Please read the instruction carefully before use
User Manual

Safety Instructions

Please read the instruction carefully which includes important information about the installation, usage and maintenance.

WARNING
Please keep this User Guide for future consultation. If you sell the unit to another user, be sure that they also receive this instruction manual.
Important:
Damages caused by the disregard of this user manual are not subject to warranty. The dealer will not accept liability for any resulting defects or problems.

  • Unpack and check carefully to ensure that there is no transportation damage before using the unit.

  • This product is for indoor use only. Use only in a dry location.

  • DO install and operate by qualified operator.

  • DO NOT allow children to operate the fixture.

  • Use safety chain when fixing the unit. Handle the unit by carrying its base instead of head only.

  • The unit must be installed in a location with adequate ventilation, at least 50cm from adjacent surfaces.

  • Be sure that no ventilation slots is blocked, otherwise the unit will be overheated.

  • Before operation, ensure that you are connecting this product to the proper voltage in accordance with the specifications in this manual or on the product’s specification label.

  • It’s important to ground the yellow/green conductor to earth in order to avoid electric shock.

  • Minimum ambient temperature TA: 0 ℃. Maximum ambient temperature TA: 40℃. Do not operate this product at a lower or higher temperature.

  • DO NOT connect the device to any dimmer pack.

  • Keep flammable materials away from the fixture while operating to avoid fire hazard.

  • Make sure the power cord is not crimped or damaged; replace it immediately if damaged.

  • Avoid any flammable liquids, water or metal from entering the unit. Once it happens, cut off
    the mains power immediately.

  • DO NOT operate in a dirty or dusty environment. DO clean the fixture regularly.

  • DO NOT touch any wire during operation as there might be a hazard of electric shock.

  •  Avoid entanglement of the power cord with other wires.

  • Disconnect mains power before fuse replacement or servicing.

  • Replace fuse only with the same type.

  • In the event of serious operating problem, stop using the unit immediately.

  • Never turn on and off the unit time after time.

  • The housing, the lenses, or the ultraviolet filter must be replaced if they are visibly damaged.

  • DO NOT open the housing as there are no user serviceable parts inside.

  • DO NOT attempt to operate this unit if it becomes damaged. DO NOT attempt any repairs yourself. Repairs carried out by unskilled people can lead to damage or malfunction. Please contact the nearest authorized technical assistance center if needed.

  • Disconnect this product from its power source before servicing.

  • DO use the original packaging if the device is to be transported.

  • Avoid direct eye exposure to the light source while the product is on.

  • DO NOT operate this product if you see damage on the housing, shields, or cables. Have the damaged parts replaced by an authorized technician at once.

Installation:
The fixture should be fixed on the clamp. Always ensure that the unit is firmly fixed to avoid vibration and slipping off during operation. Ensure that the trussing or area of installation must be able to hold 10 times the weight without any deformation. Always install a safety cable that can hold at least 12 times the weight of the fixture when installing.
DO install and operate by qualified operator. It must be installed in a place where there is out of the reach of people.

Technical Specifications

Power Voltage: AC 100~240V, 50/6 0 Hz
Power Consumption: 100W
Light Source: 240pcs 0.5W CW LED (CW)
240pcs 0.5W WW LED (WW)
Color Temperature: 5600±250K (CW)
3200±150K (WW)
Beam Angle: 110°
Optical:
CRI: CW≥94, WW≥95
CQS: CW≥94, WW≥94
TLCI: CW≥95, WW≥95
Control:
DMX Channel: 1/2A/2B/3 Channels
Control Mode: DMX512, RDM, Primary/Secondary, Art-Net
Firmware Upgrade: Update via DMX link
Construction:
Display: LCD display
Data In/Out: 5-pin XLR (3-pin XLR is optional)
Power In/Out: Power Connector in
Protection Rating: IP20
Features:
With outstanding floodlight and soft light, TV LIGHT PANEL 1000 are widely applied to photographic studio, TV station, conference room, shopping mall; Access to buttery.

Dimension/Weight:
673x144x306mm, 9.2kgs
26.5″x5.7″x12″in, 20.3lbs

Photometric Diagram:

Control Panel

  1. Display: To show the various menus and the selected function
  2. Button:
    MENU| To enter into move backward or leave the menu
    ---|---
    UP| To go backward to move up in the menu
    DOWN| To go forward to move down in the menu
    ENTER| To perform the desired functions
  3. DIMMER: Adjust the dimmer
  4. POWER IN: To connect to supply power
  5. FUSE(T 2A): Protects the unit from over-voltage or short circuit
  6. BATTERY (DC 48V): Connects to external battery
  7. DMX OUT: Use 5-pin XLR cable to link the next units (3-pin XLR is optional)
  8. DMX IN: Use 5-pin XLR cable to link the unit and DMX controller (3-pin XLR is optional)
  9. ETHERNET: Transfers fixture’s information to a main controller

The Plate for Barn Door Installation

At first, please push the barn door by hand.

Secondly, please put the Barn Door into the unit, to fasten the screws of the slot, then finish the barn door installation.

How To Set The Unit

5.1 Main Function
Turn on the unit, press the MENU button into menu mode, and press the UP/DOWN button until the required function is shown on the monitor. Select the function by pressing the ENTER button.
Use the UP/DOWN button to choose the submenu, press the ENTER button to store and automatically return to the last menu. Press the MENU button or let the unit idle 30 seconds to exit menu mode.
The main functions are shown below:

DMX Setting
To select DMX Setting, press the ENTER button to confirm, use the UP/DOWN button to select DMX Address, Art-Net Setup or Channel Mode.
DMX Address
To select DMX Address, press the ENTER button to confirm. Use the UP/DOWN button to adjust the address from 001 to 512, press the ENTER button to store. Press the MENU button back to the last menu or let the unit idle 30 seconds to exit menu mode.
Art-Net Setup
To select Art-Net Setup, press the ENTER button to confirm. Use the UP/DOWN button to select Ethernet IP Setup or Art-Net Port Setup, press the ENTER button to store. Press the MENU button back to the last menu or let the unit idle 30 seconds to exit menu mode.
Channel Mode
To select Channel Mode, press the ENTER button to confirm. Use the UP/DOWN button to select 1 CH, 2A CH, 2B CH or 3 CH, press the ENTER button to store. Press the MENU button back to the last menu or let the unit idle 30 seconds to exit menu mode.
Dimmer Speed
To select Dimmer Speed, press the ENTER button to confirm. Use the UP/DOWN button to select Smooth or Fast, press the ENTER button to store. Press the MENU button back to the last menu or let the unit idle 30 seconds to exit menu mode.
Dimmer Curve Setting
To select Dimmer Curve Setting, press the ENTER button to confirm. Use the UP/DOWN button to select Linear Curve, Sq. Law Curve, Invert Sq. Law Curve or S Curve, press the ENTER button to store. Press the MENU button back to the last menu or let the unit idle 30 seconds to exit menu mode.

Optically Linear: The increase in light intensity appears to be linear as DMX value is increased.
Square Law: Light intensity control is finer at low levels and coarser at high levels.
Inverse Square Law: Light intensity control is coarser at low levels and finger at high levels.
S-Curve: Light intensity control is finger at low levels and high levels and coarser at medium levels.

Pri./Sec. Mode
To select Pri./Sec. Mode, press the ENTER button to confirm. Use the UP/DOWN button to select Primary or Secondary, press the ENTER button to store. Press the MENU button back to the last menu or let the unit idle 30 seconds to exit menu mode.
DMX Last State
To select DMX Last State, press the ENTER button to confirm. Use the UP/DOWN button to select Pri.Sec., Blackout or Hold, press the ENTER button to store. Press the MENU button back to the last menu or let the unit idle 30 seconds to exit menu mode.
Frequency
To select Frequency, press the ENTER button to confirm. Use the UP/DOWN button to select 900hz, 1000hz, 1100hz, 1200hz, 1300hz, 1400hz, 1500hz, 2500hz, 4000hz, 5000hz, 10000hz, 15000hz, 20000hz or 25000hz, press the ENTER button to store. Press the MENU button back to the last menu or let the unit idle 30 seconds to exit menu mode.
Display Setting
To select Display Setting, press the ENTER button to confirm, use the UP/DOWN button to select Contrast Ratio, Backlight Auto Off, Invert Display or Language.
Contrast Ratio
Select Contrast Ratio, press the ENTER button to confirm, present mode will blink on the display, use the UP/DOWN button to adjust the contrast ratio from 1 to 30, press the ENTER button to store.
Press the MENU button back to the last menu or let the unit idle 30 seconds to exit menu mode.
Backlight Auto Off
Select Backlight Auto Off, press the ENTER button to confirm, present mode will blink on the display, use the UP/DOWN button to select No or Yes, press the ENTER button to store. Press the MENU button back to the last menu or let the unit idle 30 seconds to exit menu mode.
Invert Display
Select Invert Display, press the ENTER button to confirm, present mode will blink on the display, use the UP/DOWN button to select No (normal display) or Yes (invert display), press the ENTER button to store. Press the MENU button back to the last menu or let the unit idle 30 seconds to exit menu mode.
Language
Select Language, press the ENTER button to confirm, present mode will blink on the display, use the UP/DOWN button to select English or Chinese, press the ENTER button to store. Press the MENU button back to the last menu or let the unit idle 30 seconds to exit menu mode.
Manual Mode
To select Manual Mode, press the ENTER button to confirm. Use the UP/DOWN button to select Dimmer, press the ENTER button to store. Use the UP/DOWN button to adjust the value from 0 to 255, press the ENTER button to store. Press the MENU button back to the last menu or let the unit idle 30 seconds to exit menu mode.
Fixture Information
To select Fixture Information, press the ENTER button to confirm, use the UP/DOWN button to select Fixture Time or Firmware Version.
Fixture Time
Select Fixture Time, press the ENTER button to confirm, fixture use time will show on the display, press the MENU button to exit.
Firmware Version
Select Firmware Version, press the ENTER button to confirm, firmware version will show on the display, press the MENU button back to exit.
Factory Setting
Select Factory Setting, press the ENTER button to confirm, use the UP/DOWN button to select No(normal) or Yes(the fixture will reset to factory settings), press ENTER button to store. Press the MENU button to exit.

RDM FUNCTIONS
Select the MANUFACTURER menu to display the manufacturer of the fixture.
Select the SOFTWARE VERSION menu and the program version number of the fixture will be displayed.
Select the DMX START ADDRESS menu to change the DMX 512 address (001-512).
Select the DEVICE MODEL DESCRIPTION menu to display the model of the fixture.
Select the DEVICE LABEL menu to change the model of the fixture.
Select the DMX PERSONALITY menu to set the channel mode of the fixture (1/2 A /2 B /3 channel).
Select the DMX PERSONALITY DESCRIPTION menu to display the current channel mode of the fixture.
Select the DEVICE HOURS menu to display the running time of the fixture.
Select the RESET DEVICE menu, the WARM RESET/COLD RESET option will be displayed. When WARM RESET is selected, the fixture will start a warm reset, and exit when COLD RESET is selected.

Control By Universal DMX Controller

6.1 DMX512 Connection

  1. At last unit, the DMX cable has to be terminated with a terminator. Solder a 120-o h m 1/4 W resistor between pin 2(DMX-) and pin 3(DMX+) into a 3-pin XLR-plug and plug it in the DMX-output of the last unit.
  2. Connect the unit together in a “daisy chain” by XLR plug cable from the output of the unit to the input of the next unit. The cable cannot be branched or split to a “Y” cable. DMX 512 is a very high-speed signal. Inadequate or damaged cables, soldered joints or corroded connectors can easily distort the signal and shut down the system.
  3. The DMX output and input connectors are pass-through to maintain the DMX circuit, when one of the units’ power is disconnected.
  4. Each lighting unit needs to have a DMX address to receive the data by the controller. The address number is between 1-512.
  5. The end of the DMX 512 system should be terminated to reduce signal errors.
  6. 3 pin XLR connectors are more popular than 5 pins XLR.
    3 pin XLR: Pin 1: GND, Pin 2: Negative signal (-), Pin 3: Positive signal (+)
    5 pin XLR: Pin 1: GND, Pin 2: Negative signal (-), Pin 3: Positive signal (+), Pin4, Pin5 not used.

6.2 Address Setting
If you use a universal DMX controller to control the units, you have to set DMX address from 1 to 512 so that the units can receive DMX signal.
Press the MENU button to enter menu mode, select DMX Setting, press the ENTER button to confirm, use the UP/DOWN button to select DMX Address, press the ENTER button to confirm, the present address will blink in the display, use the UP/DOWN button to adjust the address from 001 to 512, press the ENTER button to store. Press the MENU button back to the last menu or let the unit idle 30 seconds to exit menu mode.
Please refer to the following diagram to address your DMX512 channel for the first 4 units.

Channel mode| Unit 1
Address| Unit 2
Address| Unit 3
Address| Unit 4
Address
---|---|---|---|---
1 channels| 1| 2| 3| 4
2A channels| 1| 3| 5| 7
2B channels| 1| 3| 5| 7
3 channels| 1| 4| 7| 10

6.3 DMX512 Configuration
Please control the fixture by referring to the configurations below

Attentions:

  1. The unit will maintain the last condition until reset if you cut-off the DMX signal.
  2. For the channel Function, keep the value for about 3 seconds, then the corresponding function will take into effect.

1 Channels (Mode 1):

CHANNEL VALUE FUNCTION
1 000-255 DIMMER

0%→100%

2A Channels (Mode 2):

CHANNEL VALUE FUNCTION
1 000-255 DIMMER

0→100%
2| 000-031
032-063
064-095
096-127
128-159
160-191
192-223
224-255| STROBE
Off
On
Strobe: Slow to Fast
On
Strobe Pulse: Fast to Slow
On
Random Strobe
On

2B Channels (Mode 3):

CHANNEL VALUE FUNCTION
1 000-255 DIMMER

0%→100%
2| 000-255| DIMMER FINE

3 Channels (Mode 4):

CHANNEL VALUE FUNCTION
1 000-255 DIMMER

0%→100%
2| 000-255| DIMMER FINE
3| 000-031
032-063
064-095
096-127
128-159
160-191
192-223
224-255| STROBE
Off
On
Strobe: Slow to Fast
On
Strobe Pulse: Fast to Slow
On
Random Strobe
On

Troubleshooting

Following are a few common problems that may occur during operation. Here are some suggestions for troubleshooting:

A. The unit does not work, no light and the fan does not work

  1. Check the connected power.
  2. Measure the voltage.
  3. Check the power indicator to see whether it can be lit up or not.

B. Not responding to the DMX controller

  1. Check whether the DMX connectors and the DMX cables are connected correctly.
  2. Check whether the DMX address is correctly set.
  3. If the intermittent DMX signal problem occurs, check whether the XLR socket and the signal cable are well connected.
  4. Try it with another DMX controller.
  5. Check whether the DMX cables run near or alongside to the high-voltage cables, which may damage or interfere with the signal circuit.

C. One of the channels is not working well

  1. The stepper motor might be damaged or the cable connected to the PCB might be broken.
  2. The motor’s drive IC on the PCB might be out of condition.

Fixture Cleaning

It is absolutely essential that the fixture is kept clean to ensure the maximum light-output and allow the fixture to function reliably throughout its life. The fixture must be cleaned regularly to avoid dust, dirt and smoke- fluid residues building up on or within the fixture. The cleaning frequency depends on the application environment. Clean the fixture immediately if the dust enters it to avoid damage to the optical lens due to excessive dust.

  • A soft lint-free cloth moistened with any good glass cleaning fluid is recommended, under no circumstances should solvents be used.
  • Always dry the parts carefully.
  • Clean the external optical lens at least every 20 days.

Declaration of Conformity
We declare that our products (lighting equipments) comply with the following specification and bears CE mark in accordance with the provision of the Electromagnetic Compatibility (EMC) Directive 2014/3 0/EU.
EN 55032: 2015; EN 55103-2: 2009;
EN 61000-3-2: 2014; EN 61000-3-3: 2013.
&
Harmonized Standard
EN 60598-2-17: 1989+A2: 1991; EN 60598-1: 2015; EN 62471: 2008;
EN 62493: 2015; EN 62031: 2008+A1: 2013+A2: 2015.
Safety of household and similar electrical appliances
Part 1: General requirements
Innovation, Quality, Performance

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals