PRODUCT SPECIFICATIONS

GENERAL SPECIFICATIONS

Fuse| 1 OOmAl250V fast blow
Power supp ly| 9Vbattery
Operating Environment| 32•F to 104°F (0°C to 40°C) at <80%

rel ative humidity

Storage Environment| 14°F to 140°F (-10″C to 60°C)at <80%

rel ative humidity

WireVerification Distance| 10,000ftI 3000m (26 AWG min.)
Dimensions| Approx.3.8×2.4×1.3in (96x60x34mm)
Net Weight| Approx.0.21b(94g)

PACKAGE CONTENTS

PART DESCRIPTION

1| Power on indicator-Red work LED (flashes when battery is low)
2| ON/OFF button
3| Red LED confo uity indicator (- Polarity)
4| GreenLED continuity indicator (+ Polarity)
5| Remote holder (side mounted plastic piece)
6| Red andblack tester leads w/alligator
7| Remoteprobecontinuity indicator (red/green bi-color LED)
8| Red andblack remote leads wlalligator

SAFETY INFORMATION

warnings

  • Please read and understand this entire manual before using this product
  • Do not connect the tester to a live circuit. Connecting the tester to voltage presents a shock hazard and may damage the tester.
  • Improper use of this tester can cause damage, shock, injury or death.
  • Read and understand this user’s guide before use.
  • Do not use the tester in a wet or damp environment or during electrical stoms
  • Do not use the tester near explosive gases, dust or vapor.
  • Replace the battery ass oon s the low battery warning appears.
  • Inspect the condition of the test leads and the tester itself for any damage before use.

OPERATION INSTRUCTIONS

WARNING: Do not connect to live wires. Use only on unpowered circuits. Momentarily press the ON/OFF O button, the tester will beep once and the red work LED will glow to indicate the tester is on and ready for use. If the red work LED is flashing, it means the battery is almost exhausted, replace the battery to restore operation. If the battery voltage is too low for reliable operation, the tester will beep three times and the red work LED will turn off indicating the tester is not operational.

Momentarily press the ON/OFF button again, the tester will beep twice and the red work LED will turn off to indicate the tester is not operational.
NOTE: To extend battery life, the tester will automatically turn off after approximately 30 minutes of inactivity. When powering down, the beeper will beep twice and all LED will turn off.  Refer to the Examples shown below for checking continuity and polarity.
Example 1: Simple Continuity Test without Remote.

Use the chart below to interpret testing results.

RESISTANCE RANGE    GREEN LEO REDLEO           FLASHING/

BEEPING RATE

•    •


0 to approx . 1.0kO| •|  | Very Fast
Approx. 1.0 kO to 3.9 kO|  | 0

| Slow
Approx. 3.9 kO to ·J0.1k0| 0|  | Fast
Above approx. 10.1kO| 0| 0| No Flashing or Beepinq

  • Flashing or Glowing
  • NOT Glowing

Example 2: Continuity Test and Polanity on a Cable with Remote.KOBALT-CT-30
-Continuity-Test-with-Remote-FIG3

Example 3: Tracing Multiple Cables with Remote.

NOTE: If there is a short in the cable between the tester and the remote, the green and red LEDs on the tester will flash rapidly and the remote LED will not glow. Continuity Test with Remote, the Positive (+) polarity test cables resistance range approx. 0-1.2k2, and the Reverse (-) polarity test cables resistance range approx. 0-3.2k0. If the cable resistance out of the test range, some abnomal situation will occur, as shown in the following chart.

….|  | •

Red

LED

---|---|---
Conne ction method|  | Green LED

| Red LED| Green LED

Positive(t) polarity connect

| 0-approx. 1.2kO|  | 0

| •| 0
Approx. 1.2k0 to 3.9kO| 0|  |  | 0
Above approx. 3.9kO| 0| 0

|  | 0

R everse ( -) polarity connect| 0 -approx. 3.2kO| 0|  | 0| •
Above approx. 3.2kO| 0| 0| 0|

  • Flashing or Glowing
  • NOT Glowing
  • Weak Glowing

Battery Replacement

  • Loosen the one screw.
  • Remove the battery cover.
  • Replace one 9 volt battery.
  • Install the battery cover and tighten the screw

Fuse Replacement
The fuse will blow if the tester is connected to a live circuit. If the cable voltage does not exceed 100V, replace the fuse with the same specification, usually can resume normal use. Higher voltage will cause permanent damage. Do not use the tester if there are any signs of damage.

Follow the steps below to replace the fuse.

  • Remove battery, and loosen the 4 screws on back cover.
  • Open the back cover carefully.
  • Gently remove fuse and install certified fuse (100mA/250V fast blow, 5x20mm) into the holder. Do not substitute.
  • Install the back cover and battery cover and tighten the Screws.

NOTE: Do not operate the tester until the back cover is installed and securely fastened.

CARE AND MAINTENANCE

  • Keep the meter dry. if it gets wet, wipe it off.
  • Keep the meter clean. Wipe the dirt with a soft cloth dampened with water. Do not use chemicals, cleaning solvents, or detergents.
  • Use and store the meter in normal temperatures. lemperature extremes can shorten the life of the electronic parts and distort or melt plastic parts
  • Handle the meter gently and carefully. Dropping it can damage the electronic parts or the case.
  • Use only fresh battery of the recommended size and type. Battery are to be inserted with the correct polarity. Remove old or weak battery so they do not leak and damage the unit
  • Do not mıx old and new battery. Do not mix diferent types of battery such as alkaline, carbon-zinc, or rechargeable battery. Non-rechargeable battery are not to be recharged.
  • If the meter is to be stored for a long period of time, the battery should be removed to prevent damage to the unit.

TROUBLESHOOTING

PROBLEM POSSIBLE CAUSE CORRECTIVE ACTION
The tester cannot turn on 1. No battery installed

2. Battery is weak

| 1. Install battery

2. Reolace batterv

The tester’s red and black crocodiel  clips are short- circuited,but there is no short-circuit result on the tester.|

The fuse blew

|

Repl ace fuse

WARRANTY

Three-year warranty. Incidental or consequential damages are excluded from this warranty.

PRODUCT COMPLIANCE

Users of this product are cautioned not to make modifications or changes. Doing so may void the compliance of this product with applicable laws and regulatory requirements and may result in the loss of the users authority to operate the equipment.

FCC COMPLIANCE

This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:

  1. This device may not cause harmful interference, and
  2. this device must accept any interference received, including interference that may cause undesired operation.”

Lowe’s Home Centers LLC
1000 Lowe’s Blvd.
Mooresville, NC 28117
1-888-3KOBALT (1-888-356-2258)

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and the receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected to.
  • Consuit the dealer or an experienced radio/TV technician for help.

“CAUTION: Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment”

KOBALT and logo design are trademarks or registered trademarks of LF, LLC. All rights reserved.

Questions, problems, missing parts? Before retuming to your retailer, call our customer service department at 1-888-3KOBALT (1-888-356-2258). 8 a.m. -8 p.m., EST, Monday Sunday. You may also contact us anytime at www.lowes.com

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals