A LED SR-2303P Constant Voltage DALI Dimmer Instruction Manual
- June 9, 2024
- A LED
Table of Contents
A LED SR-2303P Constant Voltage DALI Dimmer
Important : Read All Instructions Prior to Installation
Function introduction
Phase Cut Dim Signal Input
Product Data
Input Voltage| Output Current| Output Power| Remarks| Size(LxWxH)| Dimming Input| DALI
Consumption
| Dimming Range| Ambient Temperature
---|---|---|---|---|---|---|---|---
12-36VDC
| ****
1x20A
| ****
1x(240-720)W
| ****
Constant voltage
| ****
170×53.4x28mm
| DALI&AC Push& 0/1-10V&Phase Cut| ****
2mA
| ****
0.1%-100%
| -20℃ ~ +50℃
- Multifunction 4 in 1 LED Dimmer, with DALI, AC push, 0/1-10V, and Phase Cut dimming interfaces
- In compliance with IEC 62386-101:2014, IEC 62386-102:2014, IEC 62386-207 Ed2.
- Built-in DALI-2 interface, DALI DT6 device
- Match all DALI systems in the market
- Dip switch to select different dimming interfaces
- 1 channel 12-36VDC output, max. 20A
- Supports both leading edge and trailing edge dimming input
- 1 DALI address assigned by the DALI master
- Compatible with universal phase cut dimmers
- To work with a power repeater to expand output power unlimitedly.
- Waterproof grade: IP20
Safety & Warnings
- DO NOT select dimming input with power applied to the device.
- DO NOT install with power applied to the device.
- DO NOT expose the device to moisture.
Operation
DIP Switch to Select Dimming Input
Before wiring, please first select the dimming input interface by DIP switch
depending on the control system used. Different dimming interfaces can not be
wired and used simultaneously. Only 1 of the 4 can be selected and wired at a
time.
DALI Address Assigned by DALI Masters
While selecting DALI dimming input, the DALI address can be assigned by the
DALI Master controller automatically, please refer to user manuals of
compatible DALI Masters for specific operations.
Wiring Diagram (When connecting with two separate loads and each one is not
over 10A)
Note: the device allows 0.5-2.5mm2 wire specifications, please make sure
the rated current of the used wire is enough for the loads.![decorative.Title
A-LED SR-2303P-Constant-Voltage-DALI-Dimmer-Instruction-Manual-fig-2
Caption
Description
File URL:
https://manuals.plus/wp-content/uploads/2023/01/A-LED-SR-2303P-Constant- Voltage-DALI-Dimmer-Instruction-Manual-fig-2.png
Copy URL to clipboard
ATTACHMENT DISPLAY SETTINGS
Alignment
Center
Link To
None
Size
Full Size – 718 × 443
Selected media actions
8 items selected
Edit SelectionClear Insert into post](https://manuals.plus/wp- content/uploads/2023/01/A-LED-SR-2303P-Constant-Voltage-DALI-Dimmer- Instruction-Manual-fig-2.png)
Note: The Push Dim input voltage range is 100-240VAC. 3. With 0/1-10V
Note: the Phase-Cut Dim input voltage range is 100-240VAC.
Wiring Diagram (When connecting with a single load that is over 10A)
Note: the device allows 0.5-2.5mm2 wire specifications, please make sure
the rated current of the used wire is enough for the
loads.
Note : The Push Dim input voltage range is 100-240VAC.
Note: the Phase-Cut Dim input voltage range is 100-240VAC.
Product Dimension