BLUE SEA SYSTEMS E-Series 5511E Dual Circuit Plus Battery Switch Instruction Manual
- June 6, 2024
- BLUE SEA SYSTEMS
Table of Contents
BLUE SEA SYSTEMS E-Series 5511E Dual Circuit Plus Battery Switch
Features
- Isolates Start and House circuits, and combines both battery banks for emergency starting
- For switching battery banks in applications requiring high power output, reliability, and low heat generation
Tin-plated copper studs
- 3/8″-16 (M10) provide maximum conductivity and corrosion resistance
- One-piece to reduce risk of overheating
- 7/8″ (22.22mm) length to accept multiple cable terminals
Case design
- Allows surface mounting or rear panel mounting
- Accepts up to 4/0 AWG (95mm²) battery cables
Specifications
Cranking Rating: 30 sec. 700A per circuit
Intermittent Rating: 5 min. (UL 1107) 525A per circuit
Continuous Rating 350A per circuit
Voltage Max. Operating 32V DC
Terminal Stud, Tin-Plated Copper 3/8″-16 (M10)
Torque 140 in-lb (15.82 N·m)
Cable Size to Meet Ratings 4/0 AWG (120 mm²)
Ignition Protected
marked
Agency Specifications
- Meets all American Boat and Yacht Council (ABYC) requirements for , battery switches
- UL Listed – UL 1107 for electric power switches
- Meets UL 1500 and SAE J1171 external ignition protection requirements
Guarantee
Any Blue Sea Systems product with which a customer is not satisfied may be
returned for a refund or replacement at any time.
For information about Blue Sea Systems Engine Starting Standard, go to
www.bluesea.com.
Reducing cable sizes will reduce current ratings
Blue Sea Systems, Inc.
4600 Ryzex Way
Bellingham, WA 98226 USA
p 360.738.8230
bluesea.com
Caution
- Disconnect positive battery terminal before installing.
- Consult a marine electrical professional for proper wiring application.
Installation
- Mount in an easily accessible location close to the batteries.
- Attach one 4/0 AWG cable per terminal to meet ratings.
- Refer to the latest edition of NFPA 302 and/or ABYC E11 Standard for installation information.
- Battery cable terminals must be attached under nut. Torque 140 in-lb (15.82 N·m).
Operation
- Turn all appliances off before turning the battery switch to OFF.
- Do not switch to OFF while the engine is running.