The unit generates light by means of high-power LEDs. The unit was designed for indoor use only.

Attention

  • The unit must be installed by a qualified electrician in accordance with all national and local electrical and construction codes and regulations.
  • The unit was designed for indoor use only.
  • Avoid looking directly into the LED light beam at close range!
  • Do not install the unit near highly inflammable liquids or materials.
  • Do not allow anything to rest on the unit.
  • Do not install the unit near an open flame.
  • Do not install the unit in a dirty, dusty or badly ventilated location.
  • Sufficient air access to the housing of the unit has to be ensured, there must not be any heat or anti-noise insulation within a 0.6m x 0.6m area around the unit (non-IC rated fixture).
  • Immunity of the equipment is designed for electromagnetic environments E1, E2, and E3 according to the standard EN55103-2 ed.2 Electromagnetic compatibility. Product family standard for audio, video, audiovisual, and entertainment lighting control apparatus for professional use. Part 2: Immunity.
  • The product (covers and cables) must not be exposed to a high-frequency electromagnetic field higher than 3V/m.
  • The installation company should check levels of possible interferences above the tested levels
  • E1, E2, and E3 are given by this standard (e.g. transmitters in the surrounding area) before installing the equipment. The emission of the equipment complies with the standard EN55032
  • Electromagnetic compatibility of multimedia equipment – Emission Requirements according to class B.

Always switch off the power supply of the unit before connecting or disconnecting the unit

Installation

  1. Prepare a circular opening in the lower ceiling (1) as shown in the picture below.
  2. Insert the Ambiane AP unit into the opening. Fasten the Ambiane AP by means of two spring fasteners (2) to the opening.
  3. Connect needed cables to the Ambiane AP. Connection blocks (4) are placed on the PCB RB 3727 (3). The PCB is under plastic cover (5) which is fastened by means of two screws (6).
  • The primary power input serves as a standard power (e.g. Power Supply for Ambiane AP).
  • The secondary power input serves for backup power( in case the primary power failed).
  • If both power inputs are under voltage, the primary power has priority and the secondary power is disabled. In case of primary power loss, secondary power is enabled.
  • If the Ambiane AP is supplied via the secondary power, the light intensity can be set by the trimmer (9).
  • The Ambiane AP can be controlled by one of the following methods: DMX 512.
    • DALI
    • 0 – 10V (Ambiane AP PW, Ambiane AP TD only)
  • The Ambiane AP is equipped with two DMX and DALI connection blocks for easy connection to DMX or DALI chain (In/Out method).

DMX connection

PCB Function

  • 0V – Shield
  • D+ Signal (+)
  • D- Signal (-)

0-10V connection

PCB Function

  • 0V 0V
  • D+ +10V

Power connection

PCB Function

  • + Power +
  • – Power –

Recommended diameters of conductors with respect to distance between Ambiane AP and power supply unit (Ambiane Power AP).

Distance/cable length 50 m 100 m
Diameters of conductors 0.5 mm2 1 mm2

DMX and DALI address setting and control

The DIP switch (7), located next to the connection blocks, allows you to run a test light and switch the Ambiane AP to the update mode in case of software update.

  • DIP 10 – if switched to ON=test light (3200K for RGBW and TW version)
  • DIP 11 – selection of fixture control: OFF=DMX 512 or DALI, ON=0-10V
  • DIP 12 – change from OFF to ON position switches the Ambiane AP to the update mode (switching to the update mode is not necessary if the Robe Uploader is used for Ambiane AP update).

DMX control
The DMX start address is the first channel used to receive instructions from the DMX controller. The address may be any channel from 1 to 509. DMX address can be set either by DIP switch or by RDM. DMX address set by RDM overwrites address set by DIP switch and vice versa. The green LED (8) on the PCB signals the way of DMX address setting:

  • LED lights-DMX address is set by means of the DIP switch.
  • LED does not light- DMX address is set by means of RDM.

DIP 11 has to be set in OFF position.

Example of DMX addresses:

DALI control
Addressing of the Ambiane AP is made by means of an external DALI controller. The external DALI controller has to send activating command (8=ON) if you need to start the permanent control of the Ambiane AP (Ambiane AP will not respond to DMX commands) and deactivating command (0=OFF) to stop control of the Ambiane AP. DIP 11 has to be set in the OFF position.

Note:
If DIP 11=OFF (Ambiane AP is controlled by DMX or DALI), the first coming command switches the Am-Diane AP to the corresponding operation mode (DMX operation by a DMX command, DALI operation by a DALI command). For E.g. the Ambiane AP stays in a DALI operation and the coming DMX command switches the Ambiane AP to a DMX operation. The next command is a DALI command and switches the Ambiane AP to the DALI operation etc. If you need the permanent DALI operation, you have to send a DALI command 8 to the Ambiane AP.

0-10V control
DIP 11 has to be set in the ON position. The 0-10V operation has priority to DALI commands. The option is applicable for Ambiane AP PW and Ambiane AP TD only.

RDM

This Ambiane AP supports RDM operation. RDM (Remote Device Management) is a bi-directional communication protocol for use in DM X512 control systems, it is the new open standard for DMX512 device configuration and status monitoring. RDM allows you to set some options as DMX address, select DMX mode, and readout the software version of the Ambiane AP etc.

Via RDM you can also set the behavior of the fixture in case of loss of DMX signal. For this purpose serve the following two options:

DMX hold

  • Value On (0) – the fixture keeps last received DMX values in case of DMX loss (default setting).
  • Value Off (1) – it activates the option ” DMX lost”. To set the option “DMX hold” to Off, you have to send a value 1 via RDM.

DMX lost
The option is active only if the option “DMX hold” is set Off.

  • Value On (0) – the fixture lights at max. light output in case of DMX loss (default setting).
  • Value Off (1) – The light output of the fixture is closed in case of DMX loss. To set the option “DMX lost” to Off, you have to send a value 1 at RDM.

RDM model ID for the Ambiane AP is 0x0114.

Parameter ID Discovery command SET command GET command
DISC_UNIQUE_BRANCH *****  
DISC_MUTE *****  
DISC_UN_MUTE *****  
DEVICE_INFO     *****
SUPPORTED_PARAMETERS     *****
SOFTWARE_VERSION_LABEL     *****
DMX_START_ADDRESS   ***** *****
IDENTIFY_DEVICE   ***** *****
DEVICE_MODEL_DESCRIPTION     *****
MANUFACTURER_LABEL     *****
DEVICE_LABEL   ***** *****
SENSOR_DEFINITION     *****
SENSOR_VALUE     *****
RESET_DEVICE   *****
DMX_PERSONALITY   ***** *****
DMX_PERSONALITY_DESCRIPTION     *****
SENSOR_VALUE   ***** *****
SENSOR DEFINITION     *****

Anti-glare ring installation

Insert the anti-glare ring (1) into the Ambiane AP until three locks (2) snap into slots (3).

Adapter ring installation

  1. Remove both spring fasteners (2) by unscrewing the four screws M4x10 (1).
  2. Slide the adapter ring (4) onto the housing of the Ambiane AP. Screw the new fasteners (3) on the housing. Use original screws M4x10 (1).

DMX protocols

Ambiane AP RGBW , Ambiane AP RGBA Version 1.2

Mode 1

Channel

| Mode 2

Channe

| Mode 3

Channe

| Mode 4

Channe

| Mode 5

Channe

| Value| Function| Type of control
---|---|---|---|---|---|---|---
1| 1| 1| –| 1|

0-255

| Red

Red LEDs saturation control 0% –>100%

|

proportional

–| –| 2| –| –|

0-255

| Red Fine

Red LEDs saturation control from min. –>max.

|

proportional

2| 2| 3| –| 2|

0-255

| Green

Green LEDs saturation control 0% –>100%

|

proportional

–| –| 4| –| –|

0-255

| Green Fine

Green LEDs saturation control from min. –>max.

|

proportional

3| 3| 5| –| 3|

0-255

| Blue

Blue LEDs saturation control 0% –>100%

|

proportional

–| –| 6| –| –|

0-255

| Blue Fine

Blue LEDs saturation control from min. –>max.

|

proportional

4| –| 7| –| 4|

0-255

| White/Amber

White (Amber) LEDs saturation control 0% –>100%

|

proportional

–| –| 8| –| –|

0-255

| White/Amber Fine

White(Amber) LEDs saturation control min. –>max.

|

proportional

|

|

9

|

1

|

|

0

1-127

128

129-255

| Green White Fine

Uncorrected white

Minus green –> uncorrected white Uncorrected white (128=default) Uncorrected white –> plus green

|

step proportional step proportional

|

|

10

|

2

|

|

0

1-10

11-20

21-255

| Colour temperature correction (CTC)

No function (default) Tungsten dimming 3200K Tungsten dimming (3200K)

Colour temperature changing 2700K-6500K (21=2700K, 64-3200K, 128=4200K, 192-5600K,

255=6500K)

|

step step step

proportional

–| –| 11| 3| 5|

0-255

| Dimmer

Light intensity coarse 0% –>100%

|

proportional

–| –| 12| –| 6|

0-255

| Dimmer Fine

Light intensity from min. –>max.

|

proportional

Ambiane AP PW, Ambiane AP TD
Version 1.1

Mode 1

Channel

| Mode 2

Channel

| Value| Function| Type of control
---|---|---|---|---
1| 1|

0-255

| Dimmer

Light intensity coarse 0% –>100%

|

proportional

–| 2|

0-255

| Dimmer Fine

Light intensity from min. –>max.

|

proportional

Ambiane AP TW
Version 1.3

Mode 1

Channel

| Mode 2

Channel

| Mode 2

Channel

| Mode 2

Channel

| Value| Function| Type of control
---|---|---|---|---|---|---
1| –| 1| –|

0-255

| White colour selection

White from 2700K–>4000K

|

proportional

–| 1| –| 1|

0-255

| Warm White

Warm White LEDs saturation control 0% –>100%

|

proportional

–| 2| –| 2|

0-255

| Cool White

Cool White LEDs saturation control 0% –>100%

|

proportional

2| 3| 2| 3|

0-255

| Dimmer coarse

Light intensity coarse 0% –>100%

|

proportional

–| –| 3| 4|

0-255

| Dimmer Fine

Light intensity from min. –>max.

|

proportional

Technical Specifications

  • Input voltage: 48V DC
  • Protection class: CE: (Class III )
    • ETL: Class 2 or LVLE
  • Max. power consumption: 40W
  • Beam angle: 67°, 80° with anti-glare ring
    • Ambiane AP PW 2700K, 4000K
    • Ambiane AP TW 2700K – 4000K
    • Ambiane AP TD 3200K
  • Control:
    • Ambiane AP RGBW, Ambiane AP TW DMX, DALI, RDM compatible
    • Ambiane AP PW, Ambiane AP TD DMX, DALI, 0-10V, RDM compatible
  • DMX channels:
    • Ambiane AP RGBW 4 (Mode 1), 3 (Mode 2), 12 (Mode 3), 3 (Mode 4), 6 (Mode 5)
    • Ambiane AP PW, Ambiane TD 1 (Mode 1), 2 (Mode 2)
    • Ambiane AP TW 2 (Mode 1), 3 (Mode 2)
  • Typical Lumen Maintenance: 70%@ 50,000 hours
  • Led life expectancy: minimum 50,000 hours
  • Operating ambient temp. range: -20°C/+45°C (-4F/+113F)
  • Operating temperature: 75°C @ Ambient +35°C (167°F @ Ambient +95°F)
  • Total heat dissipation: 136 BTU/h (calculated)
  • Cooling: convection
  • Housing: Aluminum
  • Weight: 1.9 kg| (4.19 lbs)
  • Installation method: via two spring fasteners
  • IC rating: non-IC rated
  • Power/DMX/DALI connection: terminal blocks
  • Protection factor: IP 20 (without diffuser glass), IP20/IP54 (with Diffuser Glass)

Ambiane AP without Diffuser Glass
Ambiane AP with Diffuser Glass

Included items

  • 1 x Ambiane AP
  • 1x Anti-Glare Ring (P/N 10980386)
  • 1 x Set of cable connectors
  • 1 x User manual

Optional Accessories

  • Ambiane Power AP (P/N 10063994)
  • Anti-Glare Ring (P/N 10980386)
  • Adapter Ring (235-255mm ) (P/N 10980388)

Dimensions

mm [inch]

Maintenance

Keep the Ambiane AP clean, especially light source and the ribbed housing.

Software update
Software updates of the fixture can be done by means of the ROBE Uploader. It is a software for automatized software updates of Robe and Anolis fixtures. It takes advantage of RDM support.

The fixtures have to be connected in a daisy chain (max. 32 fixtures) and via the Robe Universal Interface/Robe Universal Interface WTX and a USB cable connected to the control PC with the Robe Uploader running. The control PC should be connected to the Internet.

Note:
If you do the software update by means of the Robe Uploader, switching fixtures to the update mode (and from the update mode) is made automatically, without the need to switch the DIP 12 to the ON position (update mode).

The Robe Uploader software cannot be used if fixtures are connected by means of a DALI connection.

The Robe Uploader software and user manual are available at: https://www.robe.cz/robe-uploader/.

Version 1.9
November 30, 2021

Specifications are subject to change without notice.
Made in CZECH REPUBLIC by ROBE LIGHTING s.r.o. Palackeho 416/20 CZ 75701 Valasske Mezirici.

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals