GE APPLIANCES DSDR24F Electric Dryers Stand Instruction Manual

June 9, 2024
GE Appliances

GE APPLIANCES logo DSDR24F Electric Dryers Stand
Instruction Manual Installation Instructions

DSDR24F Electric Dryers Stand

Stack Stand Kit
FOR USE WITH RECOMMENDED COMPACT-TYPE ELECTRIC DRYERS
Questions? Call 800.GE.CARES (800.432.2737) or visit our Web site at: www.GEAppliances.com

BEFORE YOU BEGIN

Read these instructions completely and carefully.

  • IMPORTANT – Save these instructions for local electrical inspector’s use.
  • IMPORTANT – Observe all governing codes and ordinances.
  • Note to Installer – Be sure to leave these instructions with the Consumer.
  • Note to Consumer – Keep these instructions for future reference.
  • Installation and service must be performed by a qualified installer.
  • Proper installation is the responsibility of the installer.

FOR YOUR SAFETY:
WARNING

  • Electric Shock Hazard. Disconnect power before servicing. Failure to do so could result in serious injury or death.
  • Potential Personal Injury. More than one person is recommended to lift the dryer into position because of its weight and size. Failure to do so could result in personal injury or death.
  • Avoid Tipping and Rupture of Utility Services. Stand must be securely assembled and dryer fastened to stand, per installation instructions. Stand must be securely fastened to wall, per installaiton instructions. Failure to do so could result in personal injury/death or property damage.

TOOLS YOU WILL NEED

  • Flat-head screwdriver

  • Adjustable wrench

  • Nut driver

PARTS INCLUDED

PART QUANTITY
Lid Latch 1
Type A Screw 1/4–20 x 3/4 2
Type B Screw 1/4–20 x 1 1⁄2 6
Type C Screw 1/4–10 x 1 3⁄4 2
Type D Screw 10–16 x 5/8 7
Lock Nut 1/4–20 8
Spacer Ring 1

GE APPLIANCES DSDR24F Electric Dryers Stand - fig 11

The stand base has an angle bracket at each end. One end of the angle bracket is 22 1⁄2″ long and has mounting holes in it. This end goes up. The other end of the angle bracket is 28″ long and has no holes. This longer end (without holes) goes down.
DETERMINE STAND WIDTH
Your new stand can be assembled to two different widths:

  • 22″ for smaller, compact washers
  • 24″ for larger washers

Check your washer width to determine the stand width you need. The compact dryer will assemble to either width. GE APPLIANCES DSDR24F Electric Dryers
Stand - fig 12ATTACH WALL MOUNTING BRACKET
Attach one end of the wall mounting bracket to one of the upper rear holes on one of the stand bases using a Type A screw and a lock nut. Make sure screws are inserted from the top and the lock nuts are on the bottom. Use the inside hole on the stand base for 24″ width. Use the outside hole for 22″ width.GE
APPLIANCES DSDR24F Electric Dryers Stand - fig 13Attach the other end of the bracket to the upper rear hole of the other stand base the same way. Use the inside hole on the stand base for 24″ width or the outside hole for
22″ width. Hand-tighten the screws and nuts.
ATTACH DIAGONAL BRACE
Attach the diagonal brace to the back of the front uprights on the stand bases. The brace must run from the lower left to the upper right when viewed from the rear of the stand.
Insert a Type B screw from the front of the stand into the lower hole on the left upright and secure with a lock nut. The lock nut will be on the inside of the upright.
Insert another Type B screw into the hole on the right upright. The top hole is used for 22″ width, and the lower hole is used for 24″ width. Hand-tighten the screws and lock nuts.GE APPLIANCES DSDR24F Electric Dryers Stand - fig
14 ATTACH CROSS BRACE
Attach the cross brace to the rear uprights on the stand bases. Insert two Type B screws from the rear of the stand into the lower holes on the uprights and secure with lock nuts. The lock nuts will be on the insides of the uprights.
Insert two Type B screws into the upper holes on the uprights. The top holes are used for 22″ width, and the lower holes are used for 24″ width. Hand- tighten the screws
and lock nuts.GE APPLIANCES DSDR24F Electric Dryers Stand - fig
15 TIGHTEN LOCK NUTS
Securely tighten all lock nuts using a screwdriver and an adjustable wrench or nut driver.GE APPLIANCES DSDR24F Electric Dryers Stand - fig
16

DETERMINE LOCATION
Locate the stand in an appropriate level area. This location should be suitable for the size, function, and protection of the stack stand and appliances. Use the stack stand only for the purpose for which it was designed. To prevent restriction of airflow, do not use top of dryer for storage.
The proper location of all utility connections is shown in the Utilities and Grounding illustration. These are not all needed in each installation, but those used should be located according to these dimensions so that utilities can be reached after installation. GE APPLIANCES DSDR24F Electric Dryers
Stand - fig 17

Dryers
Dryer models may require different utilities;
refer to the Installation Instructions included with your new dryer for details on required utilities.
Refer to the Utilities and Grounding illustration and the Dryer Installation Instructions for details on final utility connections and grounding information.
NOTE: All fittings and outlets must be located so that they clear cross members of stack stand.
Automatic Washers
All automatic washers require a hot and cold water supply, a proper drain and a 120-volt electrical supply. Refer to the Installation Instructions included with your new automatic washer for detailed installation requirements.
If the automatic washer is to be operated in a different location (portable) and only stored in the stack stand, those utilities marked with an asterisk (*) in the Utilities and Grounding illustration would not be required at this location. They would be required at the location where the automatic washer is to be operated, with the exception of the drain pipe, since the machine can be drained into a sink or laundry tub.
NOTE: If both the automatic washer and dryer require a 120-volt electrical supply, TWO separate 15-ampere circuits must be used (one for each appliance). DO NOT, under any circumstances, connect both appliances to the same circuit as blown fuses will result.
LOCATE MOUNTING HOLES
Push the dryer and stand against the wall in the selected location and locate two wall studs.
Start 2 Type C screws through holes in the mounting bracket that line up with studs. DO NOT SCREW IN ALL THE WAY. Multiple holes in the bracket allow for variation in location of wall studs. GE APPLIANCES DSDR24F Electric Dryers
Stand - fig 18Once the holes are started, remove the screws from the mounting bracket and move the stand away from the wall.
For installations requiring clearance from the wall:
If the stand cannot be pushed all the way against the wall, secure a piece of wood to the wall studs to line up with the holes on the mounting bracket. The wood must be the
same thickness as the clearance. Follow the steps above, starting the screws in the piece of wood. GE APPLIANCES DSDR24F Electric Dryers Stand - fig
19INSTALL DRYER TO STAND
Carefully follow section entitled Preparing Your Dryer for Installation in the Installation Instructions for your new dryer. The dryer weighs approximately 100 pounds.
WARNING
Potential Personal Injury. More than one person is recommended to lift the dryer into position because of its weight and size. Failure to do so could result in personal injury or death.
Use 6 Type D screws to secure the dryer to the stand. Tighten the screws using an adjustable wrench or nut driver. The dryer will sit approximately 11⁄4 ″ forward of the end of the top angle.  GE APPLIANCES DSDR24F Electric
Dryers Stand - fig 20NOTE: The outside holes are used for 22″ width, and the inside holes are used for 24″ width.
MOVE DRYER AND STAND INTO FINAL POSITION AND INSTALL DRYER EXHAUST
Push the dryer and stand against the wall in the selected location.
If the hole for the exhaust has been located as shown in the Utilities and Grounding illustration, it will align with the dryer exhaust when the stack stand and dryer are placed in the selected operating position.GE APPLIANCES
DSDR24F Electric Dryers Stand - fig 21Follow the Installation Instructions included with your dryer to make exhaust connections.
SECURE STAND TO WALL
After the exhaust is connected and the dryer and stack stand are in the selected operating position, secure the stand to the wall using 2 Type C screws in the holes started earlier.GE APPLIANCES DSDR24F Electric Dryers
Stand - fig 22 INSTALL WASHER
Follow the Installation Instructions included with your washer to make washer connections.
After washer connections are made, move the washer into its operating position between the stand side sections and push it completely toward the rear. Use care not to kink or pinch the water inlet hose, and be sure the drain hose is placed in the drain pipe with no kinks or twists.GE APPLIANCES DSDR24F
Electric Dryers Stand - fig 23 INSTALL LID LATCH
If a washer with a lift lid is to be installed and used under the stand, install the washer lid latch as shown using a Type D screw in the hole behind one of the front mounting holes. The lid latch may be installed on either side.
NOTE: The screw for the lid latch will thread into bottom of the dryer. Tighten securely using a nut driver.    GE APPLIANCES DSDR24F Electric
Dryers Stand - fig 24

GE APPLIANCES logo 175D1807P423
49-90159
03-03 JR

Documents / Resources

| GE APPLIANCES DSDR24F Electric Dryers Stand [pdf] Instruction Manual
DSDR24F Electric Dryers Stand, DSDR24F, Electric Dryers Stand, Dryers Stand, Stand
---|---

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

GE Appliances User Manuals

Related Manuals