HIKVISION DS-PK1-E-WE Wireless LED Keypad User Manual
- June 8, 2024
- Hikvision
Table of Contents
DS-PK1-E-WE Wireless LED Keypad
User Manual
DS-PK1-E-WE Wireless LED Keypad
Diagram References
©2020 Hangzhou Hikvision Digital Technology Co., Ltd. All rights reserved.
About this Manual
The Manual includes instructions for using and managing the Product. Pictures,
charts, images and all other information hereinafter are for description and
explanation only. The information contained in the Manual is subject to
change, without notice, due to firmware updates or other reasons. Please find
the latest version of this Manual at the Hikvision website
(https://www.hikvision.com/). Please use this Manual with the guidance and
assistance of professionals trained in supporting the Product.
and other Hikvision’s trademarks and logos are the properties of Hikvision in
various jurisdictions. Other trademarks and logos mentioned are the properties
of their respective owners.
Disclaimer
TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW, THIS MANUAL AND THE PRODUCT
DESCRIBED, WITH ITS HARDWARE, SOFTWARE AND FIRMWARE, ARE PROVIDED “AS IS” AND
“WITH ALL FAULTS AND ERRORS”. HIKVISION MAKES
NO WARRANTIES, EXPRESS OR IMPLIED, INCLUDING WITHOUT LIMITATION,
MERCHANTABILITY, SATISFACTORY QUALITY, OR FITNESS FOR A PARTICULAR PURPOSE.
THE USE OF THE PRODUCT BY YOU IS AT YOUR OWN RISK. IN NO EVENT WILL HIKVISION
BE LIABLE TO YOU FOR ANY SPECIAL, CONSEQUENTIAL, INCIDENTAL, OR INDIRECT
DAMAGES, INCLUDING, AMONG OTHERS, DAMAGES FOR LOSS OF BUSINESS PROFITS,
BUSINESS INTERRUPTION, OR LOSS OF DATA, CORRUPTION OF SYSTEMS, OR LOSS OF
DOCUMENTATION, WHETHER BASED ON BREACH OF CONTRACT, TORT (INCLUDING
NEGLIGENCE), PRODUCT LIABILITY, OR OTHERWISE, IN CONNECTION WITH THE USE OF
THE PRODUCT, EVEN IF HIKVISION HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH
DAMAGES OR LOSS.
YOU ACKNOWLEDGE THAT THE NATURE OF INTERNET PROVIDES FOR INHERENT SECURITY
RISKS, AND HIKVISION SHALL NOT TAKE ANY RESPONSIBILITIES FOR ABNORMAL
OPERATION, PRIVACY LEAKAGE OR OTHER DAMAGES RESULTING FROM CYBER-ATTACK,
HACKER ATTACK, VIRUS INSPECTION, OR OTHER INTERNET SECURITY RISKS; HOWEVER,
HIKVISION WILL PROVIDE TIMELY TECHNICAL SUPPORT IF REQUIRED.
YOU AGREE TO USE THIS PRODUCT IN COMPLIANCE WITH ALL APPLICABLE LAWS, AND YOU
ARE SOLELY RESPONSIBLE FOR ENSURING THAT YOUR USE CONFORMS TO THE APPLICABLE
LAW. ESPECIALLY, YOU ARE RESPONSIBLE, FOR USING THIS PRODUCT IN A MANNER THAT
DOES NOT INFRINGE ON THE RIGHTS OF THIRD PARTIES, INCLUDING WITHOUT
LIMITATION, RIGHTS OF PUBLICITY, INTELLECTUAL PROPERTY RIGHTS, OR DATA
PROTECTION AND OTHER PRIVACY RIGHTS. YOU SHALL NOT USE THIS PRODUCT FOR ANY
PROHIBITED END-USES, INCLUDING THE DEVELOPMENT OR PRODUCTION OF WEAPONS OF
MASS DESTRUCTION, THE DEVELOPMENT OR PRODUCTION OF CHEMICAL OR BIOLOGICAL
WEAPONS, ANY ACTIVITIES IN THE CONTEXT RELATED TO ANY NUCLEAR EXPLOSIVE OR
UNSAFE NUCLEAR FUEL-CYCLE, OR IN SUPPORT OF HUMAN RIGHTS ABUSES.
IN THE EVENT OF ANY CONFLICTS BETWEEN THIS MANUAL AND THE APPLICABLE LAW, THE
LATER PREVAILS.
This product and – if applicable – the supplied accessories too are
marked with “CE” and comply therefore with the applicable harmonized European
standards listed under the EMC Directive 2014/30/EU, the RE Directive
2014/53/EU, the RoHS Directive 2011/65/EU.
2012/19/EU (WEEE directive): Products marked with this symbol cannot be
disposed of as unsorted municipal waste in the European Union. For proper
recycling, return this product to your local supplier upon the purchase of
equivalent new equipment, or dispose of it at designated collection points.
For more information see: www.recyclethis.info
replacement of a battery with an incorrect type that can defeat a
safeguard (for example, in the case of some lithium battery types);
- disposal of a battery into fire or a hot oven, or mechanically crushing or cutting of a battery, that can result in an explosion;
- leaving a battery in an extremely high temperature surrounding environment that can result in an explosion or the leakage of flammable liquid or gas; and
- a battery subjected to extremely low air pressure that may result in an explosion or the leakage of flammable liquid or gas
**** 2006/66/EC (battery directive): This product contains a battery that cannot be disposed of as unsorted municipal waste in the European Union. See the product documentation for specific battery information. The battery is marked with this symbol, which may include lettering to indicate cadmium (Cd), lead (Pb), or mercury (Hg). For proper recycling, return the battery to your supplier or to a designated collection point. For more information see:www.recyclethis.info
Introduction
Appearance CAUTION
RISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECT TYPE.
REPLACEMENT OF A BATTERY WITH AN INCORRECT TYPE THAT CAN DEFEAT A SAFEGUARD.
CAUTION
CHEMICAL BURNING DANGER DO NOT SWALLOW THE BATTERY KEEP NEW AND USED BATTERIES
AWAY FROM THE CHILDREN.
IF YOU THINK BATTERIES MIGHT HAVE BEEN SWALLOWED OR PLACED INSIDE ANY PART OF
THE BODY, SEEK IMMEDIATE MEDICAL ATTENTION.
CAUTION
DISPOSE OF USED BATTERIES ACCORDING TO THE INSTRUCTIONS AND LOCAL REGULATION.
Indication
LED Indication Description
**** | With Fault | Solid orange for 3 s and then off |
---|---|---|
No Fault | Off | |
Tampering Alarm | Solid red | |
Event Alarm | Flashing red | |
No Alarm | Off |
Note: Event Alarm Priority > Tampering Alarm Priority
| Armed| Solid blue for 5 s
Arming Failed| Blue turns Off
Disarmed| Green flashes 2 times
Disarming Failed| Green turns Off
| Enrollment| Flashing red and green: Enrolling
Green flashes 7 times: Enrolled
---|---|---
Signal Strength| Solid green for 3 s: Strong
Solid orange for 3 s: Medium
Solid red for 3 s: Weak
Flashing red for 3 s: Disconnected
Find Me| Flashing green for 20 s: Operating
Power On| Solid green for 1 s: Powered on
Back Light
- The back light is on by default, you can set the On/Off schedule on the web client of the control panel. Refer to the user manual of control
- It turns off when there is no key operation for more than 10 s.
- If the keypad is not enrolled to the control panel, the back light is off.
Enrollment
- Remove the screw on the bottom of the keypad.
- Disassemble the keypad and remove the rear panel.
- Power on the security control panel.
- Log in the Hik-Connect APP and tap the icon “+” . Scan the QR code or input the control panel serial No. to add the control panel.
- Enroll the peripheral locally, with OR code, or with serial No..
Enroll the Peripheral Locally
- In the APP, tap the “Enrollment Mode” button on the control panel page to make the control panel enter the enrollment status.
- Push the power switch of the peripheral to on, and it will be automatically enrolled to the control panel.
Enroll the Peripheral with QR Code or Serial No.
- In the APP, tap the icon “+”and scan the QR code or enter the serial No. on the peripheral.
- Push the power switch of the peripheral to on, and it will be automatically enrolled to the control panel.
Note: for re-enrollment, you need to hold the tamper button while
powering the peripheral on simultaneously.Remove the screw on the bottom of the
keypad. Disassemble the keypad and remove the rear panel.
Scan the QR code on the rear panel of the keypad. Push the power switch to ON.
Installation
Note: The additional force shall be equal to three times the weight of
the equipment but not less than 50N. The equipment and its associated mounting
means shall remain secure during the installation. After the installation, the
equipment, including any associated mounting plate, shall not be damaged.
Check signal strength and select installation place
Enter the signal checking mode by operating on the control panel.
Signal LED turns green for 3 s: Strong.
Signal LED turns orange for 3 s: Medium.
Signal LED turns red for 3 s: Weak.
Signal LED flashes red for 3 s: Disconnected.
-
Secure the rear panel on the wall with four supplied screws.
-
Attach the front panel onto the rear panel. CAUTION
IF THE BATTERY COMPARTMENT DOES NOT CLOSE SECURETLY, STOP USING THE PRODUCT AND KEEP IT AWAY FROM CHILDREN. -
Tighten the screw on the bottom to complete the
Command
The keypad command is shown as follows.
Events | Codes | Notes |
---|---|---|
Away arm | Away arming for all areas: User password + Away |
Away arming for specified area: User password + # + Area
No.(1,2.3.4.5.6.7.8.9.010.011.012….) + away| -The keypad does not display area
No. greater than 9.
-If the area No. is greater than 9, enter ” OXX”for the No..”0″indicates tens digits, and “XX”indicates the actual area No.
-If the selected area is not related to the keypad,the back light of “0” will
Stay arm| Stay arming for all areas: User password + Stay|
Stay arming for specified area:
User password + # + Area
No.(1,2.3.4.5.6.7.8.9.010.011.012….) + Stay| -The keypad does not display area
No. greater than 9.
-If the area No. is greater than 9, enter ” OXX”for the No..”0″indicates tens digits, and “XX”indicates the actual area No.
-If the selected area is not related to the keypad,the back light of “0” will flashes three times.
Disarm| Disarming for all areas: User password + Disarm|
Disarming for specified area:
User password + # + Area
No.(1,2.3.4.5.6.7.8.9.010.011.012….) + Disarm| -The keypad does not display
area No. greater than 9.
-If the area No. is greater than 9, enter ” OXX”for the No..”0″indicates tens digits, and “XX”indicates the actual area No.
-If the selected area is not related to the keypad,the back light of “0” will flashes three times.
Clear alarm| User Password+Hold Disarm|
Fire| Hold “1/Fire Alarm” for 3 s| The Buzzer will beep three times for
failure operation.
PA| Hold “2/Panic Alarm” for 3 s| The Buzzer will beep three times for failure
operation.
Medical| Hold “3/Medical” for 3 s| The Buzzer will beep three times for
failure operation.
Duress| (Duress Code)+disarm| You can set the duress code on the web client of
the control panel. Refer to the user manual of control panel for details.
Output| User Password+Output+relay
No.(1,2.3.4.5.6.7.8.9.010.011.012….)+ #| -If the relay No. is greater than 9,
enter ” OXX” for the No..”0″indicates tens digits, and “XX”indicates the
actual relay No.
– A successful command execution implement an operation “Off” or “On”.
Specification
The keypad technical specification is shown as follows.
Wireless Keypad
RF| Speed| 42Kbps
Frequency| 868.0MHz
Method| 2GFSK
Distance| 1200m (open area)
Transmition power| 13 dbm
Interface| Tamper switch| 1, front and rear panel tamper-proof
Wireless module| For wireless communication
Power switch| Power on/off
Buzzer| 1
Display| Indicator| 4:fault (orange), enrollment/signal (red/green),
arming(red/green/blue), and alarm (red)
Backlight| white
Key| Number key| 10: 0 to 9
Function key| 5:*, #, stay arming, away arming, disarming, and
Operation
Environment| Humidity| 10% to 90%
Temperature| – 10°C to +55°C
Appearance| Color| White/Black
Dimension(W x H x D)| 140 x 86 x 22 mm,
Installation| Installation| Screw mounting
Power Supply| Power Supply| 1.5 VDC, four AA baterries, standby time more than
two years
Weight| Weight without batteries| 151 g, and 23 g each battery
Specification
The keypad technical specification is shown as follows.
Wireless Keypad
RF| Speed| 42Kbps
Frequency| 868.0MHz
Method| 2GFSK
Distance| 1200m (open area)
Transmition power| 13 dbm
Interface| Tamper switch| 1, front and rear panel tamper-proof
Wireless module| For wireless communication
Power switch| Power on/off
Buzzer| 1
Display| Indicator| 4:fault (orange), enrollment/signal (red/green),
arming(red/green/blue), and alarm (red)
Backlight| white
Key| Number key| 10: 0 to 9
Function key| 5:*, #, stay arming, away arming, disarming, and
Operation Environment| Humidity| 10% to 90%
Temperature| – 10°C to +55°C
Appearance| Color| White/Black
Dimension(W x H x D)| 140 x 86 x 22 mm,
Installation| Installation| Screw mounting
Power Supply| Power Supply| 1.5 VDC, four AA baterries, standby time more than
two years
Weight| Weight without batteries| 151 g, and 23 g each battery
Operation
Keypad Status
Working Status| The keypad will enterthe sleep status while meeting
thefollowing conditions:
RF data transmission key operation keypad tamperingalarm polling Beeping LED
indication
---|---
Sleep Status| The keypad will enterthe sleep status while meetingthe
followingconditions: No RF data transmission
No key operation for more than 10 s No keypad tampering alarm No polling No
beeping
No LED indication
Enrollment Status| While the keypad is enrolled toa control panel, itenters
the enrollment status. Only if the keypad is enrolled,the key operation and
status indication take effects.
Free Status| There is no area related tothe keypad. The key and back light do
not works.
Operation Interval
The interval between the operations (successful or failed) should be more than
3 s.
The continuous operation of the key should be in 10 s.
Keypad Lock
The Key pad will be locked after 3 to 5 failure authentication attempts.You
can set the lock time on the web client of the control panel Arming Process
Pre-delay
Indication:
The arming LED turns flashing blue Fault Checking
Indication:
The arming LED turns flashing orange Confirm the operation by press the Arm
key
Exit Delay
Indication:
Arming LED turns flashing blue, and the buzzer indicates exit delay.
Arm Directly
Press the Arm key to arm the device.
Indication:
Armed: arming LED solid blue for 5 s. Buzzer beeps twice.
Arming failed: Buzzer beeps three time.
Disarm
Press the Disarm key to disarm the device.
Indication:
Armed: Buzzer beeps twice.
Arming failed: Buzzer beeps three time.
No Instant Operation
The count down is finished.
Indication:
Armed: arming LED solid blue for 5 s. Buzzer beeps twice.
Arming failed: Buzzer beeps three time.
50131-1:2006+A2:2017
EN 50131-3:2009
EN 50131-5-3:2017
Security Grade(SG) 2
Environmental Class(EC)
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>