ACME Flandina 12 12pcs 8W CW LED Light Sources User Manual
- June 9, 2024
- acme
Table of Contents
User Manual
Please rede the instruction carefully before use
Safety Instructions
Please read the instruction carefully which includes important information
about the installation, usage and maintenance.
WARNING
Please keep this User Guide for future consultation. If you sell the unit to
another user, be sure that they also receive this instruction manual.
Important:
Damages caused by the disregard of this user manual are not subject to
warranty. The dealer will not accept liability for any resulting defects or
problems.
- Unpack and check carefully to ensure that there is no transportation damage before using the unit.
- This product is for indoor use only. Use only in a dry location.
- DO install and operate by qualified operator.
- DO NOT allow children to operate the fixture.
- Use safety chain when fixing the unit. Handle the unit by carrying its base instead of head only.
- The unit must be installed in a location with adequate ventilation, at least 50cm from adjacent surfaces.
- Be sure that no ventilation slots is blocked, otherwise the unit will be overheated.
- Before operation, ensure that you are connecting this product to the proper voltage in accordance with the specifications in this manual or on the product’s specification label.
- It’s important to ground the yellow/green conductor to earth in order to avoid electric shock.
- Minimum ambient temperature TA: 0 ℃. Maximum ambient temperature TA: 40℃. Do not operate this product at a lower or higher temperature.
- DO NOT connect the device to any dimmer pack.
- Keep flammable materials away from the fixture while operating to avoid fire hazard.
- Make sure the power cord is not crimped or damaged; replace it immediately if damaged.
- Unit’s surface temperature may reach up to 65℃. DO NOT touch the housing bare-handed during its operation.
- Avoid any flammable liquids, water or metal from entering the unit. Once it happens, cut off the mains power immediately.
- DO NOT operate in a dirty or dusty environment. DO clean the fixture regularly.
- DO NOT touch any wire during operation as there might be a hazard of electric shock.
- Avoid entanglement of the power cord with other wires.
- The minimum distance to objects/surface must be more than 0.5 meters.
- In the event of serious operating problem, stop using the unit immediately.
- Never turn on and off the unit time after time.
- The housing, the lenses, or the ultraviolet filter must be replaced if they are visibly damaged.
- DO NOT open the housing as there are no user serviceable parts inside.
- DO NOT attempt to operate this unit if it becomes damaged. DO NOT attempt any repairs yourself. Repairs carried out by unskilled people can lead to damage or malfunction. Please contact the nearest authorized technical assistance center if needed.
- Disconnect this product from its power source before servicing.
- DO use the original packaging if the device is to be transported.
- Avoid direct eye exposure to the light source while the product is on.
- DO NOT operate this product if you see damage on the housing, shields, or cables. Have the damaged parts replaced by an authorized technician at once.
Installation:
The fixture should be fixed on the clamp. Always ensure that the unit is
firmly fixed to avoid vibration and slipping off during operation. Ensure that
the trussing or area of installation must be able to hold 10 times the weight
without any deformation. Always install a safety cable that can hold at least
12 times the weight of the fixture when installing. DO install and operate by
qualified operator. It must be installed in a place where there is out of the
reach of people.
Technical Specifications
Power Voltage: 100-240V~ 50/60Hz
Power Consumption: 55W
Light Source: 12x3W WW LED
Beam Angle: 4°
Dimming/Strobe: Smooth dimming from 0-100%; outstanding strobe effect with
variable speed
Control: DMX Channel: 1 6/14/5 Channels
Control Mode: DMX512, RDM, Primary/Secondary Firmware Upgrade via DMX link
Construction: Display: OLED display
Data In/Out: 3-pin XLR (5-pin XLR is optional)
Power In/Out: Power Connector in/out
Protection Rating: IP20
Features: 12 pcs LED pixel control
High efficiency LED lens, 2700K golden yellow light, beam angle up to 4°
Suitable for project installation and touring performances
Double mounting brackets design and the adjustable angle reaches 180 degrees
in both direction
Dimension/ Weight: 998x102x106mm, 3.4kgs 39.3″x4″x4.2″in, 7.5lbs
Photometric Diagram:
Control Panel
-
DISPLAY: To show the various menus and the selected functions
-
Button:
MENU| To select the programming functions
---|---
DOWN| To go forward in the selected functions
UP| To go backward in the selected functions
ENTER| To confirm the selected functions -
DMX IN:
For DMX512 operation, use 3-pin XLR cable to link the unit and controller (5-pin XLR is optional) -
DMX OUT:
For DMX512 operation, use 3-pin XLR cable to link the next units (5-pin XLR is optional) -
POWERCON IN: To connect to supply power
-
POWERCON OUT: To connect to the next unit
How to Set the Unit
4.1 Main Function
Turn on the unit, press the MENU button into menu mode, and press the UP/DOWN
button until the required function is shown on the monitor. Select the
function by pressing the ENTER button.
Use the UP/DOWN button to choose the submenu, press the ENTER button to store
and automatically return to the last menu. Press the MENU button or let the
unit idle 30 seconds to exit menu mode.
The main functions are shown below:
DMX Settings
To select DMX Settings, press the ENTER button to confirm, use the UP/DOWN
button to select DMX Address, Channel Mode, No DMX Status or View DMX Value.
DMX Address
To select DMX Address, press the ENTER button to confirm. Use the UP/DOWN
button to adjust the address from 001 to 497/499/508, press the ENTER button
to store. Press the MENU button back to the last menu or let the unit idle 30
seconds to exit menu mode.
Channel Mode
To select Channel Mode, press the ENTER button to confirm. Use the UP/DOWN
button to select Mode1(16), Mode2(14) or Mode3(5), press the ENTER button to
store. Press the MENU button back to the last menu or let the unit idle 30
seconds to exit menu mode.
No DMX Status
To select No DMX Status, press the ENTER button to confirm. Use the UP/DOWN
button to select Hold(fixture continues to obey the last command it received
Via DMX if DMX signal stops), Blackout(fixture blacks out if DMX signal stops)
or Manual(the fixture will automatically read the DMX value in the “Manual
Test” menu for operation after selecting this mode), press the ENTER button to
store. Press the MENU button back to the last menu or let the unit idle 30
seconds to exit menu mode.
View DMX Value
To select View DMX Value, press the ENTER button to confirm. Use the UP/DOWN
button to view the DMX channel value. Press the MENU button back to the last
menu or let the unit idle 30 seconds to exit menu mode.
Fixture Settings
To select Fixture Settings, press the ENTER button to confirm, use the UP/DOWN
button to select Dimmer Curve, Dimmer Speed or Invert Pixel Order.
Dimmer Curve
To select Dimmer Curve, press the ENTER button to confirm. Use the DOWN/UP
button to select Linear, Square Law, Inv SQ Law or S Curve, press the ENTER
button to store. Press the MENU button back to the last menu or let the unit
idle 30 seconds to exit menu mode.
Dimmer Modes
Optically Linear: The increase in light intensity appears to be linear as DMX
value is increased.
Square Law: Light intensity control is finer at low levels and coarser at high
levels.
Inverse Square Law: Light intensity control is coarser at low levels and
finger at high levels.
S-Curve: Light intensity control is finger at low levels and high levels and
coarser at medium levels.
Dimmer Speed
To select Dimmer Speed, press the ENTER button to confirm. Use the UP/DOWN
button to select Fast or Smooth, press the ENTER button to store. Press the
MENU button back to the last menu or let the unit idle 30 seconds to exit menu
mode.
Invert Pixel Order
To select Invert Pixel Order, press the ENTER button to confirm. Use the
UP/DOWN button to select No or Yes, press the ENTER button to store. Press the
MENU button back to the last menu or let the unit idle 30 seconds to exit menu
mode.
Display Settings
To select Display Settings, press the ENTER button to confirm, use the UP/DOWN
button to select Display Invert, Temperature Unit or Language.
Display Invert
Select Display Invert, press the ENTER button to confirm, present mode will
blink on the display, use the UP/DOWN button to select No (normal display) or
Yes (invert display), press the ENTER button to store. Press the MENU button
back to the last menu or let the unit idle 30 seconds to exit menu mode.
Temperature Unit
Select Temperature Unit, press the ENTER button to confirm. Use the UP/DOWN
button to select ℃ or ℉, press the ENTER button to store. Press the MENU
button back to the last menu or let the unit idle 30 seconds to exit menu
mode.
Language
Select Language, press the ENTER button to confirm, present mode will blink on
the display, use the UP/DOWN button to select English or Chinese. Press the
MENU button back to the last menu or let the unit idle 30 seconds to exit menu
mode.
Auto Test
To select Auto Test, press the ENTER button to confirm, the unit will run
built-in programs to automatically test its functions. Press the MENU button
back to the last menu or exit menu mode after auto test.
Manual Test
To select Manual Test, press the ENTER button to confirm, use the UP/DOWN
button to select Mode, Clear, White1……White12, Strobe or White, Shutter
Dimmer, press the ENTER button to confirm, use the UP/DOWN button to adjust
the value from 0 to 255, press the ENTER button to store. Press the MENU
button back to the last menu or let the unit idle 30 seconds to exit menu
mode.
(The fixture will return to the previous DMX state after exiting Manual Mode
menu and the Manual Test parameters will be automatically saved after power
off and restart.)
Information
To select Information, press the ENTER button to confirm, use the UP/DOWN
button to select Fixture Use Hour, LED Use Hour, Temperatue, Firmware Version,
RDM UID or Error Logs.
Fixture Use Hour
Select Fixture Use Hour, press the ENTER button to confirm, fixture use hour
will show on the display, press the MENU button to exit.
LED Use Hour
To select LED Use Hour, press the ENTER button to confirm, use the UP/DOWN
button to select Total LED Hour, LED On Hour or LED Hours Reset, press the
ENTER button to store. To select LED Hours Reset, press the ENTER button to
confirm. Use the UP/DOWN button to select No or Yes, press the ENTER button to
confirm. To select Yes, press the ENTER button to confirm, use the UP/DOWN
button to set the password 050 to reset the LED hours, press the ENTER button
to store. Press the MENU button back to the last menu or exit menu mode let
the unit idle 30 seconds.
Temperature
Select Temperature, press the ENTER button to confirm, use the UP/DOWN button
to select LED or PCBA, press the ENTER button to confirm, fixture’s current
temperature and max temperature of the LED or PCBA will show on the display,
press the MENU button to exit.
Firmware Version
Select Firmware Version, press the ENTER button to confirm, firmware version
will show on the display, press the MENU button back to exit.
RDM UID
Select RDM UID, press the ENTER button to confirm, RDM UID will show on the
display, press the MENU button back to exit.
Error Logs
Select Error Logs, press the ENTER button to confirm. Use the UP/DOWN button
to select Fixture Errors or Reset Error Log, press the ENTER button to store.
Select Reset Error Log, press the ENTER button to confirm. Use the UP/DOWN
button to select No or Yes, press the ENTER button to store.
Select Yes, press the ENTER button to confirm. Use the UP/DOWN button to set
the password 050, press the ENTER button to store. Press the MENU button back
to the last menu or let the unit idle 30 seconds to exit menu mode.
Factory Restore
Select Factory Restore, press the ENTER button to confirm, use the UP/DOWN
button to select No (normal) or Yes (the fixture will reset to factory
settings), press ENTER button to store. Press the MENU button to exit.
RDM FUNCTIONS
Select the MANUFACTURER menu to display the manufacturer of the fixture.
Select the SOFTWARE VERSION menu and the program version number of the fixture
will be displayed.
Select the DMX START ADDRESS menu to change the DMX 512 address (001-512).
Select the DEVICE MODEL DESCRIPTION menu to display the model of the fixture.
Select the DEVICE LABEL menu to change the model of the fixture.
Select the DMX PERSONALITY menu to set the channel mode of the fixture (1 6/1
4/5 channel).
Select the DMX PERSONALITY DESCRIPTION menu to display the current channel
mode of the fixture.
Select the DEVICE HOURS menu to display the running time of the fixture.
Select the RESET DEVICE menu, the WARM RESET/COLD RESET option will be
displayed. When WARM RESET is selected, the fixture will start a warm reset,
and exit when COLD RESET is selected.
4.2 Home Position Adjustment
Press the MENU button into menu mode, then press the ENTER button for about 3
seconds into offset mode to adjust the home position. Select the function by
pressing the ENTER button. Use the UP/DOWN button to choose the submenu, press
the ENTER button to store and automatically return to the last menu. Press
MENU button to exit.
Frequency(Hz)
Enter offset mode, Select Frequency(Hz), press the ENTER button to confirm,
the present position will blink on the display, use the UP/DOWN button to
offset the value from 1072 to 1327, press the ENTER button to store. Press the
MENU button to exit.
White1
Enter offset mode, select White1, press the ENTER button to confirm, the
present position will blink on the display, use the UP/DOWN button to offset
the value from 0 to 255, press the ENTER button to store. Press the MENU
button to exit. ……
White12
Enter offset mode, select White12, press the ENTER button to confirm, the
present position will blink on the display, use the UP/DOWN button to offset
the value from 0 to 255, press the ENTER button to store. Press the MENU
button to exit.
Control by Universal DMX Controller
5.1 DMX512 Connections
- At last unit, the DMX cable has to be terminated with a terminator. Solder a 120-o h m 1/4 W resistor between pin 2(DMX-) and pin 3(DMX+) into a 3-pin XLR-plug and plug it in the DMX-output of the last unit.
- Connect the unit together in a “daisy chain” by XLR plug cable from the output of the unit to the input of the next unit. The cable can only be used in series and cannot be connected in parallel. DMX 512 is a very high-speed signal. Inadequate or damaged cables, soldered joints or corroded connectors can easily distort the signal and shut down the system.
- The DMX output and input connectors are pass-through to maintain the DMX circuit, when one of the units’ power is disconnected.
- Each lighting unit needs to have a DMX address to receive the data by the controller. The address number is between 1-512.
- The end of the DMX 512 system should be terminated to reduce signal errors.
- 3 pin XLR connectors are more popular than 5 pins XLR.
3 pin XLR: Pin 1: GND, Pin 2: Negative signal (-), Pin 3: Positive signal (+)
5 pin XLR: Pin 1: GND, Pin 2: Negative signal (-), Pin 3: Positive signal (+), Pin4, Pin5 not used.
5.2 Address Setting
If you use a universal DMX controller to control the units, you have to set
DMX address from 1 to 512 so that the units can receive DMX signal.
Press the MENU button to enter menu mode, select DMX Setting, press the ENTER
button to confirm, use the UP/DOWN button to select DMX Address, press the
ENTER button to confirm, the present address will blink in the display, use
the UP/DOWN button to adjust the address from 001 to 512, press the ENTER
button to store. Press the MENU button back to the last menu or let the unit
idle 30 seconds to exit menu mode.
Please refer to the following diagram to address your DMX512 channel for the
first 4 units.
Channel Mode| Unit 1
Address| Unit 2
Address| Unit 3
Address| Unit 4
Address
---|---|---|---|---
16 Channel| 1| 17| 33| 49
14 Channel| 1| 15| 29| 43
5 Channel| 1| 6| 11| 16
Please control the fixture by referring to the configurations below
Attentions:
- The unit will maintain the last condition until reset if you cut-off the DMX signal.
- For the channel Function, keep the value for about 3 seconds, then the corresponding function will take into effect.
16 Channels Mode:
CHANNEL | VALUE | FUNCTION |
---|---|---|
1 | **** |
000-255
| WHITE1
0%⭢100%
2| ****
000-255
| WHITE2
0%⭢100%
3| ****
000-255
| WHITE3
0%⭢100%
4| ****
000-255
| WHITE4
0%⭢100%
5| ****
000-255
| WHITE5
0%⭢100%
6| ****
000-255
| WHITE6
0%⭢100%
7| ****
000-255
| WHITE7
0%⭢100%
8| ****
000-255
| WHITE8
0%⭢100%
9| ****
000-255
| WHITE9
0%⭢100%
10| | WHITE10
| 000-255| 0%⭢100%
---|---|---
11| ****
000-255
| WHITE11
0%⭢100%
12| ****
000-255
| WHITE12
0%⭢100%
13
| ****
000-007
008-015
016-131
132-139
140-181
182-189
190-231
232-239
240-247
248-255
| STROBE
Close Open
Strobe from Slow to Fast Open
Slow Open Fast Close Open
Fast Open Slow Close Open
Random Strobe
Open
14| ****
000-255
| DIMMER
0%⭢100%
15| 000-255| DIMMER FINE
16
| ****
000-029
030-039
040-049
050-059
060-069
070-099
100-109
110-119
120-179
180-189
190-199
200-255
| FUNCTION Null Dimmer Curve: Linear Dimmer Curve: Square Law Dimmer
Curve: Inv SQ Law Dimmer Curve: S Curve Null Led Frequency Setting Enable Led
Frequency Setting Disable Null Dimmer Speed: Fast Dimmer Speed: Smooth Null
| |
14 Channels Mode:
CHANNEL | VALUE | FUNCTION |
---|---|---|
1 | **** |
000-255
| WHITE1
0%⭢100%
2| ****
000-255
| WHITE2
0%⭢100%
3| ****
000-255
| WHITE3
0%⭢100%
4| ****
000-255
| WHITE4
0%⭢100%
5| ****
000-255
| WHITE5
0%⭢100%
6| ****
000-255
| WHITE6
0%⭢100%
7| ****
000-255
| WHITE7
0%⭢100%
8| ****
000-255
| WHITE8
0%⭢100%
9| ****
000-255
| WHITE9
0%⭢100%
10| ****
000-255
| WHITE10
0%⭢100%
11| ****
000-255
| WHITE11
0%⭢100%
12| ****
000-255
| WHITE12
0%⭢100%
13| ****
000-255
| DIMMER
0%⭢100%
14| 000-255| DIMMER FINE
| |
Channels Mode:
CHANNEL | VALUE | FUNCTION |
---|---|---|
1 |
000-255
| WHITE1
0%⭢100%
2| 000-255| WHITE FINE
3
|
000-007
008-015
016-131
132-139
140-181
182-189
190-231
232-239
240-247
248-255
| STROBE
Close Open
Strobe from Slow to Fast Open
Slow Open Fast Close Open
Fast Open Slow Close Open
Random Strobe
Open
4|
000-255
| DIMMER
0%⭢100%
5| 000-255| DIMMER FINE
| |
Error Information
Error codes are shown continuously in the display when the fixture fails and they will not disappear until the fixture is repaired.
-
LED Tem. Error
Check whether the temperature detecting board is normal.
Check whether the components of the temperature detecting board are damaged.
Check whether the lead on the temperature detecting board is installed in place or disconnected. -
LED Too Hot Off
When the fixture temperature reaches 83 ℃, it will automatically turn off to protect the fixture. -
LED Timeout Use
Troubleshooting
Following are a few common problems that may occur during operation. Here are
some suggestions for troubleshooting:
A. The unit does not work and no light
- Check the connected power.
- Measure the voltage.
- Check the power indicator to see whether it can be lit up or not.
B. Not responding to the DMX controller
- Check whether the DMX connectors and the DMX cables are connected correctly.
- Check whether the DMX address is correctly set.
- If the intermittent DMX signal problem occurs, check whether the XLR socket and the signal cable are well connected.
- Try it with another DMX controller.
- Check whether the DMX cables run near or alongside to the high-voltage cables, which may damage or interfere with the signal circuit.
C. One of the channels is not working well
- The stepper motor might be damaged or the cable connected to the PCB might be broken.
- The motor’s drive IC on the PCB might be out of condition.
Fixture Cleaning
It is absolutely essential that the fixture is kept clean to ensure the maximum light-output and allow the fixture to function reliably throughout its life. The fixture must be cleaned regularly to avoid dust, dirt and smoke- fluid residues building up on or within the fixture. The cleaning frequency depends on the application environment. Clean the fixture immediately if the dust enters it to avoid damage to the optical lens due to excessive dust.
- A soft lint-free cloth moistened with any good glass cleaning fluid is recommended, under no circumstances should solvents be used.
- Always dry the parts carefully.
- Clean the external optical lens at least every 20 days.
Innovation, Quality, Performance