Aeotec Panic Button AEO_PANIC Manual

June 8, 2024
Aeotec

Aeon Labs

Aeotec Panic Button

SKU: AEO_PANIC

Quickstart

This is a ****

Remote Control
for
Europe
.

To run this device please insert fresh *1 CR2450** batteries.

Please make sure the internal battery is fully charged.

Remove the back cover of the device and fit in the battery. Make sure to check for the correct polarisation. Set the back cover back in place and start the inclusion. There are two possibilities for the inclusion.

1. Inclusion into an existing network: In this case the Panic Button will act as a secondary controller in the network. Set the primary controller of your network into inclusion mode. If you are unsure how to do that please refer to it”s user manual. Press the “Learn” button on the back of the Panic Button once with the enclosed Pin. The LED on the front will start flashing. Once the inclusion is finished the LED will stay solid for two seconds.

2. Creating a new network: The Panic Button can act as primary controller of it”s own network. To add devices to it”s network press the “Include/Exclude” button on the back of the Panic Button with the enclosed Pin. The LED on the front will start flashing slowly. Now press the Z-Wave button of the device you want to add. Once the device was added to the Panic Button”s network the LED will stay solid green for two seconds. Repeat this process for every device you want to add. Once you have included all devices press any button on the Panic Button to exit the inclusion.

Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law.
The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material.
Use this equipment only for its intended purpose. Follow the disposal instructions.

Do not dispose of electronic equipment or batteries in a fire or near open heat sources.

What is Z-Wave?

Z-Wave is the international wireless protocol for communication in the Smart Home. This
device is suited for use in the region mentioned in the Quickstart section.

Z-Wave ensures a reliable communication by reconfirming every message ( two- way
communication
) and every mains powered node can act as a repeater for other nodes
( meshed network ) in case the receiver is not in direct wireless range of the
transmitter.

This device and every other certified Z-Wave device can be used together with any other
certified Z-Wave device regardless of brand and origin
as long as both are suited for the
same frequency range.

If a device supports secure communication it will communicate with other devices
secure as long as this device provides the same or a higher level of security.
Otherwise it will automatically turn into a lower level of security to maintain
backward compatibility.

For more information about Z-Wave technology, devices, white papers etc. please refer
to www.z-wave.info.

Product Description

The Aeon Labs Panic Button is a one button remote control, which is specifically designed for emergency situations. This Panic Button will work as a remote control within your Z-Wave network, allowing it to both control associated devices and act as a tool for adding/ removing devices to/ from your Z-Wave network. You can also use this onebutton remote control for non- emergency situations, e.g. to communicate with a Z-Wave device for turning on/ off or dimming the lighting or switching a device (garage doors).

Prepare for Installation / Reset

Please read the user manual before installing the product.

In order to include (add) a Z-Wave device to a network it must be in factory default
state.
Please make sure to reset the device into factory default. You can do this by
performing an Exclusion operation as described below in the manual. Every Z-Wave
controller is able to perform this operation however it is recommended to use the primary
controller of the previous network to make sure the very device is excluded properly
from this network.

Safety Warning for Batteries

The product contains batteries. Please remove the batteries when the device is not used.
Do not mix batteries of different charging level or different brands.

Installation

Remove the back cover of the Panic Button and set in the battery. Please check for the correct polarisation. Set the back cover back in.

Inclusion/Exclusion

On factory default the device does not belong to any Z-Wave network. The device needs
to be added to an existing wireless network to communicate with the devices of this network.
This process is called Inclusion.

Devices can also be removed from a network. This process is called Exclusion.
Both processes are initiated by the primary controller of the Z-Wave network. This
controller is turned into exclusion respective inclusion mode. Inclusion and Exclusion is
then performed doing a special manual action right on the device.

Inclusion

There are two possibilities to use the Panic Button.

As secondary controller in an existing network

  1. 1. Inclusion into an existing network: In this case the Panic Button will act as a secondary controller in the network. Set the primary controller of your network into inclusion mode. If you are unsure how to do that please refer to it”s user manual. Press the “Learn” button on the back of the Panic Button once with the enclosed Pin. The LED on the front will start flashing. Once the inclusion is finished the LED will stay solid for two seconds.
  2. 2. Exclusion from an existing network: Set the primary controller of your network into exclusion mode. If you are unsure how to do that please refer to it”s user manual. Press the “Learn” button on the back of the Panic Button once with the enclosed Pin. The LED on the front will start flashing. Once the exclusion is finished the LED will stay solid for two seconds.

As primary controller of a new network

  1. 1. Creating a new network: The Panic Button can act as primary controller of it”s own network. To add devices to it”s network press the “Include/Exclude” button on the back of the Panic Button with the enclosed Pin. The LED on the front will start flashing slowly. Now press the Z-Wave button of the device you want to add. Once the device was added to the Panic Button”s network the LED will stay solid green for two seconds. Repeat this process for every device you want to add. Once you have included all devices press any button on the Panic Button to exit the inclusion.
  2. 2. Exclude devices from the network: Press and hold the action button on the front. The LED will start flashing rapidly as soon as it is ready to exclude devices. Press the Z-Wave button of the device you want to remove. The LED will stop flashing and stay solid red for two seconds. Release the action button on the front. The Panic Button has now stopped communicating with the device. Repeat this process until you have removed all the devices you want.

To reset the Panic Button into the factory default state press and hold both the “Include/Exclude” and “Learn” button with the enclosed Pin for at least 10 seconds. The LED will start flashing green and then stay solid green for two seconds. If the reset failed the LED will stay solid red for two seconds. In this case please repeat the process.

Exclusion

There are two possibilities to use the Panic Button.

As secondary controller in an existing network

  1. 1. Inclusion into an existing network: In this case the Panic Button will act as a secondary controller in the network. Set the primary controller of your network into inclusion mode. If you are unsure how to do that please refer to it”s user manual. Press the “Learn” button on the back of the Panic Button once with the enclosed Pin. The LED on the front will start flashing. Once the inclusion is finished the LED will stay solid for two seconds.
  2. 2. Exclusion from an existing network: Set the primary controller of your network into exclusion mode. If you are unsure how to do that please refer to it”s user manual. Press the “Learn” button on the back of the Panic Button once with the enclosed Pin. The LED on the front will start flashing. Once the exclusion is finished the LED will stay solid for two seconds.

As primary controller of a new network

  1. 1. Creating a new network: The Panic Button can act as primary controller of it”s own network. To add devices to it”s network press the “Include/Exclude” button on the back of the Panic Button with the enclosed Pin. The LED on the front will start flashing slowly. Now press the Z-Wave button of the device you want to add. Once the device was added to the Panic Button”s network the LED will stay solid green for two seconds. Repeat this process for every device you want to add. Once you have included all devices press any button on the Panic Button to exit the inclusion.
  2. 2. Exclude devices from the network: Press and hold the action button on the front. The LED will start flashing rapidly as soon as it is ready to exclude devices. Press the Z-Wave button of the device you want to remove. The LED will stop flashing and stay solid red for two seconds. Release the action button on the front. The Panic Button has now stopped communicating with the device. Repeat this process until you have removed all the devices you want.

To reset the Panic Button into the factory default state press and hold both the “Include/Exclude” and “Learn” button with the enclosed Pin for at least 10 seconds. The LED will start flashing green and then stay solid green for two seconds. If the reset failed the LED will stay solid red for two seconds. In this case please repeat the process.

Product Usage

The Panic Button can act either as primary controller of it”s own network or as secondary controller of an existing network.

Usage in an existing network:

  1. 1. The Panic Button can include device into the existing network. In this case it will hand all the received data to the primary controller. Please refer to the inclusion section of this manual for information regarding the inclusion. In addition the primary controller can define scenes. Scenes can define a trigger and actions that should be performed once the trigger is activated. You can set up an emergency scene that has the Panic Button as trigger and performs the wished changes once the Panic Button is pressed. Please refer to the controller”s manual for information about how to define scenes.

Usage as primary controller:

  1. Please read in the inclusion section how to include devices into the Panic Button”s network. Press and hold the action button of the Panic Button. The LED will start to flash. Now press the Z-Wave button on the device you want to associate. The LED on the Panic Button will stay solid for 2 seconds to indicate a successful communication. Now change the device to the status it should change to when the Panic Button is activated. For example turn a button on if it should be turned on when the Panic Button is activated. Release the action button of the Panic Button. In case the LED does not show the described behaviour please repeat the process and make sure the devices are within 3 meters of one another. Repeat this for every device you want to associate.

Quick trouble shooting

Here are a few hints for network installation if things dont work as expected.

  1. Make sure a device is in factory reset state before including. In doubt exclude before include.
  2. If inclusion still fails, check if both devices use the same frequency.
  3. Remove all dead devices from associations. Otherwise you will see severe delays.
  4. Never use sleeping battery devices without a central controller.
  5. Dont poll FLIRS devices.
  6. Make sure to have enough mains powered device to benefit from the meshing

Association – one device controls an other device

Z-Wave devices control other Z-Wave devices. The relationship between one device
controlling another device is called association. In order to control a different
device, the controlling device needs to maintain a list of devices that will receive
controlling commands. These lists are called association groups and they are always
related to certain events (e.g. button pressed, sensor triggers, …). In case
the event happens all devices stored in the respective association group will
receive the same wireless command wireless command, typically a ‘Basic Set’ Command.

Association Groups:

Group NumberMaximum NodesDescription

1| 5|
---|---|---

Technical Data

Dimensions 0.0300000×0.0550000×0.0100000 mm
Weight 30 gr
EAN 1220000012042
Battery Type 1 * CR2450
Device Type Remote Control – Simple
Generic Device Class Portable Controller
Specific Device Class Portable Remote Controller
Firmware Version 01.0d
Z-Wave Version 02.4e
Z-Wave Product Id 0086.0001.0026
Frequency Europe – 868,4 Mhz
Maximum transmission power 5 mW

Supported Command Classes

  • Basic
  • Configuration
  • Manufacturer Specific
  • Battery
  • Wake Up
  • Association
  • Version
  • Scene Activation
  • Switch Multilevel

Controlled Command Classes

  • Scene Activation
  • Switch Multilevel

Explanation of Z-Wave specific terms

  • Controller — is a Z-Wave device with capabilities to manage the network.
    Controllers are typically Gateways,Remote Controls or battery operated wall controllers.

  • Slave — is a Z-Wave device without capabilities to manage the network.
    Slaves can be sensors, actuators and even remote controls.

  • Primary Controller — is the central organizer of the network. It must be
    a controller. There can be only one primary controller in a Z-Wave network.

  • Inclusion — is the process of adding new Z-Wave devices into a network.

  • Exclusion — is the process of removing Z-Wave devices from the network.

  • Association — is a control relationship between a controlling device and
    a controlled device.

  • Wakeup Notification — is a special wireless message issued by a Z-Wave
    device to announces that is able to communicate.

  • Node Information Frame — is a special wireless message issued by a
    Z-Wave device to announce its capabilities and functions.

Read User Manual Online (PDF format)