INSTALLATION INSTRUCTION
- Assembly should be carried out by a qualified person.
- Dirtiness that settle down on the diffuser due to normal operation of the fitting shall be cleaned with a damp cloth. Do not use abrasive cleaners.
- We would like to inform you that our product’s are marked in accordance with the European Directive 2002/96/CE and Polish Act o n used electric and electronic
equipment with a sign of a crossed-out waste container: This mark informs abort the fact that the device, after its application use, cannot be placed together with other types of household waste. The user is obliged to return it to the entities conducting a collection of used electric and electronic equipment. The collection points, including local collection points, shops and municipal entities create a proper system making it possible for the return of the equipment. Proper proceeding with used electric and electronic equipment contributes to the avoidance of damaging consequences for the health of the inhabitants and natural environment chick result form the presence of dangerous substances and improper storage and processing of such devices and equipment.
INSTALLATION INSTRUCTIONS
powering
INDICATORS
- GREEN UP TO 8000H – OK
- YELLOW 8000H – 9000H CLOSE TO END OF LIFESPAN
- RED OVER 9000H – REPLACE WITH NEW UV-C TUBES
- RED BLINKING FAULTY TUBES
The light source used in this luminaire should only be replaced by the manufacturer or his maintenance representative, or a similarly qualified person.
IMPORTANT INSTRUCTIONS FOR SAFE USE
WARNING BEFORE USING LAMP FOR THE FIRST TIME, READ THE USER MANUAL AND FOLLOW THE INSTRUCTIONS.
UV-C STERILON SQUARE HEPA 2 PP flow luminaires use ultraviolet light, destroy the DNA or RNA of all microorganisms that will be exposed and remove viruses, bacteria and mould from the air. The shielded UVC light does not escape to the outside of the luminaire. Thanks to stimulated circulation, the air passes through the luminaire interior, where it is exposed to the light and disinfected, and then pushed outside. Luminaires can work in the presence of people.
Exposure method:
-
Install the luminaire in a disinfected room, in a central place, if possible, to increase the effectiveness of disinfection. Remember that the disinfection efficiency in a given place depends on the number of luminaires 2 3
and the area of the room. The maximum area (cubic capacity) of a disinfected room is approx. 50 m (150 m ). -
In order not to disturb air circulation, do not cover the luminaire fans.
-
There may be people in the room. They can move freely and do not need protective clothing.
-
Do not open the luminaire covers during its operation. Secure the luminaire against uncontrolled opening by other people
-
Do not use in rooms smaller than 1 m .
-
The smell emitted by the luminaire is a technical smell. It may last for approximately 60 hours when the device is used. This smell does not pose any threat to luminaire users.
-
A small amount of visible blue light – it is reflected light, which does not contain UV-C radiation and is safe for humans.
Operational safety
The UV-C light is highly harmful to humans and other living organisms, damages eyesight, skin, and cell DNA. UV-C light degrades the DNA and RNA code in the cells of living organisms. In the event of damage to the luminaire housing, no people or animals should be within the range of direct UVC rays. Damage to the luminaire will not anact your health if basic precautions are maintained. In this case, turn the lamp off immediately. If the fluorescent lamps break, ventilate the room for 30 minutes and remove the contaminated parts, preferably with gloves. Place them in a sealed plastic bag and take to a local waste disposal facility for recycling. Do not use a vacuum cleaner to remove damaged parts. Proper use of the luminaire does not pose any threat to life and health