H3R PERFORMANCE Fire Extinguisher Owner’s Manual
- June 17, 2024
- H3R PERFORMANCE
Table of Contents
OWNER’S MANUAL
FOR HAND PORTABLE FIRE
EXTINGUISHERS
Above image shows optional mounting accessories sold separately
INTRODUCTION
Anyone who might be expected to use this fire extinguisher should study and
under stand the information in this manual.
Please read it completely and keep it acces sible so that it may be reviewed
on a periodic basis. OSHA requires training of personnel who might be expected
to use an extinguisher in the case of an emer gency. Familiarity with this
manual and the instruction nameplate on the extinguisher will contribute to
successful use of the extinguisher. You should know just what it CAN and
CANNOT do, where it is located, how to use it and how to maintain it. Proper
and effective use of any fire extinguisher begins with an understanding of the
classes of fire. Different types are tested and rated for certain classes and
sizes of fires. Some are rated for a single classification, some for multiple
classifications and others consti tute a hazard if used incorrectly or on a
type of fire for which it is not suited.
CLASSES OF FIRES | TYPES OF FIRES | PICTURE SYMBOL |
---|---|---|
A | Wood, paper, cloth, trash and other | |
ordinary materials. | ||
b | Gasoline, oil, paint and other flammable liquids. | |
c | May be used on fires involving live electrical equipment without danger to | |
the operator. | ||
d | Combustible metals and combustible metal alloys. | |
k | Cooking media (Vegetable or Animal Oils and Fats) |
IMPORTANT THINGS TO REMEMBER!
NEVER DISCHARGE A FIRE EXTINGUISHER INTO ANYONE’S FACE
NEVER THROW AN EXTINGUISHER INTO A FIRE OR LEAVE THE EXTINGUISHER UNAT TENDED
IF A FIRE IS NOT OUT
(Pressure build-up from excessive heat could cause an explosion from even a
partially full extinguisher)
KEEP FIRE EXTINGUISHERS AWAY FROM CHILDREN
MOUNTING OPTIONS
Our 1 lb. to 5 lb. HalGuard™ and MaxOut™ extinguishers come standard with
steel mounting brackets. Other mounting options are also avail able.
ProLock quick-release brackets
Precision machined from billet aluminum, ProLock brackets provide an
exceptionally secure, rattle-free mounting solution for our 1 Ib., 1.4 Ib. and
2.5 Ib. extinguishers. With both flat surface and roll bar options, ProLock
brackets will keep your extinguisher secure even in the most demanding
applications.
Extreme Duty quick-release brackets
Available for 2.5 Ib. and 5.0 Ib. fire extinguishers, our NHRA accepted
brackets allow for fast action while withstanding rigorous use. Fiberglass-
reinforced nylon brackets attach to flat surfaces or 15/8″& 1 3/4” roll bars.
This patented design is tested to inertia loads in excess of 27G. Compli- ant
with MIL-STD-810G standard.
Seat Mount
Our NHRA accepted fire extinguisher seat mount installs easily into most
vehicles, attaching to the seat rail bolts or above the slider of the driver
or front passenger seats. Not only does this put the extinguisher at your
fingertips, it also avoids the need to drill mounting holes into your vehicle.
This patented design accepts H3R Performance standard brackets and available
ProLock and Extreme Duty brackets.
MaxOut” (Dry Chemical) and HalGuard” (Halotron I) Fire Extinguishers
These extinguishers are shipped factory charged. Do not test your extinguisher
since even a small amount of discharge could cause it to lose pressure making
it less effective or useless in case of a fire.
Dry Chemicals are non-poisonous but either the acidic based (ABC) or alkaline
based (Purple K) chemicals could be an irritant if inhaled. If any physical
discomfort is experienced, contact a physician immediately.
Halotron I should not be used in confined areas smaller than indicated on the
extinguisher nameplate, food preparation areas or in the presence of people
with cardiac problems. If problems occur, quickly remove the person from the
area where the gas is present, initiate artificial respiration and transport
to a physician.
Dry Chemical is not recommended for fires in electrical equipment or aircraft.
Use of these agents may extinguish the fire but damage the equipment.
Never use ABC dry chemical or Halotron I fire extinguishers on fires involving
chlorine containing oxidizers (example: pool chemicals). A violent explosive
reaction could occur with the mixture of chemicals.
NOTE : As required by OSHA, Safety Data Sheets (SOS) are available for
all chemicals contained in these fire extinguishers. Contact H3R Performance,
Inc., or your H3R Performance distributor. SOS information is also included on
our extinguisher name plates.
MONTHLY INSPECTION RECORD
FASTEN TO EXTINGUISHER BEFORE INSTALLATION
DO NOT REMOVE
FOLLOW THE INSPECTION INSTRUCTIONS IN OWNER’S MANUAL AND ON THE
EXTINGUISHER
Date | Inspected by | Condition |
---|---|---|
HAVE YOUR EXINGUISHER PROFESSIONALLY MAINTAINED AND RECHARGED
RECHARGE AFTER ANY USE
NOTICE TO BOAT OWNERS
If the extinguisher is to be mounted in your boat, make sure that the proper
mounting bracket is used. The nameplate (in the area of the UL manifest) says
if it is Coast Guard approved and the mounting bracket which MUST be used to
complete the approval. The Coast Guard will cite you if the correct type of
extinguisher and bracket has not been installed.
INSPECTION RECORD
Model No.:
Serial No.:
Mfg. Date:
Date Installed New:
INSPECTION
should be performed monthly or more frequently if circumstances dictate. The
extinguisher should be checked to see that it is not damaged, the discharge
outlet is not blocked, that it is fully charged, the seal is not
broken and that the operating instructions are clearly visible.
ANNUAL MAINTENANCE is a more complete inspection of the extinguisher and
should be done professionally. It will reveal the need for hydro testing which
must be done on Dry Chemical and HalotronI extinguishers every
TWELVE YEARS. Most local authorities require special tags be attached to the
extinguisher to verify this service.
SIX YEAR MAINTENANCE – Every six years, extinguishers requiring a 12 year
hydro test shall be emptied and subject to thorough examiner- tion of:
mechanical parts, extinguishing agent and expelling means. When applicable
mainte- nance procedures are done during periodic recharging or hydro testing,
the six-year require- ment will begin from that date.
RECHARGE should be done professionally immediately after any use by your local
fire service company who has the trained personnel, extinguishing agents and
equipment to do it properly. This extinguisher must be recharged with the
extinguishing agent specified on the nameplate. Substitutions could cause
damage or injury and will void the warranty.
DISTRIBUTED BY:
INSTALLATION
Install, inspect, maintain and test your fire extinguisher in accordance with
the National Fire Protection Assoc. Standard No. 10 “Portable Fire
Extinguishers.”
Your fire extinguisher should be mounted in a clean, dry area, accessible to
possible fire hazards and preferably near an exit if mounted in a building.
Use the mounting bracket furnished with the extinguisher or another approved
H3R Perfor mance vehicle bracket. Fasten to a solid surface using strong
fasteners (not included).
INSPECTION
Your extinguisher should be inspected monthly, checking for any possible
damage, corrosion, leakage or obstructions in the discharge outlet.
The tamper seal should be unbroken. The extinguisher should be cleaned so that
the instructions on the label are clearly visible.
Extinguisher pressure gauges should be checked. The indicator will vary
slightly due to temperature but should always be in the Green area if it is
fully pressurized. Weigh the extinguisher to affirm that the full weight is
within the tolerances stated on the nameplate.
IN CASE OF FIRE
- Have everyone immediately evacuate the area.
- Call the Fire Dept. even if the fire appears to be small (small fires quickly become LARGE fires).
- Use your fire extinguisher according to the instructions on the nameplate and in this manual. Professionals should fight a large fire. Be prepared to leave the area if the fire cannot be immediately controlled.
HOWTOUSE
Note:The following instructions are of a general nature, intended to familiarize the user with the basic operating techniques of H3R Performance hand portable extinguishers. All of them operate by removing the ring (safety) pin and squeezing the handles together. Since extinguishers differ, the extinguisher nameplate must be consulted for specific procedures and starting distances.
- HOLD THE EXTINGUISHER UPRIGHT, TWIST AND PULL THE RING (SAFETY) PIN breaking the plastic seal.
- STAND BACK FROM THE FIRE (the minimum distance stated on the nameplate) and AIM AT THE BASE OF THE FIRE NEAREST YOU.
- Keeping the extinguisher UPRIGHT, SQUEEZE THE HANDLES TOGETHER to discharge and SWEEP FROM SIDE TO SIDE. Move closer as the fire is extinguished but not so close as to scatter the burning material or liquid.
- When the fire is out, back away while watching for possible re-ignition.
- Evacuate and ventilate the area immediately after use. The fumes and smoke from any fire may be hazardous and can be deadly.
Note : WHENEVER POSSIBLE, PROTECTIVE CLOTHING AND BREATHING EQUIPMENT SHOULD BE USED WHILE FIGHTING A FIRE.
- HOLD UPRIGHT TWIST & PULL RINPIN
- STAND BACK FROM THE FIRE AND AIM AT THE BASE OF THE FIRE NEAREST YOU
- SQUEEZE HANDLES TOGETHER AND SWEEP THE EXTINGUISHER STREAM SIDE TO SIDE
H3R PERFORMANCE LIMITED WARRANTY
H3R Performance, Inc. warrants MaxOut™ and HalGuard™ fire extinguishers for a
period of six (6) years from the date of purchase to be free from defects in
material and workman ship. During the warranty period, any such defects will
be repaired or the defective extinguisher replaced IF ONLY FACTORY REPLACEMENT
PARTS HAVE BEEN USED TO SERVICE THE EXTINGUISHER. This warranty does not cover
defects resulting from modification, alteration, misuse, exposure to
corrosive conditions, improper installation or maintenance.
This warranty does not cover products sold by unauthorized distributors on 3rd
party marketing platforms such as Amazon, eBay and Walmart. ALL IMPLIED
WARRANTIES, INCLUDING, BUT NOT LIMITED TO, WARRANTIES OF FITNESS FOR PURPOSE
AND MERCHANTABILITY, ARE LIMITED TO THE TIME PERIODS STATED ABOVE. IN NO EVENT
SHALL H3R PERFORMANCE, INC. BE LIABLE TO INCIDENTAL OR CONSEQUENTIAL DAMAGES.
Some states do not allow limitations on how long an implied warranty lasts or
the exclusion or limitation of incidental or consequential damages, so the
above limitations or exclusions may not apply to you. H3R Performance, Inc.
neither assumes nor authorizes any representative or other person to assume
for it, any obligation or liability other than as expressly set forth herein.
This warranty gives you specific legal right and you may have other rights
which vary from state to state.To obtain performance of the obligation of this
warranty, contact us at
h3rinfo@h3rperformance.com.
H3R Performance, Inc.
103 H Street, Suite A
Petaluma, CA 94952
Tel800-249-4289 ] Fax
707-765-3395
h3rinfo@h3rperformance.com
h3rperformance.com