REGENCY PTO30 Outdoor Fireplace Instruction Manual

June 9, 2024
Regency

REGENCY PTO30 Outdoor Fireplace Instruction Manual

PTO30 Outdoor Fireplace

MODEL PTO30-NG11 PTO30-LPG11
Fuel Type Natural Gas Propane
Minimum Supply Pressure 5” W.C. (1.25 kPa) 11” W.C. (2.73 kPa)
Manifold Pressure – High 3.5” W.C. (0.87 kPa) 10” W.C. (2.49 kPa)
Manifold Pressure – Low 1.6” W.C. (0.40 kPa) 6.4” W.C. (1.59 kPa)
Orifice Size – Altitude 0-4500 ft # 25 DMS # 45 DMS

Minimum Input

Altitude 0-4500 ft. (0-1372m)

| 30,000Btu/h (8.79 kW)| 38,000 Btu/h

(11.13 kW)

Maximum Input

Altitude 0-4500 ft. (0-1372m)

| 50,000 Btu/h

(14.65 kW)

| 49,000 Btu/h

(14.36 kW)

Vent Sizing| No Vent| No Vent

PTO30 UNIT DIMENSIONS

PTO60 UNIT DIMENSIONS

NOTE: PTO60 is two PTO30 units assembled end to end (see PT060 assembly for more details).

FINISHING

Side nailing strips are adjustable for material from a minimum of 1/2” thick up to a maximum of 2-3/8” thick.
The finishing materials cannot extend beyond the height of the burner

Side nailing strips are adjustable in 1/4” or 1/8” increments. Each hole on the inside line is 1/8”, each hole on the outside line is 1/4”.
Determine the thickness of the finishing material before adjusting the nailing strips

FINISHING MATERIALS:

This burner is designed to be finished with non-combustible materials (ie. tile, granite, marble, brick, etc.) with a minimum thickness of 1/2” to a maximum thickness of 2-3/8

Important Note: Two (2) ventilation grills, (PTO30), Four (4) ventilation grills (PTO60) are required for all enclosures.
This is to alleviate moisture and allow for air to circulate. Minimum recommended size : 20” sq (508 mm ²) each.

OPTIONAL FINISHING TRIM

Optional finishing trim is supplied with the PTO30 – place finishing trim on unit between unit and finishing material.
Note: If installing a PTO60 the optional trim on the PTO30 cannot be used and should be discarded. An optional trim (part number 377-957) can be purchased for the PTO60.

MINIMUM CLEARANCES TO COMBUSTIBLES

The clearances listed below are minimum distances unless otherwise stated.
A major cause of fires is failure to maintain required clearances (air space) to combustible materials. It is of the greatest importance that this fireplace be installed only in accordance with thes
instructions.

Caution Requirements

The top, back and sides of the fireplace are defined by standoffs. The metal ends of the standoff may NOT be recessed into combustible construction.

WARNING

Fire hazard is an extreme riskif these clearances (air space) to combustible materials are not adhered to. It is of greatest importance that this fireplace be
installed only in accordance with these instructions

PTO30/PT060 Clearance Requirements

Clearances Dimension Measured From:

A: Back wall

B: Sidewall C: Ceiling

| 17″ (432mm)

17″ (432mm)

45″ (1143mm)

| Burner to back wall

Burner to sidewall Burner to Ceiling

D: Unit Base| 1″(25mm)| Unit Base to Combustible
E1: Alcove Width 30″ E2: Alcove Width 60″| 84″(2134mm)

100″ (2540mm)

| Wall to Wall (Minimum)
F: Alcove Depth| 60″ (1524mm)| Front to Back Wall (Maximum)
Notes:| 0″| No Hearth Required

PTO30-11 Outdoor Fireplace
INNER FRAMING DIMENSIONS (REQUIRED) NOTE:FRAMING MATERIAL NOT SUPPLIED

PTO60

PTO30-11 Outdoor Fireplace