Components Included
-
M2 Head Unit
-
Surface Mount Bezel and Seal
-
Surface Mount Gasket
-
Surface Mount Cover
-
Flat Mount Bezel
-
Flat Mount Clamp
-
Mounting Ring
-
Mounting Nut
-
Connectors
-
Screwdriver (retail package only)
360 Panel Mounting Kit
PN 1525 sold separately
-
6-32 x 1/4″ Flat Head Machine Screws (4X)
-
6-32 x 3/8″ Flat Head Machine Screws (4X)
Connector Pin Assignment
Connector Pin Assignment Table
USB | Micro USB Port |
---|---|
**4 Pin Connector*** | Function |
1 | AC Voltage 1 – HOT |
2 | AC Voltage 1 – NEUTRAL |
3 | AC Voltage 2 – NEUTRAL |
4 | AC Voltage 2 – HOT |
8 Pin Connector** | Function |
1 Required Connection | DC Negative |
2 Required Connection | DC Positive |
3 | Relay DC Output |
4 | Relay DC Supply |
5 | No Connection |
6 | No Connection |
7 | No Connection |
8 | No Connection |
*The 4 pin high voltage connector supports wire sizes from 12-24 AWG
**The 8 pin low voltage connector supports wire sizes from 16-26 AWG.
M2 Meter Navigation
Screen Menu Functions
Press any button to bring up the menu.
- After start-up, press any button to access the menu.
- Press the UP or DOWN arrow buttons to scroll through menu windows.
- To set alarms and for more detailed information, see the online manual at bluesea.com/products/1837
NOTE: The 1837 comes with the 120/240 AC screen disabled. This display can be enabled by pressing: Menu –> Setup –> 120/240 Setup –> Enable
System Overview
Installation Steps
- Choose meter mounting style and location
- Turn of AC Power
- Prepare mounting hole using cutout templates
- Using wiring diagram, make all connections to the meter’s connector. Do not put fuses into fuse holders at this time.
- Plug wired terminal block into the meter
- Insert fuses into fuse holders, making the fuse to Pin 2 (DC Supply) Last.
- Turn on AC Power.
Basic Meter Setup
- No setup is required.
- If you are only monitoring one AC Line, you may want to turn off the unused inputs to prevent them from being displayed.
- For information regarding advanced setup options, see the full instructions on our website.
Mounting Options
Flat Mount
Surface Mount
NOTE: During installation use cover to align the bezel and gasket.
Mounting Templates
WARNING:
The WARNING symbol refers to possible injury to the user or significant damage
to the monitor if the user does not follow the procedures.
CAUTION:
The CAUTION symbol refers to restrictions and rules with regard to preventing
damage.
WARNING:
If you are not knowledgeable about electrical systems, have an electrical
professional install this unit. The diagrams in these instructions pertain to
the installation of the unit and not to the overall wiring of the vessel.
Verify that no other DC or AC sources are connected to the vessel’s wiring
before installing the unit.
CAUTION:
The back of the unit is not waterproof. Do not install where the back of
the monitor is exposed to water.
Warranty
The M2 OLED Digital Meters come with a 5 year manufacturer’s warranty. This
means the meter is warranted to be free from defects in materials or
workmanship for 5 years from the date of first purchase. The warranty is
limited solely to the cost of repair or replacement of the M2 Meter product.
Costs associated with labor or shipping of the defective parts are not
covered.
Blue Sea Systems cannot accept liability for damage due to the misuse of the
M2 Meter.