Philio Technology (Motion Sensor) PST02-5B Manual
- June 8, 2024
- Philio Technology
Table of Contents
- Philio Technology
- (Motion Sensor)
- SKU: PST02-5B
- Quickstart
- Important safety information
- What is Z-Wave?
- Product Description
- Prepare for Installation / Reset
- Inclusion/Exclusion
- Communication to a Sleeping device (Wakeup)
- Quick trouble shooting
- Association – one device controls an other device
- Configuration Parameters
- Parameter 10: Auto Report Battery Time
- Parameter 12: Auto Report Illumination Time
- Parameter 13: Auto Report Temperature Time
- Parameter 2: Basic Set Level
- Parameter 20: Auto Report Tick Interval
- Parameter 21: Temperature Differential Report
- Parameter 22: Illumination Differential Report
- Parameter 3: PIR Sensitivity
- Parameter 4: Light Threshold
- Parameter 5: Operation Mode
- Parameter 6: Mult- Sensor Function Switch
- Parameter 7: Customer Function
- Parameter 8: PIR Re- Detect Interval Time
- Parameter 9: Turn Off Light Time
- Technical Data
- Supported Command Classes
- Controlled Command Classes
- Explanation of Z-Wave specific terms
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Philio Technology
(Motion Sensor)
SKU: PST02-5B
Quickstart
This is a
secure
Alarm Sensor
for
Russia.
Please make sure the internal battery is fully charged.
To add this device to your network execute the following action:
There are two tamper keys in the device, one is in the back side,another is in
the front side. Both of them can add, remove or reset from Z-WaveTM network.1.
Have Z-WaveTM Controller entered inclusion mode.2. Pressing tamper key three
times within 1.5 secondsto enter the inclusion mode.3. After add successful,
the device will wake toreceive the setting command from Z-WaveTMController
about 20 seconds
Please refer to the
Manufacturers
Manual
for more information.
Important safety information
Please read this manual carefully. Failure to follow the recommendations in
this manual may be dangerous or may violate the law.
The manufacturer, importer, distributor and seller shall not be liable for any
loss or damage resulting from failure to comply with the instructions in this
manual or any other material.
Use this equipment only for its intended purpose. Follow the disposal
instructions.
Do not dispose of electronic equipment or batteries in a fire or near open heat sources.
What is Z-Wave?
Z-Wave is the international wireless protocol for communication in the Smart
Home. This
device is suited for use in the region mentioned in the Quickstart section.
Z-Wave ensures a reliable communication by reconfirming every message ( two-
way
communication) and every mains powered node can act as a repeater for other
nodes
( meshed network ) in case the receiver is not in direct wireless range of
the
transmitter.
This device and every other certified Z-Wave device can be used together
with any other
certified Z-Wave device regardless of brand and origin as long as both are
suited for the
same frequency range.
If a device supports secure communication it will communicate with other
devices
secure as long as this device provides the same or a higher level of security.
Otherwise it will automatically turn into a lower level of security to
maintain
backward compatibility.
For more information about Z-Wave technology, devices, white papers etc.
please refer
to www.z-wave.info.
Product Description
The slim multisensorPST02-5B has PIR, temperature and illumination, 3 sensors function in one,based on Z-Wave technologyIt is the Z-WaveTM plus product, it support the security, OTA… Thosenewest features of the Z-WaveTM technology. Z-WaveTM is a wirelesscommunication protocol designed for home automation, specifically toremotely control applications in residential and light commercialenvironments. The technology uses a low-power RF radio embedded orretrofitted into home electronics devices and systems, such as lighting,home access control, entertainment systems and household appliances.
Prepare for Installation / Reset
Please read the user manual before installing the product.
In order to include (add) a Z-Wave device to a network it must be in factory
default
state. Please make sure to reset the device into factory default. You can do
this by
performing an Exclusion operation as described below in the manual. Every
Z-Wave
controller is able to perform this operation however it is recommended to use
the primary
controller of the previous network to make sure the very device is excluded
properly
from this network.
Reset to factory default
This device also allows to be reset without any involvement of a Z-Wave
controller. This
procedure should only be used when the primary controller is inoperable.
1. Pressing tamper key four times within 1.5 secondsand do not release the tamper key in the 4thpressed, and the LED will light ON.2. After 3 seconds the LED will turn OFF, after thatwithin 2 seconds, release the tamper key. Ifsuccessful, the LED will light ON one second.Otherwise, the LED will flash once.3. IDs are excluded and all settings will reset tofactory default.*Please use this procedure only when the network primary controller is missing or otherwise inoperable.
Inclusion/Exclusion
On factory default the device does not belong to any Z-Wave network. The
device needs
to be added to an existing wireless network to communicate with the
devices of this network.
This process is called Inclusion.
Devices can also be removed from a network. This process is called
Exclusion.
Both processes are initiated by the primary controller of the Z-Wave network.
This
controller is turned into exclusion respective inclusion mode. Inclusion and
Exclusion is
then performed doing a special manual action right on the device.
Inclusion
There are two tamper keys in the device, one is in the back side,another is in the front side. Both of them can add, remove or reset from Z-WaveTM network.1. Have Z-WaveTM Controller entered inclusion mode.2. Pressing tamper key three times within 1.5 secondsto enter the inclusion mode.3. After add successful, the device will wake toreceive the setting command from Z-WaveTMController about 20 seconds
Exclusion
There are two tamper keys in the device, one is in the back side,another is in the front side. Both of them can add, remove or reset from Z-WaveTM network.1. Have Z-WaveTM Controller entered exclusion mode.2. Pressing tamper key three times within 1.5 secondsto enter the exclusion mode.Node ID has been excluded.
Communication to a Sleeping device (Wakeup)
This device is battery operated and turned into deep sleep state most of the
time
to save battery life time. Communication with the device is limited. In order
to
communicate with the device, a static controller C is needed in the
network.
This controller will maintain a mailbox for the battery operated devices and
store
commands that can not be received during deep sleep state. Without such a
controller,
communication may become impossible and/or the battery life time is
significantly
decreased.
This device will wakeup regularly and announce the wakeup
state by sending out a so called Wakeup Notification. The controller can then
empty the mailbox. Therefore, the device needs to be configured with the
desired
wakeup interval and the node ID of the controller. If the device was included
by
a static controller this controller will usually perform all necessary
configurations. The wakeup interval is a tradeoff between maximal battery
life time and the desired responses of the device. To wakeup the device please
perform
the following action:
After the device adding to the network, it will wake-up once per day indefault. When it wake-up it will broadcast the Wake Up Notificationmessage to the network, and wake-up 10 seconds for receive thesetting commands.The wake-up interval minimum setting is 30 minutes, and maximumsetting is 120 hours. And the interval step is 30 minutes.If the user want to wake-up the device immediately, please remove thefront cover,and press the tamper key once. The device will wake-up 10seconds.
Quick trouble shooting
Here are a few hints for network installation if things dont work as expected.
- Make sure a device is in factory reset state before including. In doubt exclude before include.
- If inclusion still fails, check if both devices use the same frequency.
- Remove all dead devices from associations. Otherwise you will see severe delays.
- Never use sleeping battery devices without a central controller.
- Dont poll FLIRS devices.
- Make sure to have enough mains powered device to benefit from the meshing
Association – one device controls an other device
Z-Wave devices control other Z-Wave devices. The relationship between one
device
controlling another device is called association. In order to control a
different
device, the controlling device needs to maintain a list of devices that will
receive
controlling commands. These lists are called association groups and they are
always
related to certain events (e.g. button pressed, sensor triggers, …). In case
the event happens all devices stored in the respective association group will
receive the same wireless command wireless command, typically a ‘Basic Set’
Command.
Association Groups:
Group NumberMaximum NodesDescription
1| 8| The group 1 is forreceiving the report message, like triggered
event,temperature, illumination etc.
---|---|---
2| 8| The group 2 is for lightcontrol, the device will send the Basic Set
commandto this group.
Configuration Parameters
Z-Wave products are supposed to work out of the box after inclusion, however
certain configuration can adapt the function better to user needs or unlock
further
enhanced features.
IMPORTANT: Controllers may only allow configuring
signed values. In order to set values in the range 128 … 255 the value sent in
the application shall be the desired value minus 256. For example: To set a
parameter to 200 it may be needed to set a value of 200 minus 256 = minus
56.
In case of a two byte value the same logic applies: Values greater than 32768
may
needed to be given as negative values too.
Parameter 10: Auto Report Battery Time
The interval time for auto report thebattery level.0 means turn off auto
report battery.The default value is 12. The tick timecan setting by the
configuration No.20.
Size: 1 Byte, Default Value: 12
SettingDescription
0 – 127| The interval time for auto report the battery level. 0 means turn off
auto report battery. The default value is 12. The tick time can setting by the
configuration No.20.
---|---
Parameter 12: Auto Report Illumination Time
The interval time for auto report theillumination.0 means turn off auto
reportillumination.The default value is 12. The tick timecan setting by the
configuration No.20.
Size: 1 Byte, Default Value: 12
SettingDescription
0 – 127| The interval time for auto report the illumination. 0 means turn off
auto report illumination. The default value is 12. The tick time can setting
by the configuration No.20.
---|---
Parameter 13: Auto Report Temperature Time
The interval time for auto report thetemperature.0 means turn off auto
reporttemperature.The default value is 12. The tick timecan setting by the
configuration No.20.
Size: 1 Byte, Default Value: 12
SettingDescription
0 – 127| The interval time for auto report the temperature. 0 means turn off
auto report temperature. The default value is 12. The tick time can setting by
the configuration No.20.
---|---
Parameter 2: Basic Set Level
Setting the BASIC command value toturn on the light. The 0xFF(-1) meansturn
on the light. For dimmerequipment 1 to 100 means the lightstrength.0 means
turn off the light.Caution: The value is unsigned byte,the range is from 0x00
~ 0xFF.
Size: 1 Byte, Default Value: -127
SettingDescription
-128 – 127 | Setting the BASIC command value to turn on the light. The 0xFF(-1) means turn on the light. For dimmer equipment 1 to 100 means the light strength. 0 means turn off the light. Caution: The value is unsigned byte, the range is from 0x00 ~ 0xFF. |
---|
Parameter 20: Auto Report Tick Interval
The interval time for auto report eachtick. Setting this configuration
willeffect configuration No.10, No.11,No.12 and No.13.The unit is 1
minute.Caution1: Setting to 0 means turnoff all auto report function.Caution2:
The value is unsignedbyte, the range is from 0x00 ~ 0xFF.
Size: 1 Byte, Default Value: 30
SettingDescription
-128 – 127 | The interval time for auto report each tick. Setting this configuration will effect configuration No.10, No.11, No.12 and No.13. The unit is 1 minute. |
---|
Parameter 21: Temperature Differential Report
The temperature differential to report.0 means turn off this function.The
unit is Fahrenheit.Enable this function the device willdetect every
minutes.And when the temperature is over 140degree Fahrenheit, it will
continuereport.Enable this functionality will causesome issue please see the
detail in theTemperature Report section.
Size: 1 Byte, Default Value: 1
SettingDescription
0 – 127| The temperature differential to report. 0 means turn off this
function. The unit is Fahrenheit. Enable this function the device willdetect
every minutes. And when the temperature is over 140 degree Fahrenheit, it will
continue report. Enable this functionality will cause some issue please see
the detail in the Temperature Report section.
---|---
Parameter 22: Illumination Differential Report
The illumination differential to report.0 means turn off this function.The
unit is percentage.Enable this function the device willdetect every
minutes.Enable this functionality will causesome issue please see the detail
in theIllumination Report section.
Size: 1 Byte, Default Value: 0
SettingDescription
0 – 99| The illumination differential to report. 0 means turn off this
function. The unit is percentage. Enable this function the device will detect
every minutes. Enable this functionality will cause some issue please see the
detail in the Illumination Report section.
---|---
Parameter 3: PIR Sensitivity
PIR sensitivity settings.0 means disable the PIR motion.1 means the lowest
sensitivity,99 means the highest sensitivity.High sensitivity means can
detectedlong distance, but if there is morenoise signal in the environment, it
willre-trigger too frequency.
Size: 1 Byte, Default Value: 80
SettingDescription
0 – 99| PIR sensitivity settings. 0 means disable the PIR motion. 1 means the
lowest sensitivity, 99 means the highest sensitivity. High sensitivity means
can detected long distance, but if there is more noise signal in the
environment, it will re-trigger too frequency.
---|---
Parameter 4: Light Threshold
Setting the illumination threshold toturn on the light. When the
eventtriggered and the environmentillumination lower then the threshold,the
device will turn on the light.0 means turn off illumination detectedfunction.
And never turn on the light.1 means darkest.99 means brightest.100 means turn
off illuminationdetected function. And always turn onthe light.Notice: In none
test mode, only thevalue in 1 to 99 will enable theillumination detected
function andupdate the illumination value.
Size: 1 Byte, Default Value: 99
SettingDescription
0 – 100| 0 means turn off illumination detected function. And never turn on
the light. 1 means darkest. 99 means brightest. 100 means turn off
illumination
---|---
Parameter 5: Operation Mode
Operation mode. Using bit to control.Caution: The value is unsigned byte,the
range is from 0x00 ~ 0xFF.Bit1: 1 means test mode,0 means normal modeBit3:
Setting the temperature scale.0: Fahrenheit, 1:CelsiusBit4: Disable the
illumination reportafter event triggered. (1:Disable,0:Enable)Bit5: Disable
the temperature reportafter event triggered. (1:Disable,0:Enable)Bit7: Disable
the back key releaseinto test mode. (1:Disable,0:Enable)
Size: 1 Byte, Default Value: 0
SettingDescription
1 | 1 means test mode, 0 means normal mode. |
---|---|
3 | Bit3: Setting the temperature scale. 0: Fahrenheit, 1:Celsius |
4 | Bit4: Disable the illumination report after event triggered. (1:Disable, |
0:Enable)
5| Bit5: Disable the temperature report after event triggered. (1:Disable,
0:Enable)
7| Bit7: Disable the back key release into test mode. (1:Disable, 0:Enable)
Parameter 6: Mult- Sensor Function Switch
Multisensor function switch. Using bitto control.Caution: The value is
unsigned byte,the range is from 0x00 ~ 0xFF.Bit1: Disable PIR
integrateIllumination to turn ON the lightingnodes in the association group
2.(1:Disable, 0:Enable)
Size: 1 Byte, Default Value: 4
SettingDescription
2| Disable PIR integrate Illumination to turn ON the lighting nodes in the
association group 2. (1:Disable, 0:Enable)
---|---
Parameter 7: Customer Function
Customer function switch, using bitcontrol.Caution: The value is unsigned
byte,the range is from 0x00 ~ 0xFF.Bit1: Enable sending motion OFFreport.
(0:Disable, 1:Enable)Note: Depends on the Bit4,0: Report Notification CC,Type:
0x07, Event: 0xFE1: Sensor Binary Report,Type: 0x0C, Value: 0x00Bit2: Enable
PIR super sensitivitymode. (0:Disable, 1:Enable)Bit4: Notification Type,0:
Using Notification Report.1: Using Sensor Binary ReportBit5: Disable Multi CC
in auto report.(1:Disable, 0:Enable)Bit6: Disable to report battery statewhen
the device triggered. (1:Disable,0:Enable)
Size: 1 Byte, Default Value: 4
SettingDescription
1 | Bit1: Enable sending motion OFF report. (0:Disable, 1:Enable) |
---|---|
2 | Bit2: Enable PIR super sensitivity mode. (0:Disable, 1:Enable) |
4 | Bit4: Notification Type, 0: Using Notification Report. 1: Using Sensor |
Binary Report.
5| Bit5: Disable Multi CC in auto report.(1:Disable, 0:Enable)
6| Bit6: Disable to report battery state when the device triggered.
(1:Disable, 0:Enable)
Parameter 8: PIR Re- Detect Interval Time
In the normal mode, after the PIRmotion detected, setting the re-detecttime.
8 seconds per tick, default tick is3 (24 seconds).Setting the suitable value
to preventreceived the trigger signal toofrequently. Also can save the
batteryenergy.Notice: If this value bigger than theconfiguration setting NO.
9. There is aperiod after the light turned off andthe PIR not start
detecting.
Size: 1 Byte, Default Value: 3
SettingDescription
1 – 127| In the normal mode, after the PIR motion detected, setting the re-
detect time. 8 seconds per tick, default tick is 3 (24 seconds).
---|---
Parameter 9: Turn Off Light Time
After turn on the lighting, setting thedelay time to turn off the
lightingwhen the PIR motion is not detected.8 seconds per tick, default tick
is 4 (32seconds).0 means never send turn off lightcommand.
Size: 1 Byte, Default Value: 4
SettingDescription
0 – 127| After turn on the lighting, setting the delay time to turn off the
lighting when the PIR motion is not detected. 8 seconds per tick, default tick
is 4 (32 seconds). 0 means never send turn off light command
---|---
Technical Data
Hardware Platform | SD3502 |
---|---|
Device Type | Notification Sensor |
Network Operation | Reporting Sleeping Slave |
Firmware Version | HW: 1 FW: 1.29:01.20 |
Z-Wave Version | 6.51.02 |
Certification ID | ZC10-18026029 |
Z-Wave Product Id | 0x013C.0x0002.0x000D |
Sensors | Air TemperatureLuminance |
Supported Notification Types | Home Security |
Frequency | Russia – 868.4MHz, 869.85MHz |
Maximum transmission power | 5 mW |
Supported Command Classes
- Association Grp Info
- Association V2
- Battery
- Configuration
- Device Reset Locally
- Firmware Update Md V2
- Manufacturer Specific V2
- Multi Cmd
- Notification V4
- Powerlevel
- Security
- Sensor Binary V2
- Sensor Multilevel V5
- Version V2
- Wake Up V2
- Zwaveplus Info V2
Controlled Command Classes
- Basic
- Configuration
- Multi Cmd
Explanation of Z-Wave specific terms
-
Controller — is a Z-Wave device with capabilities to manage the network.
Controllers are typically Gateways,Remote Controls or battery operated wall controllers. -
Slave — is a Z-Wave device without capabilities to manage the network.
Slaves can be sensors, actuators and even remote controls. -
Primary Controller — is the central organizer of the network. It must be
a controller. There can be only one primary controller in a Z-Wave network. -
Inclusion — is the process of adding new Z-Wave devices into a network.
-
Exclusion — is the process of removing Z-Wave devices from the network.
-
Association — is a control relationship between a controlling device and
a controlled device. -
Wakeup Notification — is a special wireless message issued by a Z-Wave
device to announces that is able to communicate. -
Node Information Frame — is a special wireless message issued by a
Z-Wave device to announce its capabilities and functions.