MVS50/LCB High Bay Low Voltage MVS Controller
Hello
The Lightcloud Blue High Bay Low Voltage MVS Controller is a controller with
12V AUX supply and intergrated with dual-techology motion detector and
daylight sensor that can switch and dim both local and remote circuits. The
Lightcloud Blue High Bay Low Voltage Controller can be quickly and easily
installed on compatible LED fixtures.
Specifications
PART NUMBER
MVS50/LCB| PRODUCT DIMENSIONS
2.125”D x 2.125”L x 1.43”H
---|---
WIRELESS Range
60 ft.| SENSOR COVERAGE
20 ft. diameter at 49 ft.
SENSOR TYPE
Microwave (MVS)| SENSOR CONNECTION
3-pogo pin
ENVIRONMENT
Indoor/Outdoor (IP65)| MOUNTING HEIGHT
49 ft.
Setup & Installation
-
Turn off power
WARNING 1a Find a suitable location
• Lightcloud Blue devices should be positioned within 60 ft. of each other.
• Building materials such as brick, concrete and steel construction may require additional Lightcloud Blue devices to extend around an obstruction. -
Wiring Diagram
Install the Lightcloud Blue High Bay Low Voltage MVS Controller by below wiring diagram.
Black White +12V 12VDC input
Pink GND 0/1-10V DIM
Purple DIM+ 0/1-10V DIM+ -
Install Luminaire
High Bay Low Voltage MVS Controller is only compatible with select sensor- ready fixtures.
Visit www.rablighting.com to see the full compatibility list.
3a Mount the High Bay Low Voltage MVS Controller to a compatible fixture. Unscrew the 1/2″ knockout out with a screwdriver and screw on the High Bay Low Voltage MVS Controller. 3b Mount the High Bay Low Voltage MVS Controller with Bracket (RAAS):
Screw the High Bay Low Voltage MVS Controller onto the Bracket (RAAS) and connect the
Bracket (RAAS) to a 1/2″ knockout on the fixture, see the section 2 Wiring Diagram for wiring instructions. -
Turn power on
-
Enable Device Pairing Mode
If your Lightcloud Blue High Bay Low Voltage MVS Controller is already paired, you can reset it by using Rapid Reset Tool Method.
The rapid reset process must be done by professional electricians qualified by RAB. Reach out to your RAB sales manager to request a Rapid Reset Tool. The tool simply needs to be placed directly on side of device for 2 seconds.
Controlling your Lightcloud Blue Device
- Confirm your device is powered on.
- Download the Lightcloud Blue app from the Apple® App Store or Google® Play store.
- Launch the App and create an account.
- Tap the “add device” icon in the app to start connecting devices.
- Follow the remaining steps in the app. Create areas, groups, and scenes to organize and control your devices.
- Adjust the Dim-to- Off Threshold (0-2V) to get the lowest dim level in the device setting. (Default threshold 1V)
- You’re all set!
Sensor Coverage
Highest mounting height is 15m/49ft: this figure indicates the maximum distance at the highest mounting height with 100% sensitivity.
FCC Information:
This device complies with Part 15 of the FCC Rules. Operation is subject to
the following two conditions:
- This device may not cause harmful interference, and
- This device must accept any interference received, including interference that may cause undesired operation.
Note: This device has been tested and found to comply with the limits for
Class B digital devices pursuant to Part 15 Subpart B, of the FCC rules. These
limits are designed to provide reasonable protection against harmful
interference in a residential environment. This equipment generates, uses, and
can radiate radio frequency energy, and if not installed and used in
accordance with the instruction manual, may cause harmful interference to
radio communications. However, there is no guarantee that interference will
not occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try and correct the
interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
To comply with the FCC’s RF exposure limits for general population /
uncontrolled exposure, this transmitter must be installed to provide a
separation distance of at least 20 cm from all persons and must not be co-
located or operating in conjunction with any other antenna or transmitter.
CAUTION: Changes or modifications to this equipment not expressly approved
by RAB Lighting may void the user’s authority to operate this equipment.
Configuration
All configuration of Lightcloud Blue products may be performed using the
Lightcloud Blue mobile app.
Learn more at www.rablighting.com
1(844) LIGHTCLOUD
1(844) 544-4825
©2022 RAB LIGHTING Inc.
Custom manufactured in China
Pat.rablighting.com/ip
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>