Aeotec Micro Motor Control AEO_MMC Manual
- June 8, 2024
- Aeotec
Table of Contents
- Aeon Labs
- Micro Motor Control
- SKU: AEO_MMC
- Quickstart
- Important safety information
- What is Z-Wave?
- Product Description
- Prepare for Installation / Reset
- Installation
- Inclusion/Exclusion
- Product Usage
- Quick trouble shooting
- Association – one device controls an other device
- Configuration Parameters
- Parameter 1: Type of Sensor Report
- Parameter 2: Blinking Behavior
- Parameter 80: Notification on Status Change
- Parameter 90: Disables Function of automated sending of a Report
- Parameter 91: Minimum Change to send Report (Watt)
- Parameter 92: Minimum Change to send Report (%)
- Parameter 101: Report type send in Reporting Group 1
- Parameter 102: Report Type send in Reporting Group 2
- Parameter 103: Report Type send in Reporting Group 3
- Parameter 111: Send Interval for Reporting Group 1
- Parameter 112: Send Interval for Reporting Group 2
- Parameter 113: Send Interval for Reporting Group 3
- Technical Data
- Supported Command Classes
- Explanation of Z-Wave specific terms
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Aeon Labs
Micro Motor Control
SKU: AEO_MMC
Quickstart
This is a ****
Window Control
for
Europe.
To run this device please connect it to your mains power supply.
Single click the button located near the Status Indication LED or alternatively press the external switch/ button control quickly 6 times to include or exclude the device. If the Aeon Labs Micro Motor Control is not included into any Z-Wave network, the LED will be blinking slowly continually.
Important safety information
Please read this manual carefully. Failure to follow the recommendations in
this manual may be dangerous or may violate the law.
The manufacturer, importer, distributor and seller shall not be liable for any
loss or damage resulting from failure to comply with the instructions in this
manual or any other material.
Use this equipment only for its intended purpose. Follow the disposal
instructions.
Do not dispose of electronic equipment or batteries in a fire or near open heat sources.
What is Z-Wave?
Z-Wave is the international wireless protocol for communication in the Smart
Home. This
device is suited for use in the region mentioned in the Quickstart section.
Z-Wave ensures a reliable communication by reconfirming every message ( two-
way
communication) and every mains powered node can act as a repeater for other
nodes
( meshed network ) in case the receiver is not in direct wireless range of
the
transmitter.
This device and every other certified Z-Wave device can be used together
with any other
certified Z-Wave device regardless of brand and origin as long as both are
suited for the
same frequency range.
If a device supports secure communication it will communicate with other
devices
secure as long as this device provides the same or a higher level of security.
Otherwise it will automatically turn into a lower level of security to
maintain
backward compatibility.
For more information about Z-Wave technology, devices, white papers etc.
please refer
to www.z-wave.info.
Product Description
The Aeon Labs Micro Motor Control is a Z-Wave blind control device specifically used to enable Z-Wave commands and control (up/down) for existing in-wall blind and motor controls. The wireless module is powered from the mains supply and is designed for a 3 wire system which requires a neutral connection. In the event of power failure, non-volatile memory retains all programmed information relating to the units operating status.
Prepare for Installation / Reset
Please read the user manual before installing the product.
In order to include (add) a Z-Wave device to a network it must be in factory
default
state. Please make sure to reset the device into factory default. You can do
this by
performing an Exclusion operation as described below in the manual. Every
Z-Wave
controller is able to perform this operation however it is recommended to use
the primary
controller of the previous network to make sure the very device is excluded
properly
from this network.
Safety Warning for Mains Powered Devices
ATTENTION: only authorized technicians under consideration of the country-
specific
installation guidelines/norms may do works with mains power. Prior to the
assembly of
the product, the voltage network has to be switched off and ensured against
re-switching.
Installation
The device is designed for a 3 wire system which requires a neutral connection. The module is powered from the main supply.
The schematic below shows how to wire the actuator. The power supply and the appliance are connected by the Power Input and Neutral connectors. The 3.3 Volt and External Switch connectors are for external switching.
After the electrical installation the device has to be implemented in the Z-Wave Network.
Inclusion/Exclusion
On factory default the device does not belong to any Z-Wave network. The
device needs
to be added to an existing wireless network to communicate with the
devices of this network.
This process is called Inclusion.
Devices can also be removed from a network. This process is called
Exclusion.
Both processes are initiated by the primary controller of the Z-Wave network.
This
controller is turned into exclusion respective inclusion mode. Inclusion and
Exclusion is
then performed doing a special manual action right on the device.
Inclusion
To include the Aeon Labs Micro Motor Control with your Z-Wave controller, simple bring it in inclusion-mode and click the Inclusion/Exclusion button at the Aeon Labs Micro Motor Control once. Alternatively you can use the external switch by quickly pressing it six times. If the Aeon Labs Micro Motor Control was successfully included to a Z-Wave network, the Status Indication LED will either be solid on or off (depending on if the switch is on or off) 10 seconds after the button was pressed last.
Exclusion
To include the Aeon Labs Micro Motor Control with your Z-Wave controller, simple bring it in inclusion-mode and click the Inclusion/Exclusion button at the Aeon Labs Micro Motor Control once. Alternatively you can use the external switch by quickly pressing it six times. If the Aeon Labs Micro Motor Control was successfully included to a Z-Wave network, the Status Indication LED will either be solid on or off (depending on if the switch is on or off) 10 seconds after the button was pressed last.
Product Usage
The device is operated by an external switch/button or wireless. Pressing the button on the external (Wall) switch will spin the motor up/down/stop. A short press on the button of the Motor Controller will spin the motor up/down. A hold and release of the button will stop the Motor Controller at the desired position.
Quick trouble shooting
Here are a few hints for network installation if things dont work as expected.
- Make sure a device is in factory reset state before including. In doubt exclude before include.
- If inclusion still fails, check if both devices use the same frequency.
- Remove all dead devices from associations. Otherwise you will see severe delays.
- Never use sleeping battery devices without a central controller.
- Dont poll FLIRS devices.
- Make sure to have enough mains powered device to benefit from the meshing
Association – one device controls an other device
Z-Wave devices control other Z-Wave devices. The relationship between one
device
controlling another device is called association. In order to control a
different
device, the controlling device needs to maintain a list of devices that will
receive
controlling commands. These lists are called association groups and they are
always
related to certain events (e.g. button pressed, sensor triggers, …). In case
the event happens all devices stored in the respective association group will
receive the same wireless command wireless command, typically a ‘Basic Set’
Command.
Association Groups:
Group NumberMaximum NodesDescription
1 | 5 | Status Reports |
---|
Configuration Parameters
Z-Wave products are supposed to work out of the box after inclusion, however
certain configuration can adapt the function better to user needs or unlock
further
enhanced features.
IMPORTANT: Controllers may only allow configuring
signed values. In order to set values in the range 128 … 255 the value sent in
the application shall be the desired value minus 256. For example: To set a
parameter to 200 it may be needed to set a value of 200 minus 256 = minus
56.
In case of a two byte value the same logic applies: Values greater than 32768
may
needed to be given as negative values too.
Parameter 1: Type of Sensor Report
Defines the value type to be sent as Sensor Report.
Size: 1 Byte, Default Value: 00
SettingDescription
00 | Power |
---|---|
01 | Voltage |
Parameter 2: Blinking Behavior
This is a double byte value. The LSB defines the total time the device need
to blink. The value if set in seconds. The MSB defines the on/off interval of
the blinking. The unit is 0.1 s.
Size: 2 Byte, Default Value: 0000
SettingDescription
Parameter 80: Notification on Status Change
Defines the automated status notification of an associated device when
status changes
Size: 1 Byte, Default Value: 00
SettingDescription
00 | Deactivated |
---|---|
01 | Hail sent |
02 | BASIC Report Sent |
Parameter 90: Disables Function of automated sending of a Report
triggered by minimal change of value.
__
Size: 1 Byte, Default Value: 00
SettingDescription
00 | Disabled |
---|---|
01 | Enabled |
Parameter 91: Minimum Change to send Report (Watt)
The value represents the minimum change in Wattage for a Report to be sent
.
Size: 2 Byte, Default Value: 0032
SettingDescription
00 – 3500 | Value in Watt |
---|
Parameter 92: Minimum Change to send Report (%)
The value represents the minimum change in Wattage Percent for a report to
be sent
Size: 1 Byte, Default Value: 0a
SettingDescription
00 – 100 | Percentage |
---|
Parameter 101: Report type send in Reporting Group 1
Defines the type of report sent for the Reporting Group 1.
Size: 4 Byte, Default Value: 00000008
SettingDescription
Byte 1: 00000100 | MultiSensor Report |
---|---|
Byte 1: 00001000 | Meter Report for Watt |
Byte 1: 00010000 | Meter Report for kWh |
Parameter 102: Report Type send in Reporting Group 2
Defines the type of report sent for the Reporting Group 2.
Size: 4 Byte, Default Value: 00000000
SettingDescription
Byte 1: 00000100 | MultiSensor Report |
---|---|
Byte 1: 00001000 | Meter Report for Watt |
Byte 1: 00010000 | Meter Report for kWh |
Parameter 103: Report Type send in Reporting Group 3
Defines the type of report sent for the Reporting Group 3.
Size: 4 Byte, Default Value: 00000000
SettingDescription
Byte 1: 00000100 | MultiSensor Report |
---|---|
Byte 1: 00001000 | Meter Report for Watt |
Byte 1: 00010000 | Meter Report for kWh |
Parameter 111: Send Interval for Reporting Group 1
Defines the time interval when the defined report of Reporting Group 1 is
sent out.
Size: 4 Byte, Default Value: 000002d0
SettingDescription
00 – ffff | Seconds |
---|
Parameter 112: Send Interval for Reporting Group 2
Defines the time interval when the defined report of Reporting Group 2 is
sent out.
Size: 4 Byte, Default Value: 000002d0
SettingDescription
00 – ffff | Seconds |
---|
Parameter 113: Send Interval for Reporting Group 3
Defines the time interval when the defined report of Reporting Group 3 is
sent out.
Size: 4 Byte, Default Value: 0000ffff
SettingDescription
00 – ffff | Seconds |
---|
Technical Data
Dimensions | 0.0040000×0.0050000×0.0020000 mm |
---|---|
Weight | 50 gr |
Hardware Platform | ZM3102 |
Voltage | 230 |
Device Type | Window Covering No Position/Endpoint |
Generic Device Class | Multilevel Switch |
Specific Device Class | Motor Control Device (A) |
Firmware Version | 01.17 |
Z-Wave Version | 02.4e |
Z-Wave Product Id | 0086.0003.000e |
Frequency | Europe – 868,4 Mhz |
Maximum transmission power | 5 mW |
Supported Command Classes
- Basic
- Switch Binary
- Version
- Switch All
- Manufacturer Specific
- Configuration
- Sensor Multilevel
- Meter
- Switch Multilevel
- Association
Explanation of Z-Wave specific terms
-
Controller — is a Z-Wave device with capabilities to manage the network.
Controllers are typically Gateways,Remote Controls or battery operated wall controllers. -
Slave — is a Z-Wave device without capabilities to manage the network.
Slaves can be sensors, actuators and even remote controls. -
Primary Controller — is the central organizer of the network. It must be
a controller. There can be only one primary controller in a Z-Wave network. -
Inclusion — is the process of adding new Z-Wave devices into a network.
-
Exclusion — is the process of removing Z-Wave devices from the network.
-
Association — is a control relationship between a controlling device and
a controlled device. -
Wakeup Notification — is a special wireless message issued by a Z-Wave
device to announces that is able to communicate. -
Node Information Frame — is a special wireless message issued by a
Z-Wave device to announce its capabilities and functions.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>