GoGEN ME 2930 Weather Station User Manual
- June 8, 2024
- Gogen
Table of Contents
**GoGEN ME 2930 Weather Station User Manual
**
FEATURES
Weather Forecast
- Two Weather Icon
- Sunny, Slightly Cloudy, Cloudy, Rainy and Snow animation
Time
- Radio Controlled Time DCF77, 77,5 kHz
- Perpetual Calendar Up to Year 2099
- Day of week in 8 languages user selectable
- Daily Alarm Function
Humidity
- Indoor & Outdoor measurable range: 20 ~ 99% Outdoor Humidity Record from Start-Up/Reset, and the corresponded time
- 24 Hours Min/Max Display for Outdoor Humidity
Temperature
- Indoor measurable range: −10 ~ 50 °C
- Measures °C/ °F user selectable
- Outdoor measurable range: −20 ~ 50 °C
- Outdoor Temperature Record from Start-Up/Reset, and the corresponded time
- 24 Hours Min/Max Display for Outdoor Temperature
- Comfort Indicator Bar
Wireless Outdoor Sensor
- Low-battery indicator for Outdoor Thermo Sensor
- Wall Mount or Table Stand
- One Wireless Thermo Sensor Included
- 433,9 MHz RF transmitting frequency, E.i.r.p. 0,19 mW
- 50 meter transmission range in an open area
MAIN UNIT APPEARANCE
Part A – LCD
A1: Radio control icon
A2: Date
A3: Time
A4: Current weather condition
A5: Weather forecast
A6: Outdoor temperature
A7: Outdoor humidity
A8: Past 24 hours highest & lowest temperature record
A9: Past 24 hours highest & lowest humidity record
A10: Indoor temperature
A11: Indoor humidity
A12: Comfort indicator
Part B – Buttons
B1: “▼/ (C/F) ” button
B2: “MODE/SET” button
B3: “▲/ button
B4: “SNOOZE/DIMMER” button
B5: “MEMORY” button
B6: “RF SEARCH” button
B7: “WEATHER” button
B8: “OUT-TEMP ALERT” button
B9: “RESET” button
Part C – Structure
C1: Battery Cover
OUTDOOR THERMO SENSOR
D1: Transmission Indication LED
D2: Outdoor Temperature display
D3: Outdoor Humidity display
D4: Battery Compartment
D5: Wall Mount Hole
D6: “RESET” button
D7: “C/F” button
D8: Temperature Probe Plug & Jack
D9: Stand
GETTING STARTED
Main Unit
Remove battery compartment door and insert 2 pcs AA size battery. Or connect the power cord to the wall outlet. Before connecting the unit to power, please make sure your local voltage is the same as marked on the adaptor.
Note
-
When powered by battery only, backlight would be off. Press snooze button, backlight will last
for around 5 seconds. -
When connecting with the adaptor on the premise that batteries have been installed correctly, this product will switch to the external power supply automatically.
Outdoor Thermo Sensor
- Batteries compartment (D4) of thermo sensor is locating behind the back cover,
- Insert 2x AAA batteries observing polarity [“+” and “−” marks]
INSTALLATION
Main Unit
The main unit can be placed onto any flat surface.
Outdoor Thermo sensor
The remote sensor should be securely mounted onto a horizontal surface.
Note
Transmissions between receiver and transmitter can reach up to 50m in open
area. Open Area: there are no interfering obstacles such as buildings, trees,
vehicles, high voltage lines, etc.
WEATHER FORECAST FUNCTION
Operation
- After Batteries inserted, or holding “WEATHER” button (B7) for 3 seconds, weather icon flash (A4) on the LCD. Enter the current weather by pressing “▼” or “▲“ button. Press “WEATHER” (B7) button to confirm the setting. The weather forecast may not be accurate if the current weather entered is not correct.
- There are two weather icons, the upper one indicates current weather condition, the lower one forecasts the weather in terms of getting better or worse. The weather station will start the first forecast at around 6 hours later after the current weather status is entered.
- The current weather status should be entered again if the altitude of the Main Unit is changed. (Barometric pressure is lower at higher altitude location. Therefore, altitude change will affect the weather forecast).
Weather Conditions
There are totally 5 different weather status animations in the weather forecast.
Note:
- “Freezing or snow” is shown if the weather forecast is Rainy and outdoor temperature (any channel) under 0 °C.
- Frost Alert: “ ” is shown if the outdoor temperature (any channel) is between −2 °C ~ +3 °C.
- If there is any inconsistency of weather forecast between Local Weather Station and this unit, the Local Weather Station’s forecast should prevail. The manufacture will not hold responsible for any trouble that may come up due to wrong forecasting from this unit.
THERMOMETER
RF Transmission Procedure:
- The main unit automatically starts receiving transmission from outdoor thermo sensor for outdoor temperature & humidity after weather condition setting.
- The outdoor sensor will automatically transmit temperature and humidity signal to the main unit after batteries inserted.
- If main unit failed to receive transmission from outdoor thermo sensor in first 3 minutes after the batteries inserted (“- – . –” display on the LCD), hold “RF SEARCH” button (B6) for 3 seconds to receive transmission manually. RF icon “ ”.
Temperature & Humidity
(1) Past 24 Hours Maximum/Minimum Outdoor Temperature and Humidity
- After start up, the unit automatically shows past 24 hours the highest & lowest outdoor temperature and humidity record. “HI” & “LO” show on the LCD
(2) Recorded highest & lowest Outdoor Temperature and Humidity from Start- up/Reset
- Press “MEMORY” button (B5) to view the maximum and minimum temperature and humidity record from start-up or reset. “ ” flash on the LCD.
- When viewing the memory record, hold “MEMORY” button for 3 seconds to clear the maximum and minimum record.
- When viewing the memory record, press “MEMORY” button (B5) again to check the corresponded time and date for memory maximum and minimum temperature & humidity record. The memory record value and corresponded time and date flash. Press “MEMORY” button select to view: Time & date for lowest temperature memory record, Time and date for highest temperature memory record, Time & date for lowest humidity memory record, Time and date for highest humidity memory record.
(3) Celsius/Fahrenheit
- Press “°C/ °F” button (B1) to select Indoor/Outdoor Temperature in Celsius mode or Fahrenheit mode.
- If the temperature is out of the measurable range, LL.L (beyond the minimum temperature) or HH.H (beyond the maximum temperature) will be shown on the LCD.
(4) Humidity
- The humidity measurable range is 20% ~ 99%. If the current humidity measurement is lower than 20%, the LCD would display .
(5) Outdoor Temperature Alert Function
-
Press “OUT-TEMP ALERT” button (B8) to select to activate or deactivate outdoor temperature
alert function. -
Press ALERT button select to: Active outdoor upper temperature alert, the icon “ ” besides outdoor temperature digit would display. Active outdoor upper& lower temperature alert, the icon “ ” besides outdoor temperature digit would display. Active outdoor lower temperature alert, the icon “ “ besides outdoor temperature digit would display. Deactivate outdoor temperature alert, alert icon disappear.
-
Hold “OUT-TEMP ALERT” button (B8) for 3 seconds to enter outdoor temperature alert setting. Icon “ ” or “ ” beside Temperature’s digits flash. Press “▼” or “▲“button to adjust the setting value, press “OUT-TEMP ALERT” button (B8) to confirm the setting. Setting Sequence as follow: Upper limit of temperature, Lower limit of Temperature.
-
When it’s alert, the corresponding icon “ ” or “ ” and temperature digit would flash on the LCD. Press any buttons to stop the alert sound, otherwise, it will sound for 2 minutes, and stop automatically.
(6) Comfort Indicator Bar
(A12) for the display of pleasant/unpleasant climate.
(7) The use of 1.5 m cord Temperature Probe
- Insert the probe plug (D 8) to the jack on the right hand side of the Thermo Sensor Unit.
- Put the cable outside and leave the Thermo Sensor Unit indoor to avoid freezing up the battery when the outdoor temperature is below −20 °C.
- Always use the temperature probe to sense the temperature when the temperature is between the following range: −50 °C ~ 0 °C and +50 °C ~ +70 °C
TIME AND ALARM SETTING
Radio Controlled Clock:
- • After batteries inserted and main unit finishes receiving the transmission from outdoor sensor, the clock automatically starts to scan the DCF time signal. Radio Control Icon “ “ flashes on the LCD.
flashes | turns on | disappear |
---|---|---|
Indicating now is receiving DCF signal | Indicating signal received | |
successfully | Indicating signal reception failed |
- The clock automatically scans the time signal at 3.00 a.m. every day to maintain accurate timing. If reception fail, scanning stops (“ “ on LCD disappear).
- The clock can be set to scan the time signal manually by holding “▼” and “▲“button for 3 seconds. Each reception takes about 5 minutes. If receptions fail, scanning stops.
- Stop scanning by holding “▼” and “▲“button for 3 seconds.
- “ “ shown on the LCD if it is in daylight saving time mode.
Manual Time Setting:
- Hold “MODE” button (B2) for 3 seconds to enter Clock /Calendar setting mode.
- Press “▲” or “▼” button to adjust the setting and press “MODE” button (B2) to confirm each setting.
- (By keeping the “▲” or “▼” button pressed, could accelerate the process and reach the desired value more quickly)
- The setting sequence is shown as follow: 12/24 Hour, Time Zone, Hour, Minutes, Second, Year, Month, Day, Day-of-week language.
- 8 languages can be selected in Day-of-week, they are: German, French, Spanish, Italian, Dutch, Danish, Russian, and English.
- The languages and their selected abbreviations for each day of the week are shown in the following table:
Language| Sunday| Monday| Tuesday| Wednesday|
Thursday| Thursday| Saturday
---|---|---|---|---|---|---|---
German, GE| SO| MO| DI| MI| DO| FR| SA
English, EN| SU| MO| TU| WE| TH| FR| SA
Russian, RU| BC| ПН| BT| CP| ЧТ| ПТ| СБ
Danish, DA| SO| MA| TI| ON| TO| FR| LO
Dutch, NE| ZO| MA| DI| WO| DO| VR| ZA
Italian, IT| DO| LU| MA| ME| GI| VE| SA
Spanish, ES| DO| LU| MA| MI| JU| VI| SA
French, FR| DI| LU| MA| ME| JE| VE| SA
Note
- Second adjusted to zero only.
- The Time Setting Mode will automatically exit in 15 seconds without any adjustment.
- The Time zone is used for the countries where can receive the DCF time signal but the time zone is different from the German time. When the country time is faster than the German time for 1 hour, the zone should be set to +1. Then the clock will automatically set 1 hour faster from the signal time received.
Daily Alarm Function
-
Press “ MODE/SET” button (B2) to select to view:
Time ® Time & Day of Week ® Alarm Time ( “AL” shown on theLCD) - When viewing the Alarm Time, hold „MODE“ button (B2) for 3 seconds to enter Alarm Time setting. Press“▲” or “▼” button to adjust the alarm time. Press „MODE“ button (B2) to confirm the setting.
- Press „ “ button (B3) to switch alarm on or off. If it is on, „ “ shown on the LCD.
- When Alarming, alarm icon „ “ flash. Press „SNOOZE“ button (B4) to activate the snooze alarm, („
- “ flash on the LCD). The alarm will snooze for around 5 minutes, then it alarms again. This snooze function can be enabled for maximum 7 times.
- Except „SNOOZE“ button, press any buttons to stop the snooze alarm. Otherwise, the alarm signal sounds for about 2 minutes, and then stops automatically.
LIGHT
Press “DIMMER” button (B4) to adjust the LED brightness.
LOW BATTERY INDICATION
The low battery icon “ “ will appear l indicating that thermo sensor is in low battery status. The batteries should be replaced.
PRECAUTIONS
- Use a pin to press the reset button (B9) if the Unit does not work properly.
- Avoid placing the clock near interference sources /metal frames such as computer or TV sets.
- The clock loses its time information when the battery is removed.
- Do not expose it to direct sunlight, heavy heat, cold, high humidity or wet areas.
- The outdoor sensor must not be set up and installed under water. Set it up in away direct sunlight and Rain.
- Never clean the device using abrasive or corrosive materials or products. Abrasive cleaning agents may scratch plastic parts and corrode electronic circuits.
- If there is any inconsistency of weather forecast between Local Weather Station and this unit, the Local Weather Station’s forecast should prevail. The manufacturer will not take responsible for incorrect forecasting from this unit.
WE RESERVE THE RIGHT TO CHANGE TECHNICAL SPECIFICATIONS.
WARNING: DO NOT USE THIS PRODUCT NEAR WATER, IN WET AREAS TO AVOID FIRE OR INJURY OF ELECTRIC CURRENT. ALWAYS TURN OFF THE PRODUCT WHEN YOU DON’T USE IT OR BEFORE A REVISION. THERE AREN’T ANY PARTS IN THIS APPLIANCE WHICH ARE REPARABLE BY CONSUMER. ALWAYS APPEAL TO A QUALIFIED AUTHORIZED SERVICE. THE PRODUCT IS UNDER A DANGEROUS TENTION.
TO AVOID DANGER OF SUFFOCATION, KEEP THE PLASTIC BAG AWAY FROM BABIES AND CHILDREN. DO NOT USE THIS BAG IN CRIBS, BEDS, CARRIAGES OR PLAYPENS. THIS BAG IS NOT A TOY.
Disposal of old Electrical & Electronic Equipment (Applicable in the European Union and other European countries with separate collection systems)
This symbol on the product or on its packaging indicates that this product shall not be treated as household waste. Instead it shall be handed over to the applicable collection point for the recycling of electrical and electronic equipment. By ensuring this product is disposed of correctly, you will help prevent potential negative consequences for the environment and human health, which could otherwise be caused by inappropriate waste handling of this product. The recycling of materials will help to conserve natural resources. For more detailed information about recycling of this product, please contact your local Civic Office, your household waste disposal service or the shop where you purchased the product.
Hereby, ETA a.s. declares that the radio equipment type ME2930 is in compliance with Directive 2014/53/EU. The full text of the EU declaration of conformity is available atthe following internet address: http://www.gogen.cz/declaration_of_conformity
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>