AJAX AJ-LEAKSPROTECT-W LeaksProtect White Wireless sensor User Manual
- June 8, 2024
- ajax
Table of Contents
- AJAX AJ-LEAKSPROTECT-W LeaksProtect White Wireless sensor
- Introduction
- Functional Elements and Indication
- Operating Principle
- Connecting the detector to the Ajax security system
- Connecting to the third-party security systems
- Settings
- Indication
- Functionality Testing
- Selecting the Location
- Detector Testing
- Maintenance
- Tech specs
- Warranty
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
AJAX AJ-LEAKSPROTECT-W LeaksProtect White Wireless sensor
Introduction
- LeaksProtect is a wireless leakage detector that notifies both in case of a leak and when the water dries out. Developed only for indoor use.
- LeaksProtect connects to the Ajax security system via the protected Jeweller radio protocol. The communication range is up to 1300 meters in line of sight. Also,
- LeaksProtect can be connected to third-party security systems using the Ajax uanBrldge or Ajax ocBrldge Plus integration modules.
- Users can configure LeaksProtect via the Ajax app for macOS, Windows, iOS, or Android. The system notifies users of all events through push notifications, SMS, and calls (if activated).
- The user can connect the Ajax security system to the central monitoring station of a security company.
Buy leakage detector LeaksProtect
Functional Elements and Indication
- LED indicator
- Water sensor contacts
- QR code with the device registration key
- On/off button
Operating Principle
At the bottom of its body, LeaksProtect is equipped with four pairs of water sensitive contacts. If at least one contact pair gets wet, the detector immediately transmits an alann signal to the hub, notifying the user and security company. Also, the detector notifies users if the water dries out.
When switched on, L.eeksProtect is always active and monitors the situation regardless of the security mode: planned or armed.
Connecting the detector to the Ajax security system
Detector connection to the hub
Before connecting:
- Following the hub user manual, install the Ajax app. Create an account, add the hub to the app, and create at least one room.
- Check the internet connection (via Ethernet cable and/or GSM network).
- Check the hub status in the app: make sure that it is disarmed and does not update.
Only users with administrator rights can add the device to the hub.
How to pair the detector with the hub:
- Select Add Device in the Ajax app.
- Name the device, scan or enter the QR Code (located on the body and packaging), and select the location room.
- Select Add the countdown will begin.
- Switch on the device.
-
For the detection and pairing to occur, the device should be located within the wireless coverage area of the hub (at the same facility).
-
Request for connection is transmitted for a short time at the moment of switching on the device.
-
If the connection failed, LeaksProtect switches off after 6 seconds. To retry the connection, you do not need to reboot the device. If LeaksProtect is paired with
another hub, switch the detector off, then retry the standard adding procedure. -
The detector connected to the hub is displayed in the list of devices in the app. The update of the detector status in the list depends on the device inquiry time set in the hub settings (the default value is 36 seconds).
Connecting to the third-party security systems
To connect the detector to a third-party security central unit using the
uartBridge or Oxbridge Plus integration module, follow the recommendations in
the manual of the respective device.
The detector is always active. When connecting LeaksProtect to third-party
security systems, it is appropriate to place the detector in a permanently
active protection zone.
States
- Devices If
- LeaksProtect
Settings
- Devices If
- LeaksProtect
- Settings
Indication
The LeaksProtect LED indicator may light up red or green depending on the device status.
Indication when pressing the power button
Turned-on detector indication
Functionality Testing
Ajax security system allows conducting tests for checking the functionality of
connected devices.
The tests do not start straight away but within a period of 36 seconds when
using the standard settings. The test time start depends on the settings of
the detector scanning period (the paragraph on “Jeweller” settings in the hub
settings).
Jeweller Signal Strength Test
Attenuation Test
Selecting the Location
When selecting the device location, please take into account its remoteness from the hub (up to 1300 meters) and the absence of any obstacles between the devices hindering the radio signal transmission: walls, floors, large objects located in the room.
If the signal level is low (one bar), we cannot guarantee the stable operation of the device. Take all possible measures to improve the signal strength. At least, move the device: even a 20 cm shift can significantly improve the quality of signal reception.
If, after moving, the device still has a low or unstable signal strength, use
the ReX radio signal range extender.
Install LeaksProtect in the place of potential leakage: on the floor under
the bath, sink, washing machine, etc.
Do not install the detector:
- outside the premises (outdoors);
- nearby any metal objects or mirrors causing attenuation and screening of the signal;
- within any premises with a temperature beyond the range of permissible limit;
- on conductive surfaces;
- closer than 1 m to the hub.
Detector Testing
When the liquid gets on the detector contacts, it closes the electrical circuit. It is enough to close one contact pair to activate the alarm.
- To check LeaksProtect, close one contact pair with a wet finger for 3 seconds (the delay prevents false triggering). If water is detected, the detector LED will light up red for 1 second. then dry them up.
Maintenance
- Check the LeaksProtect operational capability on a regular basis. We recommend cleaning the detector contacts as it gets dirty, at least, once every 2-3 months. Use an alcohol solution for cleaning the contacts.
- Clean the detector body from dust, spider webs and other contaminants as they appear: they can conduct electricity and cause false actuation. Use a soft dry napkin suitable for equipment maintenance.
- Do not use any substances containing alcohol, acetone, gasoline and other active solvents for cleaning the detector body.
- The batteries installed in the detector ensure up to 5 years of autonomous operation on average (with the inquiry frequency by the hub of 1 minutes). If the detector batteries are low, the security system sends the notification and the detector LED smoothly lights up and goes out green every hour, if the device is triggered.
- To replace the batteries, turn off the detector, loosen the screws and remove the LeaksProtect front panel. Change the batteries with new ones type AAA, adhering to polarity.
How long Ajax devices operate on batteries, and what affects this Battery replacement
Tech specs
Complete Set
- LeaksProtect
- Batteries AAA (pre-installed) – 2 pcs
- Quick Start Guide
Warranty
Warranty for the “AJAX SYSTEMS MANUFACTURING” LIMITED LIABILITY COMPANY products is valid for 2 years after the purchase and does not apply to the pre-installed battery.
Technical support: support@ajax.systems
Read User Manual Online (PDF format)