HAYWARD SERIES CL100/110 Automatic Chlorine Feeders Owner’s Manual
- June 9, 2024
- Hayward
Table of Contents
- IMPORTANT SAFETY INSTRUCTIONS
- INSTALLATION:
- DIRECTIONS FOR USE:
- MAINTENANCE:
- SPARE PARTS
- PRODUCT REGISTRATION
- Section 1. Safety Information
- Section 2. Product Description and Model numbers
- Section 3. Installing Jandy
- Section 4. Replacing Jandy Pro Series Light Fixture in an Existing Pool
- Section 5. Wiring Options for Controlling Jandy Pro series WaterColors
- Section 6. Jandy Pro series WaterColors lED light Operating instructions
- Section 7. Replacing light Engine (PCB)
- Section 8. Twelve (12) Volt installation
- Section 9. Exploded View and Replacement Parts
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
SERIES CL100/110 Automatic Chlorine Feeders
Owner’s Manual Owner’s Manual
SERIES CL100/110
SERIES CL200/220
HAYWARD by
AUTOMATIC CHLORINE FEEDERS
IMPORTANT SAFETY INSTRUCTIONS
Basic safety precautions should always be followed, including the following:
Failure to follow instructions can cause severe injury and/or death.
This is the safety-alert symbol. When you see this symbol on your equipment or
in this manual, look for one of the following signal words and be alert to the
potential for personal injury.
WARNING warns about hazards that could cause serious personal injury,
death or major property damage and if ignored presents a potential hazard.
CAUTION warns about hazards that will or can cause minor or moderate
personal injury and/or property damage and if ignored presents a potential
hazard. It can also make consumers aware of actions that are unpredictable and
unsafe.
DANGER indicates an imminently hazardous situation which, if not avoided,
will result in death, serious injury, or major property damage.
The NOTICE label indicates special instructions that are important but not
related to hazards.
Hayward Pool Products
620 Division Street, Elizabeth, NJ 07207
Phone: (908) 351.5400
www.haywardpool.com
WARNING – Read and follow all instructions in this owner’s manual and on
the equipment.
Failure to follow instructions can cause severe injury and/or death.
WARNING – Suction Entrapment Hazard.
Suction in suction outlets and/or suction outlet covers which are, damaged,
broken, cracked, missing, or unsecured can cause severe injury and/or death
due to the following entrapment hazards:
Hair Entrapment- Hair can become entangled in suction outlet cover.
Limb Entrapment- A limb inserted into an opening of a suction outlet sump
or suction outlet cover that is damaged, broken, cracked, missing, or not
securely attached can result in a mechanical bind or swelling of the limb.
Body Suction Entrapment – A negative pressure applied to a large portion
of the body or limbs can result in an entrapment.
Evisceration/ Disembowelment – A negative pressure applied directly to
the intestines through an unprotected suction outlet sump or suction outlet
cover which is, damaged, broken, cracked, missing, or unsecured can result in
evisceration/disembowelment.
Mechanical Entrapment- There is potential for jewelry, swimsuit, hair
decorations, finger, toe or knuckle to be caught in an opening of a suction
outlet cover resulting in mechanical entrapment.
WARNING – To Reduce the risk of Entrapment Hazards:
o When outlets are small enough to be blocked by a person, a minimum of two
functioning suction outlets per pump must be installed. Suction outlets in the
same plane (i.e. floor or wall), must be installed a minimum of three feet
(3’) [1 meter] apart, as measured from near point to near point.
o Dual suction fittings shall be placed in such locations and distances to
avoid “dual blockage” by a user.
o Dual suction fittings shall not be located on seating areas or on the
backrest for such seating areas.
o The maximum system flow rate shall not exceed the flow rating of as listed
on Table 1.
o Never use Pool or Spa if any suction outlet component is damaged, broken,
cracked, missing, or not securely attached.
o Replace damaged, broken, cracked, missing, or not securely attached suction
outlet components immediately.
o In addition two or more suction outlets per pump installed in accordance
with latest ASME, APSP Standards and CPSC guidelines, follow all National,
State, and Local codes applicable.
o Installation of a vacuum release or vent system, which relieves entrapping
suction, is recommended.
WARNING – Failure to remove pressure test plugs and/or plugs used in
winterization of the pool/spa from the suction outlets can result in an
increase potential for suction entrapment as described above.
WARNING – Failure to keep suction outlet components clear of debris, such
as leaves, dirt, hair, paper and other material can result in an increase
potential for suction entrapment as described above.
WARNING – Suction outlet components have a finite life, the cover/grate
should be inspected frequently and replaced at least every ten years or if
found to be damaged, broken, cracked, missing, or not securely attached.
CAUTION – Components such as the filtration system, pumps and heater must
be positioned so as to prevent their being used as means of access to the pool
by young children.
WARNING – Never operate or test the circulation system at more than 50
PSI.
WARNING – Never change the filter control valve position while the pump
is running.
WARNING – To reduce risk of injury, do not permit children to use or
climb on this product. Closely supervise children at all times. Components
such as the filtration system, pumps, and heaters must be positioned to
prevent children from using them as a means of access to the pool.
WARNING – Hazardous Pressure. Pool and spa water circulation systems
operate under hazardous pressure during start up, normal operation, and after
pump shut off. Stand clear of circulation system equipment during pump start
up. Failure to follow safety and operation instructions could result in
violent separation of the pump housing and cover, and/or filter housing and
clamp due to pressure in the system, which could cause property damage, severe
personal injury, or death. Before servicing pool and spa water circulation
system, all system and pump controls must be in off position and filter manual
air relief valve must be in open position. Before starting system pump, all
system valves must be set in a position to allow system water to return back
to the pool. Do not change filter control valve position while system pump is
running. Before starting system pump, fully open filter manual air relief
valve. Do not close filter manual air relief valve until a steady stream of
water (not air or air and water)
is discharged.
WARNING – Separation Hazard. Failure to follow safety and operation
instructions could result in violent separation of pump and/or filter
components. Strainer cover must be properly secured to pump housing with
strainer cover lock ring. Before servicing pool and spa circulation system,
filters manual air relief valve must be in open position. Do not operate pool
and spa circulation system if a system component is not assembled properly,
damaged, or missing. Do not operate pool and spa circulation system unless
filter manual air relief valve body is in locked position in filter upper
body.
WARNING – Risk of Electric Shock. All electrical wiring MUST be in
conformance with applicable local codes, regulations, and the National
Electric Code (NEC). Hazardous voltage can shock, burn, and cause death or
serious property damage. To reduce the risk of electric shock, do NOT use an
extension cord to connect unit to electric supply. Provide a properly located
electrical receptacle. Before working on any electrical equipment, turn off
power supply to the equipment.
WARNING – To reduce the risk of electric shock replace damaged wiring
immediately. Locate conduit to prevent abuse from lawn mowers, hedge trimmers
and other equipment.
WARNING – Electrical ground all electrical equipment before connecting to
electrical power supply. Failure to ground all electrical equipment can cause
serious or fatal electrical shock hazard.
WARNING – Do NOT ground to a gas supply line.
WARNING – To avoid dangerous or fatal electrical shock, turn OFF power to
all electrical equipment before working on electrical connections.
WARNING – Failure to bond all electrical equipment to pool structure will
increase risk for electrocution and could result in injury or death. To reduce
the risk of electric shock, see installation instructions and consult a
professional electrician on how to bond all electrical equipment. Also,
contact a licensed electrician for information on local electrical codes for
bonding requirements.
Notes to electrician: Use a solid copper conductor, size 8 or larger. Run a
continuous wire from external bonding lug to reinforcing rod or mesh. Connect
a No. 8 AWG (8.4 mm2 ) [No. 6 AWG (13.3 mm 2) for Canada] solid copper bonding
wire to the pressure wire connector provided on the electrical equipment and
to all metal parts of wimming pool, spa, or hot tub, and metal piping (except
gas piping), and conduit within 5 ft. (1.5 m) of inside walls of swimming
pool, spa, or hot tub.
IMPORTANT – Reference NEC codes for all wiring standards including, but
not limited to, grounding, bonding and other general wiring procedures.
WARNING – Risk of Electric Shock. Connect only to a branch circuit
protected by a ground-fault circuit-interrupter (GFCI).
Contact a qualified electrician if you cannot verify that the circuit is
protected by a GFCI.
WARNING – Risk of Electric Shock . The electrical equipment must be
connected only to a supply circuit that is protected by a ground-fault
circuit-interrupter (GFCI). Such a GFCI should be provided by the installer
and should be tested on a routine basis. To test the GFCI, push the test
button. The GFCI should interrupt power. Push reset button. Power should be
restored. If the GFCI fails to operate in this manner, the GFCI is defective.
If the GFCI interrupts power to the electrical equipment without the test
button being pushed, a ground current is flowing, indicating the possibility
of an electrical shock. Do not use this electrical equipment. Disconnect the
electrical equipment and have the problem corrected by a qualified service
representative before using.
CAUTION – The pump is intended for use with permanently-installed pools
and may be used with hot tubs and spas if so marked. Do not use with storable
pools. A permanently-installed pool is constructed in or on the ground or in a
building such that it cannot be readily disassembled for storage. A storable
pool is constructed so that it is capable of being readily disassembled for
storage and reassembled to its original integrity.
SAVE THESE INSTRUCTIONS
HAYWARD® Pool Products Limited Warranty
To original purchasers of this equipment, Hayward Pool Products, Inc.
warrants its chemical feeders to be free from defects in materials and
workmanship for a period of ONE (1) year from the date of purchase, when used
in single family residential applications.
The limited warranty excludes damage from freezing, negligence, improper
installation, improper use or care or any Acts of God. Parts that fail or
become defective during the warranty period shall be repaired or replaced, at
our option, within 90 days of the receipt of defective product, barring
unforeseen delays, without charge.
Proof of purchase is required for warranty service. In the event proof of
purchase is not available, the manufacturing date of the product will be the
sole determination of the purchase date.
To obtain warranty service, please contact the place of purchase or the
nearest Hayward Authorized Service Center. For assistance on your nearest
Hayward Authorized Service Center please visit us at
www.haywardpool.com.
Hayward shall not be responsible for cartage, removal, repair or installation
labor or any other such costs incurred in obtaining warranty replacements or
repair.
The Hayward Pool products warranty does not apply to components manufactured
by others. For such products, the warranty established by the respective
manufacturer will apply.
The express limited warranty above constitutes the entire warranty of Hayward
Pool Products with respect to its’ pool products and is in lieu of all other
warranties expressed or implied, including warranties of merchantability or
fitness for a particular purpose. In no event shall Hayward Pool products be
responsible for any consequential, special or incidental damages of any
nature.
Some states do not allow a limitation on how long an implied warranty lasts,
or the exclusion of incidental or consequential damages, so the above
limitation may not apply to you. This warranty gives you specific legal
rights, and you may also have other rights, which vary from state to state.
*Supersedes all previous publications.
Hayward Pool Products
Elizabeth, NJ 07207
620 Division Street
DANGER Mixing Chemicals or using fast dissolving chemicals may result in
explosion and/or fire. To avoid death, serious injury or major property
damage:
Use only slow dissolving Trichlor Chlorine tablets.
Never use fast dissolving Trichlor Chlorine tablets.
Never mix chemicals.
Never mix Trichlor Chlorine tablets with Calcium Hypochlorite, or with
any other form of concentrated chlorine or other chemicals. Fire and/or
explosion may result.
Never add any other types of chlorine, pH adjusters, shock treatments or
algaecides through the skimmer. If these products must be used, they should be
added directly into the pool water.
Never isolate chlorine feeder with valves or other devices.
WARNING Wear eye and skin protection while maintaining or servicing this
unit.
WARNING Do not inhale fumes from the chlorinator or chemical container.
WARNING Chlorine feeder may be under pressure. Use caution removing
cover.
INSTALLATION:
CL–100/200
-
Your CL–100/200 automatic chlorine feeder is designed for permanent installation in the pool water return line.
-
Always install the chlorine feeder after the heater. If there is no heater, install after the filter.
CAUTION Damage to the heater or filter may result if concentrated chlorine is allowed to flow through them. An in-line positive seal corrosion resistant check valve should be installed to reduce backflow of chlorine gas when the system is shut off. If the chlorine feeder is located below water level, you may want to install a check valve to prevent water backflow when operating/servicing the unit. The CL100 has this feature built in. -
Both the CL–100/200 are furnished with 1 1/2” female threads. If PVC socket (solvent weld) connections are desired, order SP1500UNPAK2, socket flush union end connectors package. For threaded male and union connectors, order SP1500UNMPAK1 male union connector package (two required). Thread or socket adapters may also be used. Only use pipe sealants formulated and approved for use with ABS plastic connections (e.g. Teflon Tape, Permatex Form-A-Gasket No. 2, Laco Plasto-Joint stick). Do not over tighten pipe fitting. Proper fitting makeup is hand tight plus 1 to 1 1 /2 turns maximum.
NOTICE: After starting up system, re-check all connections for leaks. Re-
tighten as required.
CAUTION Never install chlorine feeder directly into copper plumbing as
pipe damage may occur. If you have brass or bronze backwash valves, or other
sensitive metallic components, consult your dealer for precautions or
recommendations for your particular system.
CL–110/220
-
The inlet connection should be made in the piping after the pump and before the filter. Mark location on pipe.
-
The outlet connection should be made in the piping after the heater. If no heater is being used, connection should be made after the filter. Mark location on pipe.
-
Based on the locations from steps. No. 1 and No. 2, cut tubing to required lengths. Be sure ends are cut evenly and cleanly.
-
Wrap Teflon tape on larger male thread of Check Valve and thread it hand tight plus ½ turn into outlet port of chlorinator. DO NOT OVER TIGHTEN.
NOTICE: The Check Valve is marked with a “dot”. It also has a ball that “clicks” when you shake it. -
Wrap Teflon tape on larger male thread of the Inlet Fitting Adapter and thread it hand tight plus ½ turn into the inlet port of chlorinator. DO NOT OVER TIGHTEN.
-
To connect inlet tubing to chlorinator, place Compression Nut over inlet tubing and slide nut up about 2”.
Insert the tubing all the way into the Inlet Fitting Adapter socket and, holding tubing in place, tighten nut firmly by hand. Do not over tighten. -
Connect outlet tubing to the Check Valve in the same manner as in step 6 above.
NOTICE: The saddle fittings and clamps are designed to fit the O.D. of 1 1/2” or 2” pipe. -
Drill a 3/8” hole at location identified in Step 1 of Planning Installation section. Clean all burrs, shavings etc.
Fit Saddle Fitting, with gasket, into oval shaped hole in clamp and insert fitting into the 3/8” hole. Secure clamp around Saddle Fitting, gasket and pipe and tighten securely to achieve a good seal. Do not over tighten clamp. -
Drill a 3/8” hole at location identified in Step 2 of Installation section for CL-110/220. Install Saddle Fitting as in Step 8 above.
-
Connect inlet and outlet tubing to the Saddle Fittings with Compression Nuts as in Step 6 above. Do not over tighten.
CAUTION Never install chlorine feeder directly into copper plumbing as
pipe damage may occur. If you have brass or bronze backwash valves, or other
sensitive metallic components, consult your dealer for precautions or
recommendations for your particular system.
NOTICE: After starting up system, re-check all connections for leaks. Re-
tighten as required.
DIRECTIONS FOR USE:
GENERAL
Before using your chlorinator, your pool/spa water should be properly balanced
and conditioned and should have a chlorine residual of approximately 1.0 to
1.5 ppm. Follow dealer and chemical manufacturer’s directions and
instructions.
Check chlorine residual daily and adjust the dial valve for more or less
chlorine. The chlorine demand for pools and spas varies based on usage,
temperature, sunlight, etc. Initially, you’ll have to experiment to determine
the proper amount of chlorine and the correct valve setting required for your
pool and filter time cycle. Follow chemical manufacturer’s instructions for
proper chlorine level.
DANGER Mixing Chemicals or using fast dissolving chemicals may result in
explosion and/or fire.
** To avoid death, serious injury or major property damage:
Use only slow dissolving Trichlor Chlorine tablets.
Never use fast dissolving Trichlor Chlorine tablets.
Never mix chemicals.
Never mix Trichlor Chlorine tablets with Calcium Hypochlorite, or with any
other form of concentrated chlorine or other chemicals. Fire and/or explosion
may result.
Never add any other types of chlorine, pH adjusters, shock treatments or
algaecides through the skimmer. If these products must be used, they should be
added directly into the pool water.
Never isolate chlorine feeder with valves or other devices.
WARNING Wear eye and skin protection while maintaining or servicing this
unit.
WARNING Do not inhale fumes from the chlorinator or chemical container.
WARNING Chlorine feeder may be under pressure. Use caution removing
cover.
REFILLING CHORINATOR**
- Shut off all pumps and pump timers.
- Turn chlorine feeder flow control valve to “OFF”.
- Verify chlorine feeder return line to pool is unrestricted.
- Wait one minute to relieve system pressure before attempting to remove cover.
- If installed in a flooded system, shut off valves to isolate chlorinator.
- Remove cover.
- Refill chlorine feeder with slow dissolving Trichlor-Chlorine Tablets.
- Secure cover to chlorine feeder.
- If installed in a flooded system, open valves to assure flow from pump to pool.
- Turn flow control valve on chlorinator to desired setting and restart pump.
MAINTENANCE:
TO CHANGE O-RING CL100/110
- Read and follow instructions in Steps 1 to 5 in Refilling Chlorinator section.
- Remove the O-Ring and replace with a Genuine Hayward Part O-Ring (part no. CLX110K).
- Replace cover. If chlorinator needs to be refilled, read and follow instructions in Steps 6 to 8 in Refilling chlorinator section.
TO CHANGE O-RING CL200/220
- Read and follow instructions in Steps 1 to 5 in Refilling Chlorinator section.
- Pry off Logo Cap, located on the cover of the chlorinator. Unscrew and remove retainer screw. Cover may now be slipped free of the Cover Cap.
- Replace O-ring with a Genuine Hayward Part O-ring (part no. CLX200K). Reassemble being sure Slip Washers are in place on stem of Cover (inside), and under head of Retaining Screw.
- Replace cover. If chlorinator needs to be refilled, read and follow instructions in Steps 6 to 8 in Refilling Chlorinator section.
TO REMOVE FLOW CONTROL VALVE HANDLE
Set pointer to FULL. Insert screwdriver in slot opposite pointer, lift up and
rotate handle counterclockwise. This allows the handle index lock tab to clear
the body ridge.
TO INSTALL FLOW CONTROL VALVE HANDLE
- The flow control valve handle Genuine Hayward Part (CLX200PA) is furnished in two pieces.
- To install push the handle into the stem and fully install stem into body. You may have to remove handle and reposition to assure the stem is fully seated.
- Remove handle by pulling straight out.
- Apply a single drop of Super Glue to the end of the stem, push on handle, positioned in the OFF position. Apply pressure for 30 seconds.
WINTERIZING
Where freezing temperatures can be expected, drainall water and remove all
chlorine from chlorinator. ( For in-line permanently installed unit remove
drain plug). Carefully remove all tablets and pieces of tablets. Rinse out
chlorinator thoroughly with water. Replace cover and drain plug.
VACUUMING
When vacuuming, close flow control valve to prevent bypass of sediment and
possible clogging of control valve.
LUBRICATION
Never use petroleum type lubricants on Cover O-Ring. To lubricate use Genuine
Hayward Part Jack’s Lube No. 327 (Part No. SP032712).
SPARE PARTS
CL100
Ref No.
| Part Number| Description|
No. Req’d
---|---|---|---
1| CLX110C| Cover| 1
2| CLX110K| O-Ring| 1
3| CLX110FA| Control Knob Assembly| 1
4| CLX220CV| Check Valve Assembly| 1
5| SPX1700FGV| Drain Plug w/Gasket| 1
| SP032712| Hayward Jack’s Lub #327| 1
CL200
Ref No.
| Part Number| Description|
No. Req’d
---|---|---|---
1| CLX200E| Logo Cap| 1
2| CLX200G| Cover Retaining Screw| 1
3| CLX200W| Slip Washer| 2
4| CLX200C| Cover Cap| 1
5| CLX200B| Cover| 1
6| CLX200K| O-Ring| 1
7| CLX200H| Feeder Tube (some models)| 1
8| CLX200PA| Control Valve Assembly| 1
9| SPX1700FA| Drain Plug w/Gasket| 1
10| SPX1500UNPAK| Union Connectors–Socket (2)| –
11| CLX200BS| Base| 1
| SP032712| Hayward Jack’s Lub #327| 1
CL110
Ref No.
| Part Number| Description|
No. Req’d
---|---|---|---
1| CLX100C| Cover| 1
2| CLX110K| O–Ring| 1
3| CLX110DA| Dial Flow Valve| 2
4| CLX110B| Base| 1
5| CLX220CV| Check Valve Assembly| 1
6| CLX220H| Compression Nuts| 4
7| CLX220G| Saddle Fitting| 2
8| CLX220K| Saddle Clamp| 2
9| CLX220J| Plastic Tubing–8 Ft.| 1
| SP032712| Hayward Jack’s Lub #327| 1
CL220
Ref No.
| Part Number| Description|
No. Req’d
---|---|---|---
1| CLX200E| Logo Cap| 1
2| CLX200G| Cover Retaining Screw| 1
3| CLX200W| Slip Washer| 2
4| CLX200C2| Cover Cap| 1
5| CLX200B| Cover| 1
6| CLX200K| O-Ring| 1
7| CLX200H| Feeder Tube (some models)| 1
8| CLX200PA| Control Valve Assembly| 1
9| CLX220B| Base| 1
10| CLX220CV| Check Valve Assembly| 1
11| CLX220D| Inlet Fitting Adapter| 1
12| CLX220H| Compression Nuts| 4
13| CLX220G| Saddle Fitting| 2
14| CLX220K| Saddle Clamp| 2
15| CLX220J| Plastic Tubing—8 ft.| 1
| SP032712| Hayward Jack’s Lub #327| 1
PRODUCT REGISTRATION
(Retain For Your Records)
DATE OF INSTALLATION ____
▲Retain this Warranty Certificate (upper portion) in a safe and convenient
location for your records.
DETACH HERE: Fill out bottom portion completely and mail within 10 days of
purchase/installation or register online.
AUTOMATIC CHLORINE FEEDERS
Register online at www.haywardpool.com
Please Print Clearly:
First Name____
Last Name
Street Address
City___
State_
Zip____
Phone Number____
Purchase Date
E-Mail Address____
Serial Number…………………………………………………
Model Number___
Pool Capacity_(U.S. Gallons)
Please include me on all e-mail communications regarding Hayward ® Equipment
or promotions.
Mail to: Hayward Pool Products, 620 Division Street, Elizabeth, NJ 07207
Attn: Warranty Dept
Or REGISTER YOUR WARRANTY ON-LINE AT
WWW.HAYWARDPOOL.COM
Warranty Card Registration Hayward is a registered
trademark of Hayward Industries, Inc.
© Hayward Pool Products. 2011 All rights reserved Jandy Pro series
WaterColors lED lights
Underwater large and small light
WARning
FOR YOUR sAFETY – This product must be installed and serviced by a contractor
who is licensed and qualified in pool equipment by the jurisdiction in which
the product will be installed where such state or local requirements exist.
The maintainer must be a professional with sufficient experience in pool
equipment installation and maintenance so that all of the instructions in this
manual can be followed exactly. Before installing this product, read and
follow all warning notices and instructions that accompany this product.
Failure to follow warning notices and instructions may result in property
damage, personal injury, or death. improper installation and/or operation will
void the warranty.
improper installation and/or operation can create unwanted electrical hazard
which can cause serious injury, property damage, or death.
ATTEnTiOn insTAllER – This manual contains important information about
the installation, operation and safe use of this product. This information
should be given to the owner/ operator of this equipment.
Section 1. Safety Information
IMPORTAnT sAFETY insTRUCTiOns PERTAining TO A RisK OF FiRE, ElECTRiC shOCK,
OR inJURY TO PERsOns READ AnD FOllOW All insTRUCTiOns
When installing and using this electrical equipment, basic safety precautions
should always be followed, including the following:
WARNING
RisK OF ElECTRiCAl shOCK OR ElECTROCUTiOn. This underwater light must be
installed by a licensed or certified electrician in accordance with the
National Electrical Code and applicable local codes and ordinances. Improper
installation will create an electrical hazard, which could result in death or
serious injury to pool or spa users, installers, or others due to electrical
shock, and may also cause damage to property. Read and follow the specific
instructions below.
WARNING
Before installing this underwater light, read and follow all warning notices
and instructions accompanying this light. Failure to follow safety warnings
and instructions can result in severe injury, death, or property damage. Call
707-776-8200 for additional free copies
of these instructions.
CAUTION
Except when the Jandy Pro Series WaterColors LED Lights are installed in an
area of the swimming pool that is not used for swimming and the lens is
adequately guarded to keep any person from contacting it, the light shall be
installed in or on a wall of the pool, with the top of the lens opening not
less than 18 inches (457 mm) below the normal water level of the pool
ATTENTION INSTALLER
This manual contains important information about the installation, operation
and safe use of this product. This information should be given to the
owner/operator of this equipment.
NOTICE
The Jandy Pro Series WaterColors LED Lights are intended for installation in
fresh water and salt water swimming pools. It is important to ensure that the
wet niches in which the lights are installed are intended for their
appropriate application, either fresh water or salt water pools.
Section 2. Product Description and Model numbers
Model #| WaterColors Light Size| Voltage| Amps|
Cord Length| Face Ring Material
---|---|---|---|---|---
CPLVLEDS30| Large| 12 Volt AC| 4.0| 30 feet| Stainless Steel
CPLVLEDS50| Large| 12 Volt AC| 4.0| 50 feet| Stainless Steel
CPLVLEDS100| Large| 12 Volt AC| 4.0| 100 feet| Stainless Steel
CPLVLEDP100| Large| 12 Volt AC| 4.0| 100 feet| Plastic
CPLVLEDS50C| Large| 12 Volt AC| 4.0| 50 feet| Stainless Steel
CPLVLEDS100C| Large| 12 Volt AC| 4.0| 100 feet| Stainless Steel
CPLVLEDP100C| Large| 12 Volt AC| 4.0| 100 feet| Plastic
CPHVLEDS30| Large| 120 Volt AC| 0.4| 30 feet| Stainless Steel
CPHVLEDS50| Large| 120 Volt AC| 0.4| 50 feet| Stainless Steel
CPHVLEDS100| Large| 120 Volt AC| 0.4| 100 feet| Stainless Steel
CPHVLEDP100| Large| 120 Volt AC| 0.4| 100 feet| Plastic
CPHVLEDS150| Large| 120 Volt AC| 0.4| 150 feet| Stainless Steel
CPHVLEDS250| Large| 120 Volt AC| 0.4| 250 feet| Stainless Steel
CPHVLEDS50C| Large| 120 Volt AC| 0.4| 50 feet| Stainless Steel
CPHVLEDS100C| Large| 120 Volt AC| 0.4| 100 feet| Stainless Steel
CPHVLEDP100C| Large| 120 Volt AC| 0.4| 100 feet| Plastic
| | | | |
CSLVLEDS30| Small| 12 Volt AC| 2.0| 30 feet| Stainless Steel
CSLVLEDS50| Small| 12 Volt AC| 2.0| 50 feet| Stainless Steel
CSLVLEDS100| Small| 12 Volt AC| 2.0| 100 feet| Stainless Steel
CSLVLEDP100| Small| 12 Volt AC| 2.0| 100 feet| Plastic
CSLVLEDS50C| Small| 12 Volt AC| 2.0| 50 feet| Stainless Steel
CSLVLEDS100C| Small| 12 Volt AC| 2.0| 100 feet| Stainless Steel
CSLVLEDP100C| Small| 12 Volt AC| 2.0| 100 feet| Plastic
CSHVLEDS30| Small| 120 Volt AC| 0.2| 30 feet| Stainless Steel
CSHVLEDS50| Small| 120 Volt AC| 0.2| 50 feet| Stainless Steel
CSHVLEDS100| Small| 120 Volt AC| 0.2| 100 feet| Stainless Steel
CSHVLEDP100| Small| 120 Volt AC| 0.2| 100 feet| Plastic
CSHVLEDS150| Small| 120 Volt AC| 0.2| 150 feet| Stainless Steel
CSHVLEDS250| Small| 120 Volt AC| 0.2| 250 feet| Stainless Steel
CSHVLEDS50C| Small| 120 Volt AC| 0.2| 50 feet| Stainless Steel
CSHVLEDS100C| Small| 120 Volt AC| 0.2| 100 feet| Stainless Steel
CSHVLEDP100C| Small| 120 Volt AC| 0.2| 100 feet| Plastic
Section 3. Installing Jandy
Pro Series Light Fixture during New Construction
WARNING
Risk of Electrical Shock or Electrocution. This underwater light must
be installed by a licensed or certified electrician or a qualified pool
serviceman in accordance with the National Electrical Code and all applicable
local codes and ordinances. Improper installation will create an electrical
hazard, which could result in death or serious injury to pool or spa users,
installers or others due to electrical shock, and may also cause damage to
property.
Always disconnect the power to the color light at the circuit breaker before
installing or servicing the light. Failure to do so could result in death or
serious injury to serviceman, pool or spa users or others due to electrical
shock.
3.1 Preparing the Light Fixture for Installation
NOTE The electrician must complete preparatory steps before light
fixture is installed. See Figure 1.
Ensure that the pool meets the requirements of the current National Electrical
Code and all local codes and ordinances. A licensed or certified electrician
must install the electrical system to meet or exceed those requirements before
the underwater light is installed. Some of the requirements of the National
Electrical Code, which the pool electrical systems must meet, are as follows:
- The lighting circuit must have a Ground Fault Circuit Interrupter (GFCI) for 120 volt models, and must have an appropriately rated circuit
- The junction box (or, for 12 volt models, the low voltage transformer) must be located at least eight (8) inches above water level, at least four (4) inches above ground level, and at least four (4) feet from the edge of the pool. See Figure 1
- The light fixture and all metal items within five (5) feet of the pool must be properly electrically bonded to a reliable point of grounding.
- The wet niche must be properly installed so that the top edge of the underwater light’s lens is at least 18 inches below the surface of the water in the pool. See Figure
- The wet niche must be properly electrically bonded and grounded via the No. 8 AWG ground connector located at the rear of the niche. See Figure1.
NOTE To be certain that the pool’s electrical system meets all applicable
requirements, the electrician should also consult the local building
department.
Use only approved wet niches (see following note) to ensure a safe and proper
installation.
NOTE Jandy Pro Series lights are ETL listed (ETL report/file 3141154CHI)
for installation with only the following manufacturer’s wet niche fixtures:
Large Niche Model Numbers:
Jandy Pro Series: PLNICLRG, PLNICVFLRG, SSNICLRG1R, SSNICLRG1S
Pentair: 620004, 78210200 thru 700, 78210401, 79206700
Hayward DuraNiche: SP0600U
Sta-Rite: 05161-2352 thru 2369, 05163-2395 thru 2396
Small Niche Model Numbers:
Jandy Pro Series: PLNICSM, SSNICSM, Pentair: 78241100, 78242200, 78242300
78243100 thru 300, 78244100 thru 300, 79206600
Hayward DuraNiche: SP0601U
Sta-Rite: 05166-1017 thru 1034, 05167-1035 thru 1037
Pentair® and Sta-Rite® are registered trademarks of Pentair, Inc. Hayward® is
a registered trademark and DuraNiche™ is a trademark of Hayward Pool Products,
Inc. Figure 1. Jandy Pro Series Digital
Color Light Installation
3.1 Installing the Light Fixture
NOTE Perform these steps only after the electrical system
requirements are met.
-
Feed cord through conduit to junction box, leaving at least four (4) feet of cord at the light fixture to coil into the base of the light niche, see Figure The four (4) feet of cord allows the light to be serviced after the pool is filled with water.
-
Cut the cord at the junction box, leaving at least six (6) inches of cord to make connections
-
Strip six (6) inches of the outer cord jacket to expose the three insulated B e careful not to damage the insulation on the three (3) inner wires.
-
Install strain relief over cord jacket and connect all three (3) wires to the corresponding circuit wires in the junction Install the junction box cover.
-
Coil the 4-foot length of cord around the fixture or into the base of the pool niche, and place the light assembly into the light assembly into the niche.
-
Engage the retainer tab on the bottom of the face ring, then pivot the top of the fixture inward and tighten the special pilot screw.
WARNING
Use only the special pilot screw provided with this underwater light. This screw mounts and electrically grounds the housing securely to the mounting ring and wet niche. Failure to use the screw provided could create an electrical hazard, which could result in death or serious injury to pool or spa users, installers or others due to electrical shock. -
Fill the pool until the underwater light is completely submerged in water before operating the light for more than 10 seconds. Turn on main switch or circuit breaker, and the switch,which operates the underwater light, to check for proper operation. Refer to Section 6, Operating Instructions
WARNING
Never operate this underwater light for more than 10 seconds unless it is totally submerged in water.
Without total submersion, the light assembly will get extremely hot, which may result in serious burns or in breakage of the bulb or lens. This may result in serious injury to pool or spa users, installers, or bystanders or damage to property.
Section 4. Replacing Jandy Pro Series Light Fixture in an Existing Pool
or Spa
WARNING
Risk of Electrical Shock or Electrocution. This underwater light must
be installed by a licensed or certified electrician or a qualified pool
serviceman in accordance with the National Electrical Code and all applicable
local codes and ordinances. Improper installation will create an electrical
hazard, which could result in death or serious injury to pool or spa users,
installers or others due to electrical shock, and may also cause damage to
property.
Always disconnect the power to the color light at the circuit breaker before
installing or servicing the light. Failure to do so could result in death or
serious injury to serviceman, pool or spa users or others due to electrical
shock.
4.1Preparing the Light Fixture for Replacement
Verify that the pool meets the requirements of the current National
Electrical Code® (NEC) and all local codes and ordinances. A licensed or
certified electrician must install the electrical system to meet or exceed
those requirements before the underwater light is installed. Some of the
requirements of the National Electrical Code, which the pool’s electrical
system must meet, are as follows:
- The lighting circuit must have a Ground Fault Circuit Interrupter (GFCI) for 120 volt models, and must have an appropriately rated circuit breaker.
- The junction box (or, for 12 volt models, the low voltage transformer) must be located at least eight (8) inches above water level, at least four (4) inches above ground level or pool deck level, and at least 48 inches from the edge of the pool or spa. See Figure 1.
- The light fixture and all metal items within five (5) feet of the pool must be properly electrically bonded to a reliable point of grounding.
- The wet niche must be properly installed so that the top edge of the underwater light’s lens is at least 18 inches below the surface of the water in the See Figure 1.
- The wet niche must be properly electrically bonded and grounded via the No. 8 AWG ground connector located at the rear of the niche. See Figure 1.
To be certain that the pool’s electrical system meets all applicable
requirements, the electrician should also consult the local building
department.
4.2 Replacing the Light Fixture
NOTE Perform these steps only after the electrical system requirements
are met.
WARNING
Failure to bring the pool’s electrical system up to code requirements
before installing the underwater light will create an electrical hazard which
could result in death or serious injury to pool or spa users, installers, or
others due to electrical shock, and may also cause damage to property.
NOTE The light fixture may be replaced without removing water from the
pool.
-
Turn off the main electrical switch or circuit breaker, as well as the switch, which operates the underwater light
-
Unscrew the special pilot screw at top of the face ring and remove the light assembly from the niche, and place the assembly on the deck.
WARNING
Be sure to keep the special pilot screw provided with this underwater light. This screw mounts and electrically grounds the housing securely to the mounting ring and wet niche. Failure to use the screw provided could create an electrical hazard, which could result in death or serious injury to pool or spa users, installers or others due to electrical shock. -
Remove Junction Box cover, disconnect the light fixture wires and strain relief, and then pull the cord out of the conduit from the niche.
-
Feed the new light fixture cord through the conduit from the niche to the Junction Box.
NOTE Depending on the length of the conduit, special tools may be required to pull the cord through the conduit. -
Leave at least four (4) feet of cord to coil around the light fixture or coiled into the base of the light niche, see Figure 1. This allows the light to be serviced after the pool is filled with water.
-
Strip six (6) inches of the outer cord jacket from the cord to expose the three insulated wires. Be careful not to damage the insulation on the three (3) inner wires
-
Cut the cord at the Junction Box, leaving at least six (6) inches of cord to make.
-
Install the strain relief over the cord jacket and connect all three wires to the corresponding circuit wires in the junction box. Install the junction box cover.
-
Reinstall the light assembly into the niche and tighten the special pilot screw.
WARNING
Use only the special pilot screw provided with this underwater light. This screw mounts and electrically grounds the housing securely to the mounting ring and wet niche. Failure to use the screw provided could create an electrical hazard, which could result in death or serious injury to pool or spa users, installers or others due to electrical shock. -
Fill the pool until the underwater light is completely submerged in water before operating the light for more than 10 seconds. Turn on main switch or circuit breaker, as well as the switch, which operates the underwater light, to check for proper operation. Refer to Section 6, Operating Instructions.
WARNING
Never operate this underwater light for more than 10 seconds unless it is totally submerged in water. Without total submersion, the light assembly will get extremely hot, which may result in serious burns or in breakage of the bulb or lens. This may result in serious injury to pool or spa users, installers, or bystanders or in damage to property.
Section 5. Wiring Options for Controlling Jandy Pro series WaterColors
lED lights
NOTE The Jandy Pro series WaterColors lights will not operate properly
with light dimmers. Do not wire the Jandy Pro Series Lights to any dimming
circuitry.
To the extent allowed by code and capacity of the electrical equipment,
multiple Jandy Pro Series lights may be controlled with a single switch so
their colors will always be synchronized.
Separate switches may be used to control the on/off and color functions of
each Jandy Pro Series light. It is recommended that these switches be located
next to each other to facilitate simple color synchronization when desired.
All switches must be operated at the same time to assure color
synchronization. Otherwise, the lights will work independently of each other.
5.1 Wiring to an Aqualink® Rs Control system
The Jandy Pro Series WaterColors Lights can be wired into the Jandy Pro Series
AquaLink RS control system to provide simplified operation of the lights, as
well as a means to synchronize the color change function. Connect the lights
to one of the auxiliary relays in the Power Center.
NOTE It is recommended to connect one light per relay so each light can
be controlled separately. However, up to four lights can be connected on a
single relay. If there are more than four lights installed on one AquaLink RS
system, ensure there is more than one auxiliary relay available in the Power
Center.
Refer to Figures 2 and 3 to connect the Jandy Pro Series Color Lights to the
Power Center.
CAUTION
A Ground Fault Circuit Interrupter (GFCI) must be provided for 120 volt
models. The conductors on the load side of the GFCI circuit shall not occupy
conduit, boxes, or enclosures containing other conductors unless the
additional conductors are also protected by a GFCI. Refer to local codes for
complete details.
NOTE The Jandy Pro Series WaterColors Lights are available in 120-volt
and 12-volt versions. If installing a 12-volt light, a 120-volt/12-volt step-
down (AC) transformer must be used. For more information about 12-volt
installations, refer to Section 8 of this manual.
5.2 Wiring to a Time Clock
The Jandy Pro Series WaterColors Lights can be wired into a basic time clock
to automatically turn on the lights at a predesignated time. Refer to Figure 4
to connect the lights into the time clock.
5.3 Wiring to a switch
The Jandy Pro Series WaterColors Lights can be wired into a switch to manually
turn on/off the lights. Refer to Figure 5 to connect the lights into the
switch.
Section 6. Jandy Pro series WaterColors lED light Operating instructions
6.1 To Operate the light and Change Colors
Turn the light ON. The first time the light is turned on, the color sequence
begins with the Alpine White. To change the color, turn the light OFF and then
ON within three (3) seconds. Continue turning OFF and ON until the desired
light color mode is reached. See Table 1 for the color mode sequence.
Table 1. Jandy Pro series WaterColors lights sequence
Sequence Order|
Color Modes
---|---
1| Alpine White
2| Sky Blue
3| Cobalt Blue
4| Caribbean Blue
5| Spring Green
6| Emerald Green
7| Emerald Rose
8| Magenta
9| Violet
10| Slow Color Splash
11| Fast Color Splash
12| America the Beautiful
13| Fat Tuesday
14| Disco Tech
NOTE When the light is turned OFF for more than seven (7) seconds, it will remain in the color set that is currently active. When the light is turned back ON, the light will be on the same color set. Figure 2. 120-Volt Jandy Pro series WaterColors light Wiring Diagram Figure 3. 12-Volt Jandy Pro series WaterColors light Wiring Diagram Figure 4. Wiring the Jandy Pro series WaterColors light to a Time ClockFigure 5. Wiring the Jandy Pro series WaterColors light to a switch
6.2 To Reset to the Beginning of the Color sequence
Turn the light OFF, wait four (4) to five (5) seconds, then turn ON, the
light will return to the beginning of the color cycle (Alpine White).
NOTE If an AquaLink RS control system is being used the color set can be
selected using the indoor controller.
NOTE To synchronize colors on multiple Jandy Pro Series WaterColors Light
systems wired to separate switches, perform the above actions on all of their
switches simultaneously. All Jandy Pro Series WaterColors Lights will
synchronize automatically if activated by the same switch. No other
accessories are required.
Section 7. Replacing light Engine (PCB)
WARNING
Always disconnect power to the color light at the circuit breaker before
servicing the light. Failure to do so could result in death or serious injury
to installer, serviceman, pool or spa users or others due to electrical shock.
-
Turn off the main electrical switch or circuit breaker, as well as the switch, which operates the underwater light.
-
Be sure to have the following items:
• A new lens gasket, P/N R0451101 for the large light or P/N R0400501 for the small light.
• A light engine. See Table 2 for specification.
WARNING
Replace light engine with the same type. Failure to replace the light engine with the same type will damage the light assembly and may cause an electrical hazard resulting in death or serious injury to pool or spa users, installers, or others due to electrical shock, and may also cause damage to property. Be sure the power is switched OFF before removing or installing PCB. Allow PCB to cool before replacing. -
To remove the light assembly, unscrew the special pilot screw at the top of the face ring, remove light assembly from niche and gently place assembly on the deck. It is not necessary to drain down the pool. See Figure 6.
Table 2. light specifications
** Jandy Pro Series Model| Fixture Voltage| Light Engine (PCB) Part Number
---|---|---
WaterColors Large Light| **
12 Volt AC
| ****
R0474000
WaterColors Large Light| ****
120 Volt AC
| ****
R0474100
WaterColors Small Light| ****
12 Volt AC
| ****
R0473900
WaterColors Small Light| ****
120 Volt AC
| ****
R0473900
WARNING
Be sure to keep the special pilot screw from this underwater light. This screw
mounts and electrically grounds the housing securely to the mounting ring and
wet niche. Failure to use the screw provided could create an electrical
hazard, which could result in death or serious injury to pool or spa users,
installers or others due to electrical shock.
-
Pool Clamp Removal.
a. Loosen the Phillips head screws (six (6) for small light, eight (8) for large light) to allow the bottom clamp to be removed from the face ring assembly. Do not remove the screws or the retaining rings. The retaining rings prevent the screws from falling free from the bottom clamp and also aid in ease of assembly.
b. Remove the bottom clamp, the face ring assembly, the glass lens, and the gasket from the fixture. Remove the gasket from the lens. Refer to Section 9, Exploded View and Replacement Parts. -
Light Engine Replacement
a. 12V Small Light Engine (PCB) Replacement
1. Remove two (2) nuts and two (2) washers.
2. Unplug the quick disconnect terminals from the light engine.
3. Remove the light engine from the light fixture.
4. Place new light engine into the fixture with the orientation shown in Figure 7.
5 Secure the light engine with one (1) nylon washer and one (1) nut. Torque to 12 in-lbs.
6. Place a nylon washer on the other stud and place the green ground wire terminal on the nylon washer and secure both with the nut. Torque to 12 in- lbs.
Figure 6. Removing the Jandy Pro series WaterColors light Assembly for light Engine Replacement
7. Plug in the quick disconnect wire (white for the 12V and red for the 120V) onto the terminal (AC1) of the light engine.
8. Plug in the quick disconnect wire (black for the 12V and blue for the 120V) onto terminal (AC2) of the light engine.
b. Large Light Engine (PCB) Replacement (120V and 12V)
1. Remove three (3) nuts and washers.
2. Unplug the quick disconnect terminals from the PCB.
3. Remove the light engine from the light fixture.
4. Place new light engine into the fixture with the orientation shown in Figure 8.
5 Secure the new light engine (PCB) with two (2) nylon washers and two (2) nuts. Torque to 12 in-lbs.
6. Plug in the white quick disconnect wire onto the terminal (J2) of the light engine.
7. Plug in black quick disconnect wire onto terminal (J6) of the light engine for the 12V models; or terminal (J3) of the light engine for 120V models.
8a. For 12V models, place a nylon washer on the stud and place the green ground wire terminal on the nylon washer and secure both with the nut. Torque to 12 in-lbs.
8b. For 120V models, place the green ground wire on the stud and secure with the nut. Torque to 12 in-lbs. -
Reassemble the fixture.
a. If not already done, remove the gasket from the glass lens and install a new gasket, P/N R0451101 for the large light and R0400501 for the small light, on the lens. On the small light, remove the diverger from the lens.
NOTE A new lens gasket must be used each time the light is reassembled.
WARNING
Risk of Electrical shock or Electrocution. Always install a new lens gasket whenever disassembling the light (Jandy Color Light Gasket P/N R0451101 for large light and P/N R0400501 for small light). Failure to do so may permit water to leak into the assembly, which could cause:
(a) An electrical hazard resulting in death or serious injury to pool or spa users, installers, or others due to electrical shock, or
(b) A malfunction of the Jandy WaterColors Light, which likewise could result in serious injury to pool or spa users, installers, or bystanders, or in damage to property. Figure 7. small light Engine (PCB) Replacement and Wiring
b. While holding the fixture upright, place the glass lens with the gasket on top of the fixture. Please note that the lens gasket is not symmetrical. Therefore, it must be installed correctly so that the lens can seal to the fixture housing. Place the gasket on the lens so that the thick molded side of the gasket will mate with the housing when
the lens is installed, see Figure 10. On the small light, replace the diverger by tucking the tabs between the lens and gasket.
nOTE Be sure to face the dull side of the diverger down towards the PCB.
c. Position the lens and gasket on the fixture. Place the face ring assembly over the lens and align the pilot screw with the small arrow mark on the face of the lens. Note that the small arrow mark on the face of the lens and the pilot screw of the face ring must be aligned with the arrow located on fixture label that reads, “Arrow on this label must line up with the pilot screw on the Face Ring”. See Figure 9.
d. While holding the aligned face ring assembly and fixture together, turn the assembly upside down and set it on the old gasket, using the old gasket as an assembly fixture. This will keep the lens and gasket assembly from being pushed out of the face ring while you secure it to the light fixture.
e. Spread the bottom clamp over the electrical cord and slide it onto the back of fixture to the top clamp.
f. Tighten the Phillips head screws (eight (8) for large light and six (6) for small light) on the light in alternating cross-pattern. Torque screws to approximately 20 in-lbs. Do not over-tighten.
g. Discard the old gasket. Figure 8. large light Engine (PCB) Replacement and Wiring -
Reinstall the Jandy Pro Series Light into niche fixture.
a. Coil the extra four (4) feet of cord around the fixture or into the base of the niche and place the light assembly into the niche.
b. Engage the retainer tab on the bottom of the face ring, then pivot the top of the fixture inward and tighten the special pilot screw.
WARNING
Use only the special pilot screw provided with this underwater light. This screw mounts and electrically grounds the housing securely to the mounting ring and wet niche. Failure to use the screw provided could create an electrical hazard, which could result in death or serious injury to pool or spa users, installers or others due to electrical shock. -
If pool is empty, fill the pool until the underwater light is completely submerged in water before operating the light for more than 10 seconds. Turn on main switch or circuit breaker, as well as the switch, which specifically operates the underwater light, to check for proper operation.
WARNING
Never operate this underwater light for more than 10 seconds unless it is totally submerged in water. Without total submersion, the light assembly will get extremely hot, which may result in serious burns or in damage to the light. This may result in serious injury to pool or spa users, installers, or bystanders or in damage to property. Figure 10. Cross section of Jandy Pro series WaterColors lED light
Section 8. Twelve (12) Volt installation
A separate 12-Volt AC Transformer is required on all 12Volt Models. For Jandy
Pro Series WaterColors Light use a 150-watt multi-tap 12-volt system per
light.
NOTE For optimum performance Jandy Pro Series recommends to use one
transformer per 12-volt light. To ensure maximum safety, it is strongly
recommended that a transformer that has been listed or recognized by a
Nationally Recognized Testing Laboratory (NRTL) for the application be used.
Section 9. Exploded View and Replacement Parts
9.1 Jandy Pro series large WaterColors lED light Figure 11. Jandy Pro series large WaterColors lED light Exploded View
DWG # | Part # | Description | Field Replaceable |
---|---|---|---|
1 | N/A | WaterColors Light Housing | NO – Purchase New Light |
2 | R0474000 | Light Engine PCB, 12V Large LED Light w/ Light Shaping Diverger |
YES
2| R0474100| Light Engine PCB, 120V Large LED Light W/ Light Shaping Diverger|
YES
3| R0451101| Silicone Gasket| YES
4| R0450601| Glass Lens| YES
5| R0450701| Clamp Assembly| YES
6| R0450801| Face Ring, Stainless Steel (SS)| YES
6| R0450802| Face Ring, Plastic, Whitet| YES
6| R0450803| Face Ring, Plastic, Black| YES
6| R0450804| Face Ring, Plastic, Gray| YES
6| R0450805| Face Ring, Plastic Set| YES
7| R0450901| Pilot Screw, with Retainer| YES
8| R0451001| Clamp Screws (8 Screws and 8 Retainers)| YES
9.2 Jandy Pro Series Small WaterColors LED Light
Figure 12. Jandy Pro Series Small WaterColors LED Light Exploded View
DWG #| Part #| Description|
Field Replaceable
---|---|---|---
1| N/A| WaterColors Light Housing| NO – Purchase New Light
2| R0473900| Light Engine, 12V/120V Small LED Light| YES
3| R0474200| Diverger, Light Shaping, Small LED Light| YES
4| R0400501| Silicone Gasket| YES
5| R0400601| Glass Lens| YES
6| R0451201| Clamp Assembly| YES
7| R0451301| Face Ring, Stainless Steel (SS)| YES
7| R0451302| Face Ring, Plastic, White| YES
7| R0451303| Face Ring, Plastic, Black| YES
7| R0451304| Face Ring, Plastic, Gray| YES
7| R0451305| Face Ring, Plastic Set| YES
8| R0450901| Pilot Screw, with Retainer| YES
9| R0451401| Clamp Screws (6 Screws and 6 Retainers)| YES
Zodiac Pool Systems, Inc.
2620 Commerce Way, Vista, CA 92081
1.800.822.7933 | www.ZodiacPoolSystems.com
ZODIAC®
is a registered trademark of Zodiac International, S.A.S.U., used under
license.
All trademarks referenced herein are the property of their respective owners.
©2012 Zodiac Pool Systems, Inc. H0305500 Rev B 1208
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>