GE APPLIANCES DSDR24F Electric Dryers Stand Instruction Manual
- June 9, 2024
- GE Appliances
Table of Contents
DSDR24F Electric Dryers Stand
Instruction Manual Installation Instructions
DSDR24F Electric Dryers Stand
Stack Stand Kit
FOR USE WITH RECOMMENDED COMPACT-TYPE ELECTRIC DRYERS
Questions? Call 800.GE.CARES (800.432.2737) or visit our Web site at:
www.GEAppliances.com
BEFORE YOU BEGIN
Read these instructions completely and carefully.
- IMPORTANT – Save these instructions for local electrical inspector’s use.
- IMPORTANT – Observe all governing codes and ordinances.
- Note to Installer – Be sure to leave these instructions with the Consumer.
- Note to Consumer – Keep these instructions for future reference.
- Installation and service must be performed by a qualified installer.
- Proper installation is the responsibility of the installer.
FOR YOUR SAFETY:
WARNING
- Electric Shock Hazard. Disconnect power before servicing. Failure to do so could result in serious injury or death.
- Potential Personal Injury. More than one person is recommended to lift the dryer into position because of its weight and size. Failure to do so could result in personal injury or death.
- Avoid Tipping and Rupture of Utility Services. Stand must be securely assembled and dryer fastened to stand, per installation instructions. Stand must be securely fastened to wall, per installaiton instructions. Failure to do so could result in personal injury/death or property damage.
TOOLS YOU WILL NEED
-
Flat-head screwdriver
-
Adjustable wrench
-
Nut driver
PARTS INCLUDED
PART | QUANTITY |
---|---|
Lid Latch | 1 |
Type A Screw 1/4–20 x 3/4 | 2 |
Type B Screw 1/4–20 x 1 1⁄2 | 6 |
Type C Screw 1/4–10 x 1 3⁄4 | 2 |
Type D Screw 10–16 x 5/8 | 7 |
Lock Nut 1/4–20 | 8 |
Spacer Ring | 1 |
The stand base has an angle bracket at each end. One end of the angle bracket
is 22 1⁄2″ long and has mounting holes in it. This end goes up. The other end
of the angle bracket is 28″ long and has no holes. This longer end (without
holes) goes down.
DETERMINE STAND WIDTH
Your new stand can be assembled to two different widths:
- 22″ for smaller, compact washers
- 24″ for larger washers
Check your washer width to determine the stand width you need. The compact
dryer will assemble to either width. ATTACH WALL MOUNTING BRACKET
Attach one end of the wall mounting bracket to one of the upper rear holes on
one of the stand bases using a Type A screw and a lock nut. Make sure screws
are inserted from the top and the lock nuts are on the bottom. Use the inside
hole on the stand base for 24″ width. Use the outside hole for 22″ width.Attach the other end of the bracket to the upper rear hole of the
other stand base the same way. Use the inside hole on the stand base for 24″
width or the outside hole for
22″ width. Hand-tighten the screws and nuts.
ATTACH DIAGONAL BRACE
Attach the diagonal brace to the back of the front uprights on the stand
bases. The brace must run from the lower left to the upper right when viewed
from the rear of the stand.
Insert a Type B screw from the front of the stand into the lower hole on the
left upright and secure with a lock nut. The lock nut will be on the inside of
the upright.
Insert another Type B screw into the hole on the right upright. The top hole
is used for 22″ width, and the lower hole is used for 24″ width. Hand-tighten
the screws and lock nuts. ATTACH CROSS BRACE
Attach the cross brace to the rear uprights on the stand bases. Insert two
Type B screws from the rear of the stand into the lower holes on the uprights
and secure with lock nuts. The lock nuts will be on the insides of the
uprights.
Insert two Type B screws into the upper holes on the uprights. The top holes
are used for 22″ width, and the lower holes are used for 24″ width. Hand-
tighten the screws
and lock nuts. TIGHTEN LOCK NUTS
Securely tighten all lock nuts using a screwdriver and an adjustable wrench or
nut driver.
DETERMINE LOCATION
Locate the stand in an appropriate level area. This location should be
suitable for the size, function, and protection of the stack stand and
appliances. Use the stack stand only for the purpose for which it was
designed. To prevent restriction of airflow, do not use top of dryer for
storage.
The proper location of all utility connections is shown in the Utilities and
Grounding illustration. These are not all needed in each installation, but
those used should be located according to these dimensions so that utilities
can be reached after installation.
Dryers
Dryer models may require different utilities;
refer to the Installation Instructions included with your new dryer for
details on required utilities.
Refer to the Utilities and Grounding illustration and the Dryer Installation
Instructions for details on final utility connections and grounding
information.
NOTE: All fittings and outlets must be located so that they clear cross
members of stack stand.
Automatic Washers
All automatic washers require a hot and cold water supply, a proper drain and
a 120-volt electrical supply. Refer to the Installation Instructions included
with your new automatic washer for detailed installation requirements.
If the automatic washer is to be operated in a different location (portable)
and only stored in the stack stand, those utilities marked with an asterisk
(*) in the Utilities and Grounding illustration would not be required at this
location. They would be required at the location where the automatic washer is
to be operated, with the exception of the drain pipe, since the machine can be
drained into a sink or laundry tub.
NOTE: If both the automatic washer and dryer require a 120-volt
electrical supply, TWO separate 15-ampere circuits must be used (one for each
appliance). DO NOT, under any circumstances, connect both appliances to the
same circuit as blown fuses will result.
LOCATE MOUNTING HOLES
Push the dryer and stand against the wall in the selected location and locate
two wall studs.
Start 2 Type C screws through holes in the mounting bracket that line up with
studs. DO NOT SCREW IN ALL THE WAY. Multiple holes in the bracket allow for
variation in location of wall studs. Once the holes are started, remove
the screws from the mounting bracket and move the stand away from the wall.
For installations requiring clearance from the wall:
If the stand cannot be pushed all the way against the wall, secure a piece of
wood to the wall studs to line up with the holes on the mounting bracket. The
wood must be the
same thickness as the clearance. Follow the steps above, starting the screws
in the piece of wood. INSTALL DRYER TO STAND
Carefully follow section entitled Preparing Your Dryer for Installation in the
Installation Instructions for your new dryer. The dryer weighs approximately
100 pounds.
WARNING
Potential Personal Injury. More than one person is recommended to lift the
dryer into position because of its weight and size. Failure to do so could
result in personal injury or death.
Use 6 Type D screws to secure the dryer to the stand. Tighten the screws using
an adjustable wrench or nut driver. The dryer will sit approximately 11⁄4 ″
forward of the end of the top angle. NOTE: The outside holes
are used for 22″ width, and the inside holes are used for 24″ width.
MOVE DRYER AND STAND INTO FINAL POSITION AND INSTALL DRYER EXHAUST
Push the dryer and stand against the wall in the selected location.
If the hole for the exhaust has been located as shown in the Utilities and
Grounding illustration, it will align with the dryer exhaust when the stack
stand and dryer are placed in the selected operating position.Follow the Installation Instructions included with your dryer to
make exhaust connections.
SECURE STAND TO WALL
After the exhaust is connected and the dryer and stack stand are in the
selected operating position, secure the stand to the wall using 2 Type C
screws in the holes started earlier. INSTALL WASHER
Follow the Installation Instructions included with your washer to make washer
connections.
After washer connections are made, move the washer into its operating position
between the stand side sections and push it completely toward the rear. Use
care not to kink or pinch the water inlet hose, and be sure the drain hose is
placed in the drain pipe with no kinks or twists. INSTALL LID LATCH
If a washer with a lift lid is to be installed and used under the stand,
install the washer lid latch as shown using a Type D screw in the hole behind
one of the front mounting holes. The lid latch may be installed on either
side.
NOTE: The screw for the lid latch will thread into bottom of the dryer.
Tighten securely using a nut driver.
175D1807P423
49-90159
03-03 JR
Documents / Resources
| GE
APPLIANCES DSDR24F Electric Dryers
Stand
[pdf] Instruction Manual
DSDR24F Electric Dryers Stand, DSDR24F, Electric Dryers Stand, Dryers Stand,
Stand
---|---
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>