SAFETY INSTRUCTIONS

  • There are no replaceable components inside the smoke detector.
  • Only the battery is replaceable.
  • Do not use the product in humid, dusty or smoky environments.
  • When the battery capacity reaches a low level the smoke detector will emit an audio prompt approximately every 45 seconds to indicate that the battery needs to be replaced.
  • Store the smoke detector and packaging materials out of the reach of children.

SYMBOLS

SYMBOLS

|

Read the instructions.

| Approved in accordance with the relevant directives.
|

Recycle discarded product in accordance with local regulations.

TECHNICAL DATA

HOW TO USE?

The smoke detector functions through the dispersal of infrared radiation in the smoke that develops in the initial phase of the fire. It consists of a photoelectric system that processes the signals from the infrared radiation. The infrared radiation spreads out over the surface of the smoke when the smoke comes in the smoke detector. The photoelectric diode receives the dispersed radiation and activates the photoelectric current, which starts the alarm signal.

INSTALLATION

  1. Remove the mounting plate on the back of the smoke detector and insert a 9 V battery.
  2. Press the test button for a few seconds to start the alarm.
  3. Release the button when you hear the alarm it sounds two or three times and then stops automatically.
  4. This shows that the smoke detector is working.
  5. Install the smoke detector in a suitable place with the two supplied screws e.g. one the ceiling.
    1. Screws
    2. Mounting plate

REPLACING THE BATTERY

Grip the smoke detector casing, twist anticlockwise and unhook the detector from the wall/ceiling holder. Remove the old battery and then connect the new battery. Put the new battery in the battery compartment, fit the detector in the wall ceiling holder and lock in place in the holder by twisting clockwise. Test the smoke detector by pressing the test button. The alarm gives a loud audio prompt If there is no load alarm signal the smoke detector is either defective or incorrectly installed.

OBS

The detector will not fit in the wall/ceiling holder if no battery is inserted. Do not take out the battery unless a new battery is to be immediately inserted.