LENA LIGHTING V-C Sterilon Air Light Z4 (288W/Z4) (576W/ Z4) User Manual

June 9, 2024
LENA LIGHTING

LENA LIGHTING logo V-C Sterilon Air Light Z4 (288W/Z4) (576W/ Z4)
User ManualLENA LIGHTING V-C Sterilon Air Light
Z4 USER MANUAL

V-C Sterilon Air Light Z4 (288W/Z4) (576W/ Z4)

Version with power cord

**** IMPORTANT INSTRUCTIONS FOR SAFE USE

WARNING BEFORE USING UV-C STERILON AIR LIGHT FOR
THE FIRST TIME, READ THE USER MANUAL AND
FOLLOW THE INSTRUCTIONS.
FLOW DISINFECTION
UVC AIR LIGHT luminaires use ultraviolet light, destroy the DNA or RNA of all microorganisms that will be exposed and remove viruses, bacteria and fungi from the air. Covered UVC light does not reach the outside of the lamp. Thanks to stimulated circulation, the air passes through luminaire interior, where it is exposed to the light and cleaned, and then pushed outside. UV-C STERILON AIR LIGHT luminaires may work in the presence of people.
Exposure method:

  1. Place the lamp in a disinfected room, if possible in a central place, to increase the eectiveness of disinfection. Remember that the disinfection ein a given place decreases as the distance from the lamp increases.

  2. Do not cover the luminaire fan, do not place any objects on the luminaire. In order not to disturb circulation, leave an empty space and do not put any objects within 1m of the luminaire fan.

  3. There may be people in the room. They can move freely and do not need protective clothing.

  4. Do not open the luminaire covers during its operation.
    Secure the luminaire against uncontrolled opening by other people.

  5. Do not use in rooms smaller than 1 m

  6. The smell emitted by the UV-C STERILON AIR LIGHT is a technical fragrance. It can last for approximately ⁶⁰ hours of device use. This smell does not pose a threat
    to the users of the device.

  7. A small amount of visible blue light – which is a reflected light, does not contain UV-C radiation and is safe for humans.

Disinfection efficiency

  • The AIR LIGHT is 4×110 m³/h (288W / Z4), 4×200 m³/h (576W / Z4).
  • The maximum volume (cubature) of the disinfected room: 150m² (440 m³) (288W / Z4), 250m² (800 m³) (576W / Z4).

Filter replacement
Sterilon AIR / AIR LIGHT UVC luminaires are standard equipped with PPI30 filters.
This filter should be checked after the first 4 months of the device operation. In case of dirt that could block the air flow (e.g. when the device is operated in dusty rooms), the filter should be replaced after every 4 months of operation. If the filter is not dirty during the first inspection, its cleanliness should be checked after every 6 months (or 1000 hours) of operation of the device and replaced if dirt appears.
Operational safety
The UV-C light emitted by the lamp is highly harmful to humans and other living organisms, damages eyesight, skin and cell DNA. UV-C light degrades the DNA and RNA code in the cells of living organisms. Damage to the luminaire will not aect your health while maintaining basic precautions. If the fluorescent lamps break, ventilate the room for 30 minutes and remove the contaminated parts, preferably with gloves. Place them in a sealed plastic bag and take to a local waste disposal facility for recycling. Do not use a vacuum cleaner to remove damaged parts.LENA LIGHTING V-C Sterilon Air Light Z4 -
fig 1LENA LIGHTING V-C Sterilon Air Light Z4 -
fig 2 Use protective gloves when replacing UV-C tubesLENA LIGHTING V-C Sterilon Air Light Z4 - fig 3 4C CHANGING UV-C TUBES 4D CHANGING UV-C TUBES / OPTION: RESET TIME COUNTER To reset the time counter, shorten the PE cable and screw for at least 2 seconds as it shows at the picture. You need to use some of your spare cable to make this connection.LENA LIGHTING V-C Sterilon Air Light Z4 - fig
6 Technical Data:
8x PL-L 36W, 220-240V, 50-60Hz
16x PL-L 36W, 220-240V, 50-60Hz
Cable 3m, 3×0,75mm
Protection class I
With UNI-SCHUCKO / UK plug
No protection against explosion.
The light source used in this luminaire should only be replaced by the manufacturer or his maintenance representative, or a similarly qualified person.
If the external flexible cable is damaged it should be replaced with a special cable available at the manufacturer or its after-sales service.
We would like to inform you that our product’s are marked in accordance with the European Directive 2002/96/CE and Polish Act o n used electric and electronic equipment with a sign of a crossed-out waste container. This mark informs abort the fact that the device, after its application use, cannot be placed together with other types of household waste. The user is obliged to return it to the entities conducting a collection of used electric and electronic equipment. The collection points, including local collection points, shops and municipal entities create a proper system making it possible for the return of the equipment. Proper proceeding with used electric and electronic equipment contributes to the avoidance of damaging consequences for the health of the inhabitants and natural environment chick result form the presence of dangerous substances and improper storage and processing of such devices and equipment.

LENA LIGHTING logo Date of update: 25.07.2022
LENA LIGHTING S.A.
ul.Kornicka 52, 63-000 Sroda Wlkp.
POLAND
tel. +48 61 28 60 300
e-mail: office@lenalighting.pl
www.lenalighting.pl
UV-C STERILON AIR LIGHT Z4 – INSTALLATION INSTRUCTIONLENA LIGHTING V-C
Sterilon Air Light Z4 - icon 2

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals