Leedarson Lighting HDA11FWB Dimmer Instruction Manual
- June 5, 2024
- Leedarson Lighting
Table of Contents
WARNING:
- This product is to be installed or used in accordance with electrical codes and regulations.
- For indoor use only. Do not use in wet locations.
- If you are unsure any part of these instructions, consult an electrician.
- Save this instructions sheet. It contains important technical data along with testing and troubleshooting information which will be useful after installation is complete.
- This dimmer are not compatible with standard 3-way or 4-way.
- Do not disassemble the product, or make repairs yourself. You run the risk of electric shock and voiding the limited warranty. If you need service, please contact the after sales services.
- The load power rating limit of the device as below Specification sheet, do not exceed the limit.
Package Contents
Smart dimmer 1
Quick start guide1
Accessories package*1
Product Description
The dimmer turns your light smart by enabling you to control them through the smart home APP on your phone at or away from home.
Specification
Model number | HDA11FWB |
---|---|
Power supply: | 120V~, 60Hz |
Maximum Load: | Incandescent 200W, CFL/LED 100W |
Operational temperature: | 0-40°C |
Storage Temperature Range | -20-60°C |
Humidity | 0-85%,non condensing |
Radio protocol: | 2.4G, IEEE 802.11b/g/n |
Range: | About 40m indoors (depending on building materials) |
Feature list
Function | Description |
---|---|
Preset | Double-click the dim-up button(interval is less than 500ms), |
turn on preset scene, default brightest light (user can set the scene by App)
Remote Control| Turn your light on and off from anywhere using the
mobile app.
Schedule| Set specific times for your light to turn on/off as setting
connected lighting turn on at 19:00 every Monday. Or like setting lights to
come on at dusk or turn off at sunrise.
Countdown| Set a countdown timer to have switch turn off automatically.
As setting after 30 minutes turn off automatically.
Delay Off| Double-click the Off button (interval is less than 500ms),
delay of the lamp. The delay time can be set in the App. If it is not set, the
factory default is delay the switch off for 5min.
Take the latest user operation as the highest priority, and close the delay-
off function at the same time.
Timer| Set a timer to have switch turn on or off automatically. As
setting after 30 minutes turn on automatically.
Power Memory| Re-Power, switch restore the state that before power off.
Installing dimmer by itself or with multi-gang
If installing the dimmer in a single gang application, proceed with
Product install introduction. If installing the dimmer in a multi-gang application, proceed with follow:
Multi-gang application
In multi-dimmer installations, the reduction of the dimmer’s capacity may be
required. Refer to the chart for maximum load per dimmer.
Note: No derating is required for LED or CFL bulb applications.
Maximum Load Per Dimmer for Multi-gang
Load| Single| Two-Gang| Three-Gang
incand| 200W| 100W| 100W
Product install introduction
-
Turn power off at the circuit breaker
-
Remove the existing dimmer and connect the new dimmer as follow
-
Mount the dimmer using the screws and attach faceplate.
-
Turn power ON at circuit breaker
-
Quick start guide
Step 1:
Download the Linkind App on App Store or Google Play.
Step 2:
Create an account and sign in.
Step 3:
• Ensure the dimmer is properly wired and power is applied
• Upon initial power-up the LED indicator will green and orange scrolling blinking to show the accessory is ready to configured
• If the LED indicator is no longer green and orange scrolling blinking when you are ready to add the accessory, press “Dim-up” and “Dim-down” button for 5 seconds until the LED indicator keeps in red and release the button
• Press `+’ button to add the device.
Step 4:
Follow the instructions on App.
LED Indicator
Under normal working state. LED indicator is solid green– turn on or dimming, LED indicator is off –Turn off.
Status | Behavior |
---|---|
Green and Orange scrolling blinking | To be configured status. |
Quick Blinking Orange | Connecting to the network |
Solid Green | Connected to the network |
The smart dimmer is turned on or dimming
Solid Red| Connected failed.
Off| The smart dimmer is turned off
The smart dimmer is not configured
Triple Blink Orange| When the countdown starts, triple blink orange, and light
on or off LED indicator according to the actual situation
Connect to the network
Status | Behavior |
---|---|
To be configured status | LED indicator green and orange scrolling blinking. |
Remark: Powering on switch, is ready to start switch network
configuration
Connecting to the network| LED indicator quick blinking orange statue.
Connected to the network| LED indicator keeps in green status for 3s and then
turns off. If switch is not turned on.
Connected failed.| LED indicator keeps in red status for 3s and then turns
off.
Remark: while connected failed, led indicator turn off, to reset the
smart switch to factory settings.
Factory default (reset)| Hold “Dim-up” and “Dim-down” button for a total 5
seconds, and LED indicator keeps in red status, release the button and it will
reset. After a total 5 seconds, switch get into to be configured statue.
Troubleshooting
Problems | Possible cause and action |
---|---|
LEDs do not dim, have poor dimming range, or they flicker/buzz. | Lamp is not |
compatible with the dimmer
Please check from the official website to see if the load is an officially
declared compatible lamp.
Lights Flickering| Lamp has a bad connection
Wires not secured firmly under terminal screws of switch
Light does not turn ON and LED indicator does not turn ON| Circuit breaker or
fuse has tripped.
Lamp is burned out.
Lamp Neutral connection is not wired.
Light can be turn ON and LED indicator does not turn ON| The dimmer have not
be configured, reset dimmer and connect into network.
Remote does not operate lights| Confirm dimmer is connected to the network
Ensure wiring is correct
FCC Statement
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
- This device may not cause harmful interference.
- This device must accept any interference received, including interference that may cause undesired operation.
Note: The grantee is not responsible for any changes or modifications not expressly approved by the party responsible for compliance. Such modifications could void the user’s authority to operate the equipment.
Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help
RF Exposure Statement
This equipment complies with FCC radiation exposure limits set forth for an
uncontrolled environment. This equipment should be installed and operated with
minimum distance of 20 cm between the radiator and your body.