Lenovo Flex System Fabric CN4093 10Gb Converged Scalable Switch User Guide
- June 3, 2024
- Lenovo
Table of Contents
Lenovo Flex System Fabric CN4093 10Gb Converged Scalable Switch
Flex System Fabric CN4093 10Gb Converged Scalable Switch
Product Guide (withdrawn product)
The Flex System® Fabric CN4093 10Gb Converged Scalable Switch provides
unmatched scalability, port flexibility, performance, convergence, and network
virtualization, while also delivering innovations to help address a number of
networking concerns today and providing capabilities that will help you
prepare for the future. The switch offers full Layer 2/3 switching as well as
FCoE Full Fabric and Fibre Channel NPV Gateway operations to deliver a truly
converged integrated solution, and it is designed to install within the I/O
module bays of the Flex System Enterprise Chassis. The switch can help clients
migrate to a 10 GbE or 40 GbE converged Ethernet infrastructure and offers
virtualization features like Virtual Fabric and VMready®.
Figure 1 shows the Flex System Fabric CN4093 10Gb Converged Scalable Switch.
Figure 1. Flex System Fabric CN4093 10Gb Converged Scalable Switch
Did you know?
The CN4093 offers up to 12 external Omni Ports, which provide extreme
flexibility with the choice of SFP+ based 10 Gb Ethernet connectivity or 4/8
Gb Fibre Channel connectivity, depending on the SFP+ module used.
The base switch configuration comes standard with 22x 10 GbE port licenses
that can be assigned to internal connections or external SFP+, Omni or QSFP+
ports with flexible port mapping. For example, this feature allows you to
trade off four 10 GbE ports for one 40 GbE port (or vice versa) or trade off
one external 10 GbE SFP+ or Omni port for one internal 10 GbE port (or vice
versa). You then have the flexibility of turning on more ports when you need
them using Lenovo Features on Demand upgrade licensing capabilities that
provide “pay as you grow” scalability without the need to buy additional
hardware.
Part number information
The CN4093 switch is initially licensed for 22x 10 GbE ports. Further ports
can be enabled with Upgrade 1 and Upgrade 2 license options. Upgrade 1 and
Upgrade 2 can be applied on the switch independently from each other or in
combination for full feature capability. Table 1 shows the part numbers for
ordering the switches and the upgrades.
Table 1. Part numbers and feature codes for ordering
Description | Part number | Feature code |
---|
Switch module
Flex System Fabric CN4093 10Gb Converged Scalable Switch| 00D5823| A3HH
Features on Demand upgrades
Flex System Fabric CN4093 Converged Scalable Switch (Upgrade 1)| 00D5845| A3HL
Flex System Fabric CN4093 Converged Scalable Switch (Upgrade 2)| 00D5847| A3HM
The part number for the switch includes the following items:
- One Flex System Fabric CN4093 10Gb Converged Scalable Switch
- Documentation package
Note: Neither QSFP+ nor SFP+ transceivers or cables are included with the
switch. They must be ordered separately (See Table 3).
The switch does not include a serial management cable. However, Flex System
Management Serial Access Cable, 90Y9338, is supported and contains two cables,
a mini-USB-to-RJ45 serial cable and a mini-USB-to-DB9 serial cable, either of
which can be used to connect to the switch locally for configuration tasks and
firmware updates.
The part numbers for the upgrades, 00D5845 and 00D5847, include the following
items:
- Features on Demand Activation Flyer
- Upgrade authorization letter
The base switch and upgrades are as follows:
-
00D5823 is the part number for the base switch, and it comes with 14 internal 10 GbE ports enabled (one to each node bay), two external 10 GbE SFP+ ports enabled, and six Omni Ports enabled to connect to either Ethernet or Fibre Channel networking infrastructure, depending on the SFP+ transceiver or DAC cable used.
00D5845 (Upgrade 1) can be applied on the base switch when you need more external bandwidth with two 40 GbE QSFP+ ports that can be converted into 4x 10 GbE SFP+ links each with the optional break-out cables. This upgrade also enables 14 additional internal ports, for a total of 28 internal ports, to provide more bandwidth to the compute nodes leveraging 4-port expansion cards. This takes full advantage of four-port adapter cards installed in each compute node and requires the base switch. -
00D5847 (Upgrade 2) can be applied on the base switch when you need more external Omni Ports on the switch or if you want additional internal bandwidth to the node bays. The upgrade will enable the remaining six external Omni Ports, plus 14 additional internal 10 GbE ports, for a total of 28 internal ports, to provide more bandwidth to the compute nodes leveraging four-port expansion cards. This takes full advantage of four-port adapter cards installed in each compute node and requires the base switch.
-
Both 00D5845 (Upgrade 1) and 00D5847 (Upgrade 2) can be applied on the switch at the same time to allow you to use 42 internal 10 GbE ports leveraging six ports on an eight-port expansion card, and to utilize all external ports on the switch.
-
Flexible port mapping: With Networking OS version 7.8 or later clients have more flexibility in assigning ports that they have licensed on the CN4093 which can help eliminate or postpone the need to purchase upgrades. While the base model and upgrades still activate specific ports, flexible port mapping provides clients with the capability of reassigning ports as needed by moving internal and external 10 GbE ports and Omni Ports, or trading off four 10 GbE ports for the use of an external 40 GbE port. This is very valuable when you consider the flexibility with the base license and with Upgrade 1 or Upgrade 2.
Note: Flexible port mapping is not available in Stacking mode.
With flexible port mapping, clients have licenses for a specific number of
ports:+
Note: When both Upgrade 1 and Upgrade 2 are activated, flexible port
mapping is no longer used because all the ports on the CN4093 are enabled.
Table 2 lists supported port combinations on the switch and required upgrades.
Table 2. Supported port combinations (Part 1: Default port mapping)
Supported port combinations | Quantity required |
---|---|
Base switch, 00D5823 | Upgrade 1, 00D5845 |
14x internal 10 GbE ports
2x external 10 GbE SFP+ ports 6x external SFP+ Omni Ports
| 1| 0| 0
28x internal 10 GbE ports
2x external 10 GbE SFP+ ports 6x external SFP+ Omni Ports
2x external 40 GbE QSFP+ ports
| 1| 1| 0
28x internal 10 GbE ports
2x external 10 GbE SFP+ ports 12x external SFP+ Omni Ports
| 1| 0| 1
42x internal 10 GbE ports†
2x external 10 GbE SFP+ ports 12x external SFP+ Omni Ports 2x external 40 GbE QSFP+ ports
| 1| 1| 1
† This configuration leverages six of the eight ports on the CN4058 adapter
available for IBM Power Systems™ compute nodes.
Table 2. Supported port combinations (Part 2: Flexible port mapping*)
Supported port combinations | Quantity required |
---|---|
Base switch, 00D5823 | Upgrade 1, 00D5845 |
22x 10 GbE ports (internal and external SFP+ and Omni Ports) or
18x 10 GbE ports (internal and external SFP+ and Omni Ports) 1x external 40 GbE QSFP+ ports
or
14x 10 GbE ports (internal and external SFP+ and Omni Ports) 2x external 40 GbE QSFP+ ports
| 1| 0| 0
44x 10 GbE ports (internal and external SFP+ and Omni Ports) or
40x 10 GbE ports (internal and external SFP+ and Omni Ports) 1x external 40 GbE QSFP+ ports
or
36x 10 GbE ports (internal and external SFP+ and Omni Ports) 2x external 40 GbE QSFP+ ports
| 1| 1| 0
42x 10 GbE ports (internal and external SFP+ and Omni Ports) or
38x 10 GbE ports (internal and external SFP+ and Omni Ports) 1x external 40 GbE QSFP+ ports
or
34x 10 GbE ports (internal and external SFP+ and Omni Ports) 2x external 40 GbE QSFP+ ports
| 1| 0| 1
-
Flexible port mapping is available in Networking OS 7.8 or later.
Supported transceivers and cables
With the flexibility of the CN4093 switch, clients can take advantage of the technologies that they require for multiple environments:-
For 1 GbE links, clients can use RJ-45 SFP transceivers with UTP cables up to 100 m. Clients that need longer distances can use a 1000BASE-SX transceiver, which can drive distances up to 220 meters by using 62.5 µ multi-mode fiber and up to 550 meters with 50 µ multi-mode fiber, or the 1000BASE-LX transceivers that support distances up to 10 kilometers using single-mode fiber (1310 nm).
-
For 10 GbE (supported on external SFP+ ports), you can use SFP+ direct attach copper (DAC) cables for in-rack cabling and distances up to 7 m (up to 5 m for Omni Ports). These DAC cables have SFP+ connectors on each end, and they do not need separate transceivers. For longer distances the 10GBASE-SR transceiver can support distances up to 300 meters over OM3 multimode fiber or up to 400 meters over OM4 multimode fiber. The 10GBASE-LR transceivers can support distances up to 10 kilometers on single mode fiber.
To increase the number of available 10 GbE ports, clients can split out four 10 GbE ports for each 40 GbE port using QSFP+ DAC breakout cables for distances up to 5 meters. For distances up to 100 m, the 40GBASE-iSR4 QSFP+ transceivers can be used with OM3 optical MTP-to-LC break-out cables or up to 150 m with OM4 optical MTP-to-LC break-out cables. For longer distances, the 40GBASE-eSR4 transceivers can be used with OM3 optical break-out cables for distances up to 300 m or OM4 optical break-out cables for distances up to 400 m. -
For 40 GbE to 40 GbE connectivity, clients can use the affordable QSFP+ to QSFP+ DAC cables for distances up to 7 meters. For distances up to 100 m, the 40GBASE-SR4/iSR4 QSFP+ transceivers can be used with OM3 multimode fiber or up to 150 m when using OM4 multimode fiber. For distances up to 300 m, the 40GBASE-eSR4 QSFP+ transceiver can be used with OM3 multimode fiber or up to 400 m when using OM4 multimode fiber. For distances up to 10 km, the 40GBASE-LR QSFP+ transceiver can be used with single mode fiber.
-
For 4 Gb or 8 Gb FC links (supported on Omni Ports only), you can use 8 Gb FC SFP+ SW optical transceivers plus LC fiber optics cables for distances up to 150 m with 50 µ multi-mode fiber or up to 21 m with 62.5 µ multi-mode fiber. These transceivers can operate at 4 Gb or 8 Gb speeds.
-
Table 3 lists the supported cables and transceivers.
Table 3. Supported transceivers and direct-attach cables
Description| Part number| Feature code| Maximum
quantity supported
---|---|---|---
Serial console cables
Flex System Management Serial Access Cable Kit| 90Y9338| A2RR| 1
SFP transceivers – 1 GbE
Lenovo 1000BASE-T SFP Transceiver (does not support 10/100 Mbps)| 00FE333|
A5DL| 2
Lenovo 1000BASE-SX SFP Transceiver| 81Y1622| 3269| 2
Lenovo 1000BASE-LX SFP Transceiver| 90Y9424| A1PN| 2
SFP+ transceivers – 10 GbE
Lenovo 10GBASE-SR SFP+ Transceiver| 46C3447| 5053| 14
Lenovo 10GBASE-LR SFP+ Transceiver| 90Y9412| A1PM| 14
Optical cables for 1 GbE SX SFP, 10 GbE SR SFP+, and 8 Gb FC SW SFP+
transceivers
Lenovo 1m LC-LC OM3 MMF Cable| 00MN502| ASR6| 14
Lenovo 3m LC-LC OM3 MMF Cable| 00MN505| ASR7| 14
Lenovo 5m LC-LC OM3 MMF Cable| 00MN508| ASR8| 14
Lenovo 10m LC-LC OM3 MMF Cable| 00MN511| ASR9| 14
Lenovo 15m LC-LC OM3 MMF Cable| 00MN514| ASRA| 14
Lenovo 25m LC-LC OM3 MMF Cable| 00MN517| ASRB| 14
Lenovo 30m LC-LC OM3 MMF Cable| 00MN520| ASRC| 14
SFP+ direct-attach cables – 10 GbE
Lenovo 1m Passive SFP+ DAC Cable| 90Y9427| A1PH| 14
Lenovo 1.5m Passive SFP+ DAC Cable| 00AY764| A51N| 14
Lenovo 2m Passive SFP+ DAC Cable| 00AY765| A51P| 14
Lenovo 3m Passive SFP+ DAC Cable| 90Y9430| A1PJ| 14
Lenovo 5m Passive SFP+ DAC Cable| 90Y9433| A1PK| 14
Lenovo 7m Passive SFP+ DAC Cable| 00D6151| A3RH| 2*
QSFP+ transceiver and cables – 40 GbE
Lenovo 40GBASE-SR4 QSFP+ Transceiver| 49Y7884| A1DR| 2
Lenovo 40GBASE-iSR4 QSFP+ Transceiver| 00D9865| ASTM| 2
Lenovo 40GBASE–eSR4 QSFP+ Transceiver| 00FE325| A5U9| 2
Lenovo 40GBASE-LR4 QSFP+ Transceiver| 00D6222| A3NY| 2
Optical cables for 40 GbE QSFP+ SR4/iSR4/eSR4 transceivers
Description| Part number| Feature code| Maximum
quantity supported
---|---|---|---
Lenovo 10m QSFP+ MTP-MTP OM3 MMF Cable| 90Y3519| A1MM| 2
Lenovo 30m QSFP+ MTP-MTP OM3 MMF Cable| 90Y3521| A1MN| 2
Lenovo 10m QSFP+ MTP-MTP OM3 MMF Cable (replaces 90Y3519)| 00VX003| AT2U| 2
Lenovo 30m QSFP+ MTP-MTP OM3 MMF Cable (replaces 90Y3521)| 00VX005| AT2V| 2
Optical breakout cables for 40 GbE QSFP+ iSR4/eSR4 transceivers
Lenovo 1m MTP-4xLC OM3 MMF Breakout Cable| 00FM412| A5UA| 2
Lenovo 3m MTP-4xLC OM3 MMF Breakout Cable| 00FM413| A5UB| 2
Lenovo 5m MTP-4xLC OM3 MMF Breakout Cable| 00FM414| A5UC| 2
QSFP+ breakout cables – 40 GbE to 4×10 GbE
Lenovo 1m Passive QSFP+ to SFP+ Breakout DAC Cable| 49Y7886| A1DL| 2
Lenovo 3m Passive QSFP+ to SFP+ Breakout DAC Cable| 49Y7887| A1DM| 2
Lenovo 5m Passive QSFP+ to SFP+ Breakout DAC Cable| 49Y7888| A1DN| 2
QSFP+ direct-attach cables – 40 GbE
Lenovo 1m Passive QSFP+ DAC Cable| 49Y7890| A1DP| 2
Lenovo 3m Passive QSFP+ DAC Cable| 49Y7891| A1DQ| 2
Lenovo 5m Passive QSFP+ DAC Cable| 00D5810| A2X8| 2
Lenovo 7m Passive QSFP+ DAC Cable| 00D5813| A2X9| 2
SFP+ transceivers – 8 Gb FC (supported in Omni Ports)
8Gb SFP+ SW Optical Transceiver (supports 4/8 Gbps)| 44X1964| 5075| 12
Supported in SFP+ ports only, not supported in Omni Ports.
Benefits
The Flex System Fabric CN4093 10Gb Converged Scalable Switch is considered
particularly suited for these clients:
- Clients who want to implement a converged infrastructure with FCoE where the CN4093 acts as a Full Fabric FC/FCoE switch for the end-to-end FCoE configurations or as an integrated Fibre Channel Forwarder (FCF) NPV Gateway breaking out FC traffic within the chassis for the native Fibre Channel SAN connectivity.
- Clients who are implementing a virtualized environment.
- Clients who require investment protection for 40 GbE external ports.
- Clients who want to reduce TCO and improve performance while maintaining high levels of availability and security.
- Clients who want to avoid or minimize oversubscription, which can result in congestion and loss of performance.
The switch offers the following key capabilities and benefits:
-
Convergence and lower acquisition and operational costs One of the key trends that is driving the transformation of the data center is converging to a simplified networking infrastructure — collapsing Ethernet and Fibre Channel at the server and the edge of the network while maintaining connectivity upstream to existing LANs and SANs. The CN4093 Converged Switch supports multiple protocols, including Ethernet, Fibre Channel, iSCSI, and FCoE; Omni Ports give clients the flexibility to choose between 10 Gb Ethernet external connections to the top-of-rack switch and 4/8 Gb Fibre Channel for flexible and scalable access to FC storage.
-
Increased performance With the growth of virtualization and the evolution of cloud, many of today’s applications require low latency and high bandwidth performance. The CN4093 is the embedded 10 GbE switch for a Flex System chassis to support sub-microsecond latency and up to 1.28 Tbps, while also delivering full line rate performance on Ethernet ports, making it ideal for managing dynamic workloads across the network. In addition, this switch provides a rich Layer 2 and Layer 3 feature set that is ideal for many of today’s data centers. Furthermore, it offers industry-leading external bandwidth by being the integrated switch to support 40 GbE external ports.
Pay as you grow investment protection and lower total cost of ownership The CN4093’s flexible port mapping allows you to buy only the ports that you need, when you need them. The base switch configuration includes 22x 10 GbE port licenses that can be assigned to internal connections and external SFP+, Omni or 40 GbE QSFP+ ports (by using four 10 GbE licenses per one 40 GbE port). You then have the flexibility of turning on more internal 10 GbE connections and more external ports when you need them using Features on Demand licensing capabilities, that provide “pay as you grow” scalability without the need for additional hardware. -
Cloud ready – Optimized network virtualization with virtual NICs With the majority of IT organizations implementing virtualization, there has been an increased need to reduce the cost and complexity of their environments. Lenovo is helping to address these requirements by removing multiple physical I/O ports. Virtual Fabric provides a way for companies to carve up 10 GbE ports into virtual NICs (vNICs) to meet those requirements with Intel processor-based compute nodes.
To help deliver maximum performance per vNIC and to provide higher availability and security with isolation between vNICs, the switch leverages capabilities of its Networking Operating System. For large-scale virtualization, the Flex System solution can support up to 32 vNICs by using a pair of CN4054 10Gb Virtual Fabric Adapters in each compute node and four CN4093 10Gb Converged Scalable Switches in the chassis.
The CN4093 offers the benefits of next-generation vNIC – Unified Fabric Port (UFP). UFP is an advanced, cost-effective solution that provides a flexible way for clients to allocate, reallocate, and adjust bandwidth to meet their ever-changing data center requirements. -
Cloud ready – VM-aware networking
Delivering advanced virtualization awareness helps simplify management and automates VM mobility by making the network VM aware with VMready, which works with all the major hypervisors. For companies using VMware, SDN for Virtual Environments (sold separately) enables network administrators to simplify management by having a consistent virtual and physical networking environment. With SDN VE, virtual and physical switches use the same configurations, policies, and management tools. Network policies migrate automatically along with virtual machines (VMs) to ensure that security, performance, and access remain intact as VMs move from compute node to compute node.
Support for Edge Virtual Bridging (EVB) based on the IEEE 802.1Qbg standard enables scalable, flexible management of networking configuration and policy requirements per VM and eliminates many of the networking challenges introduced with server virtualization. -
Simplify network infrastructure
The CN4093 10Gb Converged Scalable Switch simplifies deployment and growth by using its innovative scalable architecture. This architecture helps increase return on investment by reducing the qualification cycle, while providing investment protection for additional I/O bandwidth requirements in the future. The extreme flexibility of the switch comes from the ability to turn on additional ports as required, both down to the compute node and for upstream connections (including 40 GbE). Also, as you consider migrating to a converged LAN and SAN, the CN4093 supports Omni Ports for Ethernet or FC connectivity, and it can operate as an integrated FCF, which can be leveraged in an FCoE converged environment. -
CN4093 hybrid stacking capabilities simplify management for clients by stacking up to eight switches (two CN4093 and from two to six EN4093/EN4093R switches) that share one IP address and one management interface. Support for Switch Partition (SPAR) allows clients to virtualize the switch with partitions that isolate communications for multi-tenancy environments.
-
Transparent networking capability
With a simple configuration change to “easy connect” mode, the CN4093 becomes a transparent network device, invisible to the core, eliminating network administration concerns of Spanning Tree Protocol configuration/interoperability, VLAN assignments and avoidance of possible loops.
By emulating a host NIC to the data center core, it accelerates the provisioning of VMs by eliminating the need to configure the typical access switch parameters. -
Integrate network management
A key challenge is the management of a discrete network environment. The CN4093 supports a command-line interface (CLI) for integration into existing scripting and automation. Network management can be simplified by using port profiles, topology views, and virtualization management.
System Center is used for more advanced levels of management and control, which can significantly reduce deployment and day-to-day maintenance times, while providing in-depth visibility into the network performance and operations of Lenovo switches. Furthermore, when leveraging tools like VMware vCenter Server or vSphere, Switch Center provides additional integration for better optimization.
Features and specifications
The Flex System Fabric CN4093 10Gb Converged Scalable Switch has the following features and specifications:
-
Internal ports
- Forty-two internal full-duplex 10 Gigabit ports
- Two internal full-duplex 1 GbE ports connected to the Chassis Management Module
-
External ports
-
Two ports for 1 Gb or 10 Gb Ethernet SFP/SFP+ transceivers (support for 1000BASE-SX, 1000BASE-LX, 1000BASE-T, 10GBASE-SR, 10GBASE-LR, or SFP+ direct-attach copper (DAC) cables. SFP+ modules and DAC cables are not included and must be purchased separately.
-
Twelve Omni Ports, each of which can operate as a 10 Gb Ethernet (support for 10GBASE-SR, 10GBASE-LR, or 10 GbE SFP+ DAC cables), or auto-negotiating 4/8 Gb Fibre Channel, depending on the SFP+ transceiver installed in the port. SFP+ modules and DAC cables are not included and must be purchased separately.
Note: Omni Ports do not support 1 Gb SFP Ethernet transceivers. -
Two ports for 40 Gb Ethernet QSFP+ transceivers or QSFP+ DAC cables. In addition, you can use break-out cables to break out each 40 GbE port into four 10 GbE SFP+ connections. QSFP+ modules and DAC cables are not included and must be purchased separately.
-
One RS-232 serial port (mini-USB connector) that provides an additional means to configure the switch module.
-
-
Scalability and performance
-
40 Gb Ethernet ports for more external bandwidth and performance
-
Fixed-speed external 10 Gb Ethernet ports to leverage 10 GbE upstream infrastructure
-
Non-blocking architecture with wire-speed forwarding of traffic and aggregated throughput of 1.28 Tbps on Ethernet ports
-
Media access control (MAC) address learning: automatic update, support for up to 128,000 MAC addresses
Up to 128 IP interfaces per switch -
Static and LACP (IEEE 802.3ad) link aggregation, up to 220 Gb of total external bandwidth per switch, up to 64 trunk groups, up to 16 ports per group
-
Support for jumbo frames (up to 9,216 bytes)
-
Broadcast/multicast storm control
-
IGMP snooping to limit flooding of IP multicast traffic
-
IGMP filtering to control multicast traffic for hosts participating in multicast groups Configurable traffic distribution schemes over trunk links based on source/destination IP or MAC addresses, or both
-
Fast port forwarding and fast uplink convergence for rapid STP convergence
-
-
Availability and redundancy
- Virtual Router Redundancy Protocol (VRRP) for Layer 3 router redundancy
- IEEE 802.1D STP for providing L2 redundancy
- IEEE 802.1s Multiple STP (MSTP) for topology optimization; up to 32 STP instances are supported by a single switch
- IEEE 802.1w Rapid STP (RSTP) provides rapid STP convergence for critical delay-sensitive traffic such as voice or video
- Per-VLAN Rapid STP (PVRST) enhancements
- Layer 2 Trunk Failover to support active/standby configurations of network adapter teaming on compute nodes
- Hot Links provides basic link redundancy with fast recovery for network topologies that require Spanning Tree to be turned off
-
VLAN support
- Up to 4095 VLANs supported per switch, with VLAN numbers ranging from 1 to 4095 (4095 is used for management module’s connection only.)
- 802.1Q VLAN tagging support on all ports
- Private VLANs
-
Security
- VLAN-based, MAC-based, and IP-based access control lists (ACLs)
- 802.1x port-based authentication
- Multiple user IDs and passwords
- User access control
- Radius, TACACS+, and LDAP authentication and authorization NIST 800-131A Encryption
- Selectable encryption protocol; SHA 256 enabled as default IPv6 ACL metering
-
Quality of Service (QoS)
- Support for IEEE 802.1p, IP ToS/DSCP, and ACL-based (MAC/IP source and destination addresses, VLANs) traffic classification and processing
- Traffic shaping and re-marking based on defined policies
- Eight Weighted Round Robin (WRR) priority queues per port for processing qualified traffic
-
IP v4 Layer 3 functions
- Host management
- IP forwarding
- IP filtering with ACLs; up to 896 ACLs supported
- VRRP for router redundancy
- Support for up to 128 static routes
- Routing protocol support (RIP v1, RIP v2, OSPF v2, BGP-4); up to 2048 entries in a routing table
- Support for DHCP Relay
- Support for IGMP snooping and IGMP relay
- Support for Protocol Independent Multicast (PIM) in Sparse Mode (PIM-SM) and Dense Mode (PIM-DM)
-
IP v6 Layer 3 functions
- IPv6 host management (except default switch management IP address) IPv6 forwarding
- Up to 128 static routes
- Support for OSPF v3 routing protocol
- IPv6 filtering with ACLs
- Virtual Station Interface Data Base (VSIDB) support
-
Virtualization
- Virtual NIC (vNIC)
- Ethernet, iSCSI, or FCoE traffic is supported on vNICs Unified fabric port (UFP)
-
- Ethernet or FCoE traffic is supported on UFPs
- Supports up to 256 VLAN for the virtual ports
- Integration with L2 failover
- Virtual link aggregation groups (vLAGs)
- 802.1Qbg Edge Virtual Bridging (EVB) is an emerging IEEE standard for allowing networks to become virtual machine (VM)-aware.
- Virtual Ethernet Bridging (VEB) and Virtual Ethernet Port Aggregator (VEPA) are mechanisms for switching between VMs on the same hypervisor.
- Edge Control Protocol (ECP) is a transport protocol that operates between two peers over an IEEE 802 LAN providing reliable, in-order delivery of upper layer protocol data units. Virtual Station Interface (VSI) Discovery and Configuration Protocol (VDP) allows centralized configuration of network policies that will persist with the VM, independent of its location.
- EVB Type-Length-Value (TLV) is used to discover and configure VEPA, ECP, and VDP.
- VMready
- Switch partitioning (SPAR)
- SPAR forms separate virtual switching contexts by segmenting the data plane of the switch. Data plane traffic is not shared between SPARs on the same switch.
- SPAR operates as a Layer 2 broadcast network. Hosts on the same VLAN attached to a SPAR can communicate with each other and with the upstream switch. Hosts on the same VLAN but attached to different SPARs communicate through the upstream switch.
- SPAR is implemented as a dedicated VLAN with a set of internal compute node ports and a single external port or link aggregation (LAG). Multiple external ports or LAGs are not allowed in SPAR. A port can be a member of only one SPAR.
-
Converged Enhanced Ethernet
- Priority-Based Flow Control (PFC) (IEEE 802.1Qbb) extends 802.3x standard flow control to allow the switch to pause traffic based on the 802.1p priority value in each packet’s VLAN tag. Enhanced Transmission Selection (ETS) (IEEE 802.1Qaz) provides a method for allocating link bandwidth based on the 802.1p priority value in each packet’s VLAN tag.
- Data Center Bridging Capability Exchange Protocol (DCBX) (IEEE 802.1AB) allows neighboring network devices to exchange information about their capabilities.
- Multi-hop RDMA over Converged Ethernet (RoCE) with LAG support.
-
Fibre Channel and Fibre Channel over Ethernet (FCoE)
-
FC-BB-5 FCoE specification compliant
-
Native FC Forwarder (FCF) switch operations
-
End-to-end FCoE support (initiator to target)
-
FCoE Initialization Protocol (FIP) support
-
FCoE Link Aggregation Group (LAG) support
Optimized FCoE to FCoE forwarding
Omni Ports support 4/8 Gb FC when FC SFPs+ are installed in these ports
Support for F_port, E_Port ISL, NP_port and VF_port FC port types -
Full Fabric mode for end-to-end FCoE or FCoE gateway; NPV Gateway mode for external FC
-
SAN attachments (support for Brocade and Cisco MDS external SANs)
-
Sixteen buffer credits supported
-
Fabric Device Management Interface (FDMI)
-
NPIV support
-
Fabric Shortest Path First (FSPF)
-
Port security
-
Fibre Channel ping, debugging
-
Supports 2,000 secure FCoE sessions with FIP Snooping by using Class ID ACLs
-
Fabric services in Full Fabric mode:
-
Name Server
-
Registered State Change Notification (RSCN)
-
Login services
-
Zoning
-
-
Stacking
- Hybrid stacking support (from two to six EN4093/EN4093R switches with two CN4093 switches) – single IP management
- FCoE support
- FCoE LAG on external ports
- 802.1Qbg support
- vNIC and UFP support
- Support for UFP with 802.1Qbg
-
Manageability
-
Simple Network Management Protocol (SNMP V1, V2 and V3) HTTP browser GUI
Telnet interface for CLI -
SSH
-
Secure FTP (sFTP)
-
Service Location Protocol (SLP)
-
Serial interface for CLI
-
Scriptable CLI
-
Firmware image update (TFTP and FTP)
-
Network Time Protocol (NTP) for switch clock synchronization
-
-
Monitoring
- Switch LEDs for external port status and switch module status indication
- Remote Monitoring (RMON) agent to collect statistics and proactively monitor switch performance
- Port mirroring for analyzing network traffic passing through the switch
- Change tracking and remote logging with syslog feature
- Support for sFLOW agent for monitoring traffic in data networks (separate sFLOW analyzer required elsewhere)
- POST diagnostics
The following features are not supported with IPv6:
- Default switch management IP address
- SNMP trap host destination IP address
- Bootstrap Protocol (BOOTP) and DHCP
- RADIUS, TACACS+, and LDAP
- QoS metering and re-marking ACLs for out-profile traffic VMware Virtual Center (vCenter) for VMready
- Routing Information Protocol (RIP)
- Internet Group Management Protocol (IGMP)
- Border Gateway Protocol (BGP)
- Virtual Router Redundancy Protocol (VRRP)
- sFLOW
Standards supported
The CN4093 switch supports the following standards:
- IEEE 802.1AB Data Center Bridging Capability Exchange Protocol (DCBX) IEEE 802.1D Spanning Tree Protocol (STP)
- IEEE 802.1p Class of Service (CoS) prioritization
- IEEE 802.1s Multiple STP (MSTP)
- IEEE 802.1Q Tagged VLAN (frame tagging on all ports when VLANs are enabled) IEEE 802.1Qbg Edge Virtual Bridging
- IEEE 802.1Qbb Priority-Based Flow Control (PFC)
- IEEE 802.1Qaz Enhanced Transmission Selection (ETS)
- IEEE 802.1x port-based authentication
- IEEE 802.1w Rapid STP (RSTP)
- IEEE 802.3 10BASE-T Ethernet
- IEEE 802.3ab 1000BASE-T copper twisted pair Gigabit Ethernet
- IEEE 802.3ad Link Aggregation Control Protocol
- IEEE 802.3ae 10GBASE-KR backplane 10 Gb Ethernet
- IEEE 802.3ae 10GBASE-SR short range fiber optics 10 Gb Ethernet
- IEEE 802.3ae 10GBASE-LR long range fiber optics 10 Gb Ethernet
- IEEE 802.3ba 40GBASE-SR4 short range fiber optics 40 Gb Ethernet
- IEEE 802.3ba 40GBASE-CR4 copper 40 Gb Ethernet
- IEEE 802.3u 100BASE-TX Fast Ethernet
- IEEE 802.3x Full-duplex Flow Control
- IEEE 802.3z 1000BASE-SX short range fiber optics Gigabit Ethernet
- IEEE 802.3z 1000BASE-LX long range fiber optics Gigabit Ethernet
- SFF-8431 10GSFP+Cu SFP+ Direct Attach Cable
- FC-PH, Revision 4.3 (ANSI/INCITS 230-1994)
- FC-PH, Amendment 1 (ANSI/INCITS 230-1994/AM1 1996)
- FC-PH, Amendment 2 (ANSI/INCITS 230-1994/AM2-1999)
- FC-PH-2, Revision 7.4 (ANSI/INCITS 297-1997)
- FC-PH-3, Revision 9.4 (ANSI/INCITS 303-1998)
- FC-PI, Revision 13 (ANSI/INCITS 352-2002)
- FC-PI-2, Revision 10 (ANSI/INCITS 404-2006)
- FC-PI-4, Revision 7.0
- FC-FS, Revision 1.9 (ANSI/INCITS 373-2003)
- FC-FS-2, Revision 0.91
- FC-FS-3, Revision 1.11
- FC-LS, Revision 1.2
- FC-SW-2, Revision 5.3 (ANSI/INCITS 355-2001)
- FC-SW-3, Revision 6.6 (ANSI/INCITS 384-2004)
- FC-SW-5, Revision 8.5 (ANSI/INCITS 461-2010)
- FC-GS-3, Revision 7.01 (ANSI/INCITS 348-2001)
- FC-GS-4, Revision 7.91 (ANSI/INCITS 387-2004)
- FC-GS-6, Revision 9.4,(ANSI/INCITS 463-2010)
- FC-BB-5, Revision 2.0 for FCoE
- FCP, Revision 12 (ANSI/INCITS 269-1996)
- FCP-2, Revision 8 (ANSI/INCITS 350-2003)
- FCP-3, Revision 4 (ANSI/INCITS 416-2006)
- FC-MI, Revision 1.92 (INCITS TR-30-2002, except for FL-ports and Class 2)
- FC-MI-2, Revision 2.6 (INCITS TR-39-2005)
- FC-SP, Revision 1.6
- FC-DA, Revision 3.1 (INCITS TR-36-2004)
Chassis and adapters
The switches are installed in I/O module bays in the rear of the Flex System chassis, as shown in Figure 2. Switches are normally installed in pairs because ports on the I/O adapter cards installed in the compute nodes are routed to two I/O bays for redundancy and performance.
Figure 2. Location of the I/O bays in the Flex System chassis
The CN4093 switch can be installed in bays 1, 2, 3, and 4 of the Flex System
chassis. A supported adapter card must be installed in the corresponding slot
of the compute node. Each adapter can use up to four lanes to connect to the
respective I/O module bay. The CN4093 is able to use up to three of the four
lanes.
Prior to Networking OS 7.8, with four-port adapters, an optional Upgrade 1
(00D5845) or Upgrade 2 (00D5847) was required for the switch to allow
communications on all four ports. With eight-port adapters, both optional
Upgrade 1 (90Y3562) and Upgrade 2 (00D5847) were required for the switch to
allow communications on six adapter ports, and two remaining ports are not
used. With Networking OS 7.8 or later, there is no need to buy additional
switch upgrades for 4-port and 8-port adapters if the total number of port
licenses on the switch does not exceed the number of external (upstream
network ports) and internal (compute node network ports) connections used.
In compute nodes that have an integrated dual-port 10 GbE network interface
controller (NIC), NIC ports are routed to bays 1 and 2 with a specialized
periscope connector, and the adapter card is not required. However, when
needed, the periscope connector can be replaced with the adapter card. In this
case, integrated NIC will be disabled.
Table 4 shows compatibility information for the CN4093 and Flex System
chassis.
Table 4. Flex System chassis compatibility
Description| Part number| Enterprise Chassis with CMM|
Enterprise Chassis with CMM2| Carrier-grade Chassis with CMM2
---|---|---|---|---
Flex System Fabric CN4093 10Gb Converged Scalable Switch| 00D5823| Yes| Yes|
No
The midplane connections between the adapters installed in the compute nodes to the switch bays in the chassis are shown diagrammatically in the following figure. The figure shows both half-wide compute nodes, such as the x240 with two adapters, and full-wide compute nodes, such as the x440 with four adapters.
Figure 3. Logical layout of the interconnects between I/O adapters and
I/O modules
Table 5 shows the connections between adapters installed in the compute nodes
to the switch bays in the chassis.
Table 5. Adapter to I/O bay correspondence
I/O adapter slot
in the compute node
| Port on the adapter| Corresponding I/O module bay in the chassis
---|---|---
Bay 1| Bay 2| Bay 3| Bay 4
Slot 1| Port 1| Yes| | |
Port 2| | Yes| |
Port 3| Yes| | |
Port 4| | Yes| |
Port 5| Yes| | |
Port 6| | Yes| |
Port 7| | | |
Port 8| | | |
Slot 2| Port 1| | | Yes|
Port 2| | | | Yes
Port 3| | | Yes|
Port 4| | | | Yes
Port 5| | | Yes|
Port 6| | | | Yes
Port 7| | | |
Port 8| | | |
Slot 3
(full-wide compute nodes only)
| Port 1| Yes| | |
Port 2| | Yes| |
Port 3| Yes| | |
Port 4| | Yes| |
Port 5| Yes| | |
Port 6| | Yes| |
Port 7| | | |
Port 8| | | |
Slot 4
(full-wide compute nodes only)
| Port 1| | | Yes|
Port 2| | | | Yes
Port 3| | | Yes|
Port 4| | | | Yes
Port 5| | | Yes|
Port 6| | | | Yes
Port 7| | | |
Port 8| | | |
Ports 7 and 8 are routed to I/O bays 1 and 2 (Slot 1 and Slot 3) or 3 and 4
(Slot 2 and Slot 4), but these ports cannot be used with the CN4093.
The following table lists the adapters that are supported by the I/O module.
Table 6. Network adapters
Description | Part number | Feature code |
---|
50 Gb Ethernet
ThinkSystem QLogic QL45212 Flex 50Gb 2-Port Ethernet Adapter| 7XC7A05843| B2VT
ThinkSystem QLogic QL45262 Flex 50Gb 2-Port Ethernet Adapter with iSCSI/FCoE|
7XC7A05845| B2VV
25 Gb Ethernet
ThinkSystem QLogic QL45214 Flex 25Gb 4-Port Ethernet Adapter| 7XC7A05844| B2VU
10 Gb Ethernet
Embedded 10Gb Virtual Fabric Adapter (2-port)†| None| None
Flex System CN4022 2-port 10Gb Converged Adapter| 88Y5920| A4K3
Flex System CN4052 2-port 10Gb Virtual Fabric Adapter| 00JY800| A5RP
Flex System CN4052S 2-port 10Gb Virtual Fabric Adapter| 00AG540| ATBT
Flex System CN4052S 2-port 10Gb Virtual Fabric Adapter Advanced| 01CV780| AU7X
Flex System CN4054 10Gb Virtual Fabric Adapter (4-port)| 90Y3554| A1R1
Flex System CN4054R 10Gb Virtual Fabric Adapter (4-port)| 00Y3306*| A4K2
Flex System CN4054S 4-port 10Gb Virtual Fabric Adapter| 00AG590| ATBS
Flex System CN4054S 4-port 10Gb Virtual Fabric Adapter Advanced| 01CV790| AU7Y
Flex System CN4058S 8-port 10Gb Virtual Fabric Adapter| 94Y5160| A4R6
Flex System EN4172 2-port 10Gb Ethernet Adapter| 00AG530| A5RN
1 Gb Ethernet
Embedded 1 Gb Ethernet controller (2-port)**| None| None
Flex System EN2024 4-port 1Gb Ethernet Adapter| 49Y7900| A10Y
* Withdrawn from marketing
† The Embedded 10Gb Virtual Fabric Adapter is built into selected compute
nodes.
** The Embedded 1 Gb Ethernet controller is built into selected compute nodes.
The adapters are installed in slots in each compute node. Figure 4 shows the
locations of the slots in the x240
Compute Node. The positions of the adapters in the other supported compute
nodes are similar.
Figure 4. Location of the I/O adapter slots in the Flex System x240 Compute Node
Connectors and LEDs
Figure 5 shows the front panel of the Flex System Fabric CN4093 10Gb Converged
Scalable Switch.
Figure 5. Front panel of the Flex System Fabric CN4093 10Gb Converged Scalable Switch The following components are located on the front panel:
- LEDs that display the status of the switch module and the network:
- The OK LED indicates that the switch module has passed the power-on self-test (POST) with no critical faults and is operational.
- Identify: This blue LED can be used to identify the switch physically by illuminating via the management software.
- The error LED (switch module error) indicates that the switch module has failed the POST or detected an operational fault.
- One mini-USB RS-232 console port that provides an additional means to configure the switch module. This mini-USB-style connector enables connection of a special serial cable. (The cable is optional and it is not included with the switch. See the Part number information section for details.)
- Two external SFP/SFP+ ports for 1 GbE or 10 GbE connections to external Ethernet devices.
- Twelve external SFP+ Omni Ports for 10 GbE connections to the external Ethernet devices or 4/8 Gb FC connections to the external SAN devices.
- Two external QSFP+ port connectors to attach QSFP+ transceivers or cables for a single 40 GbE connectivity or for splitting of a single port into 4x 10 GbE connections.
- A link OK LED and a Tx/Rx LED for each external port on the switch module.
- A mode LED for each pair of Omni Ports indicating the operating mode. (OFF indicates the port pair is configured for Ethernet operation, and ON indicates the port pair is configured for Fibre Channel operation.)
Network cabling requirements
The network cables that can be used with the CN4093 switch are shown in Table
7.
Table 7. CN4093 network cabling requirements
Transceiver | Standard | Cable | Connector |
---|
40 Gb Ethernet
40GBASE-SR QSFP+
Transceiver (49Y7884)
| 40GBASE-SR4| 10 m or 30 m MTP fiber optics cables supplied by Lenovo (see
Table 3); support for up to 100 m (OM3 multimode fiber) or up to 150 m (OM4
multimode fiber)| MTP
40GBASE-iSR4 QSFP+
Transceiver (00D9865)
| 40GBASE-SR4| 10 m or 30 m MTP fiber optics cables or MTP-4xLC breakout
cables up to 5 m supplied by Lenovo (see Table 3); support for up to 100 m
with OM3 multimode fiber or up to 150 m with OM4 multimode fiber| MTP
40GBASE-eSR4 QSFP+
Transceiver (00FE325)
| 40GBASE-SR4| 10 m or 30 m MTP fiber optics cables or MTP-4xLC breakout
cables up to 5 m supplied by Lenovo (see Table 3); support for up to 300 m
with OM3 multimode fiber or up to 400 m with OM4 multimode fiber| MTP
40GBASE-LR4 QSFP+
Transceiver (00D6222)
| 40GBASE-LR4| 1310 nm single-mode fiber cable up to 10 km| LC
Direct attach cable| 40GBASE-CR4| QSFP+ to QSFP+ DAC cables up to 7 m; QSFP+
to 4x SFP+ DAC break-out cables up to 5 m for 4x 10 GbE SFP+ connections out
of a 40 GbE port (see Table 3)| QSFP+
10 Gb Ethernet
10GBASE-SR SFP+
Transceiver (46C3447, 00NU537)
| 10GBASE-SR| Up to 30 m with fiber cables supplied by Lenovo (see Table 3);
850 nm OM3 multimode fiber (50 µ or 62.5 µ) up to 300 m or up to 400 m with
OM4 multimode fiber| LC
10GBASE-LR SFP+
Transceiver (90Y9412)
| 10GBASE-LR| 1310 nm single-mode fiber cable up to 10 km| LC
Direct attach cable| 10GSFP+Cu| SFP+ DAC cables up to 7 m (see Table 3)| SFP+
1 Gb Ethernet
1000BASE-T SFP
Transceiver (00FE333)
| 1000BASE-T| UTP Category 5, 5E, and 6 up to 100 meters| RJ-45
1000BASE-SX SFP
Transceiver (81Y1622)
| 1000BASE-SX| Up to 30 m with fiber optic cables supplied by Lenovo (see
Table 3); 850 nm multimode fiber cable up to 550 m (50 µ) or up to 220 m (62.5
µ)| LC
1000BASE-LX SFP
Transceiver (90Y9424)
| 1000BASE-LX| 1310 nm single-mode fiber cable up to 10 km| LC
8 Gb Fibre Channel (operating at 8 Gbps or 4 Gbps)
8Gb SFP+ SW Optical Transceiver (44X1964)| FC-PI-4 (8GFC, 4GFC)| Up to 30 m
with fiber optic cables supplied by Lenovo (see Table 3); 850 nm multimode
fiber, 50 µ (up to 150 m at 8 Gbps; up to 380 m at 4 Gbps) or 62.5 µ (up to 21
m at 8 Gbps; up to 70 m at 4 Gbps)| LC
Management ports
External 1 GbE management port| 1000BASE-T| UTP Category 5, 5E, and 6 up to
100 meters| RJ-45
External RS-232 management port| RS-232| DB-9-to-mini-USB or RJ-45-to-mini-USB
console cable (comes with optional Management Serial Access Cable, 90Y9338)|
Mini-USB
Warranty
The switch carries a 1-year, customer-replaceable unit (CRU) limited warranty.
When installed in a chassis, the switch assumes your system’s base warranty
and any Lenovo warranty service upgrade for the system.
Physical specifications
These are the approximate dimensions and weight of the switch:
- Height: 30 mm (1.2 in.)
- Width: 401 mm (15.8 in.)
- Depth: 317 mm (12.5 in.)
- Weight: 3.7 kg (8.1 lb)
Shipping dimensions and weight (approximate):
- Height: 114 mm (4.5 in.)
- Width: 508 mm (20.0 in.)
- Depth: 432 mm (17.0 in.)
- Weight: 4.1 kg (9.1 lb)
Agency approvals
The switches conform to the following standards:
- United States FCC 47 CFR Part 15, Subpart B, ANSI C63.4 (2003), Class A IEC/EN 60950-1, Second Edition
- Canada ICES-003, issue 4, Class A
- Japan VCCI, Class A
- Australia/New Zealand AS/NZS CISPR 22:2006, Class A
- Taiwan BSMI CNS13438, Class A
- CE Mark (EN55022 Class A, EN55024, EN61000-3-2, EN61000-3-3) CISPR 22, Class A
- China GB 9254-1998
- Turkey Communique 2004/9; Communique 2004/22
- Saudi Arabia EMC.CVG, 28 October 2002
Typical configurations
The following usage scenarios are described:
- CN4093 FCoE Virtual Fabric in the Full Fabric mode (end-to-end FCoE) CN4093 FCoE Virtual Fabric in the NPV
- Gateway mode (FC Forwarder)
- CN4093 with flexible port mapping (4-port network adapter example)
CN4093 FCoE Virtual Fabric in the Full Fabric mode (end-to-end FCoE)
Figure 6. CN4093 Virtual Fabric in the Full Fabric mode (end-to-end FCoE)
The solution components used in the scenario depicted in Figure 6 are listed
in Table 8.
Diagram reference | Description | Part number | Quantity |
---|---|---|---|
Flex System end-to-end FCoE solution | |||
Flex System x240 Compute Node or other supported compute node | Varies | Varies | |
Flex System CN4054 10Gb Virtual Fabric Adapter | 90Y3554 | 1 per node | |
Flex System CN4054 Virtual Fabric Adapter Upgrade | 90Y3558 | 1 per VFA | |
Flex System Fabric CN4093 10Gb Converged Scalable Switch | 00D5823 | 2 | |
Flex System Fabric CN4093 Converged Scalable Switch (Upgrade 1)* | 00D5845 | 1 |
per CN4093
| Flex System V7000 Storage Node
| RackSwitch G8264
The Upgrade 1 might not be needed with flexible port mapping if the total
number of the internal and external ports used on the CN4093 is less or equal
to 22.
Note: You also need SFP+ modules and optical cables or SFP+ DAC cables (not
shown in Table 8, see Table 3 for details) for the external 10 Gb Ethernet
connectivity.
CN4093 FCoE Virtual Fabric in the NPV Gateway mode
As part of an FCoE solution, the Flex System Fabric CN4093 10Gb Converged
Scalable Switch can operate as an integrated FC Forwarder in the NPV Gateway
mode, providing the capability to connect to the external Brocade or Cisco MDS
storage networks, as shown in Figure 7 and Figure 8.
Figure 8. CN4093 as an NPV Gateway connected to the Cisco MDS SAN
The solution components used in the scenarios depicted in Figure 7 and Figure
8 are listed in Table 9 and Table 10 respectively.
Table 9. CN4093 as an NPV Gateway connected to the Brocade SAN (Figure 7)
Diagram reference | Description | Part number | Quantity |
---|---|---|---|
Flex System FCoE solution | |||
Flex System x240 Compute Node or other supported compute node | Varies | Varies | |
Flex System CN4054 10Gb Virtual Fabric Adapter | 90Y3554 | 1 per compute node | |
Flex System CN4054 Virtual Fabric Adapter Upgrade | 90Y3558 | 1 per VFA | |
Flex System Fabric CN4093 10Gb Converged Scalable Switch | 00D5823 | 2 | |
Flex System Fabric CN4093 Converged Scalable Switch (Upgrade 1)* | 00D5845 | 1 |
per CN4093
| RackSwitch G8264
| Brocade SAN fabric
| Storage systems
IBM DS3000 / DS5000
IBM DS8000
IBM Storwize V3700 / V5000 / V7000 / SAN Volume Controller
IBM XIV
- The Upgrade 1 might not be needed with flexible port mapping if the total number of the internal and external ports used on the CN4093 is less or equal to 22.
Table 10. CN4093 as an NPV Gateway connected to the Cisco MDS SAN (Figure 8)
Diagram reference | Description | Part number | Quantity |
---|---|---|---|
Flex System FCoE solution | |||
Flex System x240 Compute Node or other supported compute node | Varies | Varies | |
Flex System CN4054 10Gb Virtual Fabric Adapter | 90Y3554 | 1 per compute node | |
Flex System CN4054 Virtual Fabric Adapter Upgrade | 90Y3558 | 1 per VFA | |
Flex System Fabric CN4093 10Gb Converged Scalable Switch | 00D5823 | 2 | |
Flex System Fabric CN4093 Converged Scalable Switch (Upgrade 1)* | 00D5845 | 1 |
per CN4093
| RackSwitch G8264
| Cisco MDS SAN fabric
| Storage systems
DS3000 / DS5000
DS8000
Storwize V3700 / V5000 / V7000 / SAN Volume Controller
XIV
Lenovo provides extensive FCoE testing to deliver network interoperability.
For a full listing of supported FCoE and iSCSI configurations, see the System
Storage Interoperation Center (SSIC) website at:
http://ibm.com/systems/support/storage/ssic
CN4093 with flexible port mapping (4-port network adapter example)
Prior to Networking OS 7.8, compute nodes with 4-port network adapters
required Upgrade 1 or Upgrade 2 for the CN4093 to enable connectivity on all
four adapter ports despite of number of compute nodes and external connections
used. With the introduction of flexible port mapping in Networking OS 7.8, if
the Flex System chassis is not fully populated with the compute nodes that
have four network ports, there might be no need to buy Upgrade 1.
Consider the following scenario. You are planning to install nine x240 compute
nodes with CN4054 adapters or nine high-density x222 compute nodes that will
be connected to two CN4093 switches installed in I/O bays 1 and 2. You are
also planning to use two external 10 GbE ports on each CN4093 for the
connectivity to the upstream network and two Omni Ports on each switch for FC
SAN connectivity. In this scenario, the total number of 10 GbE ports and Omni
Ports needed per one CN4093 is 22. The base switch supplies required 22 port
licenses; therefore, the solution can be implemented without the need to buy
Upgrade 1 or Upgrade 2.
Figure 10 illustrates this scenario.
Diagram reference | Description | Part number | Quantity |
---|---|---|---|
Flex System FCoE solution | |||
Flex System x240 Compute Node or other supported compute node | Varies | Varies | |
Flex System CN4054 10Gb Virtual Fabric Adapter | 90Y3554 | 1 per compute node | |
Flex System CN4054 Virtual Fabric Adapter Upgrade | 90Y3558 | 1 per VFA | |
Flex System Fabric CN4093 10Gb Converged Scalable Switch | 00D5823 | 2 | |
Flex System Fabric CN4093 Converged Scalable Switch (Upgrade 1)* | 00D5845 | 1 |
per CN4093
| RackSwitch G8264
| Cisco MDS SAN fabric
| Storage systems
DS3000 / DS5000
DS8000
Storwize V3700 / V5000 / V7000 / SAN Volume Controller
XIV
Lenovo provides extensive FCoE testing to deliver network interoperability.
For a full listing of supported FCoE and iSCSI configurations, see the System
Storage Interoperation Center (SSIC) website at:
http://ibm.com/systems/support/storage/ssic
CN4093 with flexible port mapping (4-port network adapter example)
Prior to Networking OS 7.8, compute nodes with 4-port network adapters
required Upgrade 1 or Upgrade 2 for the CN4093 to enable connectivity on all
four adapter ports despite of number of compute nodes and external connections
used. With the introduction of flexible port mapping in Networking OS 7.8, if
the Flex System chassis is not fully populated with the compute nodes that
have four network ports, there might be no need to buy Upgrade 1.
Consider the following scenario. You are planning to install nine x240 compute
nodes with CN4054 adapters or nine high-density x222 compute nodes that will
be connected to two CN4093 switches installed in I/O bays 1 and 2. You are
also planning to use two external 10 GbE ports on each CN4093 for the
connectivity to the upstream network and two Omni Ports on each switch for FC
SAN connectivity. In this scenario, the total number of 10 GbE ports and Omni
Ports needed per one CN4093 is 22. The base switch supplies required 22 port
licenses; therefore, the solution can be implemented without the need to buy
Upgrade 1 or Upgrade 2.
Figure 10 illustrates this scenario.
Figure 9. CN4093 with flexible port mapping (4-port network adapter example)
The solution components used in the scenario shown in Figure 10 are listed in
Table 11.
Table 11. CN4093 with 4-port network adapters
Diagram reference | Description | Part number | Quantity |
---|---|---|---|
Flex System x240 Compute Node or other supported compute node | Varies | Up |
to 9 per chassis
| Flex System CN4054R 10Gb Virtual Fabric Adapter| 00Y3306| 1 per compute node
Flex System CN4054 Virtual Fabric Adapter Upgrade| 90Y3558| 1 per VFA
| Flex System Enterprise Chassis with additional power supplies and fan
modules if needed| 8721A1G| 1
| Flex System Fabric CN4093 10Gb Converged Scalable Switch| 00D5823| 2 per
chassis
SFP+ modules and optical cables or SFP+ DAC cables (See Table 3)| Varies| 4 (2
per CN4093)
8Gb SFP+ SW Optical Transceiver| 44X1964| 4 (2 per CN4093)
- Installation Guide
- Application Guide
- Command Reference
These are other useful references:
-
US Announcement Letter for the CN4093
http://ibm.com/common/ssi/cgi- bin/ssialias?infotype=dd&subtype=ca&&htmlfid=897/ENUS112-185 -
Flex System Enterprise Chassis Product Guide
http://lenovopress.com/tips0863 -
Flex System Products and Technology, SG24-8255
http://lenovopress.com/sg248255 -
Flex System Interoperability Guide
http://lenovopress.com/fsig -
Support: FixCentral
http://www.ibm.com/support/fixcentral/
Related product families
Product families related to this document are the following:
- 10 Gb Embedded Connectivity
- Blade Networking Modules
Notices
Lenovo may not offer the products, services, or features discussed in this
document in all countries. Consult your local Lenovo representative for
information on the products and services currently available in your area. Any
reference to a Lenovo product, program, or service is not intended to state or
imply that only that Lenovo product, program, or service may be used. Any
functionally equivalent product, program, or service that does not infringe
any Lenovo intellectual property right may be used instead. However, it is the
user’s responsibility to evaluate and verify the operation of any other
product, program, or service. Lenovo may have patents or pending patent
applications covering subject matter described in this document. The
furnishing of this document does not give you any license to these patents.
You can send license inquiries, in writing, to:
Lenovo (United States), Inc.
8001 Development Drive
Morrisville, NC 27560
U.S.A.
Attention: Lenovo Director of Licensing
LENOVO PROVIDES THIS PUBLICATION ”AS IS” WITHOUT WARRANTY OF ANY KIND, EITHER
EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF
NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Some
jurisdictions do not allow disclaimer of express or implied warranties in
certain transactions, therefore, this statement may not apply to you.
This information could include technical inaccuracies or typographical errors.
Changes are periodically made to the information herein; these changes will be
incorporated in new editions of the publication. Lenovo may make improvements
and/or changes in the product(s) and/or the program(s) described in this
publication at any time without notice.
The products described in this document are not intended for use in
implantation or other life support applications where malfunction may result
in injury or death to persons. The information contained in this document does
not affect or change Lenovo product specifications or warranties. Nothing in
this document shall operate as an express or implied license or indemnity
under the intellectual property rights of Lenovo or third parties. All
information contained in this document was obtained in specific environments
and is presented as an illustration. The result obtained in other operating
environments may vary. Lenovo may use or distribute any of the information you
supply in any way it believes appropriate without incurring any obligation to
you.
Any references in this publication to non-Lenovo Web sites are provided for
convenience only and do not in any manner serve as an endorsement of those Web
sites. The materials at those Web sites are not part of the materials for this
Lenovo product, and use of those Web sites is at your own risk. Any
performance data contained herein was determined in a controlled environment.
Therefore, the result obtained in other operating environments may vary
significantly. Some measurements may have been made on development-level
systems and there is no guarantee that these measurements will be the same on
generally available systems. Furthermore, some measurements may have been
estimated through extrapolation. Actual results may vary. Users of this
document should verify the applicable data for their specific environment.
© Copyright Lenovo 2022. All rights reserved.
This document, TIPS0910, was created or updated on May 7, 2018.
Send us your comments in one of the following ways:
-
Use the online Contact us review form found at:
https://lenovopress.lenovo.com/TIPS0910 -
Send your comments in an e-mail to:
comments@lenovopress.com
Trademarks
Lenovo and the Lenovo logo are trademarks or registered trademarks of Lenovo
in the United States, other countries, or both. A current list of Lenovo
trademarks is available on the Web at
https://www.lenovo.com/us/en/legal/copytrade/.
The following terms are trademarks of Lenovo in the United States, other
countries, or both:
Lenovo®
Flex System
Omni Ports
RackSwitch
ThinkSystem®
VMready®
The following terms are trademarks of other companies:
Intel® is a trademark of Intel Corporation or its subsidiaries.
Other company, product, or service names may be trademarks or service marks of
others.
References
- IBM System Storage Interoperation Center (SSIC)
- Flex System Interoperability Guide > Lenovo Press
- Lenovo Flex System Products and Technology > Lenovo Press
- Flex System Enterprise Chassis Product Guide > Lenovo Press
- IBM Support: Fix Central
- 10 Gb Embedded Connectivity > Lenovo Press
- Blade Networking Modules > Lenovo Press
- Flex System Fabric CN4093 10Gb Converged Scalable Switch Product Guide (withdrawn product) > Lenovo Press
- Copyright and Trademark Information | Lenovo US | Lenovo US
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>