NOVUS NVIP-5VE-6202M-II Vandal Proof IP Camera with Motor User Guide
- June 9, 2024
- Novus
Table of Contents
Quick start guide
NVIP-5VE-6202M-II
NVIP-5VE-6202M-II/7043
Vandal Proof IP Camera with Motor
NVIP-5VE-6202M-II Vandal Proof IP Camera with Motor
IMPORTANT SAFEGUARDS AND WARNINGS
THE PRODUCT MEETS THE REQUIREMENTS CONTAINED IN THE FOLLOWING DIRECTIVES:
DIRECTIVE 2014/30/EU OF THE EUROPEAN PARLIMENT AND OF THE COUNCIL of 26
February 2014 on the harmonisation of the laws of the Member States relating
to electromagnetic compatibility (OJ L 96, 29.3.2014, p. 79–106, with
changes).
DIRECTIVE 2012/19/EU OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL of 4 July
2012 on waste electrical and electronic equipment WEEE) (OJ L 197, 24.7.2012,
p. 38–71,with changes).
DIRECTIVE 2011/65/EU OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL of 8 June
2011 on the restriction of the use of certain hazardous substances in
electrical and electronic equipment (OJ L 174, 1.7.2011, p. 88–110, with
changes).
COMMISION DELEGATED DIRECTIVE (EU) 2015/863 of 31 March 2015 amending Annex II
to Directive 2011/65/EU of the European Parliament and of the Council as
regards the list of restricted substances.
DIRECTIVE (EU) 2017/2102 OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL of 15
November 2017 amending Directive 2011/65/EU on the restriction of the use of
certain hazardous substances in electrical and electronic equipment.
Information
The device, as a part of professional CCTV system used for surveillance and
control, is not designed for self installation in households by individuals
without technical knowledge.
Excluding of responsibility in case of damaging data on a disk or other
devices:
The manufacturer does not bear any responsibility in case of damaging or
losing data on a disk or other devices during device operation.
WARNING!
PRIOR TO UNDERTAKING ANY ACTION THAT IS NOT DESCRIBED FOR THE GIVEN PRODUCT IN
USER’S MANUAL AND OTHER DOCUMENTS DELIVERED WITH THE PRODUCT, OR IF IT DOES
NOT ARISE FROM THE USUAL APPLICATION OF THE PRODUCT, MANUFACTURER MUST BE
CONTACTED UNDER THE RIGOR OF EXCLUDING THE MANUFACTURER’S RESPONSIBILITY FOR
THE RESULTS OF SUCH AN ACTION.
Pictures in this publication showing camera views can be simulations. Actual
camera images may vary depending on the type, model, settings, observation
area, or environmental conditions.
WARNING!
THE KNOWLEDGE OF THIS MANUAL IS AN INDESPENSIBLE CONDITION OF A PROPER DEVICE
OPERATION. YOU ARE KINDLY REQUSTED TO FAMILIRIZE YOURSELF WITH THE MANUAL
PRIOR TO INSTALLATION AND FURTHER DEVICE OPERATION.
WARNING!
USER IS NOT ALLOWED TO DISASSEMBLE THE CASING AS THERE ARE NO USER
-SERVICEABLE PARTS INSIDE THIS UNIT. ONLY AUTHORIZED SERVICE PERSONNEL MAY
OPEN THE UNIT
INSTALLATION AND SERVICING SHOULD ONLY BE DONE BY QUALIFIED SERVICE PERSONNEL
AND SHOULD CONFORM TO ALL LOCAL REGULATIONS
-
Prior to undertaking any action please consult the following manual and read all the safety and operating instructions before starting the device.
-
Please keep this manual for the lifespan of the device in case referring to the contents of this manual is necessary;
-
All the safety precautions referred to in this manual should be strictly followed, as they have a direct influence on user’s safety and durability and reliability of the device;
-
All actions conducted by the servicemen and users must be accomplished in accordance with the user’s manual;
-
The device should be disconnected from power sources during maintenance procedures;
-
Usage of additional devices and components neither provided nor recommended by the producer is forbidden;
-
You are not allowed to use the camera in high humidity environment (i.e. close to swimming pools, bath tubs, damp basements);
-
Mounting the device in places where proper ventilation cannot be provided (e. g. closed lockers etc.) is not recommended since it may lead to heat build-up and damaging the device itself as a consequence;
-
Mounting the camera on unstable surface or using not recommended mounts is forbidden.
Improperly mounted camera may cause a fatal accident or may be seriously damaged itself. The camera must be mounted by qualified personnel with proper authorization, in accordance with this user’s manual. -
Device should be supplied only from a power sources whose parameters are in accordance with those specified by the producer in the camera technical datasheet. Therefore, it is forbidden to supply the camera from a power sources with unknown parameters, unstable or not meeting producer’s requirements;
Due to the product being constantly enhanced and optimized, certain parameters
and functions described in the manual in question may change without further
notice.
We strongly suggest visiting the
www.novuscctv.com/en website in order to access
the newest full manual
FOREWORD INFORMATION
1.1. General Characteristics
- Sensor resolution: 5 megapixels
- Mechanical IR cut filter (IR operation capability)
- Min. Illumination from 0 lx with IR LED on
- Wide Dynamic Range (WDR) for enhanced image quality in diverse light conditions
- Digital Noise Reduction (DNR)
- Highlight Compensation (HLC)
- Back Light Compensation (BLC)
- Reduction of image flicker (Antiflicker)
- Lens type: motor-zoom, f = 2.8~12mm/F1.4
- Built-in LED illuminator
- Built-in webserver: camera configuration through the website
- Video compression: H.264, H.265, H.264+, H.265+, MJPEG / G711
- Max. video resolution up to 2880×1620
- Multi streaming: compression, resolution, speed and quality defined individually for each video stream
- ROI functions
- Motion detection
- Private Zones
- RTSP protocol support for video transmission
- Schedule
- Micro SD card up to 256GB
- Wide range of responses to alarm events: e-mail with attachment, saving file on FTP server, saving file on microSD card
- Electronic Shutter from 1/2 s to 1/100 000 s.
- Supports up to 3 streams
- ONVIF Protocol Support
- Software: NMS (NOVUS MANAGEMENT SYSTEM) for video recording, live monitoring, playback and remote IP devices administration
- Power supply: 12 VDC / PoE
1.2. Technical specification
IMAGE
Image Sensor| 5 MPX CMOS sensor 1/2.7” SmartSens
Number of Effective Pixels| 2884 (H) x 1624 (V)
Min. Illumination| 0.005 lx/F1.4 – color mode, 0 lx (IR on) – B/W mode
Electronic Shutter| auto/manual: 1/2 s ~ 1/100000 s
Digital Slow Shutter (DSS)| up to 1/2 s
Wide Dynamic Range (WDR)| yes 120dB
Digital Noise Reduction (DNR)| 2D, 3D
Highlight Compensation (HLC)| yes
Back Light Compensation (BLC)| yes
Reduction of image flicker (Antiflicker)| yes
LENS
Lens Type| motorized, auto-iris function, f=2.8 ~ 12 mm/F1.4
Auto-focus| zoom trigger, day/night mode trigger, manual trigger
DAY/NIGHT
Switching Type| mechanical IR cut filter
Switching Mode| auto, manual, time
Switching Level Adjustment| yes
Switching Delay| 2 ~ 120 s
Switching Schedule| yes
Visible Light Sensor| yes
NETWORK
Stream Resolution| 2880 x 1620, 2560 x 1440 (QHD), 2304 x 1296, 1920 x 1080
(Full HD), 1280 x 720 (HD), 704 x 576, 704 x 480, 640 x 480 (VGA), 480 x 240,
352 x 288 (CIF), 352 x 240
Frame Rate| 30 fps for each resolution
Multistreaming Mode| 3 streams
Video/Audio Compression| H.264, H.264+, H.265, H.265+, MJPEG/G.711
Number of Simultaneous Connections| max. 10
Bandwidth| 60 Mb/s in total
Network Protocols Support| HTTP, IPv4, IPv4/v6, UDP, HTTPS, FTP, DHCP, DDNS,
NTP, RTSP, RTP, UPnP, SNMP, QoS, IEEE 802.1X, PPPoE, SMTP, RTCP, RTMP
ONVIF Protocol Support| Profile S
Camera Configuration| from Internet Explorer, Firefox, Chrome, Opera browser
languages: Polish, English, and others
Compatible Software| NMS, N Control 6000
Mobile applications| SuperLive Plus (iPhone, Android)
OTHER FUNCTIONS
Privacy Zones| 4 video mask type: single color
Motion Detection| yes
Region of interest (ROI)| 8
Video Content Analysis (VCA)| abandoned object, object disappearance, line
cross, Scene Change, intrusion detection
Image Processing| sharpening, mirror effect, corridor mode, vertical flip,
horizontal flip
Prealarm/Postalarm| up to 6 s/up to 120 s
System Reaction to Alarm Events| e-mail, e-mail with attachment, saving file
on FTP server, saving file on SD card
Restoring default settings| via web browser, using reset button, via NMS
IPTool software
IR LED
LED Number| 2
Range| 50 m
Smart IR| yes (software support)
INTERFACES
Audio Input/Output| 1 x Jack (3.5 mm)/- built-in microphone
Network Interface| 1 x Ethernet – RJ-45 interface, 10/100 Mbit/s
Memory Card Slot| microSD – capacity up to 256GB
INSTALLATION PARAMETERS
Dimensions (mm)| 112 (Ф) x 100 (H)
Weight| 0.7 kg
Degree of Protection| IP 67 (details in the user’s manual)
Enclosure| vandalproof IK10 impact rating aluminium, white or grey (NVIP-5VE-
6202M-II/7043)
Power Supply| PoE, 12 VDC
Surge protection| TVS 4000 V
Power Consumption| 5 W, 9 W (IR illuminator on)
Operating Temperature| -30°C ~ 60°C
Humidity| max. 95%, relative (non-condensing)
1.3. Camera dimensions (mm)
Camera NVIP-5VE-6202M-II 1.4. Package contents
After opening the package make sure that the following elements are inside:
- IP camera
- Accessories bag
- Short version of user’s manual
If any of this elements has been damaged during transport, pack all the
elements back into the original box and contact your supplier for further
assistance.
CAUTION!
It is forbidden to use – as the camera power source – PoE equipment (adapters,
etc.) not compatible with IEEE 802.3af standard (items called “passive PoE
power supply”). Damages caused by the usage of improper power supply source
are not covered by the warranty.
START-UP AND INITIAL IP CAMERA CONFIGURATION
2. START-UP AND INITIAL IP CAMERA CONFIGURATION
CAUTION!
If the device was brought from a location with lower temperature, please wait
until it reaches the temperature of location it is currently in. Turning the
device on immediately after bringing it from a location with lower ambient
temperature is forbidden, as the condensing water vapour may cause short-
circuits and damage the device as a result.
Before starting the device familiarize yourself with the description and the
role of particular inputs, outputs and adjusting elements that the device is
equipped with.
2.1 Description of connectors and control tools
- 100 Mb/s Ethernet port (PoE RJ-45 connector)
- Audio input (Jack 3.5 mm)
- Power supply 12VDC
- Counter nut
- Base of camera
- Built-in microphone
- MicroSD card slot
- Reset button
2.2. Ethernet cable connecting
To maintain tightness of ethernet cable connection, please follow instruction
below:
- Unscrew the nut (1) from the connector cover (2).
- Route the network cable (without the RJ-45 plug) through the components (1) and (2), than crimp the RJ-45 connector.
- Plug the RJ-45 connector into the hermetic socket (3), screw the connector cover (2), and than the nut (1).
CAUTION!
The declared degree of protection of the camera relates to its housing and
does not take into account the possibility of moisture infiltration into the
camera by connection cables. Connection cables protection through i.e. sealing
up is the camera installer duty. The manufacturer is not liable for any camera
damages caused as a result of failing in performing that activity by
installer, which also means that camera damaged in that way is not subject to
warranty repairs.
CAUTION!
Camera power supply connector is not hermetic. Installer should seal this
connector by himself.
Camera can be supplied using external power supply unit corresponding with the
camera parameters or by using RJ45 network socket and PoE (802.3af) power
supply unit. If you’re using external power supply please connect wires
according to polarisation shown on picture:
Scheme of 12VDC power supply connector CAUTION!
In order to provide protection against voltage surges/lightning strikes, usage
of appropriate surge protectors is advised. Any damages resulting from surges
are not eligible for service repairs.
2.3. Camera mounting
To mount a camera please follow the instructions below:
- Unscrew the counter screw (4).
- Remove the camera cover (3), remove the camera from the base (5).
- Put the bracket to the wall in a desired mounting place (with cable hole). Take the drill pattern and mark future drilling holes for screws and wires.
- Drill holes for screws, wires and base.
- Mount the camera base (5) using the supplied plugs and screws.
- If necessary, unscrew the camera service panel (1), mount microSD card in the socket (2) and screw the camera service panel (1).
- Connect the camera wires, put camera on the base (5), attach the cover (3) and pre-tighten the counter screw (4).
- Adjust camera position.
- Tighten to the stop counter screw (4).
CAUTION!
Please note that the wall or ceiling must have enough strength to carry the IP
Camera.
CAUTION!
In order to obtain declared degree of protection please seal the camera
bracket to prevent water getting inside. Furthermore, when installing the
bracket on rough/uneven surfaces, please additionally seal the junction with
appropriate sealing mass. Please pay special attention to any mounting holes
and if they are a loop-through ones, seal them too.
2.4. Starting the IP camera
To run NOVUS IP camera you have to connect ethernet cable between camera and
network PoE switch with PoE support (IEEE 802.3af).
You can also power it from 12VDC power supply compatible with camera power
supply specification.
The recommended way to start an IP camera and perform its configuration is a
direct connection to the network switch which is not connected to other
devices. To obtain further information about network configuration parameters
(IP address, gateway, network mask, etc.) please contact your network
administrator.
-
Connection using network switch with PoE support
-
Connection using external power supply and network switch
-
Connection using external power supply directly to the computer
Information:
Power supply adapter is not included. Please use power adapter with parameters
specified in user ‘s manual.
2.5. Initial configuration via the web browser
The default network settings for NVIP-5VE-6202M-II camera are :
- IP address= 192.168.1.200
- Network mask – 255.255.255.0
- Gateway – 192.168.1.1
- User name – root
- Password – pass
Knowing the camera’s IP address you need to appropriately set PC IP address,
so the two devices can operate in one network subnet ( e.g. for IP
192.168.1.1, appropriate address for the camera ranges from 192.168.1.2 to
192.168.1.254, for example 192.168.1.60). It is not allowed to set the same
addresses for camera and PC computer.
You can either set a network configuration (IP address, gateway, net mask,
etc.) of NOVUS IP camera yourself or select DHCP mode (DHCP server is required
in this method in target network) by using web browser or by NMS software.
When you use DHCP server check IP address lease and its linking with camera
MAC address to avoid changing or losing IP address during device operation or
network/ DHCP server breakdown. You have to remember to use a new camera IP
address after changing network parameters.
After network setting configuration has been done, the camera can be connected
to a target network.
2.6. Security recommendations for network architecture and configuration
CAUTION!
Below are shown security recommendations for network architecture and
configuration of CCTV systems that are connected to the Internet to reduce the
risk of unauthorized interference with the system by a third party.
-
Absolutely change the default passwords and user names (if the device gives this possibility) of all applied network devices (recorders, cameras, routers, network switches, etc.) to the severely complexity password. Use lowercase and uppercase letters, numbers, and special characters if there is such possibility.
-
Depending on the available functionality in the order to restrict access to the used network devices at the administrator account level, it is recommended to configure the users accounts accordingly.
-
Do not use DMZ function (Demilitarized zone) in your router. Using that function you open the access to recorder system from the Internet on all ports, which gives possibility for an unauthorized interference with the system.
Instead of DMZ use port forwarding redirect only the ports which are necessary for the performance of the connection (detailed information about ports of communication in different models of recorders, cameras, etc. can be found in the operating instructions). -
Use routers with firewall function and make sure it is enabled and properly configured.
-
It is recommended to change the default network communication port numbers of used devices if there is such possibility.
-
If used network devices has a UPnP feature and it is not used, turn it off.
-
If used network devices has a P2P feature and it is not used, turn it off.
-
If used network devices support HTTPS protocol for connection, it is recommended to use it.
-
If used network devices support IP filtering for authorized connections function, it is recommended to use it.
-
If used recorder has two network interfaces it is recommended to use both of them to physically separate network for cameras and network for Internet connection. The only device in the system, accessible from Internet will be recorder – there will be no physically access directly to any camera.
NETWORK CONNECTION USING WEB BROSWER
3.1. Recommended PC specification for web browser connections
Requirements below apply to connection with an IP camera, assuming smooth
image display in 2880×1620 resolution and 30 fps speed.
- CPU Intel i7 3 GHz
- RAM Memory min. 6 GB
- VGA card Nvidia GeForce 1GB
- Operating System Windows 10
- Network card 100/1000 Mb/s
3.2. Connection with IP camera via web browser
-
Connecting to the camera for the first time
Enter the IP address of the camera (default 192.168.1.200) in the address bar of the web browser. If the address is correct and the target device is currently available, the first connection window will be displayed. In this window, user should read the privacy statement and after reading it, select the checkbox next to the Already Read button, and press this button.
The acceptance of the privacy statement cannot be omitted. This window only appears the first time you log in, but it can be displayed again at any time.
Access to the privacy statement can be found in the menu Config > System > Basic information > Privacy statement. -
Device Activation
After accept privacy statement, device activate window appears. In this window user has to set a password for the web account.
Check the “Activate Onvif user” checkbox to change the password for the Onvif account to the same password as for the web account.
If the user assigns a new password during the device activation but does not check the Activate Onvif User” checkbox, the Onvif account will remain with the default login data (login: root and password: pass).
The password can be up to 16 characters long. While password is entered
strength of it displaing on an ongoing basis by the security level indicator.
To ensure the good security of the password, use upper and lower case letters,
numbers and special characters. After entering the correct password twice and
confirming it with the OK button, the administrator password will be saved,
the window will close and the login screen will be displayed.
• User accounts
The acceptance of the privacy statement cannot be omitted. This window only
appears the first time you log in, but it can be displayed again at any time.
The Web account is the administrator account created during the activation of
the device. It means that the user logging in, by using the root login and a
predefined password and have access to the full functionality and all
available settings in the camera. The account is also used to log in to the
camera via the 6000 series network recorders and NMS (Novus Management System)
software using the LongPolling event method.
The Onvif account is an account used to log in to the camera via the NMS
software (Novus Management System) or using the Onvif or the RTSP protocol.
This account is created automatically during activation of the device, and the
default login data are login: “root” and password: “pass”.
For security reasons, immediately change the default password for the Onvif
account after activating the device. It is recommended to set the same
password in both accounts: the Onvif account and the web account.
• Onvif account edition
In order to change the Onvif account password, after logging in, go to the
Settings tab in the upper right corner and then Network > Onvif.
In the Onvif tab, click the Modify button, then in the Edit User window, enter
the new password and confirm with OK button. If the connection to the camera
via the NMS software is using the LongPolling event handling method, the same
password for the Onvif account as for the Web account must be set in this
step. In order to delete the Onvif
account, select the user by clicking on the appropriate row in the table, then
click Delete button. Please note that deleting Onvif account means that the
camera cannot be added to NMS software. Add button is used to create new Onvif
account.
• Logging in to the camera for the first timeIn this window, in order to login to camera, enter the user
name root and the newly set administrator password. In the Stream type field
user can select the stream that is displayed in the live view window after
login. The Language field allows to change the interface language. The Forget
Password option allows to log in to the camera if you forget the administrator
password and for this is required to know the answers to the security
questions (set in the next step).
After entering appropriate data, click the Login button to login to the web
panel of the camera.
• Safety questions
The next step in logging in for the first time is entering answers to the
security questions.
In the window that appears, select questions from among those available on the
list and enter your own answers.
Knowing the right answers is essential to recovering the administrator
password.
This step cannot be omitted.
The security question window is displayed only during the first login, and the
only possibility to change the given answers is to restore the factory
settings and go through all stages of the first connection with the camera.
• Plug-in installation
If the browser has no connected to any of the 6000 series cameras so far,
or if an older version of the plug-in is installed, a message will be
displayed in the remote viewing window that the appropriate plug-in version
must be installed. ![NOVUS NVIP 5VE 6202M II Vandal Proof IP Camera with Motor
- Figure 10](https://manuals.plus/wp-content/uploads/2023/02/NOVUS-NVIP-5VE-
6202M-II-Vandal-Proof-IP-Camera-with-Motor-Figure-10.jpg)To start plug-in installation, click Here button.
Then the browser displays a window asking how to proceed with the
NetAIIPCamera.exe file. Press the Run button to start the plug-in installer.
In the installer window, select the installation language (English by default) and then click Install button to install plug-in. After installation click the Finish button to close the installer and refresh the browser window (you can also close and restart the browser).
If after installation and browser window refresh, the same text appears on the screen, go to the browser Tools (the gearwheel icon in the top right corner), then click Menage add-ones. In the window that appears click right mouse button on the NetAIIPCamera Control, then click the Enable option and refresh the browser window.
After completion all of the above steps, preview of the camera in the live view window should appears.
WWW INTERFACE – WORKING WITH IP CAMERA
4.1 Displaying live video
-
Camera menu:
• Live – opens the camera live video,
• Config – opens the camera configuration menu,
• Search – opens the camera playback,
• Chart – opens the intelligent image analysis statistics window. -
The buttons for changing the displayed stream and fluency:
Allow to change the displayed stream to Main stream, Sub stream.
Allow you to choose between Real-time, Balanced and Fluent fluency. -
Alarm icons – icons showing the current status of some camera alarms.
-
Live video window
-
Image settings buttons – these buttons change the picture display mode in the live video preview
| Original size| | Adapt
---|---|---|---
| Proper size| | Full screen
All rights reserved © AAT SYSTEMY BEZPIECZEŃSTWA Sp. z o.o.
- Function buttons:
Start/stop live view| | Enable/disable audio|
---|---|---|---
Snapshot| | Start Recording|
Zoom In (digital)| | Zoom out (digital)|
Lens control| | Enable/disable graphical representation of image analysis|
ELECTRIC CONNECTORS AND ACCESORIES
5.1. MicroSD card installation
Camera supports microSD cards up to a maximum size of 256GB. In order to
install the card properly, please follow the instructions below:
- Turn off the camera power.
- Unscrew the camera service panel (1).
- Mount microSD card in the socket (2).
- Screw the camera service panel (1).
- Turn on the camera.
- Check the SD card by checking its capacity in the “System” -> “SD Card” tab.
FACTORY SETTINGS RESTORING
Restoring factory settings of the IP camera restores all default settings. This process takes about two minutes. NOVUS NVIP-5VE-6202M-II cameras allow to restore defaults via:
- software (via web browser )
- software (via NMS IPTool)
- hardware (using reset button (RST))
6.1. Software factory settings restoring via web browser
Restoring factory settings via web browser allows you to optionally keep some
settings, such as network settings. To restore default settings go to:
“Maintenance -> Backup and Restore” tab.
6.2. Software factory settings restoring via NMS IPTool
NMS IPTool (version 3.5 or later) allows to restore factory settings. To
restore settings via NMS IPTool, find the camera in the list of available
devices and then, on the right side of the row click .
Then within 30 seconds disconnect power of the camera. After reconnecting the
camera, all settings are factory default. 6.3. Hardware factory settings restoring
In order to restore factory settings using reset button (RST), please follow
the instructions below:
- Unscrew the camera service panel (1).
- Press the reset button (2) and hold on for 10 seconds.
- Release button
- Screw the camera service panel (1).
- Log on after 2 minutes using default IP address (http://192.168.1.200) and default user name (root) and password (pass).
NOTES ——
AAT SYSTEMY BEZPIECZEŃSTWA Sp. z o.o.
431 Pulawska St., 02-801 Warsaw, Poland
tel.: +4822 546 0 546, kontakt@aat.pl
www.novuscctv.com
2022-08-04 DK TF
References
- NOVUS Professional solution for your security systems | Video surveillance (CCTV), Access control
- NOVUS Professional solution for your security systems | Video surveillance (CCTV), Access control
- NOVUS Profesjonalne rozwiązanie dla systemów zabezpieczeń | Telewizja przemysłowa CCTV, Kontrola dostępu
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>