UniGuard Ultrasonic Fuel Sensor User Manual

June 9, 2024
UniGuard

UniGuard Ultrasonic Fuel Sensor

UniGuard-Ultrasonic-Fuel-Sensor

Introduction

Ultrasonic fuel sensor uses ultrasound technology to monitor the level height of fuel or liquid without tampering the tanker. It is widely used to connect with GPS tracking device to realize real time fuel consumption monitoring or fuel amount monitoring during transportation.

Sensor Specification

Specs Description Remark
Installation Tank bottom () Use glue and bracket
Working Voltage DC12-48V
Working Current ≤ 25mA
Measure Range 46 to 1000 mm Default 100cm. Adjustable.
Measure Resolution 0.1mm
Penetration thickness ≤20 mm
Ex Certification Exia IICT6
Working Temperature -40 to 75 °C
Storage Temperature -45 to 80 °C
Interface RS232/RS485/Analog
Interface baud rate 9600 bit/s Adjustable. 8M wire.
Wire Definition Black-GND, Red-Power

Yellow: 0-5V, connect with GPS speed limiter UT04s Grey wire Yellow-TX/B, RX/B-connect device.

Green-RX/A, TX/A connect device

Weight| 0.45KG

Sensor Size

UniGuard-Ultrasonic-Fuel-Sensor-1

Features

  • No tamper of tanker by using ultrasound
  • Attached installation, fast, easy and firm
  • Support working voltage at 5V or 9V to 36V
  • Support RS232/RS485/0 5V signal output
  • Super strong ultrasound penetration to work at tanker thickness below 20mm. Normal tanker thickness is b elow 8mm.
  • Builtin interference proof algorithm, smart and efficient

Application

  • Fuel consumption remote monitoring for any type of vehicle, truck or car
  • Dangerous liquid transpiration monitoring
  • Construction vehicle fuel usage monitoring
  • Water truck monitoring
  • Storage tanker monitoring

Package

  • 1x ultrasonic fuel sensor
  • 1x 8 meter extension cable
  • 1x installation bracket with screws
  • 1xabrasive paper
  • 5x plastic ribbon for wire fixing
  • 1x display for liquid height display (optional)

UniGuard-Ultrasonic-Fuel-Sensor-2

Before Installation

Please make sure take display and power bank for sensor installation.

Display Usage
Display is connected with sensor head and powered by power bank so as to show current tanker fuel height. If the displayed height is same as current fuel amount height, it means the current installation spot is right.

Before installation

  • Park vehicle on flat road
  • The height of current fuel amount in tank should be higher than 6cm, for construction vehicle or boat, the height must be higher than 12cm
  • The installation spot is advised to be at the middle bottom of tank.
  • The installation spot must be smooth, clean and clear.

Installation

Locate installation spot

UniGuard-Ultrasonic-Fuel-Sensor-3

  • Put some couplant in the middle of sensor head
  • Couplant is in the circle area
  • Check if height display is right ,otherwise make sure the tank is smooth, clean and clear.

S ensor installation

UniGuard-Ultrasonic-Fuel-Sensor-4

Bracket installation

UniGuard-Ultrasonic-Fuel-Sensor-5

3.4 Paste waterproof glue

  1. area among sensor and bracket, paste waterproof glue
  2. area outside of the bracket, paste AB glue to strength bracket
  3. Display is always connected during the installation.

Power sensor and connect device

  1. Sensor Black for GND, Red for Power.
  2. Yellow: 0 5V is to connect with GPS speed limiter UT04s Grey wire.

Add: 405, Xinhui Business Bld, Xinwei 3rd Industry Area, GuangMing, Shenzhen, China
Email: [email protected]
Web: https://uniguardgps.com

Copyright 2008-2022 UniGuard Technology Limited. All Rights Reserved www.uniguardgps.com

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

UniGuard User Manuals

Related Manuals