Receiving and Inspecting the Equipment
Upon receiving the appliance, inspect the shipping boxes and record any
external damage. Retain packing materials if you suspect that part of the
shipment is damaged; the carrier may need to inspect them.
If the boxes were not damaged in transit, unpack them carefully. Ensure that
you do not discard any accessories that may be packaged in the same box as the
main unit.
Inspect the packing list and confirm that you received all listed items.
Compare the packing list with your purchase order. Parts List provides a list
of components included with the appliance.
Installation Process
The following tasks are required to install and use the appliance:
- Select and prepare the installation site.
- Assemble the installation tools listed.
- Install the appliance.
- Connect the appliance to the power source and network appliances.
- Configure the appliance.
Important:
Class 1 Laser Product: This product has provisions to install Class 1 laser transceivers which provide optical coupling to the communication network. Once a Class 1 laser product is installed, the equipment is a Class 1 Laser Product. The customer is responsible for selecting and installing the Class 1 laser transceiver and for insuring that the Class 1 AEL (Allowable Emission Limit) per EN/IEC 60825, CSA E60825-1, and Code of Federal Regulations 21 CFR 1040 is not exceeded after the laser transceiver have been installed. Do not install laser products whose class rating is greater than 1. Refer to all safety instructions that accompanied the transceiver prior to installation. Only Class 1 laser appliances, certified for use in the country of installation by the cognizant agency are to be utilized in this product.
Important:
Ultimate disposal of this product should be handled in accordance with all national laws and regulations.
Safety Information
Refer to the Arista Networks document Safety Information and Translated Safety
Warnings available
at: https://www.arista.com/en/support/product-documentation.
Obtaining Technical Assistance
Any customer, partner, reseller, or distributor holding a valid Arista Service Contract can obtain technical support in any of the following ways:
-
Email: http://support@arista.com. This is the easiest way to create a new service request.
-
Web: https://edge.arista.com/support.
A support case may be created through the support portal on our website. You may also download the most current software and documentation, as well as view FAQs, Knowledge Base articles, Security Advisories, and Field Notices. -
Phone: +1 866-476-0000 or +1 408-547-5502.
Important:
No user serviceable parts inside. Refer all servicing to qualified service personnel.
Specifications
Table 1: Appliance Specifications (Dimensions and Weights)
Appliance | Size (W x D x H) | Weight |
---|---|---|
CCA-ETM-Q6E | 232mm x 174mm x 42mm | 1.4 kg |
Table 2: Appliance Specification (Operational and Storage)
Appliance| Operating Temperature and Humidity| Storage
Temperature and Humidity| Operating Altitude
---|---|---|---
CCA-ETM-Q6E| 0°C to 40°C
10 to 90% RH| -20°C to 70°C
5 to 95% RH| Sea level to 5000 meters.
Table 3: Appliance Specifications (Power Input)
Power Source | Ratings |
---|---|
AC INPUT – 40W Power Adapter | 100~240V, 1.2A, 50-60Hz |
Preparation
The following topics are covered in this section:
Site Selection
The following criteria should be considered when selecting a site to install the appliance.
-
Temperature and Ventilation: For proper ventilation, install the appliance where there is ample
airflow to the front and back of the appliance. The ambient temperature should not go below 0° or exceed 40°C.
Important: To prevent the appliance from overheating, do not operate it in an area where the ambient temperature exceeds 40°C (104°F). -
Rack Space : Install the appliance in a 19″ rack or cabinet. The appliance height is 1 RU. The rack mounting kit provides mounting brackets for two-post racks.
When mounting the appliance in a partially filled rack, load the rack from bottom to top, with the heaviest equipment at the bottom. Load the appliance at the bottom if it is the only item in the rack. -
Other Requirements: Select a site where liquids or objects cannot fall onto the equipment and foreign objects are not drawn into the ventilation holes. Verify these guidelines are met:
- Clearance areas to the front and rear panels allow for unrestricted cabling.
- All front and rear panel indicators can be easily read.
- Power cords can reach from the power outlet to the connector on the rear panel.
Important: All power connections must be removed to de-energize the unit.
Tools and Parts Required for Installation
The following tool(s) are required for installation:
- Philips #1 screwdriver
Electrostatic Discharge Precautions
Observe these guidelines to avoid ESD damage when installing or servicing the appliance:
- Assemble or disassemble equipment only in a static-free work area.
- Use a conductive work surface (such as an anti-static mat) to dissipate static charge.
- Wear a conductive wrist strap to dissipate static charge accumulation.
- Minimize handling of assemblies and components.
- Keep replacement parts in their original static-free packaging.
- Remove all plastic, foam, vinyl, paper, and other static-generating materials from the work area.
- Use tools that do not create ESD.
Mounting the Appliance
The following topics are covered in this chapter:
Desktop Installation
To install the CCA-EMT-Q6E on a desktop, complete the following steps.
- Remove the four screws on the wall mount bracket on the bottom of the appliance.
- Remove the wall mount bracket from the bottom of the appliance.
- Attach the rubber feet to the bottom corners of the appliance.
- Attach the cables according to Cabling the Appliance.
Rack Mounting the Appliance
To mount the appliance onto a two-post rack, remove the wall mount bracket,
mount the power supply unit, assemble the mounting brackets to the chassis,
and then attach the brackets to the rack posts.
The following topics are covered in this section:
- Mounting the Power Supply
- Attaching Mounting Brackets to the Chassis
- Inserting the Appliance into the Rack
Figure 1: CCA-ETM-Q6E Mounting Parts Kit
- Rack mounting bracket
- Rack mounting bracket
- Mounting screws
- Mounting screws
- Power supply bracket
- Fastening plate
- Power supply
Mounting the Power Supply
The following describes the process for mounting the power supply unit.
- Line up the power supply bracket (1) with the holes on the side of the appliance.
- Insert screws (2, 7) through the power supply bracket into the appliance.
- Place 40W PSU (3) inside the bracket.
- Secure PSU with fastening plate (5) and screws (6).
Attaching Mounting Brackets to the Chassis
This procedure attaches mounting brackets to the appliance chassis.
- Remove the four screws on the wall mount bracket on the bottom of the appliance.
- Remove the wall mount bracket from the bottom of the appliance.
- Place the mounting bracket (1) flush against one side and to the front of the chassis so that the holes in the bracket and the chassis are in line for the attachment screws.
- Use three screws (2) to attach the bracket to the chassis.
- Attach the second bracket (4) to the other side of the chassis with three screws (3).
Note: The bracket will extend away from the chassis and provide three larger holes to
attach to the rack as shown above.
Inserting the Appliance into the Rack
This procedure attaches the appliance to the rack.
-
Lift the chassis into the rack. Position the brackets against the rack posts at the same level.
-
Select mounting screws that fit your equipment rack.
Note: Screws required to attach the chassis to the posts are not included. Use the appropriate screws for the rack posts being used. -
Attach the brackets to the rack posts.
Mounting the Appliance on a Wall
You can mount the appliance on a wall or place the appliance on a flat surface, such as a desk or a shelf.
-
Drill two holes apart in the wall in a vertical or horizontal orientation
Note: Make sure you leave enough clearance around the appliance. -
Insert nylon plugs into the holes, then insert two 32mm x 6.35mm flat undercut screws into the plugs.
-
Attach the four provided rubber feet to aid ventilation.
-
Align the mounting holes on the appliance with the screws, then place the appliance on the screws. After the appliance is mounted on the wall and you have connected the cables, do not pull on the cables.
Cabling the Appliance
For all installations:
- Plug in the power adapter to a power source and connect it to the DC 12V power input on the rear panel.
- Connect an Ethernet cable from your Internet modem or router to WAN Port 1.
- Connect an Ethernet cable from your local network to LAN Port 1.
- Power on the system by pressing the power button located on the rear panel next to the power input.
- Allow approximately two minutes for the system to initialize before continuing with the next steps
Configuring the Appliance
Getting Started
You can manage your appliance via Edge Threat Management Dashboard or from the local network.
From Edge Threat Management Dashboard
- Navigate your web browser to https://edge.arista.com/cmd.
- Log in with your Edge Threat Management Dashboard account, or click Create Account to set up an account.
- Navigate to the Appliances screen and click Add.
- Enter the serial number located on the bottom of your appliance.
- Click Add to confirm the new appliance.
- Complete the initial setup to begin managing your appliance.
From the local network
- Connect an Ethernet cable from your management computer or LAN appliance to the LAN port.
- From your management computer, check the network status of your system and confirm that you receive an IPv4 address in the subnet of 192.168.1.0/24 (e.g. 192.168.1.100).
- In a browser, navigate to http://192.168.1.1.
- Follow the steps in your browser to complete the setup.
Status Indicators
The following topics are covered in this section:
A.1 Front Indicators
- Speed status
- Data
- Power
- WAN/SFP connections
- LAN Gb Ethernet connections
- Connection status
Parts List
Package Contents
The CCA-ETM-Q6E package includes:
- Power Adapter
- Power Cable
- Rubber Feet
Rear Panel
This appendix displays the rear panel of all appliances covered by this guide.
- LAN Gb Ethernet ports
- SFP WAN ports
- Ethernet WAN ports
- 3.0 USB ports
- Console port
- Power button
- Power supply port
Note: The SFP WAN ports and Ethernet WAN ports are “combo ports”. A choice must be made between SFP and Ethernet ports for the designated port number.
Regulatory Model Numbers
This appendix covers the Regulatory Model Number for the appliance in this guide.
Table 4: Regulatory Model Numbers and Product Numbers
Regulatory Model Numbers (RMN) | Product Numbers |
---|---|
AN2207, CAF-0262-5621-E90 | CCA-ETM-Q6E |
Taiwan RoHS Information
This appendix provides Taiwan RoHS information for appliances covered by this guide.
For the Taiwan BSMI RoHS Table, go to https://www.arista.com/assets/data/pdf/AristaBSMIRoHS.pdf.
© Copyright 2023 Arista Networks, Inc. All rights reserved. The information contained herein is subject to change without notice. The trademarks, logos and service marks (“Marks”) displayed in this documentation are the property of Arista Networks in the United States and other countries. Use of the Marks are subject to Arista Network Term of Use Policy, available at http://www.arista.com/en/terms-of-use. Use of marks belonging to other parties is for informational purposes only.
Headquarters
5453 Great America Parkway, Santa Clara, CA 95054
USA
+1-408 547-5500
| Support
+1-408 547-5502
+1-866 476-0000
| Sales
+1-408 547-5501
+1-866 497-0000
---|---|---
https://www.arista.com/en/|
mailto:support@arista.com|
mailto:support@arista.com
References
- Data-Driven Cloud Networking - Arista
- Arista Edge Threat Management
- Data-Driven Cloud Networking - Arista
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>