Philio Technology Flood Multisensor PAT02-1A Manual
- June 8, 2024
- Philio Technology
Table of Contents
- Philio Technology
- Flood Multisensor
- SKU: PAT02-1A
- Quickstart
- Important safety information
- What is Z-Wave?
- Product Description
- Prepare for Installation / Reset
- Inclusion/Exclusion
- Communication to a Sleeping device (Wakeup)
- Quick trouble shooting
- Association – one device controls an other device
- Configuration Parameters
- Parameter 1: Basic Set OFF Level
- Parameter 10: Auto Report Battery Time
- Parameter 13: Auto Report Temperatur e Time
- Parameter 14: Auto Report Humidity Time
- Parameter 15: Auto Report Flood Time
- Parameter 2: Basic Set ON Level
- Parameter 20: Auto Report Tick Interval
- Parameter 21: Temperature Differential Report
- Parameter 23: Humidity Differential Report
- Parameter 5: Operation Mode
- Parameter 6: Mult- Sensor Function Switch
- Parameter 7: Customer Function
- Technical Data
- Supported Command Classes
- Controlled Command Classes
- Explanation of Z-Wave specific terms
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Philio Technology
Flood Multisensor
SKU: PAT02-1A
Quickstart
This is a
secure
Alarm Sensor
for
Russia.
Please make sure the internal battery is fully charged.
To add this device to your network execute the following action:
1. Have Z-WaveTM Controller entered inclusion mode.2. Pressing the tamper key
three times within 1.5 seconds to enter the inclusion mode.3. After add
successful, the device will wake to receive the setting command from Z-WaveTM
Controller about 20 seconds.
Please refer to the
Manufacturers
Manual
for more information.
Important safety information
Please read this manual carefully. Failure to follow the recommendations in
this manual may be dangerous or may violate the law.
The manufacturer, importer, distributor and seller shall not be liable for any
loss or damage resulting from failure to comply with the instructions in this
manual or any other material.
Use this equipment only for its intended purpose. Follow the disposal
instructions.
Do not dispose of electronic equipment or batteries in a fire or near open heat sources.
What is Z-Wave?
Z-Wave is the international wireless protocol for communication in the Smart
Home. This
device is suited for use in the region mentioned in the Quickstart section.
Z-Wave ensures a reliable communication by reconfirming every message ( two-
way
communication) and every mains powered node can act as a repeater for other
nodes
( meshed network ) in case the receiver is not in direct wireless range of
the
transmitter.
This device and every other certified Z-Wave device can be used together
with any other
certified Z-Wave device regardless of brand and origin as long as both are
suited for the
same frequency range.
If a device supports secure communication it will communicate with other
devices
secure as long as this device provides the same or a higher level of security.
Otherwise it will automatically turn into a lower level of security to
maintain
backward compatibility.
For more information about Z-Wave technology, devices, white papers etc.
please refer
to www.z-wave.info.
Product Description
It is the Z-WaveTM plus product, it support the security, OTA… Those newest features of the Z-WaveTM technology. Z-WaveTM is a wireless communication protocol designed for home automation, specifically to remotely control applications in residential and light commercial environments. The technology uses a low-power RF radio embedded or retrofitted into home electronics devices and systems, such as lighting, home access control, entertainment systems and household appliances
Prepare for Installation / Reset
Please read the user manual before installing the product.
In order to include (add) a Z-Wave device to a network it must be in factory
default
state. Please make sure to reset the device into factory default. You can do
this by
performing an Exclusion operation as described below in the manual. Every
Z-Wave
controller is able to perform this operation however it is recommended to use
the primary
controller of the previous network to make sure the very device is excluded
properly
from this network.
Reset to factory default
This device also allows to be reset without any involvement of a Z-Wave
controller. This
procedure should only be used when the primary controller is inoperable.
Notice: Use this procedure only in the event that the primary controller is lost or otherwise inoperable.1. Pressing tamper key four times within 1.5 seconds and do not release the tamper key in the 4th pressed, and the LED will light ON.2. After 3 seconds the LED will turn OFF, after that within 2 seconds, release the tamper key. If successful, the LED will light ON one second. Otherwise, the LED will flash once.3. IDs are excluded and all settings will reset to factory default.
Inclusion/Exclusion
On factory default the device does not belong to any Z-Wave network. The
device needs
to be added to an existing wireless network to communicate with the
devices of this network.
This process is called Inclusion.
Devices can also be removed from a network. This process is called
Exclusion.
Both processes are initiated by the primary controller of the Z-Wave network.
This
controller is turned into exclusion respective inclusion mode. Inclusion and
Exclusion is
then performed doing a special manual action right on the device.
Inclusion
1. Have Z-WaveTM Controller entered inclusion mode.2. Pressing the tamper key three times within 1.5 seconds to enter the inclusion mode.3. After add successful, the device will wake to receive the setting command from Z-WaveTM Controller about 20 seconds.
Exclusion
1. Have Z-WaveTM Controller entered exclusion mode.2. Pressing tamper key three times within 1.5 seconds to enter the exclusion mode.Node ID has been excluded.
Communication to a Sleeping device (Wakeup)
This device is battery operated and turned into deep sleep state most of the
time
to save battery life time. Communication with the device is limited. In order
to
communicate with the device, a static controller C is needed in the
network.
This controller will maintain a mailbox for the battery operated devices and
store
commands that can not be received during deep sleep state. Without such a
controller,
communication may become impossible and/or the battery life time is
significantly
decreased.
This device will wakeup regularly and announce the wakeup
state by sending out a so called Wakeup Notification. The controller can then
empty the mailbox. Therefore, the device needs to be configured with the
desired
wakeup interval and the node ID of the controller. If the device was included
by
a static controller this controller will usually perform all necessary
configurations. The wakeup interval is a tradeoff between maximal battery
life time and the desired responses of the device. To wakeup the device please
perform
the following action:
After the device adding to the network, it will wake-up once per day in default. When it wake-up it will broadcast the Wake Up Notification message to the network, and wake-up 10 seconds for receive the setting commands.The wake- up interval minimum setting is 30 minutes, and maximum setting is 120 hours. And the interval step is 30 minutes.Press the tamper key once. The device will wake-up 10 seconds.
Quick trouble shooting
Here are a few hints for network installation if things dont work as expected.
- Make sure a device is in factory reset state before including. In doubt exclude before include.
- If inclusion still fails, check if both devices use the same frequency.
- Remove all dead devices from associations. Otherwise you will see severe delays.
- Never use sleeping battery devices without a central controller.
- Dont poll FLIRS devices.
- Make sure to have enough mains powered device to benefit from the meshing
Association – one device controls an other device
Z-Wave devices control other Z-Wave devices. The relationship between one
device
controlling another device is called association. In order to control a
different
device, the controlling device needs to maintain a list of devices that will
receive
controlling commands. These lists are called association groups and they are
always
related to certain events (e.g. button pressed, sensor triggers, …). In case
the event happens all devices stored in the respective association group will
receive the same wireless command wireless command, typically a ‘Basic Set’
Command.
Association Groups:
Group NumberMaximum NodesDescription
1| 8| The group 1 is for receiving the report message, like triggered event,
temperature, humidity etc.
---|---|---
2| 8| The group 2 is for the light control, the device will send the Basic Set
command to this group.
Configuration Parameters
Z-Wave products are supposed to work out of the box after inclusion, however
certain configuration can adapt the function better to user needs or unlock
further
enhanced features.
IMPORTANT: Controllers may only allow configuring
signed values. In order to set values in the range 128 … 255 the value sent in
the application shall be the desired value minus 256. For example: To set a
parameter to 200 it may be needed to set a value of 200 minus 256 = minus
56.
In case of a two byte value the same logic applies: Values greater than 32768
may
needed to be given as negative values too.
Parameter 1: Basic Set OFF Level
Setting the BASIC command value.When the flood trigger off(0x00), send the
BASIC CC to the group 2.
Size: 1 Byte, Default Value: 0
SettingDescription
-128 – 127 | Setting the BASIC command value. When the flood trigger off(0x00), send the BASIC CC to the group 2. |
---|
Parameter 10: Auto Report Battery Time
The interval time for auto report thebattery level.0 means turn off auto
report.The default value is 12. The tick timecan setting by the configuration
No.20.
Size: 1 Byte, Default Value: 12
SettingDescription
0 – 127| The interval time for auto report the battery level. 0 means turn off
auto report. The default value is 12. The tick time can setting by the
configuration No.20.
---|---
Parameter 13: Auto Report Temperatur e Time
The interval time for auto report thetemperature.0 means turn off auto
report.The default value is 12. The tick timecan setting by the configuration
No.20.
Size: 1 Byte, Default Value: 12
SettingDescription
0 – 127| The interval time for auto report the temperature. 0 means turn off
auto report. The default value is 12. The tick time can setting by the
configuration No.20.
---|---
Parameter 14: Auto Report Humidity Time
The interval time for auto report thehumidity.0 means turn off auto
report.The default value is 12. The tick timecan setting by the configuration
No.20.
Size: 1 Byte, Default Value: 12
SettingDescription
0 – 127| The interval time for auto report the humidity. 0 means turn off auto
report. The default value is 12. The tick time can setting by the
configuration No.20.
---|---
Parameter 15: Auto Report Flood Time
The interval time for auto report theflood state.0 means turn off auto
report.The default value is 12. The tick timecan setting by the configuration
No.20.
Size: 1 Byte, Default Value: 12
SettingDescription
0 – 127| The interval time for auto report the flood state. 0 means turn off
auto report. The default value is 12. The tick time can setting by the
configuration No.20.
---|---
Parameter 2: Basic Set ON Level
Setting the BASIC command value.When the flood trigger on(0xFF), send the
BASIC CC to the group 2.
Size: 1 Byte, Default Value: -127
SettingDescription
-128 – 127 | Setting the BASIC command value. When the flood trigger on(0xFF), send the BASIC CC to the group 2. |
---|
Parameter 20: Auto Report Tick Interval
The interval time for auto report eachtick. Setting this configuration
willeffect configuration No.10, No.13,No.14 and No.15.Units of one
minute.Caution1: Setting to 0 means turn offall auto report function.Caution2:
The value is unsigned byte
Size: 1 Byte, Default Value: 30
SettingDescription
-128 – 127 | The interval time for auto report each tick. Setting this configuration will effect configuration No.10, No.13, No.14 and No.15. Units of one minute. |
---|
Parameter 21: Temperature Differential Report
The temperature differential to report.0 means turn off this function.The
unit is Fahrenheit.Enable this function the device willdetect every 10
seconds.And when the temperature is over 140degree Fahrenheit, it will
continuereport.
Size: 1 Byte, Default Value: 1
SettingDescription
0 – 127| The temperature differential to report. 0 means turn off this
function. The unit is Fahrenheit. Enable this function the device will detect
every 10 seconds. And when the temperature is over 140 degree Fahrenheit, it
will continue report.
---|---
Parameter 23: Humidity Differential Report
The humidity differential to report.0 means turn off this function.The unit
is percentage.Enable this function the device willdetect every 10 seconds.
Size: 1 Byte, Default Value: 5
SettingDescription
0 – 60| The humidity differential to report. 0 means turn off this function.
The unit is percentage. Enable this function the device will detect every 10
seconds.
---|---
Parameter 5: Operation Mode
Operation mode. Using bit to control.Bit0: Disable the Flood functionBit3:
Setting the temperature scale.0: Fahrenheit, 1:CelsiusBit5: Disable the
temperature reportafter event triggered. (1:Disable,0:Enable)
Size: 1 Byte, Default Value: 0
SettingDescription
0 | Bit0: Disable the Flood function. |
---|---|
3 | Bit3: Setting the temperature scale. 0: Fahrenheit, 1:Celsius |
5 | Bit5: Disable the temperature report after event triggered.(1:Disable, |
0:Enable)
Parameter 6: Mult- Sensor Function Switch
Multisensor function switch. Using bitto control.Bit6: Disable the humidity
report afterevent triggered. (1:Disable, 0:Enable)
Size: 1 Byte, Default Value: 0
SettingDescription
6| Bit6: Disable the humidity report after event triggered.(1:Disable,
0:Enable)
---|---
Parameter 7: Customer Function
Customer function switch, using bitcontrol.Bit3: Disable send out BASIC
OFFafter the flood event cleared.(1:Disable, 0:Enable)Bit4: Notification
Type,0: Using Notification Report.1: Using Sensor Binary ReportBit5: Disable
Multi CC in auto report.(1:Disable, 0:Enable)Bit6: Disable to report battery
statewhen the device triggered. (1:Disable,0:Enable)
Size: 1 Byte, Default Value: 0
SettingDescription
3| Bit3: Disable send out BASIC OFF after the flood event cleared. (1:Disable,
0:Enable)
---|---
4| Bit4: Notification Type, 0: Using Notification Report.1: Using Sensor
Binary Report.
5| Bit5: Disable Multi CC in auto report. (1:Disable, 0:Enable)
6| Bit6: Disable to report battery state when the device triggered.
(1:Disable, 0:Enable)
Technical Data
Hardware Platform | SD3502 |
---|---|
Device Type | Notification Sensor |
Network Operation | Reporting Sleeping Slave |
Firmware Version | HW: 1 FW: 1.14:01.12 |
Z-Wave Version | 6.51.06 |
Certification ID | ZC10-18036035 |
Z-Wave Product Id | 0x013C.0x0002.0x001F |
Supported Notification Types | Home SecurityWater Alarm |
Sensors | Air TemperatureHumidity |
Frequency | Russia – 868.4MHz, 869.85MHz |
Maximum transmission power | 5 mW |
Supported Command Classes
- Association Grp Info
- Association V2
- Battery
- Configuration
- Device Reset Locally
- Firmware Update Md V2
- Manufacturer Specific V2
- Multi Cmd
- Notification V4
- Powerlevel
- Security
- Sensor Binary V2
- Sensor Multilevel V5
- Version V2
- Wake Up V2
- Zwaveplus Info V2
Controlled Command Classes
- Basic
Explanation of Z-Wave specific terms
-
Controller — is a Z-Wave device with capabilities to manage the network.
Controllers are typically Gateways,Remote Controls or battery operated wall controllers. -
Slave — is a Z-Wave device without capabilities to manage the network.
Slaves can be sensors, actuators and even remote controls. -
Primary Controller — is the central organizer of the network. It must be
a controller. There can be only one primary controller in a Z-Wave network. -
Inclusion — is the process of adding new Z-Wave devices into a network.
-
Exclusion — is the process of removing Z-Wave devices from the network.
-
Association — is a control relationship between a controlling device and
a controlled device. -
Wakeup Notification — is a special wireless message issued by a Z-Wave
device to announces that is able to communicate. -
Node Information Frame — is a special wireless message issued by a
Z-Wave device to announce its capabilities and functions.