ACME Flandina 12 12pcs 8W CW LED Light Sources User Manual

June 9, 2024
acme

ACME logo

User Manual
Please rede the instruction carefully before use

Safety Instructions

Please read the instruction carefully which includes important information about the installation, usage and maintenance.
WARNING

Please keep this User Guide for future consultation. If you sell the unit to another user, be sure that they also receive this instruction manual.
Important:
Damages caused by the disregard of this user manual are not subject to warranty. The dealer will not accept liability for any resulting defects or problems.

  • Unpack and check carefully to ensure that there is no transportation damage before using the unit.
  • This product is for indoor use only. Use only in a dry location.
  • DO install and operate by qualified operator.
  • DO NOT allow children to operate the fixture.
  • Use safety chain when fixing the unit. Handle the unit by carrying its base instead of head only.
  • The unit must be installed in a location with adequate ventilation, at least 50cm from adjacent surfaces.
  • Be sure that no ventilation slots is blocked, otherwise the unit will be overheated.
  • Before operation, ensure that you are connecting this product to the proper voltage in accordance with the specifications in this manual or on the product’s specification label.
  • It’s important to ground the yellow/green conductor to earth in order to avoid electric shock.
  • Minimum ambient temperature TA: 0 ℃. Maximum ambient temperature TA: 40℃. Do not operate this product at a lower or higher temperature.
  • DO NOT connect the device to any dimmer pack.
  • Keep flammable materials away from the fixture while operating to avoid fire hazard.
  • Make sure the power cord is not crimped or damaged; replace it immediately if damaged.
  • Unit’s surface temperature may reach up to 65℃. DO NOT touch the housing bare-handed during its operation.
  • Avoid any flammable liquids, water or metal from entering the unit. Once it happens, cut off the mains power immediately.
  • DO NOT operate in a dirty or dusty environment. DO clean the fixture regularly.
  • DO NOT touch any wire during operation as there might be a hazard of electric shock.
  • Avoid entanglement of the power cord with other wires.
  • The minimum distance to objects/surface must be more than 0.5 meters.
  • In the event of serious operating problem, stop using the unit immediately.
  • Never turn on and off the unit time after time.
  • The housing, the lenses, or the ultraviolet filter must be replaced if they are visibly damaged.
  • DO NOT open the housing as there are no user serviceable parts inside.
  • DO NOT attempt to operate this unit if it becomes damaged. DO NOT attempt any repairs yourself. Repairs carried out by unskilled people can lead to damage or malfunction. Please contact the nearest authorized technical assistance center if needed.
  • Disconnect this product from its power source before servicing.
  • DO use the original packaging if the device is to be transported.
  • Avoid direct eye exposure to the light source while the product is on.
  • DO NOT operate this product if you see damage on the housing, shields, or cables. Have the damaged parts replaced by an authorized technician at once.

Installation:
The fixture should be fixed on the clamp. Always ensure that the unit is firmly fixed to avoid vibration and slipping off during operation. Ensure that the trussing or area of installation must be able to hold 10 times the weight without any deformation. Always install a safety cable that can hold at least 12 times the weight of the fixture when installing. DO install and operate by qualified operator. It must be installed in a place where there is out of the reach of people.

Technical Specifications

Power Voltage: 100-240V~ 50/60Hz
Power Consumption: 55W
Light Source: 12x3W WW LED
Beam Angle: 4°
Dimming/Strobe: Smooth dimming from 0-100%; outstanding strobe effect with variable speed
Control: DMX Channel: 1 6/14/5 Channels
Control Mode: DMX512, RDM, Primary/Secondary Firmware Upgrade via DMX link
Construction: Display: OLED display
Data In/Out: 3-pin XLR (5-pin XLR is optional)
Power In/Out: Power Connector in/out
Protection Rating: IP20
Features: 12 pcs LED pixel control
High efficiency LED lens, 2700K golden yellow light, beam angle up to 4° Suitable for project installation and touring performances
Double mounting brackets design and the adjustable angle reaches 180 degrees in both direction
Dimension/ Weight: 998x102x106mm, 3.4kgs 39.3″x4″x4.2″in, 7.5lbsACME
Flandina 12 12pcs 8W CW LED Light Sources - fig.

Photometric Diagram:

Control Panel

  1. DISPLAY: To show the various menus and the selected functions

  2. Button:
    MENU| To select the programming functions
    ---|---
     DOWN| To go forward in the selected functions
     UP| To go backward in the selected functions
    ENTER| To confirm the selected functions

  3. DMX IN:
    For DMX512 operation, use 3-pin XLR cable to link the unit and controller (5-pin XLR is optional)

  4. DMX OUT:
    For DMX512 operation, use 3-pin XLR cable to link the next units (5-pin XLR is optional)

  5. POWERCON IN: To connect to supply power

  6. POWERCON OUT: To connect to the next unit

How to Set the Unit

4.1 Main Function
Turn on the unit, press the MENU button into menu mode, and press the UP/DOWN button until the required function is shown on the monitor. Select the function by pressing the ENTER button.
Use the UP/DOWN button to choose the submenu, press the ENTER button to store and automatically return to the last menu. Press the MENU button or let the unit idle 30 seconds to exit menu mode.
The main functions are shown below:

ACME Flandina 12 12pcs 8W CW LED Light Sources - fig.2

DMX Settings
To select DMX Settings, press the ENTER button to confirm, use the UP/DOWN button to select DMX Address, Channel Mode, No DMX Status or View DMX Value.
DMX Address
To select DMX Address, press the ENTER button to confirm. Use the UP/DOWN button to adjust the address from 001 to 497/499/508, press the ENTER button to store. Press the MENU button back to the last menu or let the unit idle 30 seconds to exit menu mode.
Channel Mode
To select Channel Mode, press the ENTER button to confirm. Use the UP/DOWN button to select Mode1(16), Mode2(14) or Mode3(5), press the ENTER button to store. Press the MENU button back to the last menu or let the unit idle 30 seconds to exit menu mode.
No DMX Status
To select No DMX Status, press the ENTER button to confirm. Use the UP/DOWN button to select Hold(fixture continues to obey the last command it received Via DMX if DMX signal stops), Blackout(fixture blacks out if DMX signal stops) or Manual(the fixture will automatically read the DMX value in the “Manual Test” menu for operation after selecting this mode), press the ENTER button to store. Press the MENU button back to the last menu or let the unit idle 30 seconds to exit menu mode.
View DMX Value
To select View DMX Value, press the ENTER button to confirm. Use the UP/DOWN button to view the DMX channel value. Press the MENU button back to the last menu or let the unit idle 30 seconds to exit menu mode.
Fixture Settings
To select Fixture Settings, press the ENTER button to confirm, use the UP/DOWN button to select Dimmer Curve, Dimmer Speed or Invert Pixel Order.
Dimmer Curve
To select Dimmer Curve, press the ENTER button to confirm. Use the DOWN/UP button to select Linear, Square Law, Inv SQ Law or S Curve, press the ENTER button to store. Press the MENU button back to the last menu or let the unit idle 30 seconds to exit menu mode.
Dimmer Modes

ACME Flandina 12 12pcs 8W CW LED Light Sources - fig3

Optically Linear: The increase in light intensity appears to be linear as DMX value is increased.
Square Law: Light intensity control is finer at low levels and coarser at high levels.
Inverse Square Law: Light intensity control is coarser at low levels and finger at high levels.
S-Curve: Light intensity control is finger at low levels and high levels and coarser at medium levels.
Dimmer Speed
To select Dimmer Speed, press the ENTER button to confirm. Use the UP/DOWN button to select Fast or Smooth, press the ENTER button to store. Press the MENU button back to the last menu or let the unit idle 30 seconds to exit menu mode.
Invert Pixel Order
To select Invert Pixel Order, press the ENTER button to confirm. Use the UP/DOWN button to select No or Yes, press the ENTER button to store. Press the MENU button back to the last menu or let the unit idle 30 seconds to exit menu mode.
Display Settings
To select Display Settings, press the ENTER button to confirm, use the UP/DOWN button to select Display Invert, Temperature Unit or Language.
Display Invert
Select Display Invert, press the ENTER button to confirm, present mode will blink on the display, use the UP/DOWN button to select No (normal display) or Yes (invert display), press the ENTER button to store. Press the MENU button back to the last menu or let the unit idle 30 seconds to exit menu mode.
Temperature Unit
Select Temperature Unit, press the ENTER button to confirm. Use the UP/DOWN button to select ℃ or ℉, press the ENTER button to store. Press the MENU button back to the last menu or let the unit idle 30 seconds to exit menu mode.
Language
Select Language, press the ENTER button to confirm, present mode will blink on the display, use the UP/DOWN button to select English or Chinese. Press the MENU button back to the last menu or let the unit idle 30 seconds to exit menu mode.
Auto Test
To select Auto Test, press the ENTER button to confirm, the unit will run built-in programs to automatically test its functions. Press the MENU button back to the last menu or exit menu mode after auto test.
Manual Test
To select Manual Test, press the ENTER button to confirm, use the UP/DOWN button to select Mode, Clear, White1……White12, Strobe or White, Shutter Dimmer, press the ENTER button to confirm, use the UP/DOWN button to adjust the value from 0 to 255, press the ENTER button to store. Press the MENU button back to the last menu or let the unit idle 30 seconds to exit menu mode.
(The fixture will return to the previous DMX state after exiting Manual Mode menu and the Manual Test parameters will be automatically saved after power off and restart.)
Information
To select Information, press the ENTER button to confirm, use the UP/DOWN button to select Fixture Use Hour, LED Use Hour, Temperatue, Firmware Version, RDM UID or Error Logs.
Fixture Use Hour
Select Fixture Use Hour, press the ENTER button to confirm, fixture use hour will show on the display, press the MENU button to exit.
LED Use Hour
To select LED Use Hour, press the ENTER button to confirm, use the UP/DOWN button to select Total LED Hour, LED On Hour or LED Hours Reset, press the ENTER button to store. To select LED Hours Reset, press the ENTER button to confirm. Use the UP/DOWN button to select No or Yes, press the ENTER button to confirm. To select Yes, press the ENTER button to confirm, use the UP/DOWN button to set the password 050 to reset the LED hours, press the ENTER button to store. Press the MENU button back to the last menu or exit menu mode let the unit idle 30 seconds.
Temperature
Select Temperature, press the ENTER button to confirm, use the UP/DOWN button to select LED or PCBA, press the ENTER button to confirm, fixture’s current temperature and max temperature of the LED or PCBA will show on the display, press the MENU button to exit.
Firmware Version
Select Firmware Version, press the ENTER button to confirm, firmware version will show on the display, press the MENU button back to exit.
RDM UID
Select RDM UID, press the ENTER button to confirm, RDM UID will show on the display, press the MENU button back to exit.
Error Logs
Select Error Logs, press the ENTER button to confirm. Use the UP/DOWN button to select Fixture Errors or Reset Error Log, press the ENTER button to store. Select Reset Error Log, press the ENTER button to confirm. Use the UP/DOWN button to select No or Yes, press the ENTER button to store.
Select Yes, press the ENTER button to confirm. Use the UP/DOWN button to set the password 050, press the ENTER button to store. Press the MENU button back to the last menu or let the unit idle 30 seconds to exit menu mode.
Factory Restore
Select Factory Restore, press the ENTER button to confirm, use the UP/DOWN button to select No (normal) or Yes (the fixture will reset to factory settings), press ENTER button to store. Press the MENU button to exit.

RDM FUNCTIONS

Select the MANUFACTURER menu to display the manufacturer of the fixture.
Select the SOFTWARE VERSION menu and the program version number of the fixture will be displayed.
Select the DMX START ADDRESS menu to change the DMX 512 address (001-512).
Select the DEVICE MODEL DESCRIPTION menu to display the model of the fixture.
Select the DEVICE LABEL menu to change the model of the fixture.
Select the DMX PERSONALITY menu to set the channel mode of the fixture (1 6/1 4/5 channel).
Select the DMX PERSONALITY DESCRIPTION menu to display the current channel mode of the fixture.
Select the DEVICE HOURS menu to display the running time of the fixture.
Select the RESET DEVICE menu, the WARM RESET/COLD RESET option will be displayed. When WARM RESET is selected, the fixture will start a warm reset, and exit when COLD RESET is selected.
4.2 Home Position Adjustment
Press the MENU button into menu mode, then press the ENTER button for about 3 seconds into offset mode to adjust the home position. Select the function by pressing the ENTER button. Use the UP/DOWN button to choose the submenu, press the ENTER button to store and automatically return to the last menu. Press MENU button to exit.

Frequency(Hz)
Enter offset mode, Select Frequency(Hz), press the ENTER button to confirm, the present position will blink on the display, use the UP/DOWN button to offset the value from 1072 to 1327, press the ENTER button to store. Press the MENU button to exit.
White1
Enter offset mode, select White1, press the ENTER button to confirm, the present position will blink on the display, use the UP/DOWN button to offset the value from 0 to 255, press the ENTER button to store. Press the MENU button to exit. ……
White12
Enter offset mode, select White12, press the ENTER button to confirm, the present position will blink on the display, use the UP/DOWN button to offset the value from 0 to 255, press the ENTER button to store. Press the MENU button to exit.

Control by Universal DMX Controller

5.1 DMX512 ConnectionsACME Flandina 12 12pcs 8W CW LED Light Sources -
fig4

  1. At last unit, the DMX cable has to be terminated with a terminator. Solder a 120-o h m 1/4 W resistor between pin 2(DMX-) and pin 3(DMX+) into a 3-pin XLR-plug and plug it in the DMX-output of the last unit.
  2. Connect the unit together in a “daisy chain” by XLR plug cable from the output of the unit to the input of the next unit. The cable can only be used in series and cannot be connected in parallel. DMX 512 is a very high-speed signal. Inadequate or damaged cables, soldered joints or corroded connectors can easily distort the signal and shut down the system.
  3. The DMX output and input connectors are pass-through to maintain the DMX circuit, when one of the units’ power is disconnected.
  4. Each lighting unit needs to have a DMX address to receive the data by the controller. The address number is between 1-512.
  5. The end of the DMX 512 system should be terminated to reduce signal errors.
  6. 3 pin XLR connectors are more popular than 5 pins XLR.
    3 pin XLR: Pin 1: GND, Pin 2: Negative signal (-), Pin 3: Positive signal (+)
    5 pin XLR: Pin 1: GND, Pin 2: Negative signal (-), Pin 3: Positive signal (+), Pin4, Pin5 not used.

5.2 Address Setting
If you use a universal DMX controller to control the units, you have to set DMX address from 1 to 512 so that the units can receive DMX signal.
Press the MENU button to enter menu mode, select DMX Setting, press the ENTER button to confirm, use the UP/DOWN button to select DMX Address, press the ENTER button to confirm, the present address will blink in the display, use the UP/DOWN button to adjust the address from 001 to 512, press the ENTER button to store. Press the MENU button back to the last menu or let the unit idle 30 seconds to exit menu mode.
Please refer to the following diagram to address your DMX512 channel for the first 4 units.

Channel Mode| Unit 1
Address| Unit 2
Address| Unit 3
Address| Unit 4
Address
---|---|---|---|---
16 Channel| 1| 17| 33| 49
14 Channel| 1| 15| 29| 43
5 Channel| 1| 6| 11| 16

Please control the fixture by referring to the configurations below
Attentions:

  1. The unit will maintain the last condition until reset if you cut-off the DMX signal.
  2. For the channel Function, keep the value for about 3 seconds, then the corresponding function will take into effect.

16 Channels Mode:

CHANNEL VALUE FUNCTION
1 ****

000-255

| WHITE1

0%⭢100%

2| ****

000-255

| WHITE2

0%⭢100%

3| ****

000-255

| WHITE3

0%⭢100%

4| ****

000-255

| WHITE4

0%⭢100%

5| ****

000-255

| WHITE5

0%⭢100%

6| ****

000-255

| WHITE6

0%⭢100%

7| ****

000-255

| WHITE7

0%⭢100%

8| ****

000-255

| WHITE8

0%⭢100%

9| ****

000-255

| WHITE9

0%⭢100%

10|  | WHITE10
 | 000-255| 0%⭢100%
---|---|---
11| ****

000-255

| WHITE11

0%⭢100%

12| ****

000-255

| WHITE12

0%⭢100%






13

| ****

000-007

008-015

016-131

132-139

140-181

182-189

190-231

232-239

240-247

248-255

| STROBE

Close Open

Strobe from Slow to Fast Open

Slow Open Fast Close Open

Fast Open Slow Close Open

Random Strobe

Open

14| ****

000-255

| DIMMER

0%⭢100%

15| 000-255| DIMMER FINE







16

| ****

000-029

030-039

040-049

050-059

060-069

070-099

100-109

110-119

120-179

180-189

190-199

200-255

| FUNCTION Null Dimmer Curve: Linear Dimmer Curve: Square Law Dimmer Curve: Inv SQ Law Dimmer Curve: S Curve Null Led Frequency Setting Enable Led Frequency Setting Disable Null Dimmer Speed: Fast Dimmer Speed: Smooth Null
 |  |

14 Channels Mode:

CHANNEL VALUE FUNCTION
1 ****

000-255

| WHITE1

0%⭢100%

2| ****

000-255

| WHITE2

0%⭢100%

3| ****

000-255

| WHITE3

0%⭢100%

4| ****

000-255

| WHITE4

0%⭢100%

5| ****

000-255

| WHITE5

0%⭢100%

6| ****

000-255

| WHITE6

0%⭢100%

7| ****

000-255

| WHITE7

0%⭢100%

8| ****

000-255

| WHITE8

0%⭢100%

9| ****

000-255

| WHITE9

0%⭢100%

10| ****

000-255

| WHITE10

0%⭢100%

11| ****

000-255

| WHITE11

0%⭢100%

12| ****

000-255

| WHITE12

0%⭢100%

13| ****

000-255

| DIMMER

0%⭢100%

14| 000-255| DIMMER FINE
 |  |

Channels Mode:

CHANNEL VALUE FUNCTION
1

000-255

| WHITE1

0%⭢100%

2| 000-255| WHITE FINE

3

|

000-007

008-015

016-131

132-139

140-181

182-189

190-231

232-239

240-247

248-255

| STROBE

Close Open

Strobe from Slow to Fast Open

Slow Open Fast Close Open

Fast Open Slow Close Open

Random Strobe

Open

4|

000-255

| DIMMER

0%⭢100%

5| 000-255| DIMMER FINE
 |  |

Error Information

Error codes are shown continuously in the display when the fixture fails and they will not disappear until the fixture is repaired.

  1. LED Tem. Error
    Check whether the temperature detecting board is normal.
    Check whether the components of the temperature detecting board are damaged.
    Check whether the lead on the temperature detecting board is installed in place or disconnected.

  2. LED Too Hot Off
    When the fixture temperature reaches 83 ℃, it will automatically turn off to protect the fixture.

  3. LED Timeout Use

Troubleshooting

Following are a few common problems that may occur during operation. Here are some suggestions for troubleshooting:
A. The unit does not work and no light

  1. Check the connected power.
  2. Measure the voltage.
  3. Check the power indicator to see whether it can be lit up or not.

B. Not responding to the DMX controller

  1. Check whether the DMX connectors and the DMX cables are connected correctly.
  2. Check whether the DMX address is correctly set.
  3. If the intermittent DMX signal problem occurs, check whether the XLR socket and the signal cable are well connected.
  4. Try it with another DMX controller.
  5. Check whether the DMX cables run near or alongside to the high-voltage cables, which may damage or interfere with the signal circuit.

C. One of the channels is not working well

  1. The stepper motor might be damaged or the cable connected to the PCB might be broken.
  2. The motor’s drive IC on the PCB might be out of condition.

Fixture Cleaning

It is absolutely essential that the fixture is kept clean to ensure the maximum light-output and allow the fixture to function reliably throughout its life. The fixture must be cleaned regularly to avoid dust, dirt and smoke- fluid residues building up on or within the fixture. The cleaning frequency depends on the application environment. Clean the fixture immediately if the dust enters it to avoid damage to the optical lens due to excessive dust.

  • A soft lint-free cloth moistened with any good glass cleaning fluid is recommended, under no circumstances should solvents be used.
  • Always dry the parts carefully.
  • Clean the external optical lens at least every 20 days.

Innovation, Quality, Performance

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals