This 2 zone programmer is designed to provide ON/OFF control for one hot water
and one heating zone, with the value added application of in built frost
protection.
CAUTION! Installation and connection should only be carried out by a
qualified person and in accordance with national wiring regulations.
- Before commencing any work on the electrical connections, you must first disconnect the programmer from the mains. None of the 230V connections must be live until the installation has been completed and the housing is closed. Only qualified electricians or authorised service staff are permitted to open the programmer. Disconnect from mains supply in the event of any damage to any buttons.
- There are parts that carry mains voltage behind the cover. The programmer must not be left unsupervised when open. (Prevent non specialists and especially children from gaining access to it.)
- If the programmer is used in a way not specified by the manufacturer, its safety may be impaired.
- Prior to setting the timeswitch, it is neccessary to complete all required settings described in this section.
- Never remove this product from the electrical baseplate. Do not use sharp tools to push any button.
This programmer can be mounted in the following ways:
- Directly wall mounted
- Mounted to a recessed conduit box
Contents
- Factory default settings
- Specifications & wiring
- Master reset
Factory default settings
Contacts: | 230 Volt contacts |
---|---|
Program: | 5/2D |
Backlight: | On |
Keypad: | Unlocked |
Frost Protection: | Off |
Clock type: | 24 Hr Clock |
Day-Light Saving
Specifications & wiring
Power Supply: | 230 Vac |
---|---|
Ambient Temp: | 0~35°C |
Contact Rating: | 250 Vac 3A(1A) |
Program Memory backup: | 1 year |
Battery: | 3Vdc Lithium LIR 2032 |
Backlight: | Blue |
IP rating: | IP20 |
Backplate: | British System Standard |
Pollution degree 2: | Resistance to voltage surge 2000V as per EN 60730 |
Automatic Action: | Type 1.8 |
Software: | Class A |
Master reset
Lower the cover on the front of the programmer. There are four hinges holding
the cover in place.
Between the 3rd and 4th hinges there is a circular hole. Insert a ball point
pen or similar object to master reset the programmer.
After pressing the master reset button, the date and time will now need to be
reprogrammed.
EPH Controls Ireland
technical@ephcontrols.com
www.ephcontrols.com
EPH Controls UK
technical@ephcontrols.co.uk
www.ephcontrols.co.uk
20221107_R27-HW_Insins_PK
Documents / Resources
| EPH
CONTROLS R27-HW 2 Zone
Programmer
[pdf] Instruction Manual
R27-HW 2 Zone Programmer, R27-HW 2, Zone Programmer, Programmer
---|---
| EPH
CONTROLS R27-HW 2 Zone
Programmer
[pdf] Instruction Manual
R27-HW 2 Zone Programmer, R27-HW, 2 Zone Programmer, Zone Programmer,
Programmer
| EPH
CONTROLS R27 HW 2 Zone
Programmer
[pdf] Instructions
R27 HW 2 Zone Programmer, R27 HW 2, Zone Programmer, Programmer
| EPH
CONTROLS R27-HW 2 Zone
Programmer
[pdf] Instruction Manual
R27-HW, R27-HW 2 Zone Programmer, 2 Zone Programmer, Programmer
| EPH
CONTROLS R27-HW 2 Zone
Programmer
[pdf] Instruction Manual
R27-HW 2 Zone Programmer, R27-HW, 2 Zone Programmer, Programmer
| EPH
CONTROLS R27-HW 2 Zone
Programmer
[pdf] Instruction Manual
R27-HW 2 Zone Programmer, R27-HW, R27-HW Programmer, 2 Zone Programmer,
Programmer
| EPH
CONTROLS R27-HW 2 Zone
Programmer
[pdf] Instruction Manual
R27-HW, R27-HW 2 Zone Programmer, 2 Zone Programmer, Programmer
| EPH
CONTROLS R27-HW 2 Zone
Programmer
[pdf] Instructions
R27-HW 2 Zone Programmer, R27-HW, 2 Zone Programmer, Zone Programmer,
Programmer
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>