CHERUBINI A510078 Meta Wired Motor Controller Instructions

June 13, 2024
Cherubini

CHERUBINI-LOGO

CHERUBINI A510078 Meta Wired Motor Controller

Product Information

Product Name: A510078 META WIRED MOTOR CONTROLLER 7
Product Description: Actuator for motors with standard connection EN
Technical Specifications: Power supply, Maximum Load, System temperature

limitation, Work
temperature, Power consumption, Radiofrequency, Protection system,
Maximum distance, Dimensions, Actuator element, Compliance,
Electrical IP Rating
Safety Information:| Refer to the user manual for safety instructions and
precautions.
Supported Command Classes:| BASIC, ZWAVEPLUS_INFO, INDICATOR, ASSOCIATION,
MULTI_CHANNEL_ASSOCIATION, ASSOCIATION_GRP_INFO, TRANSPORT_SERVICE,
VERSION, MANUFACTURER_SPECIFIC, POWER LEVEL, CONFIGURATION,
SECURITY_2, SUPERVISION, FIRMWARE_UPDATE_MD, WINDOW_COVERING,
MULTILEVEL, NOTIFICATION

Product Usage Instructions

  1. Make sure the main switch is set to the OFF position.
  2. Connect the device based on the provided diagrams.
  3. Turn the main switch to the ON position.
  4. If necessary, calibrate the motor limit switches according to the motor manufacturer’s manual.
  5. Include the device in the Z-WaveTM network.

Note: The antenna must not be shortened, removed, or modified. To ensure maximum efficiency, it must be installed as shown. Large-size metal equipment near the antenna can negatively affect reception. Each device is a node in a mesh network. If there are metal obstacles, the obstacle can often be overcome with a further triangulation node.

LED Status Indicator:
To test if the electrical connections are correct, press the external switch n times before including the device. The RGB LED should flash green for the same amount of time. If it does not, check the wire connections.

Add/Remove the Device into a Z-WaveTM Network (classic):
Refer to the user manual for detailed instructions on adding or removing the device from a Z-WaveTM network.

SmartStart Inclusion:
Refer to the user manual for detailed instructions on using SmartStart inclusion.

S2 Secure Inclusion:
When adding META Serie 7 devices to a Z-WaveTM network with a controller supporting Security 2 Authenticated (S2), the PIN code of the Z-WaveTM Device Specific Key (DSK) is required. The unique DSK code is printed on the product label. The first five digits of the key are highlighted and underlined to help the user identify the PIN code.

EU declaration of conformity
CHERUBINI S.p.A. declares that the product conforms with the relevant Union harmonisation legislation: Directive 2014/53/EU, Directive 2011/65/EU. The full text of the EU declaration of conformity is available upon request at the following website: www.cherubini.it.

Failure to comply with these instructions annuls CHERUBINI’s responsibilities and guarantees The crossed-out wheelie bin symbol indicates that the product must be collected separately from other waste at the end of its useful life. Therefore, users should deliver this product to appropriate waste collection points or return it to their dealers at the end of its service. See your local authority’s regulations. Adequate waste sorting for subsequent processing and environmentally compatible disposal helps to avoid possible negative effects on the environment and public health. It promotes reuse and/or recycling of the materials used to make the equipment.

DEVICE DESCRIPTION

META Wired Motor Controller 7 is an “in-wall device”, for the multilevel control of roller shutter motors. It can accurately control the opening and closing of blinds, curtains, shutters, and Venetian blinds as requested by the user through local commands or remotely using computers, smartphones, and tablets. At the same time, it is completely configurable so that it can adapt to the most varied customers’ needs while being ready for use without needing additional configurations to operate. After an initial calibration procedure, thanks to a proprietary algorithm, the device can identify the exact position of the roller shutter without using external sensors. During the operation, continuous and automatic control of the limit switches allows for maintaining the calibration. In the absence of a power source, the system runs a self- repositioning procedure that restores calibration. The device is equipped with contact protection technology (Zero Crossing) which reduces the electrical stress on the relay contacts and ensures a longer life. The open/closed switching of the device always occurs when the instantaneous value of voltage is 0. It operates in any Z-Wave™ network with other  Z-Wave™/Z-Wave  Plus™ certified devices and controllers from any other manufacturer. As a constantly powered node, the device will act as a repeater regardless of the vendor to increase the reliability of the network. This device is a security-enabled Z-Wave Plus™ product that can use encrypted Z-Wave Plus™ messages to communicate with other security-enabled Z-Wave Plus™ products. This device must be used in conjunction with a Security Enabled Z-Wave™ Controller to fully utilize all implemented functions.CHERUBINI-A510078-Meta-Wired-Motor-
Controller-FIG- \(1\)

  • Integrated Button : 1 or 3 clicks to enter Learn Mode 6 clicks to reset the system to manufacturer’s settings 2 clicks to enter setup mode
  • Power Supply : 1 – Null 6 – Line
  • Open/Close Buttons: 2, 3
  • Motor Contacts : 4, 5

TECHNICAL SPECIFICATIONS

  • Power supply 110 – 230 VAC ± 10% 50/60 Hz
  • Maximum Load 1200 Watt
  • System temperature limitation 105 °C
  • Work temperature From -10° to 40° C
  • Power consumption
    • < 230 mW in standby mode
    • < 500 mW when the motor is moving
  • Radio frequency 868.4 MHz
  • Protection system S2 Security
  • Maximum distance Up to 100 m outdoor
  • Up to 40 m indoor
  • Dimensions 37x37x17 mm
  • Actuator element Relay
  • Compliance CE, RoHS
  • Electrical IP Rating IP20

SAFETY INFORMATION

  • INFO : The device is designed to be installed in flush mounting junction boxes or close to the motor to be controlled.
  • WARNING : The device must be installed by electricians qualified to intervene in electrical systems in compliance with safety requirements set out by the regulations in force.
  • DANGER : The device must be connected with a voltage of 230 VAC, before carrying out any operation, please make sure the power main switch is in the OFF position.
  • DANGER : Any procedure requiring the use of the Integrated Button is related only to the installation phase and is to be considered a service procedure that must be performed by qualified personnel. This operation must be performed with all necessary precautions for operating in areas with a single level of insulation.
  • WARNING : Do not connect loads that exceed the maximum load permitted by the actuator element.
  • WARNING : All connections must be performed according to the electrical diagrams provided.
  • WARNING : The device must be installed in norm-compliant systems suitably protected from overloads and short circuits.

ELECTRICAL CONNECTIONS DIAGRAM
The device must be supplied by 230 AC Power Supply. Connections must be done following one of the diagrams below:

CHERUBINI-A510078-Meta-Wired-Motor-Controller-FIG-
\(2\)

  • Power Supply 1 – Null 6 – Line
  • Commands Switch 2, 3
  • Motor terminals 4, 5

WARNING : The power line must be opportunely protected from short circuits and excess load due to a potential motor malfunction.

DEVICE INSTALLATION

  1. Make sure the main switch is set to the OFF position
  2. Connect the device based on the diagrams provided
  3. Turn the main switch to the ON position
  4. If necessary, calibrate the motor limit switches (see motor manufacturer’s manual)
  5. Include the device in the Z-WaveTM network

TIP : The antenna must not be shortened, removed or modified. To ensure maximum efficiency, it must be installed as shown. Large-size metal equipment near the antenna can negatively affect reception. Each device is a node in a mesh network. If there are metal obstacles, the obstacle can often be overcome with a further triangulation node

LED STATUS INDICATOR

TIP : The antenna must not be shortened, removed or modified. To ensure maximum efficiency, it must be installed as shown. Large-size metal equipment near the antenna can negatively affect reception. Each device is a node in a mesh network. If there are metal obstacles, the obstacle can often be overcome with a further triangulation node.

The system includes an RGB LED that shows the device’s status during installation:

  • Solid RED: the device is not included in any network
  • Solid BLUE: the device is in Offline setup mode
  • Blink BLUE: calibration
  • 4 GREEN blinks then OFF: the device has been just added to a Z-WaveTM network in S2 Authenticate Mode
  • 4 BLUE blinks then OFF: the device has been just added to a Z-WaveTM network in S2 Unauthenticated Mode
  • 4 RED blinks then OFF : the device has been just added to a Z-WaveTM network without security
    • Sequence of GREEN-BLUE Learn Mode for inclusion
    • Sequence of RED-BLUE Learn Mode for exclusion
    • A rapid sequence of GREEN-BLUE-RED: the event on the input (external switch) is not valid.

TIP : To test if the electrical connections are correct, before the inclusion of the device, while pressing n times the external switch, the RGB LED should flash green for the same amount of times. If it does not, check the wire connections.

ADD/REMOVE THE DEVICE INTO A Z-WAVETM NETWORK (classic)

Standard Inclusion (add)

All META Serie 7 devices are compatible with all Z-WaveTM/Z-Wave PlusTM certified controllers. The devices support both the Network Wide Inclusion mechanism (which offers the ability to be included in a network, even if the device is not directly connected to the controller) and Normal Inclusion. By default, the inclusion procedure starts in Normal Inclusion mode and after a short timeout, the procedure continues in Network Wide Inclusion mode which lasts for about 20 Seconds. Only a controller can add the device to the network. After activating the inclusion function by the controller, the device can be added by setting it in Learn Mode.

Before including the device, the LED status indicator is solid RED. The adding of a device is executed by activating the adding procedure in the inclusion section of the controller interface and then executing 1 or 3 clicks on the integrated button (the device is set in Learn Mode). As soon as the inclusion procedure initiates the LED indicator starts a sequence of GREEN-BLUE blinks. The device is included in the network when the LED status is OFF and the interview is completed.

Standard exclusion (remove)
Only a controller can remove the device from the network. After activating the exclusion function by the controller, the device can be removed by setting it in Learn Mode. The procedure of exclusion can be activated by Removing a node from the Z-WaveTM network and executing 1 or 3 clicks on the integrated button; as soon as the exclusion initiates, the LED indicator starts a sequence of RED-BLUE blinks. The device is excluded from the network when the LED status indicator is solid RED and the App_status in the interface is OK.

SMARTSTART INCLUSION

Z-WaveTM SmartStart aims to shift the tasks related to the inclusion of an end device into a Z-WaveTM network away from the end device itself and towards the more user-friendly interface of the gateway.

Z-WaveTM SmartStart removes the need for initiating the end device to start inclusion. Inclusion is initiated automatically on power-ON and repeated at dynamic intervals for as long as the device is not included in a Z-WaveTM network. As the new device announces itself on power-ON, the protocol will provide notifications, and the gateway can initiate the inclusion process in the background, without the need for user interaction or any interruption of normal operation. The SmartStart inclusion process only includes authenticated devices.

META Serie 7 devices can be added to a Z-WaveTM network by scanning the Z-WaveTM QR Code present on the product with a controller providing SmartStart inclusion. No further action is required and the SmartStart product will be added automatically within 10 minutes of being switched on in the network vicinity. The SmartStart QR and the full DSK string code can be found on the back of the device. The PIN is the first group of 5 digits printed underlined. If you plan to use the DSK, you must take a picture of the label and keep it in a safe place

SECURE INCLUSION
When adding META Serie 7 devices to a Z-WaveTM network with a controller supporting Security 2 Authenticated (S2), the PIN code of the Z-WaveTM Device Specific Key (DSK) is required. The unique DSK code is printed on the product label. The first five digits of the key are highlighted and underlined to help the user identify the PIN code.

SUPPORTED COMMAND CLASSES


Command Class

| Version| Non-Secure CC| Secure CC
---|---|---|---
BASIC| 2|  | x
ZWAVEPLUS_INFO| 2| x|
INDICATOR| 2|  | X
ASSOCIATION| 2|  | x
MULTI_CHANNEL_ASSOCIATION| 3|  | x
ASSOCIATION_GRP_INFO| 2|  | x
TRANSPORT_SERVICE| 1| x|
VERSION| 2|  | x
MANUFACTURER_SPECIFIC| 2|  | x
POWERLEVEL| 1|  | x
CONFIGURATION| 4|  | x
SECURITY_2| 1| x|
SUPERVISION| 1|  | x
FIRMWARE_UPDATE_MD| 5| x|
WINDOW_COVERING| 1|  | x
MULTILEVEL| 4|  | x
NOTIFICATION| 9|  | x

Supporting Command Class Basic
The basic command classes are mapped into the Switch Multilevel Command Class.

Basic Command received Commando Mappato (multilevel Switch)
Basic Set (0xFF) Multilevel Switch (0xFF)
Basic Set (0x00) Multilevel Switch (0x00)
Basic Set (1, 0x63) Multilevel Switch (1, 0x63)
Basic GET Basic Report (Current Value, Target Value, Duration) Current Value

and Target Value MUST be set to 0xFE if not position-aware

Supporting Command Class Indicator
The device supports the Command Class Indicator V3 (ID 0x50). When the device receives an indicator set, the LED blinks according to the Indicator set received.

The colour shown by the indicator will be:

  • RED: if the device is included without Security
  • BLUE: if the device is included in S2 Unauthenticated Mode
  • GREEN: if the device is already included in S2 Authenticated Mode.

DEVICE CONTROL
META Wired Motor Controller 7 is an “in-wall device”, for the multilevel control of roller shutter motors. It can accurately control the opening and closing of blinds, curtains, shutters, and Venetian blinds by using an external switch, or from a remote through a controller.

Controlling the device by External Switches
For the operation of the device within the Z-WaveTM network and controlling the loads connected to the device, control actions are performed on the external switches.

The CONTROL ACTIONS are EVENTS executed on EXTERNAL SWITCHES connected to the UP and DOWN terminal of the device which can be Clicks, Hold Down and Up.

Event Type of switch Actions on the switch

Click

| ****




Double command button: UP/DOWN, open/close, ON/OFF

| Press briefly & Release

(when pressed it autonomously

returns to the initial position)

MultiClick= n click| Sequence of consecutive n clicks


Hold Down

| Press longer than click.

After a Hold Down always follows

a UP event.


Up

| Release.

The event applies only if there has

been a previous Hold Down event.

Device status: ON/OFF/STOP, Open/Close/Stop refers to the fact that the motor is rotating towards the direction Open/Close or it is stopped.

Result of Control Actions

  • Holding down the UP/DOWN button makes the motor move in the relevant direction and stops it as soon as the button is released (Up event) or the shutter reaches its limit switch.
  • A click ordering a UP/DOWN movement while the motor is moving in the opposite direction will stop the motor.
  • A click ordering a UP/DOWN movement while the motor is moving in the same direction will be ignored.
  • A single click on the UP/DOWN button makes the motor move until it reaches the limit switch for the UP/DOWN position.
  • A double click on the UP/DOWN button makes the motor move until it reaches the favourite position set for the UP/DOWN position.

Controlling the device by a Z-WaveTM controller
The device can be controlled by any Z-WaveTM / Z-Wave PlusTM certified controller available in the market. In the figure below, are represented a couple of examples of control panel interfaces that show how the device will appear once included into the Gateway.

CHERUBINI-A510078-Meta-Wired-Motor-Controller-FIG-
\(6\)

By moving the cursor in the scrollbar is possible to regulate the opening level of the shutter.

ASSOCIATIONS
META Wired Motor Controller 7 can control other devices like other relays or dimmers. The device supports 1 association group, which supports the association of up to 8 devices (nodes):

Group ID

|

Group Name

| N° of max nodes supported in the group|

Description

|

Command sent

---|---|---|---|---

1

|

Lifeline

|

8

| Lifeline Group. Nodes belonging to this group will receive notifica- tions about device reset; and changes related to the shutter status and Indicator Status.| DEVICE_RESETLOCALLY NOTIFICATION

WIDOM COVERING REPORT

MULTILEVEL REPORT INDICATOR_REPORT

INFO : The Association ensures the direct transfer of control commands between devices and is performed without the participation of the main controller.

RESET TO THE FACTORY SETTINGS
The device can be reset to the original factory with 6 consecutive clicks on the integrated button. After the reset is completed, the device will reboot and a RED solid LED will be shown. Please use this procedure only when the network primary controller is missing or otherwise inoperable.

INFO : If the reset is performed while the device is still part of a network, it notifies the other devices that it has been removed (Device Reset Locally Notification).

FIRMWARE UPDATE
The system supports over-the-air firmware updates that do not require the device to be removed from its location. The firmware update can be activated from all certified controllers supporting version 2 of the Firmware Update function.

WARNING : The system will be rebooted at the end of the firmware update procedure. It is advisable to carry out the firmware update procedure only when necessary and following careful planning of the intervention.

OFFLINE SETUP MODE
The device has a unique feature that allows one to configure some parameters without using any user interface. This feature enables the professional user to set up the main features of the device in the field even if the device is not included in a Z-WaveTM Network.

  • When the device is included in the network all these configuration parameters will be maintained.
  • To enter offline setup mode, operate 2 clicks on the integrated button.
  • When the device is in Offline setup mode the LED becomes solid Blue and the following configurations are permitted:
    1 click| Invert the movement of the motor. Equivalent to set parameter

n. 61 to 1.

---|---
2 clicks| Reset calibration. Equivalent to set parameter n. 20 to 0.

3 clicks

| This configuration will apply only if the calibration is completed. Set “ON- OFF favourite Level”. The current level will be set as ON_ FAVORITE_LEVEL if the current level is greater than 49 or will be set as OFF_FAVORITE_LEVEL if the current level is smaller than 50. If you want to set both ON and Off favourite Levels you have to carry on this setup two times:

One time for the ON position by moving the motor in the chosen ON_FAVORITELEVEL; and a second time for the chosen OFF FAVORITE_LEVEL.

After receiving the command the LED blinks several times equal to the number of clicks recognized.
6 clicks| Exit from Offline setup mode and return to normal operation.
Hold down for 5 seconds| Reset all configuration parameters to their default value and return to normal operation.

After entering Offline setup mode, the device returns to normal operation if no action on the switch is detected for more than 20 Seconds.

CONFIGURATIONS

Favorite positions
The system can set two favorite positions: one for the upward movements (opening movements) Favorite level for ON position, the other for the downward movements (closing movements) Favorite level for OFF position.

Parameter Number| Size| Parameter Name| Default Value| Description
---|---|---|---|---

2

|

1

| ON FAVORITE LEVEL|

80

| The On level was reached when the Up Button received a double click.
Parameters Values                                     Min: 50 Max: 99
Value| Description
50-99| 50-99% opening level (99% corresponds to completely open)
Parameter Number| Size| Parameter Name| Default Value| Description
---|---|---|---|---

3

|

1

| ON FAVORITE LEVEL|

20

| The Off level was reached when the Down Button received a double click.
Parameters Values                                    Min: 0 Max: 49
Value| Description
0-49| 0-49% opening level (0 corresponds to completely closed)

Calibration
Defines the status of the calibration procedure. By default, the calibration starts in automatic mode as soon as a movement command has been set by an external switch or by the Z-Wave™ network. Afterwards, the calibration can be done again by setting this parameter to 20 to 0 or using the offline setup mode. The calibration procedure can be made manually by setting the time needed to complete a full movement from complete close to complete open and vice versa. The procedure can be carried on by setting parameters 20 to 1 and parameters 21 and 22, to the appropriate time in milliseconds. During the calibration, the LED indicator blinks repeatedly in BLUE.

CHERUBINI S.p.A.
Via Adige 55 25081 Bedizzole (BS) – Italy

CHERUBINI Iberia S.L.
Avda. Unión Europea 11-H Apdo. 283 – P. I. El Castillo 03630 Sax Alicante – Spain

CHERUBINI France S.a.r.l.
ZI Du Mas Barbet 165 Impasse Ampère 30600 Vauvert – France

CHERUBINI Deutschland GmbH
Siemensstrasse, 40 – 53121 Bonn – Deutschland

Rev: 1 07/2022 – Cod: A4516_6P50