Whynter ECO-FRIENDLY 12,000 BTU Portable Air Conditioner ARC-12S Instruction Manual
- June 7, 2024
- Whynter
Table of Contents
- Whynter ECO-FRIENDLY 12,000 BTU Portable Air Conditioner ARC-12S
- SAFETY PRECAUTIONS
- OPERATING CONDITION
- OPERATING YOUR AIR CONDITIONER
- OPERATION INSTRUCTIONS
- CARE AND MAINTENANCE
- TROUBLESHOOTING
- ONE YEAR LIMITED WARRANTY & THREE YEAR WARRANTY ON COMPRESSOR
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Whynter ECO-FRIENDLY 12,000 BTU Portable Air Conditioner ARC-12S
Thank you for choosing the Whynter portable air conditioner. Please follow the instructions provided in this user guide to obtain the very best performance from your portable air conditioner and take full advantage of the many features your portable air conditioner offers you. We trust that your Whynter air conditioner will provide the performance and reliability that we stand for. Please keep this user manual in a safe place for future reference.
DISPOSAL
This symbol on the product or its packaging indicates that the appliance cannot be treated as normal domestic trash, but must be handed in at a collection point for recycling electric and electronic appliances. Your contribution to the correct disposal of this product protects the environment. Further information about the recycling of this product can be obtained from your local municipal authority.
Your safety and the safety of others are very important to us. To reduce the risk of fire, electrical shock or injury when using your appliance, follow these basic precautions.
SAFETY PRECAUTIONS
Before the portable air conditioner is used, it must be properly positioned and installed as detailed in this manual.
DANGER
- Do not under any circumstances cut or remove the third (ground) prong from the power cord.
- Make sure this unit is connected to a correctly grounded power supply outlet. Do not use anextension cord or power strip.
- The power cord is UL listed. It has a built-in L.C.D.I. (leakage, current, detection, interruption) circuit breaker for added safety. If the power supply is interrupted, press the reset button to reconnect the unit to power source.
- It is recommended to use a separate circuit that its size should be 15 Amps for the air conditioner.
- Do not use an excessively wet cloth, industrial solvents, oil-based products to clean this portable air conditioner.
- To avoid the risk of shock, the product should never be used in bathrooms, shower rooms, or in any other steamy or wet areas.
- Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliances.
- Do not repair, disassemble and/or modify the unit by yourself.
- Always turn off the portable air conditioner when cleaning the air filter, and transporting.
- Do not turn this unit on and off by plugging and unplugging. Always use the ON/OFF switch.
WARNING
- Transport the unit in an upright position only, or leave it in an upright position for a minimum of 4 hours before first use.
- Ensure curtains or other objects are not obstructing the air inlet filters.
- Do not bend or crush the exhaust hose while in use.
- Always allow at least 20″ of clearance around the unit for ventilation. Do not use this unit inside closets, cabinets and/or cramped spaces between furniture.
- This unit is optimized to operate in an ambient temperature of 64 °F – 95°F.
- This unit must be installed in an area protected from the elements, such as wind, rain, water spray or drips.
- The unit should not be placed next to ovens, grills or other heat sources.
- Always place the unit on even and hard and level surface.
- Do not sit or place objects on the unit.
- Do not allow children to climb, stand or hang on the unit. The air conditioner could tip over and get damaged and/or seriously injure somebody.
- Keep fingers out of the air intakes and air outlets.
- The unit is an electrical appliance. To avoid injury from electrical shock do not operate it with wet hands, while standing on a wet surface or while standing in water. Do not use it in outdoors or in wet conditions.
- When positioning or moving the unit, ensure it is not turned upside down or greater than 45° or more off level.
- This unit is designed for household, non-commercial use only. Any other use will void the warranty.
- Do not plug into the power outlet before set up is completed.
- Do not operate this unit without the air filter(s).
- Do not use harsh chemicals to clean the filter(s). Dry thoroughly before inserting the filter(s) into the unit.
- Do not add extra length to the exhaust hose by more than a total length of 9′. This will reduce the cooling efficiency of the portable air conditioner.
- At the end of each season, all water must be drained from the unit and filter(s) must be cleaned before storage.
THE MANUFACTURER DISCLAIMS ANY RESPONSIBILITY IF THE ABOVE INSTRUCTIONS ARE NOT FOLLOWED.
OPERATING CONDITION
MODE | ROOM TEMPERATURE |
---|---|
COOL | Higher than 64°F |
DRY | Higher than 60°F |
Your portable air conditioner is supplied with a Leakage-Current Detection and Interruption (LCDI) plug. This plug reduces the risk of fire due to arcing faults in the power supply cord. Please follow the instructions below to ensure that LCDI plug works properly.
- Plug the power cord to a grounded wall outlet. Do not plug to a power strip or extension cord.
- Press the TEST button on the plug. This should trip the plug and cut the power to the air conditioner. If the plug does not trip and the unit comes on, please contact technical support.
- Press the RESET button to start the air conditioner.
- Do NOT use the TEST and RESET buttons to turn the air conditioner on and off.
IDENTIFICATION OF ACCESSORIES ****
The fixture piece may come attached to the cover piece. To remove, twist the
cover piece to allow the tab from the fixture to disengage from the cover, and
twist the cover to remove from the fixture.
Note : Please visit whynter.com for optional accessories information.
IDENTIFICATION OF PARTS
Front
-
Control panel
-
Air vent
-
Air deflector (Left – Right)
-
Caster wheel
Rear -
Handle
-
Air filter
-
Evaporator air intake
-
Air exhaust
-
Condenser air intake
-
Power cord
-
Drain plug and cover
-
Upper drain plug
OPERATING YOUR AIR CONDITIONER
Before you begin, thoroughly familiarize yourself with the control panel, remote control and all of the functions. Follow the symbol for the desired function. The unit can be controlled by the unit control panel alone or with the remote control.
CONTROL PANEL
Power Control @
Turns the unit on and off.
Warning Light
| Fan Speed Control @
Controls the 3 fan speeds: High, Medium & Low.
NOTE: Unit does not need to be vented in Fan mode.
---|---
Condensation water may accumulate in the unit. If the internal reservoir becomes full, the warning light and the STOPlight will come on and the unit will
stop until the water is drained.
| Timer0
Turns the timer function on and off.
Timer Temperature Set Control
Mode Control @
Controls the 3 function modes: COOL,
DEHUMIDIFYING and FAN ONLY.
| I
Adjusts set thermostat temperature and timer. The display temperature is the set temperature. NOTE: This unit is capable of displaying set temperature in Fahrenheit or in Celsius. To convert from one to the other, press and hold the Up and
Down buttons for 3 seconds.
INSTALLATION INSTRUCTIONS
Location
The air conditioner should be placed on a hard and level surface strong enough
to support its weight. The unit is equipped with caster wheels for
portability. It should only be rolled on smooth, flat surfaces. Use caution
when rolling on carpet surfaces. Do not attempt to roll the unit over objects.
The air inlet and outlet should be free of any obstructions and be placed with
at least 20″ of clearance for efficient air-conditioning and circulation.
Exhaust hose Installation When using the air conditioner, the hot air from the exhaust hose must be exhausted out of the room to complete the air exchange of the condenser. When the unit is operating in dehumidifying or fan- only mode, installation of the exhaust hose is optional.
- Fully expand each end of the exhaust hose about 6″.
- Install the hose connectors onto the exhaust hose by threading counterclockwise.
- Align the tab cut-outs on one of the hose connectors to the tabs on the air exhaust at the rear of the unit and snap in place.
Only extend the hose to the necessary length, keeping it as short and as straight as possible. We do not recommend extending the hose more than 9′ long. If you are interested in purchasing an additional 5′ exhaust hose, please contact support@whynter.com for retail sales information or visit whynter.com for a list of optional accessories.
Window kit Installation
The window kit has been designed to fit most standard vertical and horizontal windows. However, it may be necessary to modify the installation procedures to accommodate your window.
- If your window opening is smaller than the minimum length of the window slider kit, the window slider kit can be cut to fit the window opening. Never cut into the exhaust hose cut-out on the window slider kit.
- If your window opening is larger than the maximum length of the window slider kit, additional material will be needed to cover the open space such as, Plexiglas, PVC plastic, ply wood, etc. Alternately, an additional window slider kit can be purchased to be used in combination with the included kit.
- When using the window slider kit on a window or sliding door, additional security measures may be needed.
- Open the window approximately 5″.
- Adjust the length of the window slider to the same length and width of the opening of the window. Cut the window slider if necessary to fit the length of your window.
- Insert the fixture through the back grooved side of the window slider hose-cutout, aligning the screw holes on the fixture with the screw holes on the unit. Place the screws in the holes from the front of the window slider kit and tighten. (Fig. 1)
- Adjust the slider kit to fit your window. The slider kit comes with screws installed on the main window piece. The long and short extension pieces can be adjusted to fit your window, and the screws can be tightened to keep the extension pieces from sliding. Additional hole scan be drilled in the window kit to allow for a further range of adjustment.
- Fit the window slider kit into the window opening and close the window to secure the window slider kit. For long term installation, you may screw the window kit into your window frame.
- Move the air conditioner close to the window, extend the hose to the necessary length, keeping it as short and as straight as possible and attach the other end of the hose to the window slider kit.
- Align the tab cut-outs of the hose connector to the tabs on the fixture and snap the hose connector to the window slider kit.
AIR FILTERS INSTALLATION
Your Whynter portable air conditioner is equipped with a washable Pre-Filter
and an Activated Carbon Filter. The washable Pre-Filter removes large
particles such as dust, pet hair and dander. The Activated Carbon Filter which
is designed to remove smoke and other odors. It is recommended you replace the
Activated Carbon Filter every 2-3 months or as needed. Follow the steps below
to install the filters.
WARNING : NEVER OPERATE THE AIR CONDITIONER WITHOUT THE PRE-FILTER
- Pull up the pre-filter frame
- Remove the Pre-Filter from the filter frame.
- Place the Activated Carbon Filter on the Pre-Filter.
- Reattached the filter frame.
- Insert the assembled filter frame into the unit.
OPERATION INSTRUCTIONS
- BEFORE USING YOUR PORTABLE AIR CONDITIONER
- Remove the exterior and interior packaging
- Before connecting the appliance to a power source and operating, let the unit stand upright for a minimum of 4 hours. This will reduce the possibility of a malfunction in the cooling system from handling during transportation.
SWITCHING ON/OFF THE AIR CONDITIONER
The unit can be switched ON or OFF by pressing the Power button on the control
panel or the Power button on the remote control.
COOLING MODE
-
In this mode, the air conditioner cools and dehumidifies the room. To activate the cooling function, press the Mode Control button until the GREEN indicator illuminates. When cooling mode is set, the compressor will start in approximately 3 minutes.
NOTE : In cooling mode, hot air is exhausted from the outdoor exhaust port and the exhaust hose must be connected to exhaust out the hot air. -
The temperature setting range is 61 ° F to 89°F. To set the temperature, press the+ orbuttons. The air conditioner has a 5°F temperature cushion; if the set temperature is within 5°F of the ambient temperature, the unit runs in fan only mode. This saves energy and prolongs the life of the compressor. Once the set temperature is achieved, the compressor will turn off and the fan runs continuously to circulate the air within the room.
-
To set the fan speed, press the Fan Speed button. In cooling mode, the difference in noise level between the 3 fan speeds is not very noticeable when the compressor is on. Try setting the unit to Fan only mode, you should be able to hear the difference between high and low fan speed settings.
DEHUMIDIFYING MODE
- In this mode, the air conditioner dehumidifies the room, the compressor will activate intermittently depending on the ambient temperature and the fan speed is set to Low. To activate dehumidifying mode, press the Mode Control button until the PURPLE indicator illuminates. When switching between functions, there will be an approximate 3 minute transition time.
- In dehumidifying mode, the exhaust hose does not need to be vented. If the exhaust hose is vented, the room will be cooled as it dehumidifies. To prevent cooling, remove the exhaust hose from the window kit and allow the warm air from the rear to be re-circulated into the room. If room temperature is higher than 77° F, the fan speed can be adjusted. If room temperature is lower than 77°F, the fan speed is set at Low.
Note: When using dehumidifying mode, venting the exhaust hose to the outside is not required. If vented, the warm air is exhausted to the outside and cooling within the room may occur. Additionally, if the exhaust hose is not vented, the unit may require more frequent draining. The air conditioner does not have a humidistat in which a specific humidity level can be set.
FAN ONLY MODE
- In this mode, only the fan of the air conditioner runs and circulates the air within the room. To activate fan only mode, press the Mode Control button until the YELLOW indicator illuminates. In this mode, the temperature cannot be set. Subsequently, set the desired fan speed by pressing the Fan Speed button.
- Note : When using fan only mode, venting the exhaust hose to the outside is not required.
COMPRESSOR LOCK OUT
This portable air conditioner is optimized to operate in an ambient temperature of 64 °F – 90°F. The compressor circuit has an automatic 3 minute time delayed start if the unit is turned off and on quickly. This prevents over-heating of the compressor and possible circuit breaker tripping.
TIMER (DELAYED SWITCH ON/ OFF) FUNCTION
This function mode enables a delayed switch ON or delayed switch OFF of the air conditioner. The time (hours) delay can be set, enabled and disabled. The timer is adjustable between 1-24 hours.
SETTING SWITCH OFF TIMER
With the air conditioner operating in any function mode, press the Timer Control button. Then set the desired time delay OFF hours by pressing the+ or – buttons. When the delay time set has elapsed, the air conditioner switches off.
SETTING DELAYED SWITCH ON TIMER
With the air conditioner is off, press the Timer Control button. Then set the desired time delay ON hours by pressing the+ or – buttons. When the delay time set has elapsed, the air conditioner switches on.
AUTO RESTART
In the event of a power outage, the air conditioner restarts at the previously
set function mode and settings when power is restored.
NOISE LEVEL
Portable air conditioners may make sounds that are not familiar to you. The sounds listed below are normal. Noise reflecting off hard surfaces such as a floor or wall can make the sounds seem louder than they actually are.
- The compressor may make a pulsating or high-pitched sound.
- Water running from the evaporator to the water tank may make a splashing sound.
- Refrigerant flowing may make a gurgling sound.
- Fan sound may come from front and back air vents.
WATER DRAINAGE
During the process of cooling, some water will be extracted from the air into
the unit. Most of this water is used to cool and exhausted to the outside. If
the unit is operated in high humidity or low temperature environment, water
will collect in the reservoir inside the unit. If the reservoir is full,
the compressor will stop. To continue the cooling function, please drain the
water. The air conditioner has the capacity to dehumidify up to 81 pints per
day. The patented self evaporating function of the unit fully exhausts all
condensation automatically in most environments
when humidity is less than 70%. Areas with more than 70% humidity, the self-
evaporating function can still exhaust about 98% of the moisture and the
remaining 2% of moisture will be collected in the water tank of the air
conditioner. When there is excess water condensation inside the unit, the air
conditioner stops running and the RED Stop light illuminates. The Stop light
indicates that the water condensation needs to be drained manually:
Manual Drainage
- Turn off the unit.
- Carefully roll the unit to a drain location or position a flat container, dish or optional drain bucket accessory (sold separately) under the drain area of the lower drain port.
- Remove the drain cover and rubber plug and the condensed water will drain out automatically.
- Once all the condensed water is drained, replace the drain rubber plug and cover into the drain firmly.
Continuous Gravity Drainage Option
This option is recommended if uninterrupted operation is desired.
- Remove the drain plug cover and rubber plug from the upper drain port.
- Install the drain hose (sold separately) through the drain cover.
- Thread the drain cover onto the upper drain port.
- Place the open end of the drain hose downward to an area appropriate for draining.
WARNING : The hose must be directed downward from the upper drain port to allow the condensed water to flow with gravity.
Note : Please contact support@whynter.com for retail sales information or visit whynter.com for a list of optional accessories.
REMOTE CONTROL
The portable air conditioner can be switched on by the remote control.
NOTE :
- Other appliances in the same room controlled by a remote control (TV, radio, stereo, etc.), may cause interferences.
- Electronic and fluorescent lamps may interfere with the signal transmissions between the remote control and the air conditioner.
- Remove the batteries if the remote control is not used for long periods.
CARE AND MAINTENANCE
IMPORTANT:
- Switch off the air conditioner and disconnect the plug from the power outlet
- Drain al collected condensation from the upper and lower drain ports.
- Only transport the air conditioner in an upright position.
CLEANING THE PRE-FILTER
This unit has two air filters; a washable pre-filter and an activated carbon filter. To ensure the air intake is filtered properly and to assure that your air conditioner runs efficiently, it is recommended that the pre-filter is washed at least once every two weeks depending on use.
- Switch off the air conditioner.
- Pull the pre-filter frame from the unit.
- Remove the activated carbon filter from the pre-filter.
- Use a vacuum cleaner or tap lightly to remove loose dust and dirt from the pre-filter.
- Rinse the pre-filter thoroughly under warm running water (no hotter than 100° F.)
- Dry thoroughly before re-inserting the filters.
NOTE : The activated carbon filter is not washable. It is an optional filter and should be replaced every 2-3 months or as needed if used. Please contact support@whynter.com for retail sales information or visit whynter.com for a list of optional accessories.
WARNING! Never operate the air conditioner without the pre-filter in place
CLEANING THE AIR CONDITIONER
- Always switch off the air conditioner and disconnect the plug from the power supply outlet before cleaning the air conditioner.
- Use a soft damp cloth to wipe the body of the unit.
- Never use harsh chemicals, oil-based products, detergents, chemically treated cloths or other cleaning solutions. These could possibly damage the body of the air conditioner.
END OF SEASON STORAGE
This portable air conditioner comes with one end of season storage cover. We
highly recommend that storage cover bag is utilized when the unit is not going
to be used for a period of time.
WARNING : To avoid danger of suffocation, keep this bag away from babies
and children.
- Switch off the air conditioner and disconnect the power plug from the power supply outlet before cleaning the air conditioner.
- Clean the pre-filter.
- Drain the condensed water completely.
- On a warm day, set the unit to Fan only mode for half a day to dry the unit internally.
- Gather the power cord and bundle it.
- Remove the batteries from the remote.
- If leaving the window kit in place, disconnect the exhaust hose from the window slider kit and place the included cover on the fixture. Otherwise, remove the window kit from the window opening. To remove the hose connector from the fixture on the window kit, slightly turn, push and gently pull the connector to release.
- Place the storage cover over the air conditioner.
Note : Depending on use, it is recommended that the air conditioner be cleaned internally annually. Please contact Whynter at support@whynter.com for internal maintenance cleaning instructions.
Tips:
-
Keep the exhaust hose as short and straight as possible The exhaust hose removes heat from the room. It should remain as short and straight as possible without sharp bends or twists to maximize efficiency. If the exhaust hose must be extended, do not exceed 9′.
-
Turn the air conditioner on early Turning the air conditioner on early instead of waiting until the hottest point of the day will allow the unit to be more effective. The air conditioner will not have to work as hard to cool the room down and maintain the set temperature.
-
Reduce heat sources
Direct sunlight, televisions, computers and other heat generating appliances work against the air conditioner by introducing heat into the space.- Close window curtains and blinds to keep direct sunlight out
- Close doors and windows
- Keep ovens and stoves off
- Turn off unused lights
- Add weather stripping around windows and doors
-
Keep the air filter clean
Regular cleaning will help keep your air conditioner working properly. Dusty filters and vents greatly reduce the airflow and efficiency of the unit.- Clean the washable pre-filter regularly
- Replace the activated carbon filter every 2-3 weeks depending on use
- Vacuum any accumulated dust from around all vents.
TECHNICAL DATA
Model | ARC-12S |
---|---|
Cooling capacity | 12,000 BTU |
Power supply | 115v/ 60Hz |
Maximum power input | 1000 Watts |
Maximum input | 9.2 Amps |
Dehumidifying capacity | 91 Pts / Day |
Thermostat | 61° F to 89° F |
Refrigerant | R-410A |
Air flow (max.) | 320 m 3 / Hour |
Fan speeds | 3 (H, M, L) |
Unit Dimensions | 17″ W x 15.5″ D x 31″ H |
Unit Weight | 62Ibs |
Exhaust Hose | 5.9″ diameter |
Hose Connectors | 5.9″ diameter with 5.0″ diameter reducer |
Fixture and Window Kit | 5.0″ diameter |
Window Kit | 6.5″ W x 20″ (min)/ 46″ (max) L |
TROUBLESHOOTING
Problem | Possible Causes | Solutions |
---|---|---|
The portable air conditioner does not turn on | • Power failure/ outage. |
• The automatic switch, line fuse, or breaker has been tripped.
• The power supply voltage is too low.
• The power cord is damaged.
• The L.C.0.1. power plug for the unit is tripped.
• The internal water reservoir is full.
• Possible loose connection
| • Restore the power supply.
• Flip the switch/ change the fuse/ turn the breaker back on. Also note that you may have too many appliances drawing power on one circuit, you may need to move the other appliances to another circuit.
• Move the unit onto another circuit with the correct voltage.
• Contact Whynter Service Department. Only authorized personnel should replace damaged power cord or power plug.
• Press the Reset button on the L.C.D.I. power plug.
• Drain water from the air conditioner.
• Contact Whynter Service Department
The unit turns on but the compressor does not turn on (the fan runs but the unit is not cooling)| • The room temperature is outside of the operational tolerances of the unit.
• The Cooling mode is not on.
• The compressor has not turned on yet because of its time delay.
• The set temperature is too high.
• The internal water reservoir is full.
| • This unit is designed to work in ambient temperatures of 64° F to 95°F.
• Press the MODE button until the COOL light is shown on the display.
• Give the compressor 3 minutes to turn on after the Cooling mode has been selected.
• Set the air conditioner to a lower temperature. It is recommended to set the temperature to at least 5°F of the ambient temperature.
• Either manually drain the water by removing the drain plug or allow the unit to exhaust the water
itself by running the fan only mode. Then cooling will resume.
The air coming out of the unit is not very cold, or the airflow volume is weak| • The filters are dirty or obstructed.
• The air intake or exhaust is obstructed.
• The unit is set in DRY or FAN mode.
• The unit is set to low fan speed.
| • Clean the air filters.
• Make sure there is at least 20″ of clearance from the air intake. Make the length of the exhaust hose is as short as possible.
• Set the unit to the cooling mode.
• Set the unit to a higher fan speed.
---|---|---
The unit has worked for a long time, but the room is not cold enough| •
Windows or doors are open.
• There are too many people in the room.
• There is direct sunshine into the room.
• The room is a kitchen or with many heat-producing appliances
• There is a server in the room.
• The room is too large.
| • Close all windows and doors.
• You may need additional cooling or another air conditioner.
• Close curtains or blinds and try to minimize the amount of direct sunlight into the room.
• You may need additional cooling or another air conditioner.
• You may need additional cooling or another air conditioner.
• You may need additional cooling or another air conditioner.
The unit is very noisy| • The unit is not level.
• The surface underneath the unit is uneven.
• Low power voltage.
| • Make sure the unit is on hard, level and stable surface.
• Move the unit to a location with a level and hard floor.
• Make sure the wall outlet and support the required power consumption of the air conditioner and do
not use an extension cord.
The unit leaks water| • The unit is tilted or not leveled
• The water tank is full.
| • Make use the unit is leveled.
• Drain water from the drain plug at the back of the air conditioner.
The unit needs to be drained too often| • The humidity in the area may very high
• Possible loose connection
| • Remove the intake hose if the outside humidity is high or it is raining
• Contact Whvnter Service Department
Fan speed cannot be changed| • Fan speed differences are not very noticeable| • The fan speed difference is not very noticeable when the compressor is on. Try setting the unit to Fan only mode, you should be able to hear the
difference between high and low fan speed settinqs.
ONE YEAR LIMITED WARRANTY & THREE YEAR WARRANTY ON COMPRESSOR
This WHYNTER product is warranted to the original owner, purchased from an
authorized Whynter dealer within the 48 U.S. continental states, for one year
from the original purchase date against defects in material and workmanship
under normal residential usage. Should your WHYNTER product prove defective
within one year from the date of purchase,
contact Whynter’s Customer Support team with the serial number and proof of
purchase to make a warranty claim. A Return Authorization number must be
issued before returning any parts or products. Parts or products received
without a Whynter issued Return Authorization number will be refused. Under
this warranty, Whynter will repair or replace any parts found defective with
new or remanufactured parts or exchange the defective product with a new,
refurbished, or remanufactured product at our discretion. All defective
products and parts covered by this warranty will be repaired or replaced on a
mail-in basis to Whynter’s Service Center. This warranty is not transferable.
After the expiration of the warranty, the cost of labor and parts will be the
responsibility of the original owner.
The compressor of portable air conditioners is warranted for an additional two years after the one year limited warranty expires from the date of purchase. Return freight is prepaid by Whynter within two months of purchase. After two months to one year, the customer will be responsible for the return freight cost to Whynter’s Service Center. Please package the product carefully in its original packaging to avoid damage in transit. Whynter is not responsible for damage resulting from shipper mishandling or improper packaging. Please retain the original box and packaging materials.
THIS WARRANTY DOES NOT COVER:
- Acts of God, such as fire, flood, hurricanes, earthquakes and tornadoes.
- Improper power supply such as power surge, low voltage, defective household wiring or inadequate fuses.
- Use in commercial or industrial applications.
- Damage, accidental or otherwise, to the product while in the possession of a consumer not caused by a defect in material or workmanship.
- Damage caused by consumer misuse, tampering, lack of maintenance or failure to follow the care and special handling provisions in the instructions.
- Damage to the finish of the case, or other appearance parts caused by wear.
- Damage caused by repairs or alterations to the product by anyone other than authorized by the manufacturer.
- Removal, Replacement Packaging, Freight and Insurance cost for the warranty service.
- Products sold AS IS or from an unauthorized reseller.
- Products that have had their serial numbers removed or defaced.
DISCLAIMER OF IMPLIED WARRANTIES;
LIMITATION OF REMEDIES CUSTOMER’S SOLE AND EXCLUSIVE REMEDY UNDER THIS LIMITED WARRANTY SHALL BE PRODUCT REPAIR OR REPLACEMENT AS PROVIDED HEREIN. CLAIMS BASED ON IMPLIED WARRANTIES, INCLUDING WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, ARE LIMITED TO ONE YEAR OR THE SHORTEST PERIOD ALLOWED BY LAW, BUT NOT LESS THAN ONE YEAR. WHYNTER SHALL NOT BE LIABLE FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES SUCH AS PROPERTY DAMAGE AND INCIDENTAL EXPENSES RESULTING FROM ANY BREACH OF THIS WRITTEN LIMITED WARRANTY OR ANY IMPLIED WARRANTY. SOME STATES AND PROVINCES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSE- QUENTIAL DAMAGES, OR LIMITATIONS ON THE DURATION OF IMPLIED WARRANTIES, SO THESE LIMITATIONS OR EXCLUSIONS MAY NOT APPLY TO YOU. THIS WRITTEN WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS. YOU MAY ALSO HAVE OTHER RIGHTS THAT VARY FROM STATE TO STATE.
The warranty, product contents and specifications are subject to change at any time without notice; please refer to www.whynter.com for the most current information.
Please retain the original proof of purchase.
To register your warranty, please visit www.whynter.com and fill out the
online Warranty Registration form. Please be sure to include a copy of your
purchase invoice.
To obtain service or information, contact Whynter LLC via email at
support@whynter.com or call 866-WHYNTER
(866-949-6837).
Copyright© 2019 Whynter LLC www.whynter.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>