Cherubini META ENERGY DRIVEN SWITCH-C 7 A510086 Manual

June 8, 2024
Cherubini

Cherubini

META ENERGY DRIVEN SWITCH-C 7

SKU: A510086

Quickstart

This is a
secure
Meter Sensor DT
for
.

To run this device please connect it to your mains power supply.

Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law.
The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material.
Use this equipment only for its intended purpose. Follow the disposal instructions.

Do not dispose of electronic equipment or batteries in a fire or near open heat sources.

What is Z-Wave?

Z-Wave is the international wireless protocol for communication in the Smart Home. This
device is suited for use in the region mentioned in the Quickstart section.

Z-Wave ensures a reliable communication by reconfirming every message ( two- way
communication
) and every mains powered node can act as a repeater for other nodes
( meshed network ) in case the receiver is not in direct wireless range of the
transmitter.

This device and every other certified Z-Wave device can be used together with any other
certified Z-Wave device regardless of brand and origin
as long as both are suited for the
same frequency range.

If a device supports secure communication it will communicate with other devices
secure as long as this device provides the same or a higher level of security.
Otherwise it will automatically turn into a lower level of security to maintain
backward compatibility.

For more information about Z-Wave technology, devices, white papers etc. please refer
to www.z-wave.info.

Product Description

META Energy Driven Switch C 7 monitors all parameters, usage, faults and overloads of the electrical system. A bi-directional meter that measures consumed and produced power.

Prepare for Installation / Reset

Please read the user manual before installing the product.

In order to include (add) a Z-Wave device to a network it must be in factory default
state.
Please make sure to reset the device into factory default. You can do this by
performing an Exclusion operation as described below in the manual. Every Z-Wave
controller is able to perform this operation however it is recommended to use the primary
controller of the previous network to make sure the very device is excluded properly
from this network.

Safety Warning for Mains Powered Devices

ATTENTION: only authorized technicians under consideration of the country- specific
installation guidelines/norms may do works with mains power. Prior to the assembly of
the product, the voltage network has to be switched off and ensured against re-switching.

Inclusion/Exclusion

On factory default the device does not belong to any Z-Wave network. The device needs
to be added to an existing wireless network to communicate with the devices of this network.
This process is called Inclusion.

Devices can also be removed from a network. This process is called Exclusion.
Both processes are initiated by the primary controller of the Z-Wave network. This
controller is turned into exclusion respective inclusion mode. Inclusion and Exclusion is
then performed doing a special manual action right on the device.

Quick trouble shooting

Here are a few hints for network installation if things dont work as expected.

  1. Make sure a device is in factory reset state before including. In doubt exclude before include.
  2. If inclusion still fails, check if both devices use the same frequency.
  3. Remove all dead devices from associations. Otherwise you will see severe delays.
  4. Never use sleeping battery devices without a central controller.
  5. Dont poll FLIRS devices.
  6. Make sure to have enough mains powered device to benefit from the meshing

Association – one device controls an other device

Z-Wave devices control other Z-Wave devices. The relationship between one device
controlling another device is called association. In order to control a different
device, the controlling device needs to maintain a list of devices that will receive
controlling commands. These lists are called association groups and they are always
related to certain events (e.g. button pressed, sensor triggers, …). In case
the event happens all devices stored in the respective association group will
receive the same wireless command wireless command, typically a ‘Basic Set’ Command.

Association Groups:

Group NumberMaximum NodesDescription

1| 5|
---|---|---
2| 5|
3| 5|
4| 5|
5| 5|

Configuration Parameters

Z-Wave products are supposed to work out of the box after inclusion, however
certain configuration can adapt the function better to user needs or unlock further
enhanced features.

IMPORTANT: Controllers may only allow configuring
signed values. In order to set values in the range 128 … 255 the value sent in
the application shall be the desired value minus 256. For example: To set a
parameter to 200 it may be needed to set a value of 200 minus 256 = minus 56.
In case of a two byte value the same logic applies: Values greater than 32768 may
needed to be given as negative values too.

Parameter 21: OUT_TYPE

Define the output type. (0: direct load control or normally Open relay, 1: normally Closed relay)
Size: 1 Byte, Default Value: 0

SettingDescription

0 0

Parameter 23: STARTUP_OUT

Define the output level on startup (0: OFF, 1: ON, 2: Previous status)
Size: 1 Byte, Default Value: 0

SettingDescription

0 0

Parameter 31: OFF_TIMEOUT

Time in tenth of second after which the output will be switched Off. 0: OFF timer disabled
Size: 4 Byte, Default Value: 0

SettingDescription

0 0

Parameter 32: ON_TIMEOUT

Time in tenth of second after which the output will be switched On. 0: ON timer disabled
Size: 4 Byte, Default Value: 0

SettingDescription

0 0

Parameter 40: UP_POWER_LOCAL_CONTROL

The value used to control the integrated Relay in case of Up Power Event.(0: OFF, 1: ON)
Size: 1 Byte, Default Value: 1

SettingDescription

0 0

Parameter 41: DOWN_POWER_LOCAL_CONTROL

The value used to control the integrated Relay in case of Down Power Event.(0: OFF, 1: ON)
Size: 1 Byte, Default Value: 1

SettingDescription

0 0

Parameter 42: METER_TYPE

Define how power value is treated (0: as is, 1: negative value 0, 2: positive value 0, 3: All positive, 4: All negative)
Size: 1 Byte, Default Value: 3

SettingDescription

0 0

Parameter 43: CT_TYPE

Define the Model of Current Transformer connected to the device (1: Standard Type, 2: Type2 version)
Size: 1 Byte, Default Value: 1

SettingDescription

0 0

Parameter 44: UP_POWER_REMOTE_CONTROL

The value used to control uP Power Group. (0-99: specific value, 100: ON)
Size: 1 Byte, Default Value: 0

SettingDescription

0 0

Parameter 45: DOWN_POWER_REMOTE_CONTROL

The value used to control Down Power Group. (0-99: specific value, 100: ON)
Size: 1 Byte, Default Value: 100

SettingDescription

0 0

Parameter 46: OVER_VOLTAGE_LIMIT

Define the Over Voltage Limit in tenth of volt
Size: 2 Byte, Default Value: 2530

SettingDescription

0 0

Parameter 47: DOWN_VOLTAGE_LIMIT

Define the Down Voltage Limit in tenth of volt
Size: 2 Byte, Default Value: 2070

SettingDescription

0 0

Parameter 50: UP_POWER_LEVEL

Sets the level in Watts beyond which time of permanence above this level is calculated. 0: Up Power Event Disabled
Size: 4 Byte, Default Value: 0

SettingDescription

0 0

Parameter 51: UP_POWER_TYPE

Define if the Up Power is consumed or produced (0: consumed, 1: produced)
Size: 1 Byte, Default Value: 0

SettingDescription

0 0

Parameter 52: UP_POWER_FIRST_TIMEOUT

Define the time of permanence in seconds above the Up power level after which the First Up Power event occurs
Size: 2 Byte, Default Value: 30

SettingDescription

0 0

Parameter 53: UP_POWER_NEXT_TIMEOUT

Define the time of permanence in seconds above the Up power level after which the Next Up Power event occurs
Size: 2 Byte, Default Value: 5

SettingDescription

0 0

Parameter 54: DOWN_POWER_LEVEL

Sets the level in Watt beyond which time of permanence below this level is calculated. 0: Down Power Event Disabled
Size: 4 Byte, Default Value: 0

SettingDescription

0 0

Parameter 55: DOWN_POWER_TYPE

Define if the Down Power is consumed or produced (0: consumed, 1: produced)
Size: 1 Byte, Default Value: 0

SettingDescription

0 0

Parameter 56: DOWN_POWER_FIRST_TIMEOUT

Define the time of permanence in seconds below the Down Power level after which the first Down Power event occurs
Size: 2 Byte, Default Value: 30

SettingDescription

0 0

Parameter 57: DOWN_POWER_NEXT_TIMEOUT

Define the time of permanence in seconds below the Down Power level after which the next Up Down event occurs
Size: 2 Byte, Default Value: 5

SettingDescription

0 0

Parameter 58: PROTECTION_TIME

Define the minimum time is second after which an Up/Down Power Event can be trigger again
Size: 2 Byte, Default Value: 60

SettingDescription

0 0

Parameter 71: METER_REPORT_MAX_DELAY

The Maximum Time in minute after which the next Meter sequence report will be sent
Size: 1 Byte, Default Value: 10

SettingDescription

0 0

Parameter 75: METER_ISTANT_REPORT

The percentage change of Power from the last sent report that triggers a new meter report sequence
Size: 1 Byte, Default Value: 20

SettingDescription

0 0

Parameter 76: REPORT_CONFIG

Define which Report scale will be sent. (0:none, 1:Energy , 4:Power, 16:Voltage, 32:Current, 64:Power Factor)
Size: 1 Byte, Default Value: 117

SettingDescription

0 0

Technical Data

Hardware Platform ZGM130S037HGN2 / ZGM130S037HGN1
Device Type Meter Sensor DT
Network Operation Always On Slave
Firmware Version HW: 01 FW: 07.00
Z-Wave Version 7.16.3
Certification ID ZC14-22050103
Security V2 S2_UNAUTHENTICATED ,S2_AUTHENTICATED
Frequency XXfrequency
Maximum transmission power XXantenna

Supported Command Classes

  • Application Status
  • Association Grp Info V3
  • Association V2
  • Configuration V4
  • Device Reset Locally
  • Firmware Update Md V5
  • Indicator V3
  • Manufacturer Specific V2
  • Meter V5
  • Multi Channel Association V3
  • Notification V8
  • Powerlevel
  • Security 2
  • Supervision
  • Transport Service V2
  • Version V3
  • Zwaveplus Info V2

Explanation of Z-Wave specific terms

  • Controller — is a Z-Wave device with capabilities to manage the network.
    Controllers are typically Gateways,Remote Controls or battery operated wall controllers.

  • Slave — is a Z-Wave device without capabilities to manage the network.
    Slaves can be sensors, actuators and even remote controls.

  • Primary Controller — is the central organizer of the network. It must be
    a controller. There can be only one primary controller in a Z-Wave network.

  • Inclusion — is the process of adding new Z-Wave devices into a network.

  • Exclusion — is the process of removing Z-Wave devices from the network.

  • Association — is a control relationship between a controlling device and
    a controlled device.

  • Wakeup Notification — is a special wireless message issued by a Z-Wave
    device to announces that is able to communicate.

  • Node Information Frame — is a special wireless message issued by a
    Z-Wave device to announce its capabilities and functions.