Braking setting functions
| : Braking mode selection
---|---
: Release frequency
: Release time
: Creeping frequency
: Creeping time
Function
Setting functions to control braking timing.
Parameter setting for braking setting function
Title | Function | Setting range | Default settin |
---|---|---|---|
Braking mode selection | 0: Disabled |
1:Enabled (forward run)
2:Enabled (reverse run)
3:Enabled (operating direction)| 0
| Release frequency| – 20.0 [Hz]| 3.0
| Release time| 0.00 – 2.50 [s]| 0.05
| Creeping frequency| – 20.0 [Hz]| 3.0
| Creeping time| 0.00 – 2.50 [s]| 0.10
Title| Function| Setting range| Setting value
---|---|---|---
| Output terminal selection 1A
(RY-RC)| 0 – 255| 46:BR (Braking sequence output)
or
47:BRN (Inversion of braking sequence output)
Note) In case of others output terminal, it is deferent from parameter title.
RY-RC:
FLA-FLB-FLC:
Explanation of braking setting function
At starting the motor:
When the operation signal is ‘ON’, the brake release signal is ‘ON’ after
getting the flux of magnetic induction before brake releasing.
The output torque of inverter is generated before the brake is released by
outputting ‘the frequency of the setting’ to ‘the direction of the setting’.
The motor is able to accelerate smoothly at the same time as releasing the
brake because function provides ‘the delay of acceleration beginning ‘.
At stop the motor:
When the operation signal is ‘OFF’, the brake close signal is ‘ON’ after
reaching the creeping frequency of setting. After that, the VF-S11 outputs
creeping frequency while setting time of , and stops after delayed time of
mechanical brake.
Braking mode selection
0: Disabled
1: Enabled (forward run)
The rise operation is forward rotation of motor at RISE/DESCENT action.
The direction of inverter output frequency ( ) is forward direction regardless
of FORWARD/REVERSE drive.
2: Enabled (reverse run)
The rise operation is reverse rotation of motor at RISE/DESCENT action.
The direction of inverter output frequency ( ) is reverse direction regardless
of FORWARD/REVERSE drive.
3: Enabled (operating direction)
This value is for the horizontal operation.
The direction of inverter output frequency ( ) is same as direction of drive.
Release frequency
The inverter outputs ‘s frequency to ‘s direction. This function is for
generating motor torque by slipping of the restrained motor. By this, the
motor starts smoothly when the brake is released.
The setting value depends on load condition. The standard setting is ‘the
slipping frequency’ at rated output of applied motor.
Release time
The release time is time to maintain frequency of setting at start.
The standard setting is delayed time of mechanical brake.
Creeping frequency
The ‘close brake signal’ outputs ‘s frequency while ‘s setting time at stop.
The setting value depends on load condition. The standard setting is
The setting value depends on load condition. The standard setting is ‘the
slipping frequency’ at rated output of applied motor
Creeping time
The creeping time is time to maintain frequency of .
The standard setting is a little more than delayed time of mechanical brake.
Toshiba Schneider Inverter Corporation
The technical information in this manual is provided to explain the principal
functions and applications of the product, but not to grant you a license to
use the intellectual property or any other property of Toshiba Schneider
Inverter Corporation or a third party.
© Toshiba Schneider Inverter Corporation 2006
All rights reserved.
Documents / Resources
|
TOSHIBA TOSVERT Transistor
Inverter
[pdf] User Guide
TOSVERT Transistor Inverter, TOSVERT, Transistor Inverter, Inverter
---|---
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>