GE APPLIANCES PHS93XYPFS 30 Inch Smart Induction Range Instruction Manual
- June 8, 2024
- GE Appliances
Table of Contents
- GE APPLIANCES PHS93XYPFS 30 Inch Smart Induction Range Instruction Manual
- 1. REMOVE PACKAGING MATERIALS:
- 2 PREPARE THE OPENING (FOR INDOOR USE ONLY)
- MINIMUM DIMENSIONS BETWEEN COOKTOP,
- FRONT CONTROL
- 3 . ELECTRICAL REQUIREMENTS
- 5. 3-WIRE INSTALLATION
- FOR CONDUIT INSTALLATIONA
- Power Cord
- 6 4-WIRE INSTALLATION
- FOR POWER CORD INSTALLATIONA.
- FOR CONDUIT INSTALLATIONA.
- ANTI-TIP DEVICE INSTALLATION
- 8 LEVEL THE RANGE
- LEVEL THE RANGE (CONT.) MODELS WITH DOUBLE OVEN
- 9 FINAL INSTALLATION CHECKLIST
- OPERATION CHECKLISTU
- Read More About This Manual & Download PDF:
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
GE APPLIANCES PHS93XYPFS 30 Inch Smart Induction Range Instruction Manual
1. REMOVE PACKAGING MATERIALS:
Failure to remove packaging materials could result in damage to the appliance. Remove all packing parts from oven, racks, heating elements and drawer. Also, remove protective film and labels on the outer door, cooktop and control panel.
2 PREPARE THE OPENING (FOR INDOOR USE ONLY)
See illustrations for all rough-in and spacing dimensions. The range may be placed with 0” clearance (flush) at the back wall and side walls of the cabinet.
NOTE: Use a 4’ power cord to prevent interference with the storage drawer. Power cords 41 2’ to 6’ long may have to be dressed to allow for proper drawer closing.
MINIMUM DIMENSIONS BETWEEN COOKTOP,
WALLS AND ABOVE THE COOKTOP:
A. Make sure the wall covering, countertop, flooring and cabinets around the
range can withstand the heat (up to 200°F) generated by the range.
B. Allow 30” minimum clearance between surface units and bottom of unprotected
wood or metal cabinet, or allow a 24” minimum when bottom of wood or metal
cabinet is protected by no less than 1/4” thick flame retardant millboard
covered with not less than No 28 MSG sheet metal, (.015”), .015” thick
stainless steel, .024” aluminum or .020” copper. Acceptable electrical outlet
area. Orient electrical receptacle so the length is parallel to floor. Use a
flush mount outlet for double oven models.
C. This appliance has been approved for 0” spacing to adjacent surfaces above
the cooktop. However, a 6” minimum spacing to surfaces less than 15” above the
cooktop and adjacent cabinet is recommended to reduce exposure to steam,
grease splatter and heat. To reduce the risk of burns or fire when reaching
over hot surface elements, cabinet storage space above the cooktop should be
avoided. If cabinet storage space is to be provided above the cooktop, the
risk can be reduced by installing a range hood that projects at least 5”
beyond the front of the cabinets. Cabinets installed above the cooktop must be
no deeper than 16”
FRONT CONTROL
3 . ELECTRICAL REQUIREMENTS
This appliance must be properly grounded. All new constructions, mobile homes,
recreational vehicles and installations where local codes do not allow
grounding through neutral, require a 4-conductor UL-listed range cord. To
prevent fire or shock, do not use an extension cord with this appliance. To
prevent shock, remove house fuse or open circuit breaker before beginning
installation.
We recommend you have the electrical wiring and hookup of your range connected
by a qualified electrician. After installation, have the electrician show you
how to disconnect power from the range. You must use a single-phase, 120/208
VAC or 120/240 VAC, 60 hertz electrical system.
If you connect to aluminum wiring, properly installed connectors approved for
use with aluminum wiring must be used. Effective January 1, 1996, the
National Electrical Code requires that new construction (not existing) utilize
a 4-conductor connection to an electric range. When installing an electric
range in new construction, mobile home, recreational vehicle, or an area where
local codes prohibit grounding through the neutral conductor, refer to the
section on four-conductor branch circuit connections. Check with your local
utilities for electrical codes which apply in your area.
Failure to wire your oven according to governing codes could result in a
hazardous condition. If there are no local codes, your oven must be wired and
fused to meet the National Electrical Code, NFPA No. 70 – latest edition,
available from the National Fire Protection Association.
This appliance must be supplied with the proper voltage and frequency, and
connected to an individual, properly grounded, 40 amp (minimum) branch circuit
protected by a circuit breaker or time-delay fuse. Use only a 3-conductor or a
4-conductor UL-listed range cord.
These cords may be provided with ring terminals on wire and a strain relief
device. A range cord rated at 40 amps with 125/250 minimum volt range is
required. A 50 amp range connection openings. Care should be taken to center
the cable and strain relief within the knockout hole to keep the edge from
damaging the cable. The rating plate is located on the oven frame or on the
drawer frame
4. POWER CORD AND CONDUIT INSTALLATION
A. Remove wire cover (on the back of range) by removing screws using a 1/4” nut driver. You can access the terminal block by either removing a terminal block cover (on some models) or the wire cover. Do not discard these screws.
B. For power cord and 1” conduit only, remove the knockout ring (13
8”) located on bracket directly below the terminal block.
To remove the knockout, use a pair of pliers to bend the knockout ring away
from the bracket and twist until ring is removed.
C. For power cord installations only (see the next step if using conduit),
assemble the strain relief in the hole. Insert the power cord through the
strain relief and tighten. Allow enough slack to easily attach the cord
terminals to the terminal block. If tabs are present at the end of the winged
strain relief, they can be removed for better fit.
NOTE: Do not install the power cord without a strain relief. The strain relief
bracket MUST be installed before reinstalling the rear range wiring cover. D.
For 3/4” conduit installations only, purchase a squeeze connector matching the
diameter of your conduit and assemble it in the hole. Insert the conduit
through the squeeze connector and tighten. Allow enough slack to easily attach
the wires to the terminal block.
NOTE: Do not install the conduit without a squeeze connector. The squeeze
connector MUST be installed before reinstalling the rear range wire or
terminal
E. Replace wire cover on range back and replace the screws removed earlier.
Make sure that no wires are pinched between cover and range back. Replace the
terminal block cover if it was removed.
5. 3-WIRE INSTALLATION
The neutral or ground wire of the power cord must be connected to the neutral
terminal located in the center of the terminal block and the ground strap must
connect the neutral terminal to the ground plate. The power leads must be
connected to the lower left and the lower right terminals of the terminal
block. DO NOT remove the ground strap connection.
FOR POWER CORD INSTALLATION
A. Remove the 3 lower terminal screws from the terminal block.
B. Insert the 3 terminal screws through each power cord terminal ring and into
the lower terminals of the terminal block.
Be certain that the center wire (white/neutral) is connected to the center
lower position of the terminal block.
C. Tighten screws securely into the terminal block.
FOR CONDUIT INSTALLATIONA
. Loosen the 3 lower terminal screws on the terminal block. Strip wire to
expose tip about 5/8” long.
B. Insert the center (white/neutral) wire tip through the bottom center
terminal block opening. On certain models, the wire will need to be inserted
through the ground strap opening and then into the bottom center block
opening. Insert the two side bare wire tips into the lower left and the lower
right terminal block openings.
C. Tighten the screws until the wire is firmly secured (35 to 50 inch-lbs.).
Do not over-tighten the screws. NOTE: ALUMINUM WIRING: Aluminum building wire
may be used but it must be rated for the correct amperage and voltage.
Power Cord
6 4-WIRE INSTALLATION
The neutral wire of the supply circuit must be connected to the neutral terminal located in the lower center of the terminal block. The power leads must be connected to the lower left and the lower right terminals of the terminal block. The grounding lead must be connected to the frame of the range with the ground plate and the green ground screw.
FOR POWER CORD INSTALLATIONA.
Remove the 3 lower terminal screws from the terminal block. Remove the ground
screw and ground plate and retain them. Cut and discard the ground strap.
DO NOT DISCARD ANY SCREWS. B. Insert the one ground screw into the power cord
ground wire terminal ring, through the ground plate and into the frame of the
range. C. Insert the 3 terminal screws (removed earlier) through each power
cord terminal ring and into the lower terminals of the terminal block. Be
certain that the center wire (white/neutral) is connected to the center lower
position of the terminal block. Tighten screws securely into the terminal
block.
FOR CONDUIT INSTALLATIONA.
Loosen the 3 lower terminal screws on the terminal block. Strip wire to
exposed tip about 5/8” long.
B. Insert the center (white/neutral) wire tip through the bottom center
terminal block opening. On certain models, the wire will need to be ins erted
through the ground strap opening and then into the bottom center block
opening. Insert the two side bare wire tips into the lower left and the lower
right terminal block openings.
C. Tighten the screws until the wire is firmly secured (35 to 50 inch-lbs.).
Do not over-tighten the screws.NOTE: ALUMINUM WIRING: Aluminum building wire
may be used but it must be rated for the correct amperage and voltage
Before–Power Cord and Conduit
ANTI-TIP DEVICE INSTALLATION
To reduce the risk of tipping the range, the range must be secured by a properly installed anti-tip bracket. See installation instructions shipped with the bracket for complete details before attempting to install. To check if the bracket is installed and engaged properly, look underneath the range to see that the rear leveling leg is engaged in the bracket. On some models, the storage drawer or kick panel can be removed for easier inspection. If visual inspection is not possible, slide the range forward, confirm the anti-tip bracket is securely attached to the floor or wall and slide the range back so the leveling leg is under the anti-tip bracket. If the range is pulled from the wall for any reason, always repeat this procedure to verify the range is properly secured by the anti-tip bracket. Never completely remove the leveling legs or the range will not be secured to the anti-tip bracket.
8 LEVEL THE RANGE
Never completely remove the leveling leg as the range will not be secured to
the anti-tip device properly.
SINGLE OVEN MODELS WITH STORAGE DRAWERA. Plug in unit and slide into place.
B. Remove the drawer. Refer to your owner’s manual for instructions.
C. Install the oven shelves in the oven and position the range where it will
be installed.
D. Check for levelness by placing a spirit level on one of the oven shelves.
Take two readings—with the level placed diagonally first in one direction and
then the other.
E. The front leveling legs can be adjusted from the bottom and the rear legs
can be adjusted from the top or the bottom.
F. Use an adjustable wrench to adjust the leveling legs until the range is
level.
G. Position cord so that it does not interfere with drawer.H. Reinstall the
drawer. Refer to your owner’s manual for instructions
LEVEL THE RANGE (CONT.) MODELS WITH DOUBLE OVEN
A. Plug in the unit. B. Measure the height of your countertop at the rear of
the opening (X).
C. Adjust two rear leveling legs so that the rear of cooktop is at the same
height as the counter (Y).
D. Slide unit into place. E. Install oven shelves in the oven and position the
range where it will be installed.
F. Check for levelness by placing a spirit level on one of the oven shelves.
Take two readings—with the level placed diagonally first in one direction and
then the other.
G. Adjust front leveling legs until the range is level.
Some models have custom handles. Please follow the instructions with the handles for proper installation
9 FINAL INSTALLATION CHECKLIST
- Check to make sure the circuit breaker is closed (RESET) or the circuit fuses are replaced.
- Be sure power is in service to the building. Check that all packing materials and tape have been removed.
- This will include tape on metal panel under control knobs (if applicable), adhesive tape, wire ties, cardboard and protective plastic.
- Failure to remove these materials could result in damage to the appliance once the appliance has been turned on and surfaces have heated.
- Check that the door and drawer are parallel to each other and that both operate smoothly. If they do not, see the Owner’s Manual for proper replacement.
- Check to make sure that the rear leveling leg is fully inserted into the Anti-Tip bracket and that the bracket is securely installed. If applicable – install handles following handle installation instructions and check that both ends are secured.
OPERATION CHECKLISTU
sing a ferrous pan that meets the minimum pan size for the induction element
(refer to your
Owner’s Manual), turn on the power to the cooktop. Verify that all surface
elements operate properly.
Elements that are not induction do not require the pan for verification.
Check that the oven control operates properly. If the oven control does not
operate properly, recheck the wiring connections.
Be sure all range controls are in the OFF position before leaving the range.