LEEDARSON Motion Sensor 7C-SS-VA-H0 Manual
- June 8, 2024
- LEEDARSON
Table of Contents
- LEEDARSON
- Motion Sensor
- SKU: 7C-SS-VA-H0
- Quickstart
- Important safety information
- What is Z-Wave?
- Product Description
- Prepare for Installation / Reset
- Inclusion/Exclusion
- Quick trouble shooting
- Association – one device controls an other device
- Configuration Parameters
- Parameter 10: Low Battery Power Level Low battery power level of alarm
- Parameter 13: Setup the wait time of PIR for clear the motion.
- Parameter 14: When the Motion Sensor is triggered, if this parameter is
- Parameter 15: PIR triggers the correspondence between the value of the
- Parameter 16: PIR triggers the correspondence between the value of the
- Parameter 17: Enable/disable pet immunity mode.
- Technical Data
- Supported Command Classes
- Controlled Command Classes
- Explanation of Z-Wave specific terms
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
LEEDARSON
Motion Sensor
SKU: 7C-SS-VA-H0
Quickstart
This is a
secure
Alarm Sensor
for
CEPT (Europe).
Please make sure the internal battery is fully charged.
To add this device to your network execute the following action:
Add the Motion Sensor into the Z-Wave network:1.Power on your Motion Sensor,
and let your Z-Wave controller into add/inclusion mode.2.Implement the button
action, the Motion Sensor will send out a node info security CC in command
class list (Security inclusion), the LED will be fast blink for 60
seconds.3.If the inclusion is successful, the LED will be turn on within 2
seconds. If failed, LED will be turn off forever, and please repeat the steps
in above.
Please refer to the
Manufacturers
Manual
for more information.
Important safety information
Please read this manual carefully. Failure to follow the recommendations in
this manual may be dangerous or may violate the law.
The manufacturer, importer, distributor and seller shall not be liable for any
loss or damage resulting from failure to comply with the instructions in this
manual or any other material.
Use this equipment only for its intended purpose. Follow the disposal
instructions.
Do not dispose of electronic equipment or batteries in a fire or near open heat sources.
What is Z-Wave?
Z-Wave is the international wireless protocol for communication in the Smart
Home. This
device is suited for use in the region mentioned in the Quickstart section.
Z-Wave ensures a reliable communication by reconfirming every message ( two-
way
communication) and every mains powered node can act as a repeater for other
nodes
( meshed network ) in case the receiver is not in direct wireless range of
the
transmitter.
This device and every other certified Z-Wave device can be used together
with any other
certified Z-Wave device regardless of brand and origin as long as both are
suited for the
same frequency range.
If a device supports secure communication it will communicate with other
devices
secure as long as this device provides the same or a higher level of security.
Otherwise it will automatically turn into a lower level of security to
maintain
backward compatibility.
For more information about Z-Wave technology, devices, white papers etc.
please refer
to www.z-wave.info.
Product Description
This motion sensor is a passive infrared sensor with pet immunity function. This sensor can effectively shield a certain weight of animals to prevent false triggering caused by animal passing. Motion Sensor can be included and operated in any Z-Wave network with other Z-Wave certified devices from other manufacturers. Motion Sensor is supports the Over-The-Air (OTA) feature for the products firmware upgrade.
Prepare for Installation / Reset
Please read the user manual before installing the product.
In order to include (add) a Z-Wave device to a network it must be in factory
default
state. Please make sure to reset the device into factory default. You can do
this by
performing an Exclusion operation as described below in the manual. Every
Z-Wave
controller is able to perform this operation however it is recommended to use
the primary
controller of the previous network to make sure the very device is excluded
properly
from this network.
Reset to factory default
This device also allows to be reset without any involvement of a Z-Wave
controller. This
procedure should only be used when the primary controller is inoperable.
Reset Motion Sensor to factory default.NOTE: 1.Triggering this action, in 5 seconds LED will be fast blink. The LED will be turn on within 2 second until hold time is equal to 5 seconds. Motion Sensor will send Device_Reset_Locally to the main controller and exclude from the Z-Wave network when the button is released, this procedure will reset the sensor to factory default.2.Please use this procedure only when the network primary controller is missing or otherwise inoperable. 3.When not in the network, ignore this operation.
Inclusion/Exclusion
On factory default the device does not belong to any Z-Wave network. The
device needs
to be added to an existing wireless network to communicate with the
devices of this network.
This process is called Inclusion.
Devices can also be removed from a network. This process is called
Exclusion.
Both processes are initiated by the primary controller of the Z-Wave network.
This
controller is turned into exclusion respective inclusion mode. Inclusion and
Exclusion is
then performed doing a special manual action right on the device.
Inclusion
Add the Motion Sensor into the Z-Wave network:1.Power on your Motion Sensor, and let your Z-Wave controller into add/inclusion mode.2.Implement the button action, the Motion Sensor will send out a node info security CC in command class list (Security inclusion), the LED will be fast blink for 60 seconds.3.If the inclusion is successful, the LED will be turn on within 2 seconds. If failed, LED will be turn off forever, and please repeat the steps in above.
Exclusion
Remove Motion Sensor from a Z-Wave network:1.Power on your Motion Sensor, and let the Z-Wave primary controller into remove mode.2.Press the button on the Motion Sensor, the LED will be turn on for 60 seconds.3.If Motion Sensor has been successfully removed from your Z-Wave network, the LED will be fast blink 2 seconds. If failed, LED will be turn off forever, and please repeat the steps in above.
Quick trouble shooting
Here are a few hints for network installation if things dont work as expected.
- Make sure a device is in factory reset state before including. In doubt exclude before include.
- If inclusion still fails, check if both devices use the same frequency.
- Remove all dead devices from associations. Otherwise you will see severe delays.
- Never use sleeping battery devices without a central controller.
- Dont poll FLIRS devices.
- Make sure to have enough mains powered device to benefit from the meshing
Association – one device controls an other device
Z-Wave devices control other Z-Wave devices. The relationship between one
device
controlling another device is called association. In order to control a
different
device, the controlling device needs to maintain a list of devices that will
receive
controlling commands. These lists are called association groups and they are
always
related to certain events (e.g. button pressed, sensor triggers, …). In case
the event happens all devices stored in the respective association group will
receive the same wireless command wireless command, typically a ‘Basic Set’
Command.
Association Groups:
Group NumberMaximum NodesDescription
1| 5| Lifeline1. Notification Report.Sensor will send Notification Report when
Motion Detection Unknown Location and (Event inactive).2. Motion Sensor
ReportSensor will send Multilevel Sensor Report (luminance) interval when PIR
triggered. 3. Battery Report.Sensor will send Battery Report when the battery
level is low and the battery reports value is 0xFF.4. Device Reset Locally.
---|---|---
2| 5| Send Basic Set when PIR trigger
Configuration Parameters
Z-Wave products are supposed to work out of the box after inclusion, however
certain configuration can adapt the function better to user needs or unlock
further
enhanced features.
IMPORTANT: Controllers may only allow configuring
signed values. In order to set values in the range 128 … 255 the value sent in
the application shall be the desired value minus 256. For example: To set a
parameter to 200 it may be needed to set a value of 200 minus 256 = minus
56.
In case of a two byte value the same logic applies: Values greater than 32768
may
needed to be given as negative values too.
Parameter 10: Low Battery Power Level Low battery power level of alarm
threshold values
Low battery power level of alarm threshold values: the value range are 0~50
for percentage, the battery low power level can setting 0%~50%.
Size: 1 Byte, Default Value: 10
SettingDescription
0 – 50 | Low battery power level of alarm threshold values |
---|
Parameter 13: Setup the wait time of PIR for clear the motion.
Setup the wait time of PIR for clear the motion.Valid values:5~15300
seconds.
Size: 2 Byte, Default Value: 30
SettingDescription
5 – 15300 | Setup the wait time of PIR for clear the motion. |
---|
Parameter 14: When the Motion Sensor is triggered, if this parameter is
0x01 then it will send Basic set command to group 1.
When the Motion Sensor is triggered, if this parameter is 0x01 then it will
send Basic set command to group 1.0 = Don’t send.1 = Send.
Size: 1 Byte, Default Value: 0
SettingDescription
0 – 1| When the Motion Sensor is triggered, if this parameter is 0x01 then it
will send Basic set command to group 1.
---|---
Parameter 15: PIR triggers the correspondence between the value of the
Basic set and the PIR state.
PIR triggers the correspondence between the value of the Basic set and the
PIR state.-If this value is 0x00 :PIR triggers send the basic set with 0xFF,
PIR alarm release send the basic set with 0x00.-If this value is 0x01 :PIR
triggers send the basic set with 0x00, PIR alarm release send the basic set
with 0xFF.Only support 0x00 and 0x01 values as valid value.
Size: 1 Byte, Default Value: 0
SettingDescription
0| PIR triggers send the basic set with 0xFF, PIR alarm release send the basic
set with 0x00.
---|---
1| PIR triggers send the basic set with 0x00, PIR alarm release send the basic
set with 0xFF.
Parameter 16: PIR triggers the correspondence between the value of the
Basic set and the PIR stateMotion detection sensitivity level is a value between 1 and 10.
Motion detection sensitivity level is a value between 1 and 10. This value
affects the amount of motion energy required to generate a motion event and
also affects the detection range and angle.1 = Lowest Motion Sensitivity
Size: 1 Byte, Default Value: 9
SettingDescription
0 – 10| Motion detection sensitivity level is a value between 1 and 10. 1 =
Lowest Motion Sensitivity, 10 = Highest Motion Sensitivity
---|---
Parameter 17: Enable/disable pet immunity mode.
Enable/disable pet immunity mode. This feature is lens dependent and
detection range may be reduced when Pet Immunity is enabled.0 = Disable the
pet immunity mode1 = Enable the pet immunity mode
Size: 1 Byte, Default Value: 1
SettingDescription
0 – 1| Enable/disable pet immunity mode.0 = Disable the pet immunity mode,1 =
Enable the pet immunity mode
---|---
Technical Data
Hardware Platform | ZM5101 |
---|---|
Device Type | Notification Sensor |
Network Operation | Reporting Sleeping Slave |
Firmware Version | HW: 1 FW: 2.00 |
Z-Wave Version | 6.81.04 |
Certification ID | ZC10-19056522 |
Z-Wave Product Id | 0x0300.0x0300.0x0026 |
Sensors | LuminanceMotion/No Motion (Binary) |
Supported Notification Types | Luminance |
Firmware Updatable | Updatable by Consumer by RF |
Security V2 | S2_UNAUTHENTICATED |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |
Supported Command Classes
- Association Grp Info
- Association V2
- Battery
- Configuration
- Device Reset Locally
- Firmware Update Md V4
- Manufacturer Specific V2
- Notification V8
- Powerlevel
- Security
- Security 2
- Sensor Multilevel V5
- Supervision
- Transport Service V2
- Version V3
- Wake Up V2
- Zwaveplus Info V2
Controlled Command Classes
- Basic
Explanation of Z-Wave specific terms
-
Controller — is a Z-Wave device with capabilities to manage the network.
Controllers are typically Gateways,Remote Controls or battery operated wall controllers. -
Slave — is a Z-Wave device without capabilities to manage the network.
Slaves can be sensors, actuators and even remote controls. -
Primary Controller — is the central organizer of the network. It must be
a controller. There can be only one primary controller in a Z-Wave network. -
Inclusion — is the process of adding new Z-Wave devices into a network.
-
Exclusion — is the process of removing Z-Wave devices from the network.
-
Association — is a control relationship between a controlling device and
a controlled device. -
Wakeup Notification — is a special wireless message issued by a Z-Wave
device to announces that is able to communicate. -
Node Information Frame — is a special wireless message issued by a
Z-Wave device to announce its capabilities and functions.