timberk T-HU6-A19E-W Ulrtasonic Humidifier Instruction Manual

June 9, 2024
TIMBERK

timberk T-HU6-A19E-W Ulrtasonic Humidifier

timberk-T-HU6-A19E-W-Ulrtasonic-Humidifier-product

Dear customer!
We thank you for your wise choice and for a purchase of an ultrasonic humidifier. It will serve you for a long time.

IMPORTANT INFORMATION

Please, read this manual before using the device. This manual contains important information regarding your safety, as well as recommendations concerning the correct use and maintenance of this appliance. Keep this manual together with a warranty card, cash register receipt and, if possible, carton and packaging material. This instruction manual describes different types of this device. The device you purchased may differ slightly from the description in the manual, which does not affect the methods of use and operation. The manufacturer reserves the right to make minor changes to the device without additional notice which does not fundamentally affect its safety, performance and functionality. There may be some misprints in text and digital notations in the present manual.

IMPORTANT!
Important safeguards and descriptions contained in this manual do not include all possible situations that you may experience using the device. The manufacturer is not responsible for damage of the appliance or its parts during transportation, as a result of incorrect installation or voltage fluctuations, as well as when any part of the appliance has been changed or modified.

NOTE
There is a label on the device which has all the necessary technical data and other useful information about the device. Use the appliance only for the purpose specified in this manual.

SAFEGUARDS

Observe these safety rules when operating the device. Improper operation by ignoring the safeguards may result in damage to the health of the user and other people, as well as damage to their property. The manufacturer is not responsible for damage to health and property damage resulting from improper installation and operation of the device.

  • Read these instructions carefully before using the appliance to avoid damage during use.
    Before starting up for the first time, check that the specifications on the product comply with the power supply specifications.

  • The appliance must be monitored during its operation, especially if there are children nearby. Children must be supervised to prevent playing with the appliance.

  • The device is not intended for use by persons (including children) with reduced physical, sensory or mental abilities or in the absence of their life experience or knowledge, unless they are supervised or instructed on the use of the device by the person responsible for their safety.

  • This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Сleaning and user maintenance shall not be made by children without supervision.

  • Use only for domestic purposes in accordance with this instruction manual. The device is not intended for industrial use.

  • The humidifier must not be operated if its power cord is damaged, or if the humidifier is defective, or damaged in case of a fall or other circumstances. The humidifier should only be operated fully assembled.

  • Do not attempt to repair the device or change its parts by yourself. To repair the product, contact an authorized service center.

  • If the power cord or plug is damaged, to avoid danger, it must be replaced by the manufacturer, authorized service center, or similarly qualified personnel.

  • To avoid burns, do not touch the humidifier membrane, while it is operating. Due to the high oscillation frequency, the membrane becomes very hot.

  • To avoid risk of electric shock, do not place the power cord near heating appliances or flammable or combustible substances.

  • Remove the electrical plug from the power outlet in the following cases: before draining or filling the tank with water; before assembly, disassembly and cleaning, or if you do not use it; before mounting/dismounting the humidifier elements; before moving the humidifier to another location. Install the humidifier on a flat, dry surface.

  • When disconnecting the appliance from the mains, do not pull on the power cord, grasp the plug. Do not twist and do not wind it on anything.

  • Humidifier’s steam can damage the surfaces it touches. Do not install the humidifier on the floor, or in the vicinity of heating appliances, walls, furniture, or other items.

  • The manufacturer and seller are not responsible for damage caused by improper positioning of the humidifier. The humidifier should be installed on any elevation, for example, on a table, stand, etc. at least 60 cm from the floor and at least 10 cm from the wall.

  • Do not put the humidifier in water or other liquids.

  • Do not install the humidifier in the corridor or in other places where it may be hit, knocked over, etc. If the humidifier is not in use, disconnect it from the power supply.

  • Do not lay the power cord under carpets or other objects. Position the humidifier so that the cord can’t be accidentally touched. Make sure that the power cord does not touch sharp edges or hot surfaces.

  • Do not use outdoors or in high-humidity areas. Excessive humidity in the room can cause water to condense on windows and furniture. If this happens, turn off the humidifier.

  • Do not allow foreign objects to enter the humidifier.

  • Do not sit, stand, or place heavy objects on the humidifier.

  • To prevent damage to the humidifier, do not add essential oils, preservatives, flavorings, or other impurities to the water in the humidifier. The manufacturer and seller are not responsible for the damage to the humidifier in case of ignoring this warning.

NOTE
High-frequency vibrations of the membrane of the ultrasonic humidifier are not audible and are completely safe for people and pets.

  • If the device was at a temperature below 0ºC for some time, it must be kept at room temperature for at least 2 hours before turning it on.
  • Do not use accessories that are not supplied.

APPOINTMENT OF THE DEVICE

A humidifier increases relative air humidity in a room and stabilizes its microclimate, allowing it to avoid harmful conditions of low humidity. Comfortable conditions are achieved at a relative air humidity of 40 to 60%. Insufficient air humidity results in the dehumidification of mucous membranes which is the cause of a decrease in immunity, headache, cracking of lips, and “sandpaper” in the eyes, also insufficient air humidity enables the development of infection and causes respiratory illnesses, fatigue, increased eye fatigue and worsening of concentration, and has a negative effect on pets and indoor plants, causes increased dust generation and electrostatic charging of synthetic fabrics.

SPECIFICATIONS

Specifications of the device are shown in Table 1.

Table 1

Parameters Units T-HU6-A19E- W
The capacity of humidity (cool steam) ml/h 350
The capacity of humidity (warm steam) ml/h 450
Power supply V/Hz 220-240~/50
Water tank volume L 5
Rated power consumption W 110
Rated current А 0.85
Noise level dB(А) ≤ 39
Electrical protection class Class II
Device dimensions mm 235х200х322
Net weight kg 2.91

DEVICE DESCRIPTION

timberk-T-HU6-A19E-W-Ulrtasonic-Humidifier-fig- \(1\)

  1. Top cover
  2. Nozzle
  3. Ceramic filter
  4. Mist block cover
  5. Handle
  6. Water tank
  7. Float
  8. Housing
  9. Aroma capsule
  10. Air outlet
  11. Control panel
  12. Ultrasonic membrane
  13. Heating element
  14. Plug and power cord
  15. Remote control

The appearance of the device may differ from the images in the manual

DELIVERY SET

  1. Ultrasonic humidifier – 1 pc.
  2. Instruction manual – 1 pc.
  3. Warranty card – 1 pc.
  4. Packaging – 1 pc.
  5. Remote control -1 pc

FILLING THE WATER TANK

  1. Remove the cover with the nozzle from the tank.
  2. Pour water into the tank not higher than the end of the guide tube (“MAX mark).
  3. Place the cover with a nozzle on the tank.
  4. Plug the power cord into an electrical outlet.

IMPORTANT!
For the operation of the device, it is better to use purified water from the household water filter. It is necessary for the lifetime of the humidifier. With purified water, there will be no white spots around the device. White spots around the device are a salt of calcium and magnesium, which are part of ordinary tap water. When using unpurified water, they are discharged with steam and deposited on surrounding objects and surfaces. Although these substances are safe for people, in large quantities they can have harmful effects on furniture.

  • Do not fill the tank with other liquids but filtered tap water. Different composition of liquids has harmful effect on internal parts of the device and causes malfunctions.
  • Do not fill the unit or the water tank with such additives as essential oils, fragrances, cleaning agents, chemical medical drugs, warm water (above 40ºC), etc. Otherwise, the water tank and internal parts of the unit will be damaged and inoperable. Do not fill water directly into the internal parts of the unit or the atomizer.
  • Water inside the unit may cause malfunctions of the unit.
  • Do not hit or throw the water tank. It may get damaged resulting in water leaks. Do not use the unit in case if the water tank is heavily hit. Immediately contact the technical support service or the maintenance and repair station.
  • Every day fill the tank with fresh filtered water and keep the unit clean.

OPERATION OF THE DEVICE

Display

timberk-T-HU6-A19E-W-Ulrtasonic-Humidifier-fig- \(2\)

Control panel

timberk-T-HU6-A19E-W-Ulrtasonic-Humidifier-fig- \(3\)

timberk-T-HU6-A19E-W-Ulrtasonic-Humidifier-fig- \(4\)

  • on/off button
  • steam intensity adjustment/night mode
  • humidity level (hygrostat function)
  • timer
  • UV lamp/warm steam
  • selecting the illumination color

Remote Control
You can control the device using the remote control, which has the corresponding button panels. The remote control requires 1 CR2025 battery (not included).

  • on/off button

  • steam intensity adjustment/night mode

  • humidity level (hygrostat function)

  • timer

  • UV lamp / warm steam

  • selecting the illumination color

  • on/of night mode

INSTRUCTIONS FOR USAGE

  • Put the humidifier on a flat surface.

  • Remove the top cover, fill water into the water tank, and then put back the top cover. Alternatively, take out the water tank for filling the water, and afterward, put the water tank back on the main base.

  • Check if the rated voltage meets the input voltage, and plug it into the socket.

  • The LED display will flash once and a beep sound will be heard. The humidifier is in the standby state.
    The “ON/OFF” button will be white.

  • Touch the “ON/OFF” button on the control panel to switch on the humidifier, the display will light up and all buttons will be white. The indicator light will be on (with 7-color changing). The display shows the current humidity, current temperature, and the “AUTO” symbol. It means the humidifier works under AUTO MODE.

  • Humidifier will decide on running humidity based on the current temperature as below table. The heating, UV, and timer function is optional.timberk-T-HU6-A19E-W-Ulrtasonic-Humidifier-fig- \(23\)

  • Touch the “MIST OUTPUT” button to adjust the mist output, meanwhile “AUTO” symbol will disappear. = level 1, = level 2, = level 3.

  • Long touch the “MIST OUTPUT” button to enter NIGHT MODE. The display will become dim and show the NIGHT MODE symbol , the indicator light will be off. 10 seconds later, the whole display will be off except the NIGHT MODE symbol . There is no operative sound and waterless warning sound under this mode. Long touch the button again to exit NIGHT MODE.

  • Touch the “HUMIDITY” button to set your expected humidity from 30%RH to 75%RH, display will show a symbol . Touch once, it will increase by 5%RH.

  • The LED display will flash the expected humidity three times and then turn back to show the current humidity. The humidifier enters into the constant humidity function, the expected humidity is set.

  • Under constant humidity function, the humidifier will adjust the mist output level automatically.

  • When the expected humidity is 1%RH ~ 10%RH higher than the current humidity, the humidifier works in level 1.

  • When the expected humidity is 10%RH ~ 15%RH higher than the current humidity, the humidifier works in level 2.

  • When the expected humidity is 15%RH higher than the current humidity, the humidifier works in mist output level 3.

  • When the expected humidity is less than the current humidity, the device will be in a sleeping state. (Timer function is still working under this state.)

  • When the expected humidity is higher than the current humidity, the humidifying function will work again.

  • Touch the button till the LED display shows “Co”, or long touch the button, it means to cancel the humidity setting and back to AUTO MODE.

  • Touch the “TIMER” button to set your desired working time from 01-12 hours. Touch till display shows “Co” or long touch the button , it means to cancel the timer setting.

  • First, touch the “UV” button to start the “HEATING” function, the display will show the HEATING symbol as well. Second, touch the button to start the “UV” function, and the display will show the UV symbol . Third touch to cancel the “HEATING” function. Forth touch to cancel the “UV” function.

  • First, touch the “INDICATOR LIGHT” button , and the indicator light will be green. The second touch light will be blue. The third touch light will be warm yellow. Forth touch light will be 7-color changing. Long touch the button to turn on/off the light.

  • Auto Shut-Off: Once the water in the basin is too little to keep the humidifier working, the humidifier will automatically stop working and have 3 beep sounds (No sound under NIGHT MODE). The display will only show a waterless symbol and the “ON/OFF” button will be white. Refill the water tank, touch the “ON/OFF” button or unplug then plug in again to restart.

  • During working, remove the water tank, the humidifier will stop working and the “ON/OFF” button will be white. Put back the water tank, the humidifier will work again.

AROMA BOX

  • Press out the aroma box from the base.
  • Use water-soluble aroma oil and drop on onto the sponge.
  • Put the aroma box back into the humidifier, the aroma function will remain on when the humidifier is running.
  • To stop the aroma function or when storing the humidifier, clean the sponge in the aroma box.
  • Only drop the aroma oil into the aroma cotton. Do not drop any liquid except clean water into the water tank or basin.timberk-T-HU6-A19E-W-Ulrtasonic-Humidifier-fig- \(22\)

CLEANING AND MAINTENANCE

  • Before cleaning the appliance, make sure it is unplugged. Otherwise, it may result in electric shock.
  • Before cleaning, in order not to burn your hands, wait until the water in the base of the appliance has completely cooled.
  • Use a damp and soft cloth to wipe the outside of the appliance.
  • To avoid electric shock, do not scratch or damage the components of the device when cleaning.
  • Do not use solvent, gasoline, dimethylbenzene, hard brush, talcum powder and other substances when cleaning the device.
  • Wipe off any remaining water inside the base of the unit under the tank with a damp and soft cloth.
  • To remove water on small parts, you can use a brush and then wipe them again with a soft cloth.
  • Clean the device once or twice a week.
  • If dirt is formed on the membrane, clean it with a brush.
  • Rinse the water tank cover and nozzle carefully and effortlessly with fresh water, otherwise, this will cause water to leak through the cover.
  • After removing any remaining water from the surface of the nozzle, wipe it with a soft cloth.
  • Clean the outside of the appliance with a damp and soft cloth.

IMPORTANT!

  • To avoid deformation of working surfaces, resulting in decreased atomizing or other malfunctions, do not use metallic brushes, blades or talc powder to wipe the atomizer’s surface.
  • The water tank may leak after heavy impacts.
  • In case of water leakage, immediately stop using the unit and contact an authorized service center.
  • To keep the unit dry, wipe the water after cleaning and dry the unit’s base and water tank. Make sure that there is no water left inside the unit’s base and water tank.
  • Before a long break in use, dry the base and the tank, put the tank on the base and pack the device in a plastic bag, then put it in a box.
  • Store the unit in a low-humidity room.
  • Storing the unit undried results in the generation of mold.

To clean the water tank and parts of the base of the device from salt deposits, use citric acid:

  • for 1 liter of hot water, take 1 tablespoon of citric acid and mix well;
  • pour the solution into the tank and put it on the base of the humidifier (water from the tank will automatically fall into the base of the device);
  • leave the humidifier for 10-12 hours – do not turn it on;
  • after the time has passed, remove the solution from the device along with the exfoliated parts of the salt coating;
  • if it is difficult to remove plaque – use a special brush for the base of the humidifier (if this is not supplied, you can use a toothbrush). For the tank – pour 0.5-1 cups of dry rice into cold water or a cooled citric acid solution and shake until the plaque is peeled off;
  • rinse all internal parts of the device with cool water;
  • use a humidifier as usual after the procedure.

How to clean the ceramic filter:

  • Clean and activate the ceramic ball filter after using 1000L water regularly. Depending on water quality, if ceramic balls are dirty, the filter needs to be cleaned more frequently.
  • It can be dipped in vinegar for about 5 minutes. Then rinse it clean with clean water.
  • Put the filter under the sun for 4~6 hours.
  • You can purchase replacement filters.

TROUBLESHOOTING

Malfunction

|

Possible cause

|

Solution

---|---|---
Poor atomizing (insufficient productivity)| The unit is operating in

the low atomizing mode (low atomizing frequency)

| It is not a malfunction. Switch the device into the intensive mode of operation
The atomizer is clogged| Clean the atomizer.
The temperature of water in the tank is low| Set maximum productivity mode. The humidifier’s productivity will go up after a while.
No atomizing| The power cord is poorly

connected to the outlet

| Connect the power cord into

the outlet carefully

There is white patches from the water on objects around the humidifier (salts, separating out

from water)

| White patches have formed on the membrane| Clean the humidifier’s membrane with a special brush
There is a lot of salts in the water

(calcium and magnesium)

| Use filtered water


Steam has a bad smell

| Stale water is used| Clean the unit according to the cleaning and servicing instructions and fill the tank

with fresh and filtered water

Remains of stale water or waste have accumulated in the unit’s

case or the atomizer

During the operation of the device, condensate is forming on the upper part of the humidifier and on surrounding objects| High humidification intensity is set.| ****

Decrease the humidification intensity

Room humidity and

room temperature are high




During the operation of the device, water appears next to it

| High humidification intensity is set.| Decrease the humidification intensity


The water tank is badly installed on the unit’s base and there is a gap between them.

| Turn off the unit and make sure the water tank is installed correctly on the base, without any gaps between the tank and the

base.

White patches have formed on the membrane and in grooves for water (in the unit’s base).| Clean the unit according to the cleaning and servicing instructions.
Water appears next to the humidifier when it is off| The water tank is leaking| Contact an authorized service center

STORAGE

  • Before storage makes sure that the appliance is disconnected from the power source.
  • Perform all actions described in the “CLEANING AND MAINTENANCE” section.
  • Wash and dry the appliance, place it in the original package, and store it in a dry place.

UTILIZATION RULES

After the lifetime of the device expires, it should be recycled in compliance with the laws, rules, and methods in the region of recycling. Detailed information about the recycling of the device, can receive from a representative of the local authorities, after providing full information about the device. The manufacturer and authorized organization of the manufacturer do not carry responsibility for the fulfillment by the Buyer of the requirements of legislation on utilization and methods of utilization of the device selected by the Buyer. The lifetime of the device is indicated in the warranty card. The warranty period for the device and warranty terms are specified in the warranty card. The warranty card is an integral part of the documentation supplied with this unit. If there is no warranty card in the delivery set, ask for it from the Seller. The warranty card provided by the Seller must conform to the manufacturer’s form.

The manufacturer and the authorized organization of the manufacturer remove responsibility for any possible harm which can be caused to people, animals or property directly or indirectly if this harm occurred as a result of noncompliance with the rules and operating conditions, installation of the device, intentional or reckless actions of the user- and/or third parties, as well as in situations caused by natural and/or anthropogenic accidents.

www.timberk.ru.

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals