LANCOM XS-6128QF 10G Fiber Aggregation Switch User Guide

June 9, 2024
LANCOM

LANCOM XS-6128QF 10G Fiber Aggregation Switch

Overview

➀ Configuration interfaces RJ-45 & micro USB (Console)
➁ Connect the configuration interface ➀ via the included serial configuration cable to the serial interface of the device you want to use for configuring / monitoring the switch. Alternatively use the interface ➁ with a suitable micro USB cable.

➂ USB interface
Connect a USB stick to the USB interface to store general configuration scripts or debug data.
You can also use this interface to upload a new firmware.

➃ SFP+ interfaces 1G / 10G
Insert suitable LANCOM SFP modules into the SFP+ interfaces 1 to 12.
Choose cables which are compatible with the SFP modules and connect them as described in the SFP modules mounting instructions www.lancom-systems.com /SFP-module-MI.

➄ SFP+ interfaces 1G / 10G (combo ports)
Insert suitable LANCOM SFP modules into the SFP+ interfaces 13 to 14.
Choose cables which are compatible with the SFP modules and connect them as described in the SFP modules mounting instructions www.lancom-systems.com /SFP-module-MI.

➅ TP Ethernet interfaces 1G / 2.5G / 5G / 10G (combo ports)
Connect the interfaces 13 to 14 via Ethernet cables to your PC or a LAN switch.

➆ SFP28 interfaces 10G / 25G (FleX ports)
Insert suitable LANCOM SFP28 or 10G SFP+ modules into the SFP28 interfaces 21 to 24. Choose cables which are compatible with the SFP28 / 10G SFP+ modules and connect them as described in the SFP modules mounting instructions www .lancom-systems.com/SFP-module-MI.

➇ QSFP+ interfaces 40G (FleX ports)
Plug suitable LANCOM QSFP+ modules into the QSFP+ interfaces 21 to 22. Select cables suitable for the QSFP+ modules and connect them as described in the SFP modules mounting instructions www.lancom-systems.com/SFP-module- MI.

Rear panel:

SFP-DD interfaces 25G / 50G
Insert LANCOM SFP-DD-DAC50 stacking cables into the SFP-DD interfaces 25 to 28. For decentralized stacking scenarios (stack-member switches are distributed over spatially separated locations) the use of LANCOM SFP28 modules is recommended.

2 slots for fan modules
To remove a fan module in case of defect, loosen the two knurled screws of the module and remove the module from the plug-in unit.
To install a new fan module, push it into the corresponding slot. Fasten the module to the switch housing with the knurled screws.
Please note that a defective fan should be replaced within 48h.

➈ Power supply module with mains connection socket (rear panel).
Supply the device with power via the power supply socket of the power supply module. Use the supplied power cord or a country-specific LANCOM power cord.
To remove the power supply module, disconnect the module from the power supply and then pull the plug out of the module. While pressing the release lever 12 to the left, you can pull the module out of the device by the handle 11 .

⑩ Additional slot for power supply module with mains connection socket (rear panel).
To install an additional power supply module, remove the corresponding module bay cover by loosening both associated screws and push the power supply module in as far as it will go until the release lever ⑫ audibly engages. Check by pulling the handle ⑪ that the module cannot be removed from the bay without the release lever ⑫ being pressed to the left.


Please observe the following when setting up the device
→ The mains plug of the device must be freely accessible.
→ Do not rest any objects on top of the device and do not stack multiple devices.
→ Keep the ventilation slots of the device clear of obstruction.

→ Mount the device with the enclosed rack mounting system in a free 19” slot of an appropriate server rack.
Both slide-in rails are attached as shown in the accompanying installation instructions www.lancom-systems.com/slide-in-MI.
→ Please note that support for third-party accessories (SFP and DAC) is not provided.

Before initial startup, please make sure to take notice of the information regarding the intended use in the enclosed installation guide!
Operate the device only with a professionally installed power supply at a nearby power socket that is freely accessible at all times.

Rear panel

➀ System / Fan / Stack

System: green Device operational
System: red Hardware error
Fan: red Fan error
Stack: off No connection
Stack: green As master device: port activated and connected to slave device
Stack: orange As slave device: port activated and connected to master device

➁ Reset button

5 sec. pressed Device restart
7-12 sec. pressed Configuration reset and device restart

➂ SFP+ ports 1G / 10 G

Off Port inactive or disabled
Green Link 10 Gbps
Green, blinking Data transfer, link 10 Gbps
Orange Link 1 Gbps
Orange, blinking Data transfer, link 1 Gbps

➃ SFP+ ports 1G / 10G (combo ports)

Off Port inactive or disabled
Green Link 10 Gbps
Green, blinking Data transfer, link 10 Gbps
Orange Link 1 Gbps
Orange, blinking Data transfer, link 1 Gbps

➄ TP Ethernet ports 1G / 2.5G / 5G / 10G (combo ports)

Off Port inactive oder disabled
Green left/ right Link 10 Gbps/ 1 Gbps
Green, blinking left / right Data transfer, link 10 Gbps / 1 Gbps
Orange left / right Link 2.5 / 5 Gbps

Link 100 Mbps
Orange, blinking left / right| Data transfer, link 2.5 / 5 Gbps Data transfer, link 100 Mbps

➄ TP Ethernet ports 1G / 2.5G / 5G / 10G (combo ports)

Off Port inactive oder disabled
Green Link 25 / 10 Gbps
Green, blinking Data transfer, link 25 / 10 Gbps
Orange Link 1 Gbps
Orange, blinking Data transfer, link 1 Gbps

➆ QSFP+ ports 40G (FleX ports)

Off Port inactive or disabled
Green Oink 40 Gbps
Green, blinking Data transfer, link 40 Gbps

➇ SFP-DD stacking ports 25G (SFP28) / 50G

Off Port inactive or disabled
Green Link 50 Gbps
Green, blinking Data transfer, link 50 Gbps
Orange Link 25 I 10 Gbps
Orange,blinking Data transfer, link 25 / 10 Gbps

➈ Power supply unit LED

Off No primary voltage supply
Green Secondary voltage supply OK
Orange Critical power supply event that causes a shutdown:

→ OCP
→ OVP
→ fan failure
In case of parallel primary voltage supply by second power supply unit:
→ power cable disconnected or power failure
Orange, blinking| Power supply warning event in which the power supply continues to operate:
→ high temperature
→ high power
→ high current consumption
→ slow fan

Hardware

Power supply Exchangeable power supply (110-230 V, 50 – 60 H z)
Power consumption max. 105 watts
Environment Temperature range 0- 40°C, humidity 10- 90%; n on – condensing
Housing Robust metal housing, 19″ 1U (442 x 44 x 375 mm> W x H x D), network

connectors on the front
Number of fans| 2 exchangeable fan modules

Interfaces

SFP-DD 4 * SFP-DD (25 / 50 Gbps) stacking ports
QSFP+ / SFP28 2 QSFP+ (40 Gbps)/ 4 SFP28 (10 / 25 Gbps) FleX uplink ports

for connecting higher-le- vel core switches, content servers, or data centers
SFP+ / TP-Ethernet Combo-Ports| Each 4 SFP+ (1 / 10 Gbps) / TP-Ethernet (1 / 2.5 / 5 / 10 Gbps) combo ports for use as additional downlink ports or for connection to a NAS or router
SFP+| 16
SFP+ (1 / 10 Gbps) downlink ports for aggregation of subordinate access switches
Console| 1 RJ-45 / 1 Micro USB
USB| 1 * USB

Package Content

Mounting material| Rack mounting system consisting of 2 mounting brackets for front mounting and 2 slide-in rails for optional rear mounting of the switch in the rack.
---|---
Power supply| 1x exchangeable power supply LANCOM SPSU-250, expandable to 2 LANCOM SPSU-250 power supplies (hot swappable, for redundancy operation)
Fan modules| 2 fan modules LANCOM SFAN-XS6, already mounted
Cables| 1 IEC power cord, 1 serial configuration cable, 1 micro USB configuration cable

Hereby, LANCOM Systems GmbH | Adenauerstrasse 20/B2 | D-52146 Wuerselen, declares that this device is in compliance with Directives 2014/30/EU, 2014/35/EU, 2011/65/EU, and Regulation (EC) No. 1907/2006. The full text of the EU Declaration of Conformity is available at the following Internet address: www.lancom-systems.com/doc