciator Module provides 48 programmable
bi-colored LEDs. The RAX-1048TZDS connects to the main panel or either the
RAXN-LCD or RAM-1032TZDS when mounted remotely. The RAX-1048TZDS occupies one
display position in the BB-1000 or BB-5000 Series enclosures.
Programmable Modules
FDX-008W Fan Damper Control Module
The FDX-008W Fan Damper Control Module provides individually programmed
circuits which can be used for fan or damper control. The FDX-008W connects to
the main panel or the RAXN-LCD and occupies one display position in the
BB-1000 or BB-5000 Series enclosures.
IPS-2424DS/IPS-4848DS Programmable Input Switches Module
The IPS-2424DS/IPS-4848DS provides 24/48 programmable switches that can be
configured for ancillary functions such as zone bypass or added common control
functions. The IPS-2424DS/IPS-4848DS connects to the main panel or the RAXN-
LCD when mounted remotely. The IPS-2424DS/IPS-4848DS occupies one display
position in the BB-1000 or BB-5000 Series enclosures.
Typical FleX-Net™ FX-2009-12NDS Networked System Configuration
Current Consumption
Model Number | Description | Standby | Alarm |
---|---|---|---|
FX-2009-12NDS | Main Control Unit (12 Amp) | 0.310 | 0.733 |
ALCN-792MISO | Isolated Dual Analog Loops | 0.130 | 0.145 |
ALCN-792MISO/D | Isolated Quad Analog Loops | 0.130 | 0.145 |
FNC-2000 | Fire Network Controller Module | 0.190 | 0.0190 |
FOM-2000-SP | Fiber Optics Module | 0.015 | 0.015 |
DM-1008A | 8 Initiating Circuit Module | 0.080 | 1 zone active: 0.125 |
2 zone active: 0.170 4 zone active: 0.275 6 zone active: 0.370 8 zone active:
0.465
SGM-1004A| 4 Notification Appliances Circuit Module| 0.060| 0.258
RM-1008A| 8 Relay Circuit Module| 0.025| 0.150
FDX-008W| Fan Damper Control Module| 0.015| 0.035
UDACT-300A| Dialer Module| 0.045| 0.120
PR-300| City Tie Module| 0.035| 0.300
RAX-1048TZDS| Adder Annunciator Chassis| 0.022| 1 zone active: 0.026
2 zone active: 0.030
3 zone active: 0.035
4 zone active: 0.039
48 zone active: 0.262
RAM-1032TZDS| Adder Annunciator Chassis| 0.050| 32 zone active: 0.300
MGD-32| Main Graphic Driver Module| 0.035| 1.6
AGD-048| Adder Graphic Driver Module| 0.035| # of LEDs x 4mA
IPS-2424DS| Programmable Input Switches Module| 0.010| 0.015
IPS-4848DS| Programmable Input Switches Module| 0.010| 0.022
Ordering Information
Model | Description |
---|
Network Fire Alarm Control Panel
FX-2009-12NDS| Large Size Network Main Control Unit. Mounts in the BB-5000
series enclosures.
ECX-0012| Expander Chassis for the FX-2009-12NDS. Mounts in the BB-5000
series enclosures.
Enclosures|
BB-5008| Lobby Control Centre Wallbox Enclosure. Supports 8 Module
Footprints.
DOX-5008M| White Metal Door for BB-5008. Add suffix ‘R’ for red enclosure.
CCH-5008| Custom Mounting Kit for BB-5008. One required per BB-5008.
BB-5014| Lobby Control Centre Wallbox Enclosure. Supports 14 Module
Footprints.
DOX-5014M| White Metal Door for BB-5014. Add suffix ‘R’ for red enclosure.
CCH-5014| Custom Mounting Kit for BB-5014. One required per BB-5014.
Network Controller Modules
FNC-2000| Fire Network Controller Module
FOM-2000-SP| Fiber Optic Network Adder Module
Adder Loop Controller Modules
ALCN-792MISO| Network Isolated Quad Loop Controller Module
ALCN-792D| Daughter board for ALC-792MISO Isolated Quad Loop Controller Module
Adder Hardwire Modules|
DM-1008A| Eight Class B (Style B) or 4 Class A (Style D) Initiating Circuit
Module
SGM-1004A| Four Class A/B (Style Z/Y) Notification Appliances Circuit Module
(Rated at 1.7 Amps per circuit)
RM-1008A| Eight Relay Circuit Module c/w eight form C relays (Rated for 28 VDC
@ 1 Amp max. per relay)
Adder Auxiliary Modules|
UDACT-300A| Digital Alarm Communicator Transmitter/Dialer Module
PR-300| Polarity Reversal and City Tie Module
Remote Annunciators|
RAXN-LCD| Remote LCD Annunciator
RAXN-LCDG| Remote Graphic LCD Annunciator
RAM-1032TZDS| Main Remote LED Annunciator c/w 32 Bi-Colored LEDs
RAX-1048TZDS| Programmable LED Annunciator Module c/w 48 Bi-Coloured LEDs and
48 Trouble LEDs
Programmable Modules|
IPS-2424DS| Programmable Input Switches Module c/w 24 selector switches and 24
bi-coloured LEDs
IPS-4848DS| Programmable Input Switches Module c/w 48 selector switches and 48
bi-coloured LEDs
FDX-008W| Fan Damper Control Module
Programmable Modules|
INX-10AC| Internal Booster Power Supply Module
Enclosures for Remote Annunciators / Programmable Modules
BB-1001D| Remote Enclosure. Houses one module. Add suffix “R” for red, “S”
for stainless steel, and “B” for
black door.
BB-1002D| Remote Enclosure. Houses two modules. Add suffix “R” for red, “S”
for stainless steel, and “B” for
black door.
BB-1003D| Remote Enclosure. Houses three modules. Add suffix “R” for red, “S”
for stainless steel, and “B”
for black door.
BB-1008D| Remote Enclosure. Houses eight modules. Add suffix “R” for red and
“B” for black door.
BB-1012D| Remote Enclosure. Houses twelve modules. Add suffix “R” for red and
“B” for black door.
Graphic Driver Modules|
MGD-32| Main Graphic Driver Module c/w 32 Supervised Outputs
AGD-048| Adder Graphic Driver Module c/w 48 Supervised Outputs
Graphics Software|
OGN-FLSLIC-ONE| Single Fire Alarm Control Panel License (Price per connection)
Requires: OGN-KEY (sold seperately) Contact us for non-Mircom panel
connections
OGN-FLSLIC-EXP| Fire Alarm Control Panel License for 2-9 Connections (Price
per connection)
Requires: OGN-KEY(sold seperately) Contact us for non-Mircom panel connections
OGN-FLSLIC-STD| Fire Alarm Control Panel License for 10-99 Connections (Price
per connection)
Requires: OGN-KEY (sold seperately) Contact us for non-Mircom panel
connections
OGN-FLSLIC-ENT| Fire Alarm Control Panel License for 100+ Connections (Price
per connection)
Requires: OGN-KEY (sold seperately) Contact us for non-Mircom panel
connections
OGN-KEY| OGN License Key Stick
Accessories|
UIMA4| Interface for Configuring MGC Fire Panels
MGC-CONFIG-KIT4| Fire Panel Configuration KIT with UIMA4.
Canada
25 Interchange Way
Vaughan, Ontario L4K 5W3
Telephone: 905-660-4655
Fax: 905-660-4113| U.S.A.
4575 Witmer Industrial Estates
Niagara Falls, NY 14305
Toll Free: 888-660-4655
Fax Toll Free: 888-660-4113
---|---
THIS INFORMATION IS FOR MARKETING PURPOSES ONLY AND NOT INTENDED TO DESCRIBE
THE PRODUCTS TECHNICALLY.
For complete and accurate technical information relating to performance,
installation, testing and certification, refer to technical literature. This
document contains intellectual property of Mircom. The information is subject
to change by Mircom without notice. Mircom does not represent or warrant
correctness or completeness.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>