ARISTA CCA-ETM-Q12 Edge Threat Management Appliance User Guide
- June 9, 2024
- ARISTA
Table of Contents
ARISTA CCA-ETM-Q12 Edge Threat Management Appliance
Overview
This Quick Start Guide (QSG) describes the CCA-ETM-Q12 appliance. This chapter contains the following topics:
- Scope
- Receiving and Inspecting the Equipment
- Installation Process
- Safety Information
- Obtaining Technical Assistance
- Specifications
Scope
This guide is intended for properly trained service personnel and technicians
who need to install the following Arista appliance:
This guide is covers the CCA-ETM-Q12 appliance.
Important: Only qualified personnel should install, service, or replace this equipment.
Receiving and Inspecting the Equipment
Upon receiving the appliance, inspect the shipping boxes and record any
external damage. Retain packing materials if you suspect that part of the
shipment is damaged; the carrier may need to inspect them.
If the boxes were not damaged in transit, unpack them carefully. Ensure that
you do not discard any accessories that may be packaged in the same box as the
main unit.
Inspect the packing list and confirm that you received all listed items.
Compare the packing list with your purchase order. The Parts List provides a
list of components included with the appliance.
Installation Process
The following tasks are required to install and use the appliance:
- Select and prepare the installation site (Site Selection).
- Assemble the installation tools listed (Tools Required for Installation).
- Install the appliance (Mounting the Appliance).
- Connect the device to the power source and network appliances (Cabling the Appliance).
- Configure the appliance (Configuring the Appliance).
Important:
Class 1 Laser Product: This product has provisions to install Class 1 laser
transceivers which provide optical coupling to the communication network. Once
a Class 1 laser product is installed, the equipment is a Class 1 Laser
Product. The customer is responsible for selecting and installing the Class 1
laser transceiver and for insuring that the Class 1
AEL (Allowable Emission Limit) per EN/IEC 60825, CSA E60825-1, and Code of
Federal Regulations 21 CFR 1040 is not exceeded after the laser transceiver
have been installed. Do not install laser products whose class rating is
greater than 1. Refer to all safety instructions that accompanied the
transceiver prior to installation. Only Class 1 laser devices, certified for
use in the country of installation by the cognizant agency are to be utilized
in this product.
Important: Ultimate disposal of this product should be handled in accordance with all national laws and regulations.
Safety Information
Refer to the Arista Networks document Safety Information and Translated Safety Warnings available at: https://www.arista.com/en/support/product- documentation.
Obtaining Technical Assistance
Any customer, partner, reseller, or distributor holding a valid Arista Service Contract can obtain technical support in any of the following ways:
-
Email: http://support@arista.com. This is the easiest way to create a new service request.
-
Web: https://www.arista.com/en/support.
A support case may be created through the support portal on our website. You may also download the most current software and documentation, as well as view FAQs, Knowledge Base articles, Security Advisories, and Field Notices. -
Phone: +1 866-476-0000 or +1 408-547-5502.
Important:
No user serviceable parts inside. Refer all servicing to qualified service
personnel.
Specifications
This section lists the specifications of the CCA-ETM-Q12.
Table 1: Appliance Specifications (Dimensions and Weights)
Appliance | Size (W x D x H) | Weight |
---|---|---|
CCA-ETM-Q12 | 438mm x 429mm x 44mm | 6.4 kg |
**Table 2: Appliance Specifications (Operational and Storage)**
Appliance| Operating Temperature & Humidity| Storage Temperature
& Humidity| Operating Altitude
---|---|---|---
CCA-ETM-Q12| 0 to 40°C
20% – 80%| -10 to 70°C
5 to 95% RH @ 55°C| 0 to 2000 meters
**Table 3: Appliance Specifications (Power Input)**
Power Source (PSU) | Rating |
---|---|
250W | 100-240V |
Preparation
This section describes the initial setup and preparation for installing the CCA-ETM-Q12. This chapters contains the following topics:
- Site Selection
- Tools Required for Installation
- Electrostatic Discharge (ESD) Precautions
Site Selection
The following criteria should be considered when selecting a site to install
the appliance.
-
Temperature a n d Ventilation: For proper ventilation, install the appliance where there is ample airflow to the front and back of the appliance. The ambient temperature should not go below 0° or exceed 40°C.
Important: To prevent the appliance from overheating, do not operate it in an area where the ambient temperature exceeds 40°C (104°F). -
Airflow Orientation: The airflow of the appliance travels from front to back.
-
Rack Space: Install the appliance in a 19″ rack or cabinet. The appliance height is 1 RU. The rack mounting kit provides mounting brackets for four-post racks.
When mounting the appliance in a partially filled rack, load the rack from bottom to top, with the heaviest equipment at the bottom. Load the appliance at the bottom if it is the only item in the rack. -
Other Requirements: Select a site where liquids or objects cannot fall onto the equipment and foreign objects are not drawn into the ventilation holes. Verify these guidelines are met:
-
Clearance areas to the front and rear panels allow for unrestricted cabling.
-
All front and rear panel indicators can be easily read.
-
Power cords can reach from the power outlet to the connector on the rear panel.
Important: All power connections must be removed to de-energize the unit.
Tools Required for Installation
These are the tools needed to install the CCA-EMT-Q12 appliance.
Table 4: Tools required for installation
1 #2 Phillips screwdriver
Electrostatic Discharge (ESD) Precautions
Observe these guidelines to avoid ESD damage when installing or servicing the appliance.
- Assemble or disassemble equipment only in a static-free work area.
- Use a conductive work surface (such as an anti-static mat) to dissipate static charge.
- Wear a conductive wrist strap to dissipate static charge accumulation.
- Minimize handling of assemblies and components.
- Keep replacement parts in their original static-free packaging.
- Remove all plastic, foam, vinyl, paper, and other static-generating materials from the work area.
- Use tools that do not create ESD.
Mounting the Appliance
The appliance is mounted onto a four-post rack by preparing the chassis for mounting, then securing the appliance to the front posts using the mounting brackets, followed by securing it to the rear posts.
The installation kit provides the following four-post mounting parts:
- Two front mounting brackets.
- Two rails.
- Two rail caps.
- Six screws for the front mounting brackets.
- Ten screws to attach the side rails to the chassis and the rail caps to the rails.
See illustration at Parts List.
Note: Each chassis side has holes that allow for the attachment of the
slide rails. Ensure that the rails are attached symmetrically to the left and
right sides of the chassis and the slides can be extended to connect with the
rear rack posts. Depending on the depth of the rear rack, the number of screws
required will vary.
Note: A minimum of three screws is recommended for each slide rail.
Rack Mounting the Appliance
- 1 Mounting screws
- 2 Left bracket
- 3 Mounting screws
- 4 Right bracket
- Align the left bracket to the left face plate.
- Attach the left front mounting bracket using three mounting screws.
- Align the right bracket to the right face plate.
- Attach the right front mounting bracket using three mounting screws.
- 1 Mounting rail
- 2 Mounting screws
- Align the left rail to the four holes on the left side of the appliance.
- Attach the left rail using four mounting screws.
- Align the right rail to the four holes on the right side of the appliance.
- Attach the right rail using four mounting screws.
- 1. Back rack post
- 2. Back bracket
- 3. Mounting screws
- 4. Front rack post
- 5. Front bracket
- 9. Mounting screws
- Insert the appliance into the racking at the predetermined height within the left side of the rack.
- Attach the left rear mounting bracket using three mounting screws.
- Attach the left front mounting bracket using three mounting screws.
- Repeat Steps 2 and 3 for the right side appliance installation into the racking.
Cabling the Appliance
This procedure is for the attachment of power and network cables to the appliance.
- Connect an Ethernet cable from your Internet provider modem or router to the designated Internet port.
- Connect an Ethernet cable from your management computer or LAN switch to port 1.
- Plug in the power cable to an AC power source and connect it to the power input on the rear panel.
Configuring the Appliance
You can manage your appliance using the Edge Threat Management Dashboard or from the local network.
From Edge Threat Management Dashboard
- Navigate your web browser to http://edge.arista.com/cmd.
- Log in with your Edge Threat Management Dashboard account, or click Create Account to set up an account.
- Navigate to the Appliances screen and click Add.
- Enter the serial number located on the bottom of your appliance.
- Click Add to confirm the new appliance.
- Complete the initial setup to begin managing your appliance.
From the Local Network
- Connect an Ethernet cable from your management computer or LAN switch to the LAN port.
- From your management computer, check the network status of your system and confirm that you receive an IPv4 address in the subnet of 192.168.2.0/24 (example: 192.168.2.100).
- In a browser, navigate to http://192.168.2.1.
- Follow the steps in your browser to complete the setup.
Status Indicators
A.1 Front Status Indicators
This section describes the front panel LED status of the CCA-ETM-Q12
appliance. Figure 1: CCA-ETM-Q12 Front Status Indicators
- LAN ports
- Storage activity
Parts List
Each appliance provides an accessory kit that contains parts that are required to install the appliance. This section lists the installation parts contained in the appliance accessory kit.
- Back brackets (2)
- Mounting brackets (2)
- Mounting rails (2)
- Power cable
- Racking mounting screws (10)
- Appliance mounting screws (6)
The CCA-ETM-Q12 package includes:
- Power cable.
- Rack mounting hardware.
- The CCA-ETM-Q12 appliance.
The installation kit provides the following four-post mounting parts:
- 2 front mounting brackets (left and right).
- 2 rails (left and right).
- 6 screws for the front mounting brackets.
- 10 screws to attach the side rails to the chassis and the back plates to the rails.
- 2 back plates (left and right).
Front Panel
This section shows the front panel of the CCA-ETM-Q12.
- LED screen
- USB ports
- LAN ports
- 1 Gbit SFP LAN ports
Rear Panel
This section shows the rear panel of the CCA-ETM-Q12.
- Fans
- Video out (HDMI)
- Power switch
- Power cord socket
- Fan
Regulatory Model Numbers
This appendix lists the Regulatory Model Numbers (RMNs), where applicable, for the product models for the appliances described in this document.
Table 5: Regulatory Model Numbers and Product Numbers
Regulatory Model Number (RMN) | Product Number(s) |
---|---|
AN2203, CAR-3070-5C21-E90 | CCA-ETM-Q12 |
Taiwan RoHS Information
This appendix provides Taiwan RoHS information for appliances covered by this
guide.
For Taiwan BSMI RoHS Table, go to
https://www.arista.com/assets/data/pdf/AristaBSMIRoHS.pdf.
References
- Arista Edge Threat Management
- Data-Driven Cloud Networking - Arista
- Data-Driven Cloud Networking - Arista
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>