BLUE SEA SYSTEMS 980020450 M2 OLED Digital Monitor Installation Guide

June 9, 2024
BLUE SEA SYSTEMS

BLUE SEA SYSTEMS 980020450 M2 OLED Digital Monitor Installation Guide
BLUE SEA SYSTEMS 980020450 M2 OLED Digital Monitor

Components Included

  • M2 Head Unit

  • Surface Mount Bezel and Seal

  • Surface Mount Gasket

  • Surface Mount Cover

  • Flat Mount Bezel

  • Flat Mount Clamp

  • Mounting Ring

  • Mounting Nut

  • Connectors

  • Screwdriver (retail package only)

360 Panel Mounting Kit

PN 1525 sold separately
Panel Mounting

  • 6-32 x 1/4″ Flat Head Machine Screws (4X)

  • 6-32 x 3/8″ Flat Head Machine Screws (4X)

Connector Pin Assignment

Connector Pin Assignment Table

USB Micro USB Port
**4 Pin Connector*** Function
1 AC Voltage 1 – HOT
2 AC Voltage 1 – NEUTRAL
3 AC Voltage 2 – NEUTRAL
4 AC Voltage 2 – HOT
8 Pin Connector** Function
1 Required Connection DC Negative
2 Required Connection DC Positive
3 Relay DC Output
4 Relay DC Supply
5 No Connection
6 No Connection
7 No Connection
8 No Connection

*The 4 pin high voltage connector supports wire sizes from 12-24 AWG
**The 8 pin low voltage connector supports wire sizes from 16-26 AWG.

M2 Meter Navigation

Screen Menu Functions
Press any button to bring up the menu.

  1. After start-up, press any button to access the menu.
  2. Press the UP or DOWN arrow buttons to scroll through menu windows.
  3. To set alarms and for more detailed information, see the online manual at bluesea.com/products/1837
    Meter Navigation

NOTE: The 1837 comes with the 120/240 AC screen disabled. This display can be enabled by pressing: Menu –> Setup –> 120/240 Setup –> Enable

System Overview

Product Overview

Installation Steps

  1. Choose meter mounting style and location
  2. Turn of AC Power
  3. Prepare mounting hole using cutout templates
  4. Using wiring diagram, make all connections to the meter’s connector. Do not put fuses into fuse holders at this time.
  5. Plug wired terminal block into the meter
  6. Insert fuses into fuse holders, making the fuse to Pin 2 (DC Supply) Last.
  7. Turn on AC Power.

Basic Meter Setup

  1. No setup is required.
  2. If you are only monitoring one AC Line, you may want to turn off the unused inputs to prevent them from being displayed.
  3. For information regarding advanced setup options, see the full instructions on our website.

Mounting Options

Flat Mount
Mounting Instructions

Surface Mount
Mounting Instructions
NOTE:
During installation use cover to align the bezel and gasket.

Mounting Templates

Product Dimensions
Product Dimensions

WARNING:
The WARNING symbol refers to possible injury to the user or significant damage to the monitor if the user does not follow the procedures.

CAUTION:
The CAUTION symbol refers to restrictions and rules with regard to preventing damage.

WARNING:
If you are not knowledgeable about electrical systems, have an electrical professional install this unit. The diagrams in these instructions pertain to the installation of the unit and not to the overall wiring of the vessel.
Verify that no other DC or AC sources are connected to the vessel’s wiring before installing the unit.

CAUTION:
The back of the unit is not waterproof. Do not install where the back of the monitor is exposed to water.

Warranty

The M2 OLED Digital Meters come with a 5 year manufacturer’s warranty. This means the meter is warranted to be free from defects in materials or workmanship for 5 years from the date of first purchase. The warranty is limited solely to the cost of repair or replacement of the M2 Meter product. Costs associated with labor or shipping of the defective parts are not covered.
Blue Sea Systems cannot accept liability for damage due to the misuse of the M2 Meter.

Click here for more information at:bluesea.com/products/1837
QR Code

Logo
bluesea.com

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

BLUE SEA SYSTEMS User Manuals

Related Manuals