Climax Technology Clamp Meter CLMT-1ZW Manual Clamp Meter

October 28, 2023
Climax Technology

Climax Technology

Clamp Meter

SKU: CLMT-1ZW

Quickstart

This is a ****

Energy Meter
for
CEPT (Europe)
.

To run this device please connect it to your mains power supply.

To add this device to your network execute the following action:
This product can be included and operated in any Z-Wave network with other Z-Wave certified devices from other manufactures and/or other applications. All non-battery operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network. -Plug in the AC Input cable into the socket to power on the ClampMeter. -Put the Control Panel into Inclusion mode (please refer to the Z- Wave control panel manual). -Within 1.5 seconds, press the Function Button 3 times. -Refer to the operation manual of Z-Wave Gateway or Control Panelto complete the adding process. -If the device has already been added (included) into another Z-Wave Gateway/Control Panel, or if the device is unable to be added into the current Z-Wave Gateway/Control Panel, try removing it first (see Removing Device).

Please refer to the
Manufacturers Manual
for more information.

Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law.
The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material.
Use this equipment only for its intended purpose. Follow the disposal instructions.

Do not dispose of electronic equipment or batteries in a fire or near open heat sources.

What is Z-Wave?

Z-Wave is the international wireless protocol for communication in the Smart Home. This
device is suited for use in the region mentioned in the Quickstart section.

Z-Wave ensures a reliable communication by reconfirming every message ( two- way
communication
) and every mains powered node can act as a repeater for other nodes
( meshed network ) in case the receiver is not in direct wireless range of the
transmitter.

This device and every other certified Z-Wave device can be used together with any other
certified Z-Wave device regardless of brand and origin
as long as both are suited for the
same frequency range.

If a device supports secure communication it will communicate with other devices
secure as long as this device provides the same or a higher level of security.
Otherwise it will automatically turn into a lower level of security to maintain
backward compatibility.

For more information about Z-Wave technology, devices, white papers etc. please refer
to www.z-wave.info.

Product Description

CL Meter is an energy metering device designed to measure, monitor, and report the energy consumption of an entire household or apartment building directly from the electric box or breaker panel, for users to look for energy-saving opportunities or provide tenant-specific billing. Installed directly in the homes main circuit box, with the clamps attached to it, the CLMT-1ZW will monitor the total amount of electricity the entire home uses with accuracy and speed. With the CL Meter, users can easily track their power usage, allowing them to make the most out of reducing energy consumption and achieving greater energy efficiency.

Prepare for Installation / Reset

Please read the user manual before installing the product.

In order to include (add) a Z-Wave device to a network it must be in factory default
state.
Please make sure to reset the device into factory default. You can do this by
performing an Exclusion operation as described below in the manual. Every Z-Wave
controller is able to perform this operation however it is recommended to use the primary
controller of the previous network to make sure the very device is excluded properly
from this network.

Reset to factory default

This device also allows to be reset without any involvement of a Z-Wave controller. This
procedure should only be used when the primary controller is inoperable.

Factory resetting the device will restore it to factory default settings (i.e. not included into any Z-Wave network). Please only use this procedure if the Z-Wave Gateway or Control Panel is lost or otherwise inoperable. -Press and hold the Function Button of the device for 10 seconds to factory reset.

Safety Warning for Mains Powered Devices

ATTENTION: only authorized technicians under consideration of the country- specific
installation guidelines/norms may do works with mains power. Prior to the assembly of
the product, the voltage network has to be switched off and ensured against re-switching.

Inclusion/Exclusion

On factory default the device does not belong to any Z-Wave network. The device needs
to be added to an existing wireless network to communicate with the devices of this network.
This process is called Inclusion.

Devices can also be removed from a network. This process is called Exclusion.
Both processes are initiated by the primary controller of the Z-Wave network. This
controller is turned into exclusion respective inclusion mode. Inclusion and Exclusion is
then performed doing a special manual action right on the device.

Inclusion

This product can be included and operated in any Z-Wave network with other Z-Wave certified devices from other manufactures and/or other applications. All non-battery operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network. -Plug in the AC Input cable into the socket to power on the ClampMeter. -Put the Control Panel into Inclusion mode (please refer to the Z- Wave control panel manual). -Within 1.5 seconds, press the Function Button 3 times. -Refer to the operation manual of Z-Wave Gateway or Control Panelto complete the adding process. -If the device has already been added (included) into another Z-Wave Gateway/Control Panel, or if the device is unable to be added into the current Z-Wave Gateway/Control Panel, try removing it first (see Removing Device).

Exclusion

The device must be removed from existing Z-Wave network before being added into another.Exclusion Mode -Put the Z-Wave Gateway or Control Panel into Exclusion mode (please refer to the Z-Wave or control panel manual). -Within 1.5 seconds, press the Function Button 3 times and the device will be removed from the Z-Wave network.

Quick trouble shooting

Here are a few hints for network installation if things dont work as expected.

  1. Make sure a device is in factory reset state before including. In doubt exclude before include.
  2. If inclusion still fails, check if both devices use the same frequency.
  3. Remove all dead devices from associations. Otherwise you will see severe delays.
  4. Never use sleeping battery devices without a central controller.
  5. Dont poll FLIRS devices.
  6. Make sure to have enough mains powered device to benefit from the meshing

Association – one device controls an other device

Z-Wave devices control other Z-Wave devices. The relationship between one device
controlling another device is called association. In order to control a different
device, the controlling device needs to maintain a list of devices that will receive
controlling commands. These lists are called association groups and they are always
related to certain events (e.g. button pressed, sensor triggers, …). In case
the event happens all devices stored in the respective association group will
receive the same wireless command wireless command, typically a ‘Basic Set’ Command.

Association Groups:

Group NumberMaximum NodesDescription

1| 1| Group 1 for LifeLine: (maximum node:1)Device Reset Locally CC, V2 Meter CC, V2For group 1, the Clamp Meter will report:(1) The sum of instant Power Consumption (Watt) read fromCT1 and CT2(2) The sum of accumulated Power Consumption (KWh) readfrom CT1 and CT2
---|---|---
2| 1| Group 2 for meter CT1 (maximum node: 1)Meter CC, V2For group 2, the Switch will report: (1) Instant Power Consumption (Watt) read from CT1 (2) Accumulated Power Consumption (KWh) read from CT1
3| 1| Group 3 for meter CT2: (maximum node: 1)Meter CC, V2For group 3, the Switch will report(1) The sum of instant Power Consumption (Watt) read from CT2(2) The sum of accumulated Power Consumption (KWh) read from CT2

Technical Data

Hardware Platform ZM5202
Device Type Whole Home Meter – Simple
Network Operation Always On Slave
Firmware Version HW: 255 FW: 1.29
Z-Wave Version 6.61.00
Certification ID ZC10-17035457
Z-Wave Product Id 0x018E.0x0004.0x001D
Firmware Updatable Updatable by Professional/Technician
Color White
Supported Meter Type Electric Energy
Frequency XXfrequency
Maximum transmission power XXantenna

Supported Command Classes

  • Association Grp Info V2
  • Association V2
  • Crc 16 Encap
  • Device Reset Locally
  • Firmware Update Md V2
  • Manufacturer Specific V2
  • Meter V2
  • Multi Channel Association V3
  • Multi Channel V4
  • Powerlevel
  • Version V2
  • Zwaveplus Info V2

Explanation of Z-Wave specific terms

  • Controller — is a Z-Wave device with capabilities to manage the network.
    Controllers are typically Gateways,Remote Controls or battery operated wall controllers.

  • Slave — is a Z-Wave device without capabilities to manage the network.
    Slaves can be sensors, actuators and even remote controls.

  • Primary Controller — is the central organizer of the network. It must be
    a controller. There can be only one primary controller in a Z-Wave network.

  • Inclusion — is the process of adding new Z-Wave devices into a network.

  • Exclusion — is the process of removing Z-Wave devices from the network.

  • Association — is a control relationship between a controlling device and
    a controlled device.

  • Wakeup Notification — is a special wireless message issued by a Z-Wave
    device to announces that is able to communicate.

  • Node Information Frame — is a special wireless message issued by a
    Z-Wave device to announce its capabilities and functions.

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Climax Technology User Manuals

Related Manuals