Shenzhen Fine Offset Electronics Co GW2000 Weather Station User Guide
- June 8, 2024
- Shenzhen Fine Offset Electronics Co
Table of Contents
Fine Offset Electronics Co GW2000 Weather Station
User Guide
GW2000 Weather Station
5| Temp. &Humidity
Sensor
---|---
4| Network LED
3| Ethernet socket
2| DC Socket
I| Reset button
No| Description
Please choose method A,B or C to start the setup. we recommend:
- Method C to be used first
- Method B to be used if Method C doesn’t work for you.
- Method A to be used if you don’t have an ethernet port but have a mobile phone only.
Attention:
Our product is continuously changing and improving, particularly online
services and associated applications. To download the latest manual and
additional help, please contact us at
support@ecowitz.com or
support.eu@ecowitt.net (EU/UK).
Manufacturer:
ShenZhenShi OuSaiTeDianZi YouXianGongSi Add: C Dong 4 Ceng A.
Minzhujiujiugongyecheng AQu. Xihuanlu. Shajingjiedao. Baoanqu Shenthen.
Guangdong 518101. CN E-mail: support@ecowitt.com
support.eu@ecowitt.net (EU/UK)
UK representative
UK AR
HUA TENG LIMITED 3 Glass Street, Hanley, Stoke On Trent, ST1 2ET United
Kingdom
EC representative
EC REP
AC WORKS CONSULTING SrI Via Vilfredo Pareto 125,47521 Casena(FC),ITALY
https://www.ecowitt.com/support/download/178
- Please scan the QR code to read English manual and keep it for future reference
Instruction manuals
https://www.ecowitt.com/support/download/178
Compact and Built to Iast Feature
All in one
Weather Station
Temperattre. humidity. wind direction and speed. light and UV levels Dud-
Power Supply
Solar Power Autonomy & Backup Battery
Supports a bundle of sensors
Those already developed sensors or to be developed future sensors are all
supported.
Haptic Rainfall Sensor
More accuracy with Anti-vibration design
Light compact yet robust IPXS
install it outdoors and let it do its weather station magic
Near – Zero maintenance
All-in-one weather station with no moving parts
Get Live data Maundy
View live data on Ecowitt app or at EcoWitt.net
Easy Integration to r patty
With its unique data exdiange protocol, it can be integrated easily with r
party systems.
Get alert emails
on your own defined alert condition, mails an be triggered to notify you the
alert
Easy Integration to 3 party
Data on be picked up&received through Hub GW2000 in 150m range
Replaceable Temperature & Humidity Sensor
While compactithe entire
structure of WittBoy is built to be robust and designed to withstand the test
of time. The Temperature and Humidity Sensor Kit can be replaced whenever
required.
Paired with W-Fi Hub GW2000
Your private weather
station will pick up data of temperature, humidity, wind direction and speed,
light and UV levels, as well as rainfall, and report it to you through its APP
or the ecowitt.net website.
or your own defined
server
Specification
Measurement specification
Measurement | Range | Accuracy | Resolution |
---|---|---|---|
Wind speed | 0-40m/s | <I0m/s,+/-0.5m/s 10m/s,+/-5% | O. 1 M/S |
Wind direction | 0-359° | <4m/s,TBA 10m/s,±10° | I° |
Tern perature | -40-60°C | ±0.5°C | 0.1°C |
Humidity | I —99% | ±5% | I% |
Light | 0-300KIux | ± I 5% | I OKlux |
UVI | HI5 | ±2 | 1 |
Rain | 0-9999 | ±10% | O. I mm |
Power consumption
Anemometer sensor (main) | Anemometer sensor (backup) |
---|---|
Solar panel (built-in) 6.5V/4mA(Integrated) | 2 x AA I.5V battery (not |
included,recommended to use Lithium none rechargeable batteries)
FCC WARNING
This device complies with part 15 of the FCC Rules. Operation is subject to
the following two conditions: (1) this device may not cause harmful
interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation. Any changes or
modifications not expressly approved by the party responsible for compliance
could void the user’s authority to operate the equipment.
NOTE: This equipment has been tested and found to comply with the limits
for a Class B digital device, pursuant to Part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates, uses and
can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not
occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help. To maintain compliance with FCC’s RF Exposure guidelines, This equipment should be installed and operated with minimum distance between 20cm the radiator your body: Use only the supplied antenna.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>