Climax Technology Shutter Control SCM-2ZW Manual Shutter Control

October 28, 2023
Climax Technology

Climax Technology

Shutter Control

SKU: SCM-2ZW

Quickstart

This is a
secure
Window Covering – Pos/End Aware
for
CEPT (Europe)
.

To run this device please connect it to your mains power supply.

To add this device to your network execute the following action:
This product can be included and operated in any Z-Wave network with other Z-Wave certified devices from other manufactures and/or other applications. All non-battery operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network.1. Connect the power to Shutter Control (see manuals Installation).2. Put the Z-Wave gateway or control panel into Inclusion mode (please refer to the Z-Wave gateway or control panel manual).3. Within 1.5 seconds, press the Function Button 3 times.4. Refer to the operation manual of the Z-Wave gateway or control panel to complete the adding process.5. If the device has already been added (included) into another Z-Wave Gateway/Control Panel, or if the device is unable to be added into the current Z-Wave Gateway/Control Panel, try removing it first (see Removing Device).

Please refer to the
Manufacturers Manual
for more information.

Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law.
The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material.
Use this equipment only for its intended purpose. Follow the disposal instructions.

Do not dispose of electronic equipment or batteries in a fire or near open heat sources.

What is Z-Wave?

Z-Wave is the international wireless protocol for communication in the Smart Home. This
device is suited for use in the region mentioned in the Quickstart section.

Z-Wave ensures a reliable communication by reconfirming every message ( two- way
communication
) and every mains powered node can act as a repeater for other nodes
( meshed network ) in case the receiver is not in direct wireless range of the
transmitter.

This device and every other certified Z-Wave device can be used together with any other
certified Z-Wave device regardless of brand and origin
as long as both are suited for the
same frequency range.

If a device supports secure communication it will communicate with other devices
secure as long as this device provides the same or a higher level of security.
Otherwise it will automatically turn into a lower level of security to maintain
backward compatibility.

For more information about Z-Wave technology, devices, white papers etc. please refer
to www.z-wave.info.

Product Description

The SCM-2ZW is a Z-Wave roller shutter control that provides remote operation of roller shutters for home automation and security purposes. Automatically or remotely roll up, down or stop mid-way, the SCM-2ZW is directly connected to and controls motorized window treatments, interior and exterior shades and blinds, projection screen, and garage door or driveway gate of your home.With SCM-2ZW, all roller shutters in the house can be configured to automatically open or close according to preset schedules and scenarios.

Prepare for Installation / Reset

Please read the user manual before installing the product.

In order to include (add) a Z-Wave device to a network it must be in factory default
state.
Please make sure to reset the device into factory default. You can do this by
performing an Exclusion operation as described below in the manual. Every Z-Wave
controller is able to perform this operation however it is recommended to use the primary
controller of the previous network to make sure the very device is excluded properly
from this network.

Reset to factory default

This device also allows to be reset without any involvement of a Z-Wave controller. This
procedure should only be used when the primary controller is inoperable.

(Only use factory reset when network Control Panel/Gateway is missing or inoperable).Factory resetting the device will restore it to factory default settings (i.e. excluded from Z-Wave network).Please use the reset procedure only when the primary controller is missing or inoperable.Press and hold the Function Button of the device for 10 seconds to factory reset.

Safety Warning for Mains Powered Devices

ATTENTION: only authorized technicians under consideration of the country- specific
installation guidelines/norms may do works with mains power. Prior to the assembly of
the product, the voltage network has to be switched off and ensured against re-switching.

Inclusion/Exclusion

On factory default the device does not belong to any Z-Wave network. The device needs
to be added to an existing wireless network to communicate with the devices of this network.
This process is called Inclusion.

Devices can also be removed from a network. This process is called Exclusion.
Both processes are initiated by the primary controller of the Z-Wave network. This
controller is turned into exclusion respective inclusion mode. Inclusion and Exclusion is
then performed doing a special manual action right on the device.

Inclusion

This product can be included and operated in any Z-Wave network with other Z-Wave certified devices from other manufactures and/or other applications. All non-battery operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network.1. Connect the power to Shutter Control (see manuals Installation).2. Put the Z-Wave gateway or control panel into Inclusion mode (please refer to the Z-Wave gateway or control panel manual).3. Within 1.5 seconds, press the Function Button 3 times.4. Refer to the operation manual of the Z-Wave gateway or control panel to complete the adding process.5. If the device has already been added (included) into another Z-Wave Gateway/Control Panel, or if the device is unable to be added into the current Z-Wave Gateway/Control Panel, try removing it first (see Removing Device).

Exclusion

The device must be removed from existing Z-Wave network before being added into another.1. Put the Z-Wave gateway or control panel into Exclusion mode (please refer to the Z-Wave gateway or control panel manual).2. Within 1.5 seconds, press the Function Button 3 times and the device will be removed from the Z-Wave network.

Quick trouble shooting

Here are a few hints for network installation if things dont work as expected.

  1. Make sure a device is in factory reset state before including. In doubt exclude before include.
  2. If inclusion still fails, check if both devices use the same frequency.
  3. Remove all dead devices from associations. Otherwise you will see severe delays.
  4. Never use sleeping battery devices without a central controller.
  5. Dont poll FLIRS devices.
  6. Make sure to have enough mains powered device to benefit from the meshing

Association – one device controls an other device

Z-Wave devices control other Z-Wave devices. The relationship between one device
controlling another device is called association. In order to control a different
device, the controlling device needs to maintain a list of devices that will receive
controlling commands. These lists are called association groups and they are always
related to certain events (e.g. button pressed, sensor triggers, …). In case
the event happens all devices stored in the respective association group will
receive the same wireless command wireless command, typically a ‘Basic Set’ Command.

Association Groups:

Group NumberMaximum NodesDescription

1| 1| Z-Wave Plus LifelineSwitch MultilevelCC,V4(COMMAND_CLASS_SWITCH_MULTILEVEL)Device Reset Locally CC, V4 (COMMAND_CLASS_DEVICE_RESET_LOCALLY)When SCM changes its position: [SWITCH_MULTILEVEL_REPORT]
---|---|---

Configuration Parameters

Z-Wave products are supposed to work out of the box after inclusion, however
certain configuration can adapt the function better to user needs or unlock further
enhanced features.

IMPORTANT: Controllers may only allow configuring
signed values. In order to set values in the range 128 … 255 the value sent in
the application shall be the desired value minus 256. For example: To set a
parameter to 200 it may be needed to set a value of 200 minus 256 = minus 56.
In case of a two byte value the same logic applies: Values greater than 32768 may
needed to be given as negative values too.

Parameter 1: Up Time Setting

For parameter 1, users can set the open time (from down to up) to a value that ranges from 0 to 255 seconds.
Size: 2 Byte, Default Value: 240

SettingDescription

0 – 255 The ranges from 0 to 255 seconds.

Parameter 2: Close Time Setting

For parameter 2, users can set the close time (from up to down) time to a value that ranges from 0 to 255 seconds.
Size: 2 Byte, Default Value: 240

SettingDescription

0 – 255 The ranges from 0 to 255 seconds.

Parameter 3: Current Position

For parameter 3, users can set the current position to a value that ranges from 0% to 99%.
Size: 2 Byte, Default Value: 99

SettingDescription

0 – 99 The ranges from 0% to 99%.

Technical Data

Hardware Platform ZM5202
Device Type Window Covering – Pos/End Aware
Network Operation Always On Slave
Firmware Version HW: 255 FW: 4.01
Z-Wave Version 6.81.01
Certification ID ZC10-19036397
Z-Wave Product Id 0x018E.0x0004.0x0005
Window Covering Control Features Supports Up/Down Motion
Firmware Updatable Updatable by Consumer by RF
Security V2 S2_UNAUTHENTICATED
Frequency XXfrequency
Maximum transmission power XXantenna

Supported Command Classes

  • Association Grp Info
  • Association V2
  • Basic V2
  • Configuration
  • Device Reset Locally
  • Firmware Update Md V4
  • Manufacturer Specific V2
  • Multi Channel Association V3
  • Powerlevel
  • Security 2
  • Supervision
  • Switch Binary
  • Switch Multilevel V4
  • Transport Service V2
  • Version V3
  • Zwaveplus Info V2

Explanation of Z-Wave specific terms

  • Controller — is a Z-Wave device with capabilities to manage the network.
    Controllers are typically Gateways,Remote Controls or battery operated wall controllers.

  • Slave — is a Z-Wave device without capabilities to manage the network.
    Slaves can be sensors, actuators and even remote controls.

  • Primary Controller — is the central organizer of the network. It must be
    a controller. There can be only one primary controller in a Z-Wave network.

  • Inclusion — is the process of adding new Z-Wave devices into a network.

  • Exclusion — is the process of removing Z-Wave devices from the network.

  • Association — is a control relationship between a controlling device and
    a controlled device.

  • Wakeup Notification — is a special wireless message issued by a Z-Wave
    device to announces that is able to communicate.

  • Node Information Frame — is a special wireless message issued by a
    Z-Wave device to announce its capabilities and functions.

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Climax Technology User Manuals

Related Manuals