EYE LIGHTING JL-103B Photocell Instructions

June 9, 2024
EYE LIGHTING

Wiring Instructions for JL-103B Photocell

JL-103B Photocell

The Correct Wiring for JL-103B Photocell

  • JL-103B RED Load wire connected with LED fixture ‘L’ terminal
  • Then LED fixture ‘N’ terminal connect with both JL-103B Black Neutral wire and AC input Blue Neutral wire
  • Then JL-103B White Line wire connect with AC input Brown Active wire
  • Then LED fixture ‘GND’ terminal connect with the AC input Green/Yellow Earth wire

How to Correctly Wire JL-103B Photocell

EYE LIGHTING JL 103B Photocell

The most common Incorrect Wiring for JL-103B Photocell:

  • Red Load wire of JL-103B directly connected to AC input Active wire
  • White Line wire of JL-103B connected to the LED fixture ‘L’ terminal

Results of the Incorrect Wiring:

  • The Lighting fixture will be ON/OFF every couple of seconds

Incorrect Wiring

EYE LIGHTING JL 103B Photocell - fig

Safety Note: This PE Cell must be installed by a licensed electrician, following the installation instructions. Before carrying out any installation or maintenance on this PE Cell, ensure that the mains supply is fully isolated. Any inadequate installation might cause falling, electric shock, fire, or other hazards. Do not modify the PE Cell. Do not touch the PE Cell when the luminaire is operating. Installer shall bear the consequences if the PE Cells are not secured in a proper manner. Any modification on the
PE Cells or luminaire to which PE Cell is connected will void the warranty.

1800 635 383
www.eyelighting.com.au
JLWIR13323