EPEVER LS1024EPD Solar Charge Controller User Manual
- June 9, 2024
- EPEVER
Table of Contents
EPEVER LS1024EPD Solar Charge Controller
General Information
LS EPD series solar charge controller adopts the most advanced digital technique and operates fully automatically. It is ideal for extreme environments with corrosion, dust, water, etc., and has various unique functions:
- Electronic protection: Over charging, over-discharging, overload, short circuit, and reverse protection of solar module
- High efficient Series PWM charging increases the battery lifetime and improves the solar system performance
- Widely used, automatically recognizes day/night
- Battery LED to indicate battery status
- Industrial design, the wide application range
- Digital tube menu, only one key solve all setting simply
- Intelligent timer function with 1~13 hours option
- IP67 protection
Features and Mounting
Do not install this product in humid, salt spray, corrosion, greasy, flammable, explosive, dust accumulative, or other severe environments.
① | Charging Status LED indicator | ⑥ | Load Terminals |
---|---|---|---|
② | Battery Status LED indicator | ⑦ | Digital tube |
③ | Temperature Sensor | ⑧ | Key |
④ | Solar Module Terminals | ⑨ | Aluminum housing |
⑤ | Battery Terminals | ⑩ | Mounting hole Φ5 |
--- | --- | --- | --- |
Mounting
- Connect components to the charge controller in the sequence “①Battery > ②Load > ③ PV” and pay much attention to the “+” and “-.” Always power the battery first.
- Check whether the battery indicator is green after powering the battery. If it’s not green, please refer to chapter 4.
- The fast-acting fuse should be installed as close to the battery. The suggested distance is within 150mm.
Indicators Description and Operation
Indicator Status Description
Charging Status LED indicator | Green | On Solid | Normal |
---|---|---|---|
Green | Fast Flashing | Overvoltage |
Battery Status LED indicator
| Green| On Solid| Normal
Green| Slowly Flashing| Full
Orange| On Solid| Under voltage
Red| On Solid| Over discharged
Radix Point of Digital tube
(Load indicator)
| Red| On Solid| Load ON
Red| Slowly Flashing| Over Load
Red| Fast Flashing| Short Circuit
Operation
- After Powering on, disconnect the PV or connect the PV (Voltage <5V), and the light of the digital tube point goes on; Connect the PV (Voltage>6V), and the light of the digital tube point goes off.
- The key can be used to operate switching on/off the load (Manual control) or clearing the faults
- Press the button over 5S to light the digital tube and enter the parameter browsing mode. End-users can cycle browse the parameter by clicking the button.
- After the digital tube displays the value to be configured, release the key and wait for 15S. The Digital Tube stops flashing; the configuration is successful.
Load mode
- Manual Control: Control the load via the button.
- Light ON/OFF Light ON + Timer
Note: In the mode of Light ON/OFF and Light ON/Timer, the Load is turned on after 10Min. Delay.
- Test Mode (Default): Test Mode is the same as Light Control Mode without delay.
The correspondence table of Load Work Mode & LED digital tube value
Value | Working mode | Value | Working mode |
---|---|---|---|
0 | Light ON / OFF | 0. | Light ON + 8 hours |
1 | Light ON + 1 hours | 1. | Light ON + 9 hours |
2 | Light ON + 2hours | 2. | Light ON + 10 hours |
3 | Light ON + 3hours | 3. | Light ON + 11 hours |
4 | Light ON + 4 hours | 4. | Light ON + 12 hours |
5 | Light ON + 5 hours | 5. | Light ON + 13 hours |
6 | Light ON + 6 hours | 6. | Manual Control |
7 | Light ON + 7 hours | 7. | Test Mode |
Troubleshooting
Faults | Possible reasons | Troubleshooting |
---|
Charging LED is off during daytime when sunshine falls on PV
modules properly
| ****
PV array disconnection
| ****
Check that PV and battery wire connections are correct and tight
Battery indicator green fast flashing
| Battery voltage higher than over voltage disconnect
voltage
| 1. Disconnect the solar array and measure whether the battery voltage is
too high; 2. Change the controller; 3. Change the battery
The battery indicator flashes red and loads not working| ****
Battery
over-discharged
| The controller cut off the output automatically. The indicator will return
to green automatically when fully
The radix point of digital tube fast flashing and load not working|
Short circuit
| Clear short circuit. It is reactivated after being delayed 10 seconds for the first time. If over one time, press the key to clear the error, and the controller will resume after
3s or restart the controller
---|---|---
| | Please reduce the number of electric
| | equipment.
The radix point of the digital tube is slowly flashing, and loads are not
working|
Overload
| When load power reaches 1.25-1.5 times, 1.5-2 times, and 2 times more than the nominal value, the controller will turn off loads in 60 seconds, 5 seconds, and 1
second. Press the key to clear the error,
| | and the controller will resume after 3s or
| | restart the controller
Technical Specifications
Item | LS1024EPD | LS2024EPD |
---|---|---|
Nominal system voltage | 12/24VDC Auto | 12/24VDC Auto |
Max. PV input voltage | 50V | 50V |
Rated current | 10A | 20A |
Equalize Voltage | 14.8V(12V); 29.6V(24V) | |
Boost Voltage | 14.4V(12V); 28.8V(24V) | |
Float Voltage | 13.7V(12V); 27.4V(24V) | |
Low Voltage Reconnect Voltage | **** |
12.6V(12V); 25.2V(24V)
Low Voltage Disconnect
Voltage
| ****
11.2V(12V); 22.4V(24V)
Self-consumption| ≤4.58mA(12V); ≤6.01mA(24V)
Temperature compensation coefficient| -5mV/℃/2V(25℃)
Environment temperature| -35℃ ~ +50℃
Enclosure| IP67
Dimension (L x W x H)| 108.5mm × 75mm × 25.6mm
Mounting size| 100.5mm
Mounting hole size| Φ5
Power cable| PV/BAT/LOAD: 4.0mm2| PV/BAT/LOAD: 6.0mm2
Net weight| 410g| 435g
Any changes without prior notice! Version number: V2.2
- Website: www.epever.com
- Tel: +86-752-3889706