LANCOM XS-6128QF 10G Fiber Aggregation Switch User Guide
- June 9, 2024
- LANCOM
Table of Contents
LANCOM XS-6128QF 10G Fiber Aggregation Switch
Overview
➀ Configuration interfaces RJ-45
& micro USB (Console)
➁ Connect the configuration interface ➀ via the included serial configuration
cable to the serial interface of the device you want to use for configuring /
monitoring the switch. Alternatively use the interface ➁ with a suitable micro
USB cable.
➂ USB interface
Connect a USB stick to the USB interface to store general configuration
scripts or debug data.
You can also use this interface to upload a new firmware.
➃ SFP+ interfaces 1G / 10G
Insert suitable LANCOM SFP modules into the SFP+ interfaces 1 to 12.
Choose cables which are compatible with the SFP modules and connect them as
described in the SFP modules mounting instructions www.lancom-systems.com
/SFP-module-MI.
➄ SFP+ interfaces 1G / 10G (combo ports)
Insert suitable LANCOM SFP modules into the SFP+ interfaces 13 to 14.
Choose cables which are compatible with the SFP modules and connect them as
described in the SFP modules mounting instructions www.lancom-systems.com
/SFP-module-MI.
➅ TP Ethernet interfaces 1G / 2.5G / 5G / 10G (combo ports)
Connect the interfaces 13 to 14 via Ethernet cables to your PC or a LAN
switch.
➆ SFP28 interfaces 10G / 25G (FleX ports)
Insert suitable LANCOM SFP28 or 10G SFP+ modules into the SFP28 interfaces 21
to 24. Choose cables which are compatible with the SFP28 / 10G SFP+ modules
and connect them as described in the SFP modules mounting instructions www
.lancom-systems.com/SFP-module-MI.
➇ QSFP+ interfaces 40G (FleX ports)
Plug suitable LANCOM QSFP+ modules into the QSFP+ interfaces 21 to 22. Select
cables suitable for the QSFP+ modules and connect them as described in the SFP
modules mounting instructions www.lancom-systems.com/SFP-module-
MI.
Rear panel:
SFP-DD interfaces 25G / 50G
Insert LANCOM SFP-DD-DAC50 stacking cables into the SFP-DD interfaces 25 to
28. For decentralized stacking scenarios (stack-member switches are
distributed over spatially separated locations) the use of LANCOM SFP28
modules is recommended.
2 slots for fan modules
To remove a fan module in case of defect, loosen the two knurled screws of the
module and remove the module from the plug-in unit.
To install a new fan module, push it into the corresponding slot. Fasten the
module to the switch housing with the knurled screws.
Please note that a defective fan should be replaced within 48h.
➈ Power supply module with mains connection socket (rear panel).
Supply the device with power via the power supply socket of the power supply
module. Use the supplied power cord or a country-specific LANCOM power cord.
To remove the power supply module, disconnect the module from the power supply
and then pull the plug out of the module. While pressing the release lever 12
to the left, you can pull the module out of the device by the handle 11 .
⑩ Additional slot for power supply module with mains connection socket
(rear panel).
To install an additional power supply module, remove the corresponding module
bay cover by loosening both associated screws and push the power supply module
in as far as it will go until the release lever ⑫ audibly engages. Check by
pulling the handle ⑪ that the module cannot be removed from the bay without
the release lever ⑫ being pressed to the left.
Please observe the following when setting up the device
→ The mains plug of the device must be freely accessible.
→ Do not rest any objects on top of the device and do not stack multiple
devices.
→ Keep the ventilation slots of the device clear of obstruction.
→ Mount the device with the enclosed rack mounting system in a free 19” slot
of an appropriate server rack.
Both slide-in rails are attached as shown in the accompanying installation
instructions www.lancom-systems.com/slide-in-MI.
→ Please note that support for third-party accessories (SFP and DAC) is not
provided.
Before initial startup, please make sure to take notice of the information
regarding the intended use in the enclosed installation guide!
Operate the device only with a professionally installed power supply at a
nearby power socket that is freely accessible at all times.
Rear panel
➀ System / Fan / Stack
System: green | Device operational |
---|---|
System: red | Hardware error |
Fan: red | Fan error |
Stack: off | No connection |
Stack: green | As master device: port activated and connected to slave device |
Stack: orange | As slave device: port activated and connected to master device |
➁ Reset button
5 sec. pressed | Device restart |
---|---|
7-12 sec. pressed | Configuration reset and device restart |
➂ SFP+ ports 1G / 10 G
Off | Port inactive or disabled |
---|---|
Green | Link 10 Gbps |
Green, blinking | Data transfer, link 10 Gbps |
Orange | Link 1 Gbps |
Orange, blinking | Data transfer, link 1 Gbps |
➃ SFP+ ports 1G / 10G (combo ports)
Off | Port inactive or disabled |
---|---|
Green | Link 10 Gbps |
Green, blinking | Data transfer, link 10 Gbps |
Orange | Link 1 Gbps |
Orange, blinking | Data transfer, link 1 Gbps |
➄ TP Ethernet ports 1G / 2.5G / 5G / 10G (combo ports)
Off | Port inactive oder disabled |
---|---|
Green left/ right | Link 10 Gbps/ 1 Gbps |
Green, blinking left / right | Data transfer, link 10 Gbps / 1 Gbps |
Orange left / right | Link 2.5 / 5 Gbps |
Link 100 Mbps
Orange, blinking left / right| Data transfer, link 2.5 / 5 Gbps Data transfer,
link 100 Mbps
➄ TP Ethernet ports 1G / 2.5G / 5G / 10G (combo ports)
Off | Port inactive oder disabled |
---|---|
Green | Link 25 / 10 Gbps |
Green, blinking | Data transfer, link 25 / 10 Gbps |
Orange | Link 1 Gbps |
Orange, blinking | Data transfer, link 1 Gbps |
➆ QSFP+ ports 40G (FleX ports)
Off | Port inactive or disabled |
---|---|
Green | Oink 40 Gbps |
Green, blinking | Data transfer, link 40 Gbps |
➇ SFP-DD stacking ports 25G (SFP28) / 50G
Off | Port inactive or disabled |
---|---|
Green | Link 50 Gbps |
Green, blinking | Data transfer, link 50 Gbps |
Orange | Link 25 I 10 Gbps |
Orange,blinking | Data transfer, link 25 / 10 Gbps |
➈ Power supply unit LED
Off | No primary voltage supply |
---|---|
Green | Secondary voltage supply OK |
Orange | Critical power supply event that causes a shutdown: |
→ OCP
→ OVP
→ fan failure
In case of parallel primary voltage supply by second power supply unit:
→ power cable disconnected or power failure
Orange, blinking| Power supply warning event in which the power supply
continues to operate:
→ high temperature
→ high power
→ high current consumption
→ slow fan
Hardware
Power supply | Exchangeable power supply (110-230 V, 50 – 60 H z) |
---|---|
Power consumption | max. 105 watts |
Environment | Temperature range 0- 40°C, humidity 10- 90%; n on – condensing |
Housing | Robust metal housing, 19″ 1U (442 x 44 x 375 mm> W x H x D), network |
connectors on the front
Number of fans| 2 exchangeable fan modules
Interfaces
SFP-DD | 4 * SFP-DD (25 / 50 Gbps) stacking ports |
---|---|
QSFP+ / SFP28 | 2 QSFP+ (40 Gbps)/ 4 SFP28 (10 / 25 Gbps) FleX uplink ports |
for connecting higher-le- vel core switches, content servers, or data centers
SFP+ / TP-Ethernet Combo-Ports| Each 4 SFP+ (1 / 10 Gbps) / TP-Ethernet (1 /
2.5 / 5 / 10 Gbps) combo ports for use as additional downlink ports or for
connection to a NAS or router
SFP+| 16 SFP+ (1 / 10 Gbps) downlink ports for aggregation of subordinate
access switches
Console| 1 RJ-45 / 1 Micro USB
USB| 1 * USB
Package Content
Mounting material| Rack mounting system consisting of 2 mounting brackets for
front mounting and 2 slide-in rails for optional rear mounting of the switch
in the rack.
---|---
Power supply| 1x exchangeable power supply LANCOM SPSU-250, expandable to 2
LANCOM SPSU-250 power supplies (hot swappable, for redundancy operation)
Fan modules| 2 fan modules LANCOM SFAN-XS6, already mounted
Cables| 1 IEC power cord, 1 serial configuration cable, 1 micro USB
configuration cable
Hereby, LANCOM Systems GmbH | Adenauerstrasse 20/B2 | D-52146 Wuerselen, declares that this device is in compliance with Directives 2014/30/EU, 2014/35/EU, 2011/65/EU, and Regulation (EC) No. 1907/2006. The full text of the EU Declaration of Conformity is available at the following Internet address: www.lancom-systems.com/doc
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>