REGENCY PTO30 Outdoor Fireplace Instruction Manual
PTO30 Outdoor Fireplace
MODEL | PTO30-NG11 | PTO30-LPG11 |
---|---|---|
Fuel Type | Natural Gas | Propane |
Minimum Supply Pressure | 5” W.C. (1.25 kPa) | 11” W.C. (2.73 kPa) |
Manifold Pressure – High | 3.5” W.C. (0.87 kPa) | 10” W.C. (2.49 kPa) |
Manifold Pressure – Low | 1.6” W.C. (0.40 kPa) | 6.4” W.C. (1.59 kPa) |
Orifice Size – Altitude 0-4500 ft | # 25 DMS | # 45 DMS |
Minimum Input
Altitude 0-4500 ft. (0-1372m)
| 30,000Btu/h (8.79 kW)| 38,000 Btu/h
(11.13 kW)
Maximum Input
Altitude 0-4500 ft. (0-1372m)
| 50,000 Btu/h
(14.65 kW)
| 49,000 Btu/h
(14.36 kW)
Vent Sizing| No Vent| No Vent
PTO30 UNIT DIMENSIONS
PTO60 UNIT DIMENSIONS
NOTE: PTO60 is two PTO30 units assembled end to end (see PT060 assembly for
more details).
FINISHING
Side nailing strips are adjustable for material from a minimum of 1/2” thick
up to a maximum of 2-3/8” thick.
The finishing materials cannot extend beyond the height of the burner
Side nailing strips are adjustable in 1/4” or 1/8” increments. Each hole on
the inside line is 1/8”, each hole on the outside line is 1/4”.
Determine the thickness of the finishing material before adjusting the nailing
strips
FINISHING MATERIALS:
This burner is designed to be finished with non-combustible materials (ie. tile, granite, marble, brick, etc.) with a minimum thickness of 1/2” to a maximum thickness of 2-3/8
Important Note: Two (2) ventilation grills, (PTO30), Four (4) ventilation
grills (PTO60) are required for all enclosures.
This is to alleviate moisture and allow for air to circulate. Minimum
recommended size : 20” sq (508 mm ²) each.
OPTIONAL FINISHING TRIM
Optional finishing trim is supplied with the PTO30 – place finishing trim on
unit between unit and finishing material.
Note: If installing a PTO60 the optional trim on the PTO30 cannot be used and
should be discarded. An optional trim (part number 377-957) can be purchased
for the PTO60.
MINIMUM CLEARANCES TO COMBUSTIBLES
The clearances listed below are minimum distances unless otherwise stated.
A major cause of fires is failure to maintain required clearances (air space)
to combustible materials. It is of the greatest importance that this fireplace
be installed only in accordance with thes
instructions.
Caution Requirements
The top, back and sides of the fireplace are defined by standoffs. The metal ends of the standoff may NOT be recessed into combustible construction.
WARNING
Fire hazard is an extreme riskif these clearances (air space) to combustible
materials are not adhered to. It is of greatest importance that this fireplace
be
installed only in accordance with these instructions
PTO30/PT060 Clearance Requirements
Clearances | Dimension | Measured From: |
---|
A: Back wall
B: Sidewall C: Ceiling
| 17″ (432mm)
17″ (432mm)
45″ (1143mm)
| Burner to back wall
Burner to sidewall Burner to Ceiling
D: Unit Base| 1″(25mm)| Unit Base to Combustible
E1: Alcove Width 30″ E2: Alcove Width 60″| 84″(2134mm)
100″ (2540mm)
| Wall to Wall (Minimum)
F: Alcove Depth| 60″ (1524mm)| Front to Back Wall (Maximum)
Notes:| 0″| No Hearth Required
PTO30-11 Outdoor Fireplace
INNER FRAMING DIMENSIONS (REQUIRED) NOTE:FRAMING MATERIAL NOT SUPPLIED
PTO60
PTO30-11 Outdoor Fireplace