EYE LIGHTING ELI ConV2 Emergency Pole Mounted LED Luminaire Instruction Manual

June 4, 2024
EYE LIGHTING

ELI ConV2 Emergency
Installation Instructions

Electrical Wiring of the ConV2 Emergency LED Fixture

Option: 3-Phase AC wiring configuration is available upon request.

Important-Safety

This luminaire must be installed by a licensed electrician, following these installation instructions. Before carrying out any installation or maintenance on this luminaire, ensure that the main supply is fully isolated. High voltages greater than the mains voltage can be present during operation.
Any inadequate installation might cause falling, electric shock, fire, or other hazards.

Ensure only qualified personnel inspect and maintains the luminaire. Excessive build-up of foreign material from outer surfaces should be cleaned to maintain the performance of the luminaire. The battery and light source is non-user replaceable. Contact manufacturer / supplier. Do not modify the luminaire, disassemble or replace any component without confirming with the supplier first. Do not touch the power supply when the luminaire is operating.

If the external flexible cable of the luminaire is damaged, it should only be replaced by the supplier, a service agent or a qualified person.

Emergency Operation Instructions

ConV2 Emergency can operate as maintained and non-maintained emergency mode.

Self-contained Battery
Type: Rechargeable Lithium Iron Phosphate (LiFePO4)
Rated voltage: 12.8 Vdc
Capacity: 6000 mAh
76.8 Wh
Duration (discharge time): >180 min
ta: 60°C max

Charge / input characteristics

Charge time ≥16 hours
Charge voltage limit 14.8 Vdc

Discharge / output characteristics

Discharge current 2.0 A max
Output voltage / current 26 – 40 Vdc / 500 mA

constant current (with load) 50 Vdc (no load)
Output power| 20 W max
Deep discharge  protection (V)| 10 ±0.2 Vdc

Battery wiring: Red (+), Black (-)
Caution: do not expose the battery to fire or dispose of it in the fire. Avoid shorting, excessive physical shock, and vibration.
To guarantee the rated discharge time, please charge the battery for at least 16 hours.
If the luminaire is ever connected to mains voltage before installation (days or weeks beforehand), the lens cover must be opened following the Access to internal testing facilities instructions. In the internal gear, the battery supply connector must be disconnected and reconnected to the Emergency controller in order to interrupt the discharge cycle, avoiding the Lithium battery to remain fully discharged for a long period of time. The battery is supplied 50% charged from the factory.
EYE Lighting Australia Pty Ltd
15 Industrial Avenue
Wacol QLD 4076

For the latest product information visit the EYE Lighting Australia website

Manually operated testing facilities
ConV2 Emergency is supplied with a test switch and a visual LED indicator.
During charging mode, press (down) test switch to replicate emergency mode. Release the test button to recover charging mode.
Visual LED indicator – green: charging the battery and fully charged. Visual LED indicator – if the battery is discharging, disconnected, or not being charged correctly (general malfunction).
A discharge cycle shall be completed at least once every 6 months. Continuous charging time cannot exceed 6 months.
After installation, the luminaire classification marking on the external label of the product shall be  completed according to AS/NZS 60598.2.22, showing:

TYPE
MODE OF OPERATION
FACILITIES
DURATION OF
EMERGENCY MODE| X: self-contained
0: non-maintained
1: Maintained
A: including test device
B: including remote rest mode
C: including inhibiting mode
D: high-risk task-area luminaire
180 : 3 hours
---|---

Access to internal testing facilities

Only if required to access the test switch remove the lens cover by unscrewing the 17 x M4 screws. When repositioning the lens cover follow the tightening sequence and torque for the screws to ensure IP protection.
Please note warranty will not cover any damage due to incorrect tightening or positioning of the PC lens cover.

Scan for PDF Version

Fixture weight: 5.1 Kg Max.

EYE Lighting Australia Pty Ltd
15 Industrial Avenue
Wacol QLD 4076
For the latest product information visit the EYE Lighting Australia website

Tel: +61 (0) 7 3335 3555
Fax: +61 (0) 7 3335 3533
Email: info@eli.com.au
www.eyelighting.com.au
CONV2EM 27.07.22

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals