VENTURE LIGHTING BF0001 LED Troffer Fixture User Manual

June 8, 2024
VENTURE LIGHTING

VENTURE LIGHTING BF0001 LED Troffer Fixture
VENTURE LIGHTING BF0001 LED Troffer Fixture

WARNING ICONBefore You Begin
Read These Instructions Completely and Carefully

Upgrade Instructions

  • STEP 1: Disconnect power from the existing luminaire and follow proper lockout/tagout procedures before beginning installation or maintenance.

  • STEP 2: Remove the existing luminaire. Dispose of the lamp(s) and ballast(s) per local requirements.

  • STEP   3: Each corner of the fixture has a mounting tab (4 mounting tabs total). Bend each mounting tab up and then bend the tab again (approximately 90°) so the mounting tab can be secured to the T grid. (A)

  • STEP 4: Place the fixture into a T-grid. (B)

  • STEP 5: Ensure the mounting tab is securely hooked onto a T-grid.

  • STEP 6: Remove the wiring compartment cover plate. (C)
    Upgrade Instructions

  • STEP 7: Make the necessary wiring connections as shown in the wiring diagram. (D)
    Upgrade Instructions
    NOTE: The polarity of the dimming connections is important to ensure the performance as desired.
    NOTE: If not using the dimming functionality, DO NOT connect the Driver Dim+ (purple) to the Driver DIM- (gray). The fixture will not operate as desired.

  • STEP 8: Replace and secure the wiring cover plate.

  • STEP 9: Power can now be restored to the fixture.

WARNING

Risk of fire and electric shock

  • Disconnect power from the luminaire and follow proper lockout/tagout procedures before beginning installation or maintenance. Contact a qualified electrician for installation.
  • Venture Lighting’s LED Troffer Fixture installation requires knowledge of luminaire electrical systems. If not qualified, do not attempt installation. Contact a qualified electrician.
  • To prevent wiring damage or abrasion, do not expose wiring to edges of sheet metal or other sharp objects.
  • The product should be installed and operated by a qualified electrician or technician in accordance with relevant local codes.
  • Check to make sure that all fixture connections have been properly made and the fixture is grounded to avoid potential electrical shocks.
  • Do not handle energized fixture when hands are wet, when standing on wet or damp surfaces, or in water.
  • Suitable for use in damp and dry locations.
  • Venture Lighting’s LED Troffer Fixture is Type IC.
  • Use minimum 90°C supply conductors.
  • The installer must determine that the supply voltage meets the fixture requirement.

CUSTOMER SERVICE

800-451-2606
6675 Parkland Blvd., Suite 100
Solon, OH 44139 USA
E-mail: [email protected]
VentureLighting.com

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

VENTURE LIGHTING User Manuals

Related Manuals