Qingdao Richmat Intelligence Technology Inc HJSR81B Remote Control Key Instructions

June 1, 2024
Qingdao Richmat Intelligence Technology Inc

Qingdao Richmat Intelligence Technology Inc HJSR81B Remote Control Key

Product Information

Specifications:

  • Feature: Remote control for adjustable bed functions
  • Function: Control underbed light, flashlight, motor positions, massager, and light bar
  • Key Lock Function: Lock and unlock remote control keys
  • Multiplex Function: Record current motor position and status of massager and light bar

Product Usage Instructions

Remote Control Key Diagram:

Refer to the user manual for the detailed diagram of the remote control keys.

Remote Control Function Description:

Understanding the functions of each key on the remote control is crucial for proper usage.

Key Label:

The keys on the remote control are labeled for easy identification during operation.

Key Functions:

  1. UBL: Underbed light on/off, flashlight on/off (default 15s), reuse function for memorizable mode.
  2. Key Lock Function: Lock and unlock remote control keys.
  3. Multiplex Function: Record current motor position and status of massager and light bar.
  4. Back, Leg, and Lumbar Functions: Control the movement of back, leg, and lumbar motors.

Frequently Asked Questions

Q: How do I reset all memory positions to factory default?

A: Hold the flashlight + LOCK for about 3s simultaneously. The keys will enter one-button release mode to reset all memory positions to factory defaults.

Q: How do I lock and unlock the remote control keys?

A: Long press any key for 5 seconds to lock the remote control keys. Repeat the process to unlock the keys.

Q: How do I record the current motor position and status?

A: Use the multiplex function by holding the flashlight for about 5s, then press the corresponding key within 2s to record the position and status.

Remote control key diagram

Remote control function description

Key label Feature
1 UBL: Underbed light on/off (steady on)

2

| Flashlight on/off (default 15s). Reuse function:

① Hold down the button for 5s, the backlight flashes, enter the memorizable mode, press ZG/SNORE/M1 within 2s, the buzzer “beep” sound, you can remember the current motor position and the status of the massager and the light bar.

② Hold the flashlight +LOCK (lock) for about 3s at the same time, the backlight flashes twice, and the keys in all positions of the remote control enter the one-button release mode, which can reset all memory positions to the factory default memory positions at the same time.

③ Press and hold the flashlight +FLAT for about 3s at the same time, the backlight flashes three times, the keys in all positions of the remote control enter the

| continuous press mode, release the key and stop the motor.
---|---

3

| Key lock function: Long press the key for 5 seconds, the backlight flashes 3 times, lock the remote control key, then the remote control key is unavailable, press the key other than the lock key, the backlight flashes 3 times; Press the button again for 5 seconds, the backlight flashes 3 times, unlock the remote control button, then

the remote control button can be used.

4

| The motor runs to the ZG position (with initial value) with one click. Run the head and foot motor first, and run the external towing motor.

Multiplex function: Press and hold the flashlight for about 5s, the backlight blinks, press ZG within 2s, the buzzer rings 3 times, and record the current motor position, massager and light bar status to ZG. (Power off does not clear)

5

| The motor runs to M1 position (with initial value) with one click. Run the head and foot motor first, and run the external towing motor.

Multiplexing function: Hold the flashlight for about 5s, the backlight blinks, press M1 within 2s, the buzzer rings 3 times, and record the current motor position and the status of the massager and the light bar to M1. (Power

off does not clear)

6

| Run the motor to the SNORE position with one key (with initial value). When the one-key release mode is used, flatten and close the massager after 15min. Press any key to exit the timing. Continuous press mode no timing.

Multiplexing function: Hold the flashlight for about 5s, the backlight blinks, press SNORE within 2s, the buzzer rings 3 times, and record the current motor position and the status of the massager and the light bar to SNORE. (Power off does not clear)

7| Back rise: Hold down this key, the back motor starts to

rise, release this key, the back motor stops rising

8| Back down: Hold down this key, the back motor starts to

fall, release this key, the back motor drop stops

9| Leg rise: Hold down this key, the leg motor starts to rise,

release this key, the leg motor stops rising

10| Leg drop: Hold down this key, leg motor start to drop,

release this key, leg motor drop stop

11| LUMBAR rise: Hold down this key, the LUMBAR motor starts to rise, release this key, the LUMBAR motor stops rising
12| LUMBAR decline: Hold down this key, the LUMBAR motor
| begins to decline, release this key, the LUMBAR motor

decline stops

---|---

13

| FLAT one-button reset, all motors retracted to the minimum stroke position, turn off the massager, and keep the lamp under the bed in the state before pressing the

button (no reset on power-on)

14

| If the head massager is not opened, press the button to open the massager, the massager is the last closed state by default, if the massager is opened, press the button to increase the strength of the head massager, 3 strengths, in the order of: low – > medium – > high, the default time is 15 minutes, and the operation continues

when the highest strength is reached.

15

| Reduce the strength of the head massager, 3 strengths, when the lowest strength is reached, press the massager again to close.

16

| If the massager is not opened, press the button to open the massager, the massager is the last closed state by default, if the massager is opened, press the button to increase the strength of the foot massager, 3 strengths, in the order of: low – > medium – > high, the default time is 15 minutes, and the operation continues when the

highest strength is reached.

17

| Reduce the strength of the foot massager by 3, and press

the massager again to close when it reaches the lowest strength。

18

| The motor runs to M2 position with one key (with initial value). Run the head and foot motor first, and run the external towing motor.

Multiplexing function: Hold the flashlight for about 5s, the backlight blinks, press M2 within 2s, the buzzer rings 3 times, and record the current motor position and the status of the massager and the light bar to M2. (Power

off does not clear)

19

| Mode switching: CONSTANT- Low speed WAVE- Medium speed WAVE- high speed WAVE

Press and hold for 5s to turn off the massager. The

intensity remained unchanged after the mode was switched.

Coding m et h o d :

Keep pressing the head lift and foot drop buttons until the backlight flashes to clear the remote control code information; Power on the control box again, and the control box will be in the code alignment state within 60 seconds. Keep pressing the head down and foot up buttons of the remote control until the buzzer sounds and the backlight blinks, indicating that the code alignment is successful. Decoding mode:

[remote control head up + foot down] The backlight flashes, indicating successful decoding

* The control box has no reset function for code keys


Note:

Press any key over 50s, the remote control will enter sleep, release and press again to restore the function

FCC

Caution:
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals