TRACTOR SUPPLY Super 4200 WPC Submersible Pool Cover Pump Instruction Manual

June 9, 2024
Tractor Supply

TRACTOR SUPPLY Super 4200 WPC Submersible Pool Cover Pump

READ THIS MANUAL BEFORE USING THIS PRODUCT. FAILURE TO FOLLOW THE INSTRUCTIONS AND SAFETY PRECAUTIONS IN THE MANUAL CAN RESULT IN SERIOUS INJURY OR DEATH. KEEP THIS MANUAL FOR FUTURE REFERENCE.

Thanks for choosing the Smartbot Submersible Pool Cover Pump Super 4200 WPC. If you have any questions about your Smartbot pump, call the Smartbot Helpline with your model information and details of where/when you bought the pump, or contact us via the Smartbot website.

DANGER /WARNING /CAUTION /NOTICE

Only people well acquainted with these rules of safe operation should be allowed to use the unit. Keep away from children!

Safety Signal Words
  • DANGER: Indicates an imminently hazardous situation which, if NOT avoided, WILL result in death or serious injury.
  • WARNING: Indicates a potentially hazardous situation which, if NOT avoided, could result in death or serious injury.
  • CAUTION: Indicates a potentially hazardous situation which, if NOT avoided, MAY result in minor or moderate injury.
  • NOTICE: Indicates important information, that if NOT followed, MAY cause damage to equipment.

DANGER

  • This pump is NOT rated for use with flammable / combustible liquids, vapors, or dust. The pump should be used to pump clear water ONLY. Failure to follow these instructions WILL result in bodily injury or death.
  • Electric shock hazard! GFCI receptacles will provide protection against line-to-ground faults only. The ground fault receptacle does NOT limit the magnitude of a fault current and will NOT prevent an electric shock.
  • DO NOT use pump if any part of the housing switch or probe is cracked, broken, or missing.
  • Always disconnect electrical supply before attempting to install, service, relocate, or perform any maintenance. Failure to do so WILL result in fatal electric shock!
  • Electric shock hazard! Use only Underwriters Laboratories (UL)- listed extension cord with #16 gauge or larger wire that is labeled for outdoor use. Use polarized grounding-type plugs only.
  • DO NOT attempt to service or open this product while it is connected to an electrical power supply.
  • DO NOT destroy and cut off the power cord for wiring, otherwise, it will be electrocuted.

WARNING

  • Electrical connections must be moved to higher ground where there is a risk of flooding.
  • If using an extension cord, do NOT allow pump cord/extension cord connection to fall into pool or come in contact with water. Pump/extension cord connection must be kept dry and away from moisture. DO NOT handle plug connector near water.
  • This pump is NOT designed for use in a swimming pool or marine area if the water contents of caustic chemicals, highly chlorinated water, and/or foreign materials.
  • DO NOT use the power cord or discharge hose to carry or handle the pump. Doing so may cause damage to either the power cord or discharge hose. Use the carrying handle supplied with the pump.
  • Never touch any electrical device, including this pump, when it is touching water, in water, or even in moist environment. Always unplug the unit when working on or installing it.
  • Always use a grounded outlet to attach the plug. A three-prong mating-type receptacle is needed for safe use. This should be in accordance with the National Electric Code and any additional codes or laws required by your local government.
  • This unit is NOT designed for use as a sump pump or in sump applications. This unit is NOT designed for use in septic tanks or underground vaults to pump raw sewage or effluents. NEVER use it in hazardous or explosive locations.
  • For safety reasons, it is recommended using sockets with leakage protection, especially in humid environments. The leakage protection device used should have the appropriate UL safety certification.
  • DO NOT attempt to service or open this product while it is connected to an electrical power supply.
  • DO NOT use this product to pump chemicals or corrosive liquids, damage to seals and moving parts will result.
  • DO NOT lift this product by the electrical power cord.

CAUTION

  • Check for damaged parts before each use. Carefully check that the pump will operate properly and perform its intended function. Replace damaged or worn parts immediately. Never operate the pump with a damaged part.
  • Never install a shutoff valve in the suction or discharge of this pump. This will cause excessive friction loss and will damage the pump and void the warranty.
  • All connections must be air-tight. A single leak will prevent proper operation of the pump and may cause the pump to run dry. If the pump runs dry, this will void the warranty.
  • DO NOT run the pump with the outlet closed or blocked. The excessive pressure will cause the pump to explode and cause injury or death.
  • DO NOT pump water that is hotter than 95° F.
  • DO NOT let let water inside pump freeze or let frost build up on pump.

NOTICE

  • Before attaching hoses to the inlet and outlet, wrap the threads of hose with PTFE tape.

Application

The pump is dual-used type.

When the big strainer base is assemble to the body of pump, the pump is designed and made for pumping water with automatic operation for a pool cover or spa cover. When the big strainer base is disassemble from the body of pump, it is a powerful pump for domestic uses, such as drying basements and garages subject to flooding or pumping drainage wells, rainwater-collecting traps, infiltrations from roof gutters, etc., Thanks to the compact size and handy shape after the strainer base disassembly, the pump can also be used for particular applications as portable pumps for emergency situations such as for drawing water from tanks or rivers, draining swimming pools and fountains, excavations, or underpasses, as well as gardening and general hobby activity.

Pumpable Liquids

ONLY WATER!!!

Clear Water Clear Ground Water Yes
Clear Water From Well or Cistern Yes
Ground Water With up to 1/4″ Diameter Solids Yes
Ground Water With up to 3/8″ Diameter Solids Effluent (Gray) Water No
Sewage Water With up to 2-1/4″ Diameter Solids Effluent Water No
Max. Solid handing [In.] Ø 1/4 inch Yes

Pool or Marine water

| From swimming pool or marine area if the water contents of caustic chemicals, high chlorinated, and/or foreign materials|

No

In the Box

1 Pump 7 Adaptor: 2” NPT to 3/4″ GHT
2 Elbow connector 8 Rope
3 Straight connector 9 Strainer base
4 Adaptor: 2” NPT to 1-1/2″ NPT 10 Instruction manual
5 Adaptor: 2” NPT to 1-1/4″NPT  
6 Adaptor: 2” NPT to 1″ NPT  

Functions

Quick Guide

STEP 1:  VERIFY PACKAGE CONTENTS

  • 1 Pool Cover Pump
  • 1 Elbow connector
  • 1 Straight connector
  • 4 Hose Adaptors
  • 1 32.8 feet red rope
  • 1 Strainer base

STEP 2:  INSTALLATION

  • Select the correct connector (elbow or straight) and adaptor (1-1/2”, 1-1/4”, 1”, 3/4”) and install them as instructed.

STEP 3:  ATTACH STRAINER BASE

STEP 4:  CONNECT GARDEN HOSE

STEP 5:  SECURE ROPE TO STRAINER BASE

STEP 6:  PLUG INTO GFCI OUTLET

Auto-Flo Instructions

Smartbot’s US patented Auto-Flo system has industry-leading liquid-sensing technology.

Normal straight status with strainer base on Pool Cover

Detect as little as 2-1/4” of floodwater. Once the water is detected, Smartbot automatically activates to pump the water out. When the water level reaches approximately 1/4” above the surface, Smartbot safely turns itself off.

Note: Removing water down to 1/4” depends on many factors. For the pump to remove as much water as possible, it must be on a leveled surface.

Normal straight status used as water pump without strainer base

Detect as little as 2” of floodwater. Once the water is detected, Smartbot automatically activates to pump the water out. When the water level reaches approximately 1/16” above the surface, Smartbot safely turns itself off.

Note: Removing water down to 1/16” depends on many factors. For the pump to remove as much water as possible, it must be on a leveled surface.

Led Light Signal

Troubleshooting

BEFORE TAKING ANY TROUBLESHOOTING ACTION, DISCONNECT THE PUMP FROM THE POWER SUPPLY. If there is any obvious damage to the power cable or pump, necessary repairs or replacements must be carried out by the manufacturer or an authorized customer support service, or by an equally qualified party, to prevent risk.

Symptom Possbile Cause(s) Actions for Consumer

The pump does not start, and there is no any noise from motor.

|

  • Power supply is improperly connected if eye signals are off.
  • Water level is lower than minimum level of starting pump.

|

  • Check if plug is inserted correctly to the required power source. Eye signals turning green means properly powered on.
  • Keep the water level higher than 2-1/4″.

The pump does not deliver flow properly, or the flow rate is insufficient.|

  • The suction bottom or the pipes are blocked.
  • The head lift required is higher than the feature of this pump.
  • Air is trapped inside impeller cavity and can’t be released.
  • Water level under the suction is lower than the minimum level required to start pumping.
  • The impeller is worn out or blocked.

|

  • Remove the obstructions under suction bottom or straighten the twisted hose.
  • Use a pump with higher head lift to meet needs.
  • Unplug the pump, and wait for 30 seconds before replug.
  • Water level needs be higher than 2-1/4″ to start pumping.
  • Unplug the pump, unscrew the 6 bolts at the bottom, and check whether the impeller is blocked by long fibers. If the blockage around the impeller is cleared and A, B, C, D are checked, the pump still can not deliver the flow normally, please call the help hotline for after-sales service help.

The pump does not start or Auto-On features do not work properly even though correctly connected to a power source.|

  • Water level is lower than minimum level to start pumping.
  • Air is trapped inside impeller cavity and can’t be released.
  • Sensors on both sides are clogged.

|

  • Keep the water level higher than 2-1/4″.
  • Unplug the pump, and wait for 30 seconds before replug.
  • Unplug the pump, and lift pump away from water to check its state. Take off the strainer base. If there is blockage around the sensor pins, remove it and clear the sensor area. If pump still does not auto on properly, please call the helpline for after-sale-service assistance.

The pump does not stop or Auto-Off features do not work properly.

|

  • Sensor pins under bottom base are clogged, or not in the right state.

|

  • Unplug the pump, and lift pump away from water to check its state. Take off the strainer base. If there is blockage around the sensor pins, remove it and clear the sensor area.
  • If step A is taken but pump still does not stop properly, please call the helpline for

after-sale-service assistance.

LED Eye light turns red.

|

  • Impeller is clogged.

|

  • Unplug the pump, and check if there is blockage around the bottom cover. If yes, remove it and check if eye turns green.
  • If step A is taken but eye light still turns red, please call the helpline for after-sale-service assistance.

Volute and Impeller Cleaning

  • Unplug the pump.
  • Remove the 6 screws shown in the figure below.
  • Remove the volute and clean the impeller and volute of all debris.
  • Reposition the cork gasket using the alignment features, preventing any possible obstruction of the pump’s discharge openings.
  • Reinstall the volute with caution. Do not over tighten or strip screws or screw bosses.

Technical Specifications

Contents Item Super 4200 WPC

Electrical data

| Power [HP]| 1/2
Voltage [V]| 120
Frequency [Hz]| 60
Current rating [A]| 4

Hydraulic data

| Max. flow rate [GPH]| 4200
Max. head [Ft]| 30
Min. AUT starting height [In.]| 2-1/4”
Stopping height [In.]| 1/4”

Range of use

| Length of power cable [Ft]| 25
Liquid temperature range [°F]| 32 to 95
Handles solids [In.]| 3/16
Outlet| 2’ NPT

Reaching Maximum Flow

To reach the maximum flow rate of 4200 gallons per hour, a discharge hose of 2 inches or more must be used. If the drainage pipe is less than 2 inches, the drainage volume will decrease accordingly.

CALIFORNIA PROPOSITION 65

This product contains chemicals known to the state of California to cause cancer or birth defects or other reproductive harm. California’s Proposition 65 requires this warning to be given to customers in the state of California.

Limited Warranty

Any modification made without prior authorization absolves the manufacturer of all responsibility. All the spare parts used in repairs must be authentic and all accessories must be authorized by the manufacturer, in order to ensure maximum safety of the machines and of the systems in which they may be installed. This product is covered by a legal guarantee (12 months from the date it was purchased) against all defects that can be assigned to manufacturing faults or the material used. The product under guarantee may, at discretion, either be replaced with one in perfect working order or replaced free of charge if the following conditions are observed:

  • The product has been used correctly in compliance with the instructions and no attempt has been made to repair it by the buyer or by third parties.
  • The product has been consigned to the outlet where it was purchased, attaching a document as proof of purchase (invoice or cash register receipt) and a brief description of the problem found. The impeller and parts subject to wear are not covered by the guarantee. Intervention under guarantee does not extend the initial guarantee period in any way.

Smartbot customer care

The manufacturer reserves right to change and upgrade products without any notice. In situations the manufacturer has changed or upgraded products, the manufacturer shall have no obligation to change or upgrade or otherwise modify previously manufactured products.

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Tractor Supply User Manuals

Related Manuals