V ENTURE L IGHTING’S H IGH B AY F IXTURE 300W (120-277V INPUT)
Before You Begin
Read These Instructions Completely and Carefully
Upgrade Instructions
STEP 1: Disconnect power from the luminaire and follow proper
lockout/tagout procedures before beginning installation or maintenance.
STEP 2: Remove the existing luminaire. Dispose of the lamp(s) and
ballast(s) per local requirements.
STEP 3: Each fixture is supplied with a carabiner (1). Place the
carabiner through the eyelet of the eyebolt (2) on top of the fixture. STEP
4: Attach the carabiner to a secure structure.
STEP 5: Connect the fixture input leads to the supply wire leads.
STEP 6: Each fixture is supplied with 1-10V DC dimming leads.
-
If dimming is not needed, nothing needs to be done.
NOTE: Do NOT connect the dimming leads together. This will cause the fixture to not operate as desired. -
If dimming is desired:
a) Connect the “+” supply lead to the “+” connection lead on the fixture.
b) Connect the “-” supply lead to the “-” connection lead on the fixture.
NOTE: The polarity of the dimming leads is important.
Improper connection will cause the fixture to not operate as desired.
Wiring Diagram
STEP 7: Loop the safety cable through the opening on the side of the fixture as shown. Attach the opposite end of the safety cable to a secure structure. (3)
STEP 8: Power can now be restored to the fixture.
Reflector Installation
- Remove 3 of the screws which hold down the lens (remove every other screw).
- Place the reflector onto the fixture and secure to the fixture with the 3 longer screws supplied with the reflector.
Lens Installation
Pendant Mount Installation
- Remove the eyebolt from the fixture.
- Secure the pendant bracket to the fixture using the hardware provided.
- Insert the pendant connector into the pendant bracket and secure the pendant connector to the bracket with the hardware provided.
- Screw in the appropriate threaded conduit fitting/pipe and secure with the locking screw.
- Complete the installation of the assembled pendant fixture by following the installation instructions above.
Safety Cable Assembly
WARNING
Risk of fire and electric shock
- Disconnect power from the luminaire and follow proper lockout/tagout procedures before beginning installation or maintenance. Contact a qualified electrician for installation.
- Venture Lighting’s High Bay Fixture installation requires knowledge of luminaire electrical systems. If not qualified, do not attempt installation. Contact a qualified electrician.
- To prevent wiring damage or abrasion, do not expose wiring to edges of sheet metal or other sharp objects.
- Do not make or alter any open holes in a wiring enclosure or electrical component during installation.
- Do not dismantle the fixture without Venture Lighting approval.
- If the external flexable cable of the luminaire is damaged, it should only be replaced by the supplier, a service agent or a Venture Lighting approved qualified person.
CAUTION
- Suitable for use in wet locations only.
- Venture Lighting’s High Bay Fixture must be operated within an ambient fixture temperature range of -30° to 40°C.
http://www.venturelighting.com/
AP0010-C
800-451-2606
6675 Parkland Blvd., Suite 100
Solon, Ohio 44139 USA
E-mail:
Venture_Lighting@VentureLighting.com
VentureLighting.com
© 2022 Venture Lighting International
Documents / Resources
|
VENTURE LIGHTING AP0010 High Bay
Fixture
[pdf] User Manual
AP0010 High Bay Fixture, AP0010, High Bay Fixture, Bay Fixture, Fixture
---|---
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>