VENTURE LIGHTING BF0001 LED Troffer Fixture User Manual
- June 8, 2024
- VENTURE LIGHTING
Table of Contents
VENTURE LIGHTING BF0001 LED Troffer Fixture
Before You Begin
Read These Instructions Completely and Carefully
Upgrade Instructions
-
STEP 1: Disconnect power from the existing luminaire and follow proper lockout/tagout procedures before beginning installation or maintenance.
-
STEP 2: Remove the existing luminaire. Dispose of the lamp(s) and ballast(s) per local requirements.
-
STEP 3: Each corner of the fixture has a mounting tab (4 mounting tabs total). Bend each mounting tab up and then bend the tab again (approximately 90°) so the mounting tab can be secured to the T grid. (A)
-
STEP 4: Place the fixture into a T-grid. (B)
-
STEP 5: Ensure the mounting tab is securely hooked onto a T-grid.
-
STEP 6: Remove the wiring compartment cover plate. (C)
-
STEP 7: Make the necessary wiring connections as shown in the wiring diagram. (D)
NOTE: The polarity of the dimming connections is important to ensure the performance as desired.
NOTE: If not using the dimming functionality, DO NOT connect the Driver Dim+ (purple) to the Driver DIM- (gray). The fixture will not operate as desired. -
STEP 8: Replace and secure the wiring cover plate.
-
STEP 9: Power can now be restored to the fixture.
WARNING
Risk of fire and electric shock
- Disconnect power from the luminaire and follow proper lockout/tagout procedures before beginning installation or maintenance. Contact a qualified electrician for installation.
- Venture Lighting’s LED Troffer Fixture installation requires knowledge of luminaire electrical systems. If not qualified, do not attempt installation. Contact a qualified electrician.
- To prevent wiring damage or abrasion, do not expose wiring to edges of sheet metal or other sharp objects.
- The product should be installed and operated by a qualified electrician or technician in accordance with relevant local codes.
- Check to make sure that all fixture connections have been properly made and the fixture is grounded to avoid potential electrical shocks.
- Do not handle energized fixture when hands are wet, when standing on wet or damp surfaces, or in water.
- Suitable for use in damp and dry locations.
- Venture Lighting’s LED Troffer Fixture is Type IC.
- Use minimum 90°C supply conductors.
- The installer must determine that the supply voltage meets the fixture requirement.
CUSTOMER SERVICE
800-451-2606
6675 Parkland Blvd., Suite 100
Solon, OH 44139 USA
E-mail:
Venture_Lighting@VentureLighting.com