devolo Metering Plug MT02646 Manual

June 8, 2024
devolo

devolo

Metering Plug

SKU: MT02646

Quickstart

This is a ****

On/Off Power Switch
for
CEPT (Europe)
.

To run this device please connect it to your mains power supply.

To add this device to your network execute the following action:
1.Put your Z-Wave controller into inclusion mode by following the instructions provided by the controller manufacturer. 2.Pressing On/Off button three times within 2 seconds will enter inclusionmode on the switch.

Please refer to the
Manufacturers Manual
for more information.

Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law.
The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material.
Use this equipment only for its intended purpose. Follow the disposal instructions.

Do not dispose of electronic equipment or batteries in a fire or near open heat sources.

What is Z-Wave?

Z-Wave is the international wireless protocol for communication in the Smart Home. This
device is suited for use in the region mentioned in the Quickstart section.

Z-Wave ensures a reliable communication by reconfirming every message ( two- way
communication
) and every mains powered node can act as a repeater for other nodes
( meshed network ) in case the receiver is not in direct wireless range of the
transmitter.

This device and every other certified Z-Wave device can be used together with any other
certified Z-Wave device regardless of brand and origin
as long as both are suited for the
same frequency range.

If a device supports secure communication it will communicate with other devices
secure as long as this device provides the same or a higher level of security.
Otherwise it will automatically turn into a lower level of security to maintain
backward compatibility.

For more information about Z-Wave technology, devices, white papers etc. please refer
to www.z-wave.info.

Product Description

This plug-in ON/OFF switch Home Control Metering Plug is a security enabled wireless switch, based on Z-Wave Plus technology. Z-Wave Plus enabled devices displayingtheZ-Wave Plus logo can also be used with it regardless of the manufacturer, and can also be used in other manufacturers Z-Wave enabled networks. Remote On/Off control of the connected load is possible with other manufacturers wireless Controller. Each switch is designed to act as a repeater. Repeaters will re-transmit the RF signal to ensure that the signal is received by itsintended destination by routing the signal around obstacles and radio dead spots. Because Home Control Metering Plug supports Security Command Class, it can be added with a Secured controller. Its functionality and supported command classes is identical when included as a secure and non- secure device. This plug-in ON/OFF switch is able to detect instance wattage (3000W/CE/CN,1500W/UL/TW/JP) and overload current (14.5A) of connected lights or appliances. When detecting overload state, the Switch will be disabled and its On/Off button will be lockout of which LED will flash quickly. However, unplug and re-connect the switch will reset its overload condition to normal status.

Prepare for Installation / Reset

Please read the user manual before installing the product.

In order to include (add) a Z-Wave device to a network it must be in factory default
state.
Please make sure to reset the device into factory default. You can do this by
performing an Exclusion operation as described below in the manual. Every Z-Wave
controller is able to perform this operation however it is recommended to use the primary
controller of the previous network to make sure the very device is excluded properly
from this network.

Reset to factory default

This device also allows to be reset without any involvement of a Z-Wave controller. This
procedure should only be used when the primary controller is inoperable.

(Use this procedure only in the event that the primary controller is lost or otherwise inoperable.)1.Pressing On/Off button three times within 2 seconds will enter inclusion mode on the switch.2.Within 1 second, press On/Off button again for 5 seconds.

Safety Warning for Mains Powered Devices

ATTENTION: only authorized technicians under consideration of the country- specific
installation guidelines/norms may do works with mains power. Prior to the assembly of
the product, the voltage network has to be switched off and ensured against re-switching.

Inclusion/Exclusion

On factory default the device does not belong to any Z-Wave network. The device needs
to be added to an existing wireless network to communicate with the devices of this network.
This process is called Inclusion.

Devices can also be removed from a network. This process is called Exclusion.
Both processes are initiated by the primary controller of the Z-Wave network. This
controller is turned into exclusion respective inclusion mode. Inclusion and Exclusion is
then performed doing a special manual action right on the device.

Inclusion

1.Put your Z-Wave controller into inclusion mode by following the instructions provided by the controller manufacturer. 2.Pressing On/Off button three times within 2 seconds will enter inclusionmode on the switch.

Exclusion

1.Put your Z-Wave controller into exclusion mode by following the instructions provided by the controller manufacturer. 2.Pressing On/Off button three times within 2 seconds will enter exclusionmode on the switch.

Quick trouble shooting

Here are a few hints for network installation if things dont work as expected.

  1. Make sure a device is in factory reset state before including. In doubt exclude before include.
  2. If inclusion still fails, check if both devices use the same frequency.
  3. Remove all dead devices from associations. Otherwise you will see severe delays.
  4. Never use sleeping battery devices without a central controller.
  5. Dont poll FLIRS devices.
  6. Make sure to have enough mains powered device to benefit from the meshing

Association – one device controls an other device

Z-Wave devices control other Z-Wave devices. The relationship between one device
controlling another device is called association. In order to control a different
device, the controlling device needs to maintain a list of devices that will receive
controlling commands. These lists are called association groups and they are always
related to certain events (e.g. button pressed, sensor triggers, …). In case
the event happens all devices stored in the respective association group will
receive the same wireless command wireless command, typically a ‘Basic Set’ Command.

Association Groups:

Group NumberMaximum NodesDescription

1 1 Z-Wave Plus Lifeline

Configuration Parameters

Z-Wave products are supposed to work out of the box after inclusion, however
certain configuration can adapt the function better to user needs or unlock further
enhanced features.

IMPORTANT: Controllers may only allow configuring
signed values. In order to set values in the range 128 … 255 the value sent in
the application shall be the desired value minus 256. For example: To set a
parameter to 200 it may be needed to set a value of 200 minus 256 = minus 56.
In case of a two byte value the same logic applies: Values greater than 32768 may
needed to be given as negative values too.

Parameter 1: Watt Meter Report Period

This configuration parameter determines how often meter reporting of instantaneous watt usage is reported automatically.Each unit is 5 seconds.The maximum interval to report its instant power consumption is 45 hours (5s*32767/3600=45hr).
Size: 2 Byte, Default Value: 720

SettingDescription

1 – 32767| Enable automatic interval reporting with an interval of 5 * the value.
---|---
0| Disable automatic interval meter reporting of Watts

Parameter 2: KWH Meter Report Period:

This parameter controls the frequency at which the kWh value of the meter is reported to the node in association group 1.This setting is in units of 10 minutes. The maximum interval to report its Accumulated Power Consumption (KW/h) is 227.55 days (10min*32767/1440=227.55 days).
Size: 2 Byte, Default Value: 6

SettingDescription

1 – 32767 6*10 min=1 hour
0 Disable automatic interval meter kWh reporting.

Parameter 3: Threshold of current for Load Caution

This is a warning when the current of load over the preset threshold value, if the setting value is 1300, when the load current of Relay1 over this value, Home Control Metering Plug will send current meter report to warn the Group1 node, the Range of the setting value is from 10 to 1300,and the default value is 1300.
Size: 2 Byte, Default Value: 1300

SettingDescription

10 – 1300 1300*0.01A = 13A

Parameter 4: Threshold of KWh for Load Caution

This is a warning when the KWh of load over the preset threshold value, If the setting value is 10000, when the Accumulated Power Consumption of Relay1 over this value, Home Control Metering Plug will send KWH meter report to warn the Group1 node, minimum value is 1KWh and default value is 10000 kWh.
Size: 2 Byte, Default Value: 10000

SettingDescription

1 – 10000| Enable automatic warning when the accumulated kWh power consumption exceeds the setting value from 1KWh ~ 10000KWh.
---|---
0| Disable kWh Load Caution Reporting

Parameter 5: Restore switch state mode

Whenever the AC power return from lost, Home Control Metering Plug will restore the switch state which could be SWITCH OFFLAST SWITCH STATESWITCH ON. The default setting is LAST SWITCH STATE.
Size: 1 Byte, Default Value: 1

SettingDescription

0 Upon the return of AC power, the switch will remain Off.
1 Upon the return of AC power, the switch will return to the state it was in

when the power was turned off.
2| Upon the return of AC power, the switch will turn On.

Parameter 6: Mode of switch off function

This configuration parameter determines how the switch will respond to a received SWITCH OFF command.
Size: 1 Byte, Default Value: 1

SettingDescription

0 SWITCH OFF commands received are ignored.
1 SWITCH OFF commands received are honored.

Parameter 7: LED indication mode

This parameter determines the state of the LED display.
Size: 1 Byte, Default Value: 1

SettingDescription

1 The LED follows the state of the switch.
2 Night Mode – When the switch is On, the LED is Off, and when the switch is

Off, the LED is On.
3| Flash Mode – When the state of the switch changes, the LED will be on for one second and then will turn off.

Parameter 8: Auto off timer

Automatic Shut-Off Setting.This parameter determines the amount of time before the switch is automatically turned off after it has been turned on.
Size: 1 Byte, Default Value: 0

SettingDescription

1 – 32767 1s ~ 32767s for automatically turning off
0 Disable the auto off function

Parameter 9: RF off command mode

_This parameter determines how the switch responds to the receipt of a SWITCH_ALLOFF command.
Size: 1 Byte, Default Value: 0

SettingDescription

0 When SWITCH ALL OFF is received, the MT02646 turns Off.
1 When SWITCH ALL OFF is received, the MT02646 ignores the command and does

nothing.
2| When SWITCH ALL OFF is received, the MT02646 will turn On if it is Off, and will turn Off if it is On.
3| When SWITCH ALL OFF is received, the MT02646 turns On.

Technical Data

Hardware Platform SD3502
Device Type On/Off Power Switch
Network Operation Always On Slave
Firmware Version 01
Z-Wave Version 6.51.00
Certification ID ZC10-14090006
Z-Wave Product Id 0x0175.0x0001.0x0011
Frequency XXfrequency
Maximum transmission power XXantenna

Explanation of Z-Wave specific terms

  • Controller — is a Z-Wave device with capabilities to manage the network.
    Controllers are typically Gateways,Remote Controls or battery operated wall controllers.

  • Slave — is a Z-Wave device without capabilities to manage the network.
    Slaves can be sensors, actuators and even remote controls.

  • Primary Controller — is the central organizer of the network. It must be
    a controller. There can be only one primary controller in a Z-Wave network.

  • Inclusion — is the process of adding new Z-Wave devices into a network.

  • Exclusion — is the process of removing Z-Wave devices from the network.

  • Association — is a control relationship between a controlling device and
    a controlled device.

  • Wakeup Notification — is a special wireless message issued by a Z-Wave
    device to announces that is able to communicate.

  • Node Information Frame — is a special wireless message issued by a
    Z-Wave device to announce its capabilities and functions.

Read User Manual Online (PDF format)